HomeMy WebLinkAboutEnergy CodeRECEIVED
FORM R405-2017 OCT ..t 2 2019
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDINGtQQN§TRUCTION
At
s 'Pe
ucl eo
Florida Department of Business and Professional Regulation - Residential fie cr0rice Method
Project Name: 2959 Yates Rd
Builder Name:
Street: 2959 Yates Rd
Permit Office: ST LUCIE COUNTY
*City, State, Zip: FORT PIERCE, FL , 34981
Permit Number: 1712-0310
Owner: O'Brian
Jurisdiction: 611000
Design Location: FL, ST_LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1320.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insut, Exterior
R=4.2 i320.30 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1406.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1406.00 ft2
6. Conditioned floor area above grade (ft2) 1406
b. N/A
R= ft2
c. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(148.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 281.2
a. U-Factor: Dbl, U=0.29 73.49 ft2
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.34 35.56 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.19
a. Central Unit
28.0 SEER:16.00
c. U-Factor: Dbl, U=0.24 28.67 ft2
SHGC: SHGC=0.23
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 10.67 ft2
a. Electric Strip Heat
26.0 COP:1.00
SHGC: other (see details)
` Area Weighted Average Overhang Depth: 6.996 ft.
Area Weighted Average SHGC: 0.199
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1406.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 1406.00 ft2
b. Conservation features
b. WA R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.106 Total Proposed Modified Loads: 46.15
PASS
Total Baseline Loads: 48.21
I hereby certify that the plans and specifications covered by
Review of the plans and
0�.1015 Sr
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
,..,
PREPARED BY:
Before construction is completed
DATE: 6
this building will be inspected for
compliance with Section 553.908
FN
# °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
,certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
File COPY
10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
Fn12M Rd(1',_7nl7
PROJECT
Title:
Building Type:
' Owner Name:
I of Units:
Builder Name:
Permit Office:
"Jurisdiction:
Family Type:
New/Existing:
Comment:
2959 Yates Rd
User
O'Brian
1
ST LUCIE COUNTY
611000
Single-family
New (From Plans)
Revised window values
Bedrooms: 2
Conditioned Area: 1406
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot # 5
Block/Subdivision:
PlatBook:
Street: 2959 Yates Rd
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34981
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1406 12091.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfiIID Finished Cooled Heated
1
Main
1406 12091.6 Yes 3
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 162 ft 0
1406 ftz
---- 0 0 1
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip Composition shingles 1482 ftz 0 ftz Medium
0.85
No 0.9 No 0 18.4
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1406 ftz
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1406 ftz 0.11 Wood
10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
PnRM R4h.S-9017
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Space
_ 1
N
Exterior Concrete Block - Int Insul
Main
4.19999 49 8
6
416.5 ft2
0 0.75
0
Ap 2
E
Exterior Concrete Block - Int Insul
Main
4.19999 12 4 8
6
104.8 ft2
0 0.75
0
3
E
Exterior Concrete Block - Int Insul
Main
4.19999 19 8 8
6
167.2 ft2
0 0.75
0
w 4
S
Exterior Concrete Block - Int Insul
Main
4.19999 24 8 8
6
209.7 ft2
0 0.75
0
5
S
Exterior Concrete Block - Int Insul
Main
4.19999 17 8
6
144.5 ft2
0 0.75
0
6
W
Exterior Concrete Block - Int Insul
Main
4.19999 32 8 8
6
277.7 ft2
0 0.75
0
DOORS
#
Omt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E Insulated
Main
None
.4
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID Frame Panes
NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Low-E Double
Yes
0.24 0.23 N
12.7 ft2
2 ft 0 in
1 ft0 in
None
None
2
N 1 Vinyl Low-E Double
Yes
0.24 0.23 N
3.3 ft2
2 ft 0 in
1 ft 0 in
None
None
3
N 1 Vinyl Low-E Double
Yes
0.29 0.19 N
4.2 ft2
2 ft 0 in
1 ft 0 in
None
None
4
E 2 Vinyl Low-E Double
Yes
0.29 0.19 N
16.6 ft2
2 ft 0 in
1 ft 0 in
None
None
5
E 3 Vinyl Low-E Double
Yes
0.29 0.19 N
33.3 ft2
7 it 0 in
1 ft 0 in
None
None
6
S 4 Vinyl Low-E Double
Yes
0.24 0.21 N
10.7 ft2
2 ft 0 in
1 ft 0 in
None
None
7
S 4 Vinyl Low-E Double
Yes
0.29 0.19 N
19.4 ft2
2 it 0 in
1 ft 0 in
None
None
8
S 5 Vinyl Low-E Double
Yes
0.34 0.19 N
35.6 ft2
14 ft 0 in
1 ft 0 in
None
None
9
W 6 Vinyl Low-E Double
Yes
0.24 0.23 N
12.7 ft2
2 ft 0 in
1 ft 0 in
None
None
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000273
1007.6 55.32 104.03
.2049
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA
26 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ None
SEER: 16
28 kBtu/hr 840 cfm
0.75 1
sys#1
10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
PrNP11A RdC1-,,_7nl7
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Main
0.98 40 gal 50 gal
120 deg
None
r
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply —
— Return—
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 281.2 ft
Attic
70.3 ft2 Default Leakage
Main
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[[ ]] Jan
Heatin[X] Jan
[[ ]] Feb
[Xj Feb
Mar
Mar
WPr
r
[[ jj Ma [X]] Jun Jul
[ j May i j Jun JXJJul
Au
�XjAuSep
rl Se
Oct
WOct
Nov
Nov
HX
Dec
Dec
H
Ventin [[ ]] Jan
[[ ]j Feb
X Mar
A r
[[ jj Ma [ ]] Jun Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
PM
80
80
78
78 78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
1019/2018 8:57 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
2959 Yates Rd, FORT PIERCE, FL, 34981
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.2
1320.30 ft2
b. NIA
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
1406.00 ft2
6. Conditioned floor area (ft2)
1406 b. N/A
R=
ft2
c. NIA
R=
ft2
7. Windows" Description
Area
11. Ducts
R ft2
a. U-Factor: Dbl, U=0.29
73.49 ft2 a. Sup: Attic, Ret: Attic, AH: Main
6 281.2
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.34
35.56 ft2
SHGC: SHGC=0.19
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.24
28.67 ft2 a. Central Unit
28.0 SEER:16.00
SHGC: SHGC=0.23
' d. U-Factor: other (see details)
10.67 ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC: other (see details)
a. Electric Strip Heat
26.0
COP:1.00
Area Weighted Average Overhang Depth:
5.996 ft.
- Area Weighted Average SHGC:
0.199
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1406.00 ft2 a. Electric
EF: 0.98
b. N/A R=
ft2
b. Conservation features
c. N/A R=
fJ2
None
15. Credits
Pstat
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
, THE S74? ��+
CWE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/9/2018 8:57 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R`405-2017 Envelope Leakage Test Report Performance
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Performance Method
,.Project Name:
2959 Yates Rd
Builder Name:
Street:
2959 Yates Rd
Permit Office: ST LUCIE COUNTY
City, State, Zip:
FORT PIERCE, FL, 34981
Permit Number: 1712-0310
Design Location:
FL, ST_LUCIE_CO_INTL
Jurisdiction: 611000
Cond. Floor Area::
1406 sq.ft.
Cond. Volume: 12092 cu ft.
Envelope Leakage Test Results
Regression Data:
C: n:
Single or Multi Point Test Data
R:
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
cfm
4
Pa
cfm
5
Pa
cfm
6
Pa
I cfm
Leakage Characteristics
Required ACH(50) from
FORM R405-2017 :
Tested ACH(50) * :
*Tested leakage must be less than or equal to the
required ACH(50) shown on Form R405-2017 for
this building. If the tested ACH(50) is less than 3
the building must have a mechanical ventilation
system.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved
third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
SIGNATURE:
PRINTED NAME:
DATE:
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(0(g), or (i) or an
approved third party. A written report of
the results of the test shall be signed
by the third party conducting the test
and provided to the code official.
BUILDING OFFICIAL:
DATE:
yCeTTIE ST.gpot
10/9/2018 8:58 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1