Loading...
HomeMy WebLinkAboutEnergy CodeRECEIVED FORM R405-2017 OCT ..t 2 2019 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDINGtQQN§TRUCTION At s 'Pe ucl eo Florida Department of Business and Professional Regulation - Residential fie cr0rice Method Project Name: 2959 Yates Rd Builder Name: Street: 2959 Yates Rd Permit Office: ST LUCIE COUNTY *City, State, Zip: FORT PIERCE, FL , 34981 Permit Number: 1712-0310 Owner: O'Brian Jurisdiction: 611000 Design Location: FL, ST_LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1320.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insut, Exterior R=4.2 i320.30 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1406.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1406.00 ft2 6. Conditioned floor area above grade (ft2) 1406 b. N/A R= ft2 c. NIA R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(148.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 281.2 a. U-Factor: Dbl, U=0.29 73.49 ft2 SHGC: SHGC=0.19 b. U-Factor: Dbl, U=0.34 35.56 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a. Central Unit 28.0 SEER:16.00 c. U-Factor: Dbl, U=0.24 28.67 ft2 SHGC: SHGC=0.23 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 10.67 ft2 a. Electric Strip Heat 26.0 COP:1.00 SHGC: other (see details) ` Area Weighted Average Overhang Depth: 6.996 ft. Area Weighted Average SHGC: 0.199 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1406.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1406.00 ft2 b. Conservation features b. WA R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.106 Total Proposed Modified Loads: 46.15 PASS Total Baseline Loads: 48.21 I hereby certify that the plans and specifications covered by Review of the plans and 0�.1015 Sr this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ,.., PREPARED BY: Before construction is completed DATE: 6 this building will be inspected for compliance with Section 553.908 FN # ° I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as ,certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). File COPY 10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 Fn12M Rd(1',_7nl7 PROJECT Title: Building Type: ' Owner Name: I of Units: Builder Name: Permit Office: "Jurisdiction: Family Type: New/Existing: Comment: 2959 Yates Rd User O'Brian 1 ST LUCIE COUNTY 611000 Single-family New (From Plans) Revised window values Bedrooms: 2 Conditioned Area: 1406 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # 5 Block/Subdivision: PlatBook: Street: 2959 Yates Rd County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34981 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1406 12091.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1406 12091.6 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 162 ft 0 1406 ftz ---- 0 0 1 ROOF / V # Roof Gable Roof Type Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 1482 ftz 0 ftz Medium 0.85 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1406 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1406 ftz 0.11 Wood 10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 PnRM R4h.S-9017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block - Int Insul Main 4.19999 49 8 6 416.5 ft2 0 0.75 0 Ap 2 E Exterior Concrete Block - Int Insul Main 4.19999 12 4 8 6 104.8 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 4.19999 19 8 8 6 167.2 ft2 0 0.75 0 w 4 S Exterior Concrete Block - Int Insul Main 4.19999 24 8 8 6 209.7 ft2 0 0.75 0 5 S Exterior Concrete Block - Int Insul Main 4.19999 17 8 6 144.5 ft2 0 0.75 0 6 W Exterior Concrete Block - Int Insul Main 4.19999 32 8 8 6 277.7 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .4 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.24 0.23 N 12.7 ft2 2 ft 0 in 1 ft0 in None None 2 N 1 Vinyl Low-E Double Yes 0.24 0.23 N 3.3 ft2 2 ft 0 in 1 ft 0 in None None 3 N 1 Vinyl Low-E Double Yes 0.29 0.19 N 4.2 ft2 2 ft 0 in 1 ft 0 in None None 4 E 2 Vinyl Low-E Double Yes 0.29 0.19 N 16.6 ft2 2 ft 0 in 1 ft 0 in None None 5 E 3 Vinyl Low-E Double Yes 0.29 0.19 N 33.3 ft2 7 it 0 in 1 ft 0 in None None 6 S 4 Vinyl Low-E Double Yes 0.24 0.21 N 10.7 ft2 2 ft 0 in 1 ft 0 in None None 7 S 4 Vinyl Low-E Double Yes 0.29 0.19 N 19.4 ft2 2 it 0 in 1 ft 0 in None None 8 S 5 Vinyl Low-E Double Yes 0.34 0.19 N 35.6 ft2 14 ft 0 in 1 ft 0 in None None 9 W 6 Vinyl Low-E Double Yes 0.24 0.23 N 12.7 ft2 2 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000273 1007.6 55.32 104.03 .2049 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 26 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 28 kBtu/hr 840 cfm 0.75 1 sys#1 10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 PrNP11A RdC1-,,_7nl7 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.98 40 gal 50 gal 120 deg None r SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 281.2 ft Attic 70.3 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan Heatin[X] Jan [[ ]] Feb [Xj Feb Mar Mar WPr r [[ jj Ma [X]] Jun Jul [ j May i j Jun JXJJul Au �XjAuSep rl Se Oct WOct Nov Nov HX Dec Dec H Ventin [[ ]] Jan [[ ]j Feb X Mar A r [[ jj Ma [ ]] Jun Jul Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1019/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 2959 Yates Rd, FORT PIERCE, FL, 34981 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.2 1320.30 ft2 b. NIA R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1406.00 ft2 6. Conditioned floor area (ft2) 1406 b. N/A R= ft2 c. NIA R= ft2 7. Windows" Description Area 11. Ducts R ft2 a. U-Factor: Dbl, U=0.29 73.49 ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 281.2 SHGC: SHGC=0.19 b. U-Factor: Dbl, U=0.34 35.56 ft2 SHGC: SHGC=0.19 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.24 28.67 ft2 a. Central Unit 28.0 SEER:16.00 SHGC: SHGC=0.23 ' d. U-Factor: other (see details) 10.67 ft2 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 26.0 COP:1.00 Area Weighted Average Overhang Depth: 5.996 ft. - Area Weighted Average SHGC: 0.199 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1406.00 ft2 a. Electric EF: 0.98 b. N/A R= ft2 b. Conservation features c. N/A R= fJ2 None 15. Credits Pstat 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: , THE S74? ��+ CWE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R`405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method ,.Project Name: 2959 Yates Rd Builder Name: Street: 2959 Yates Rd Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34981 Permit Number: 1712-0310 Design Location: FL, ST_LUCIE_CO_INTL Jurisdiction: 611000 Cond. Floor Area:: 1406 sq.ft. Cond. Volume: 12092 cu ft. Envelope Leakage Test Results Regression Data: C: n: Single or Multi Point Test Data R: HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa cfm 4 Pa cfm 5 Pa cfm 6 Pa I cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 : Tested ACH(50) * : *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE: Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0(g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: yCeTTIE ST.gpot 10/9/2018 8:58 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1