HomeMy WebLinkAboutCompaction TestArdaman in -Place Density Report
& Associates, Inc. Permit # 2011-0280
Report Date: 1/25/2021
Port St. Lucie Branch Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Phone:772-878-0072
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Jan 25, 2021 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
mw'uArdamanln-Place
Density Report Client:
& Associates, Inc.
Permit # 2011-0280
Report Date: 1/25/2021
Port St. Lucie Branch
Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Ar
Phone:772-878-0072
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
Test Results
Test #
Retest
Of
Test Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry
Density (pcf)
In Place
Moisture
%
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
%)
Remark
406
1115/21
21-018
Modified)
A
--
11.0
109.5
7.1
108.4
116.1
12
99
95
Pass
407
1/15/21
21-018
(Modified)
A
11.0
109.5
5.0
108.9
114.3
12
99
95
Pass
408
1/15/21
21-018
(Modified)
A
11.0
109.5
6.9
107.0
114.4
12
98
95
Pass
409
1/15/21
21-018
(Modified)
A
11.0
109.5
7.6
106.9
115.0
12
98
95
Pass
410
1/15/21
21-018
(Modified)
A
11.0
109.5
9.0
108.3
118.0
12
99
95
Pass
411
1/15/21
21-018
(Modified)
A
-
11.0
109.5
6.4
107.3
114.2
12
98
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
406
Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. NW End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
407
Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. NE End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
408
Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. SE End of Pad
-1.0
Top of pad
CPN / MC-3l M340507395 /
Tech, Port St. Lucie
409
1 Footings: Lot 94, 9795 Palm Breezes Drive. SE End of Footings
-2.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
410
Footings: Lot 94, 9795 Palm Breezes Drive. SW End of Footings
-2.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
411
Footings: Lot 94, 9795 Palm Breezes Drive. NW End of Footings
-2.0 ITop
of pad
I CPN / MC-3l M340507395 /
Tech, Port St. Lucie
Remarks
I
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.