APPROVED, Rhino FL15216_R8_II_2020_12_15_FINAL_ER_OWENS CORNING_RHINOROOF_FL15216-R8
NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 Evaluation Report I40510.02.12-R9 FL15216-R8 Date of Issuance: 02/17/2012 Revision 9: 12/15/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/15/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report I40510.02.12-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R8 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 2 of 4 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tear strength ASTM D4533 2015 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1518.4, RAS 115 Unrolling, Breaking Strength, Pliability ASTM D226 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ITS (TST1509) ASTM D226 100539395COQ-006 10/26/2011 ITS (TST1509) ASTM D4869 100539395COQ-002 10/26/2011 PRI (TST5878) ASTM D226 / D4798 / D4869 OCF-394-02-07.4 01/06/2020 PRI (TST5878) ASTM D226 / D4798 OCF-464-02-02.2 01/06/2020 PRI (TST5878) ASTM D4533 / D5035 / D4798 1378T0109 10/15/2020 PRI (TST5878) ASTM D4533 / D5035 1378T0127 10/15/2020 ITS (QUA1673) Quality Control Service Confirmation 12/09/2020 ITS (QUA1673) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.1 RhinoRoof U20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Qingdao, China Multilayered polymer woven coated synthetic roof underlayment 4.2 ABC Pro Guard 20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Silvassa, India Multilayered polymer woven coated synthetic roof underlayment 43 SRS TopShield TS20 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Silvassa, India Multilayered polymer woven coated synthetic roof underlayment NEMO|etc. NEMO ETC, LLC Evaluation Report I40510.02.12-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R8 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 3 of 4 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers: TABLE 1: ROOF COVER OPTIONS FBC NON-HVHZ: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 FBC HVHZ: TAS 110(S10), RAS 115 TAS 110(S11), RAS 118, 119 & 120 RAS 133 TAS 110(S11) RAS 130 Underlayment Asphalt Shingles Clay and Concrete Tile Metal Slate or Slate-Type Shingles Wood RhinoRoof U20 Yes No Yes No NON-HVHZ: No HVHZ: Yes ABC Pro Guard 20 Yes No Yes No NON-HVHZ: No HVHZ: Yes SRS TopShield TS20 Yes No Yes No NON-HVHZ: No HVHZ: Yes 5.6 Exposure Limitations: TABLE 2: EXPOSURE LIMITATIONS Underlayment Maximum Exposure (days) RhinoRoof U20 60 ABC Pro Guard 20 30 SRS TopShield TS20 30 NEMO|etc. NEMO ETC, LLC Evaluation Report I40510.02.12-R9 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R8 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 9: 12/15/2020 Page 4 of 4 6. INSTALLATION: 6.1 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance with the manufacturer’s published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments: 6.3.1 NON-HVHZ Jurisdictions: 6.3.1.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer’s installation instructions. FBC requirements take precedence over the manufacturer’s installation instructions. 6.3.1.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.3.2 HVHZ Jurisdictions: 6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side (horizontal) laps and minimum 6-inch wide end laps, and fastened in accordance with FBC HVHZ 1518.2. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc. – QUA1673; (312) 906-7779; maura.norlander@intertek.com - END OF EVALUATION REPORT -