Loading...
HomeMy WebLinkAboutEvaluation Report; Fiberglass Glazed Door Inswing & Outswing ImpactR W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.Q. Box 230 Valrico, FL 33595 Phone 81.3.659.9197 Florida Board of Professional Engineer; Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation smooth Star, Fiber Classic, Classic Craft & Classic Craft Rustic Exterior Swinging Exterior Door • 118 Industrial Dr. Fiberglass Glazed Door Doors Assemblies Edgerton, OH 43517 Inswing I Outswing Phone 419.298.1740 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 d of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-10975A require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using coastal sill item #31 under active doors meet water infiltration requirements for "HVHZ". S. Inswing configurations and outswing configurations using sill items #18, #14, #15, #16, #34 and item #37 under the door do not meet the water infiltration requirements for the "HVHZ" and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 9. See drawing FL-10975.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01460336 A,B,C ASTM D635-03, ASTM D1929-96, Testing Evaluation Labs Lyndon F. Schmidt, P.E. TEL 01460339 A,B,C TEL 01460030 STT800001 15427-107362 AT[ 67508.01-106-18 ASTM D2843-99 ASTM D635-03, ASTM D1929-96, ASTM D2843-99 TAS 201-94, 202-94 & TAS 203-94 ASTM G26-95 ASTM E84-00a ASTM D1929-96 Testing Evaluation Labs Testing Evaluation Lab., Inc. Sub -Tropical Testing Omega Point Laboratories Architectural Testing, Inc. Lyndon F. Schmidt, P.E. Wendell W. Haney, P.E. Lon Hicks, VP Operations William E. Fitch, P.E. Joseph A. Reed, P.E. 2. Miami -Dade NOA Materials 17-0712.04 Saflex Interlayer (Eastman Chemical Company) 3. Drawing No. Prepared by Signed &Sealed by No. FL-10975.1 RW Building Consultants,'Inc. (CA#9813) Lyndon F. Schmidt, P.E. 4. Calculations Prepared by Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) �8m899prtgdd Lyndon F. Schmidt, P.E. ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. 5. Quality Assurance % -- o00 p y v i�d�l0 E hl `g fi•" o oo�d Certificate of Participation issued b National Accreditation and Management Institute, certifying that Therma Tru Corporation is Z No 43409 manufacturing products within a quality assurance program that complies with ISOBEC 17020 and Guide 53. a J A STATE OF a 1tJLyndon F. Schmidt, P.E. FL PE No. 43409 �{a i10 N ®�► 10/17/2017 Sheet 1 of 1 o®oos, k� �o IHERMAITRU 0 THERMA TPU DOORS 1 1 B INDUSTRIAL DR., EDGERTON, ❑H 4351 7 "SMOOTH STAR', "FIBER CLASSIC'; "CLASSIC CRAFT" & "CLASSIC CRAFT RUSTIC" FIBERGLASS GLAZED DOOR INSWING / OUTSWING ,rimmcr GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ' this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609J.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.122 & R301.2.1.2.1. 5, For 2xstud framing construction, anchoring of these units shall be the same as that shown for 2( buck masonry construction. 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using coastal sill item #31 under active doors meet water infiltration requirements for "HVHZ'. 8. Inswing configurations and outswing configurations using sill items #18, #14, #15, #16, #34 & #37 under the door do not meet the water infiltration requirements for the "HVHZ' and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill Is less than 45 degrees. TABLE OF CONTENTS SHEET# DESCRIPTION SHEET It DESCRIPTION 1 Typical elevations, design pressures & general notes 7 Vertical cross sections 2 Door panel details & glazing details (Smooth Star) 8 Buck and frame anchoring 2X buck masonry construction 3 Door panel details (Fiber Classic) 9 Frame anchoring iXbuck masonry construction 4 Door panel details (Classic Craft) 10 Components 5 Door panel details (Classic Craft Rustic) 11 Bill of materials 6 Horizontal cross sections A �, o z 37.75' MAX, ice"• FRAME WIDTH ��i� y '••....• 36.00" MAX. PANEL WIDTH / C9 _ S � W = w Y Z /\ m ` OVERALL DESIGN PRESSURE (PSFJ„ SWING FRAly1E OIAAEN510N POSITIVE NEGATIVE: INSWING 37.75' x 82.09' +55.0 -55.0 OUTSWING 37.75'x80.62' +55.0 -55.0 By JK c er LFS WING NO.: FL-10975.1 Er 1 of 11 R:\ClientsMiTru PERMANEN IA - Florida Prod.d Approvals\FL-10975\C - Dawmgs\FL-10975 (2017ffL-10975.1-3.dw9, 2.1 AW O 51 0m —Zi m m A v � O M � O N A - a m n G7 �m �— m - O Cw D vO NNv rnm [TZ[n1 m m m p � rn C7 < O m 65.33" MAX. D.L.O. v� QO �~ 0 0 0 v 3ct), 0o A r N N �z D m 1.54" —{ x cq V Llll1 inn —r- m A_ O �;Mu ...... .. ... s F• Wi /i No.43409 I� o o m Z -i x y N 3 vt 2 o 1 NO PRODUCT: THERMA TRU FIBERGLASS GLAZED DOOR Document. Prepared Q �V - �9►1Ea` j Lyndon F. Schmidt //��' ����:•' �� P.E. No. 43409 t,��`� @p/� BUILDING CONSULTANTS. INC. 1/I/P.O. Box 230, Valrico, FL 33595 VY phone No.: 813.659.9197 FBPE CA No. 9813 17 UPDATE TO �IK 10 30 15 UPDATE TO STH ED1 . 2014 FBC 2129112 UPDATE TO 2010 FBC PART OR ASSEMBLY, DOOR PANEL DETAILS S GLAZING DETAILS (SMOOTH STAR 3 9 11 REVISE CLASSIC CRAFT DOOR DATE JIK REVISIONS R:Xalents\Thenna T. PERMANENr\A - Florida Product AppruvalsXFL-10975\C - Drawhgs\FL-10975 (2017)\FL-10975.1-3.dwg, 3.1 (I. 653TMAX. D.L.O. 03 %B3 VO 0 > tT ri 0.911, 0 125 ME77771 1.56" 1 4 10 17 17 UPDATE To 6TH ED. (201 FBC JK .3 5TH ED. (2014) FBC JK rN UPDATE TO 2010 FBC JK 3 9011 REVISE CLASSIC CRAFT 15 0. DATE BY 5 2009 P— 9111L.1 . . . . . . . —.1. — X r. 5< wa III," %%,%%I S C No.. 43409 October 17. 20171, iDUCT- Documents Prepared . ... Lyndon F. Schmidt ij� THERMA—TRU FIBERGLASS GLAZED DOOR ....... P.E. No. 43409 T OR ASSEMBLY: BUILDING CONSULTANTS, INC. RW I R PANEL DETAILS )OFF78ER CLASSIC) P.O. Box 230, Voirico, FL 33595 Ph."e, No.: 813.659.9197 FBPE C.A. No. 9813 R:\Clents\Theana Tro PERMANEMW - Flodda Product Approvals\FL-10975\C- Drawings\FL-10975 (2017)\R.-10975.1-3.dw0, 4.1 o ? 3 rn I;' ! 0o ? (Nil I- ;R s 65.33" MAX. D.LO. 4 0 0 T;0= a A z a r_ n A O N N N n N r---r0.79" z O 4 10 17 17 UPDATE TO 6TH ED. 2017 FBC JK 3 1 30 15 UPDATE TO 5TH ED. 2014 FBC JK 2 2 29 12 UPDATE TO 2010 FBC JK 1 3 9 11 REVISE CLASSIC CRAFT DOOR JK NO DATE 8Y FD 2DO9 R.W. BULDING CCNSIILTANTS INC l G = * 9 yt E1k October 17 2017� PRODUCT: THERMA—TRU FIBERGLASS GLAZED DOOR Document. Prepored By:i,vt Lyndon F. Schmidt . �.. .... P.E. No. 43409 Si$�OIVAIitG;;��� GD BUILDING CONSULTANTS, INC. PART OR ASSEMBLY: DO R PANEL DET ILS CLASSIC DRA T tJ P.O. Box 230, Valrfco, FL 33595 Phone No.: 813.659.9197 FBPE C.A. No. 9813 R:\COents\Thenra Tru PERMANENT\A - Flodda Product Approva1s\FL-10975\C - Drawings\FL-10975 (2017)\FL-10975.1-3.dwg, 5.1 M. o TP zsD 0 X Z IF 7.94' 1.49' �{ V I m 65W MAX• D.L.O. 4 00 N N Ma m a a rc n tyit Z n M m 0 N W � ND. 43409 October 17 2017' $ '�• PRODUCT: Document. Prepored By. .�'• Lyndon F. Schmidt i/�s••.OR1DM,: •� r UPDATE TO 6TN ED. 2017 FBC I JK THERMA—TRU FIBERGLASS GLAZED DOOR ``�� P.E. No. 43409 o Z ro 3 w UPDATE TO 5TH 2014 FBC JK ffilllltll �K PART OR ASSEMBLY: GD BUILDING CONSULTANTS, INC. I" (Vii x 0 1REVISE m CLASSIC CRAFT DOOR DOOR PANEL DETAILS P.O. Box 230, VDIHeo, FL 33595 NO DATE BY (CLASSIC CRAFT RUSTIC) Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 io 2CC9 R_W. (3 NILGING CGN9NLTYNTS INC. R:%Oients\Thenna Tru PERMANE" - Florida Product Approvals\FL-10975\C - Drawings\FL-10975 (2017)\FL-10975,1-3.dwg, 6.1 m r • A �3 . z _ v. v ° o m ,c _ O 20 ' 2.2 A _ 000 T 0. t- } I 'DO Rn-0 V V W V j C-=Q r+1 VA V Al OO O V O O V H r Z m rn Z m aw aN O O � o a W m Z o o M 00 0 iT7 A N r X c � A C O ri1 � O m ° a a M m H a a.a d d O M O A fh O O A p N O O S y03 ?�H N a- 7q OD V 13 n l o A 1_ o a <� O CL �m y n o O Z rn 4 < O e ° 3 �•scHly��•/,� ' ? No. 43409 October 17 2017� • PRODUCT: Document. Pr.p—d eY: • `� ��,�•'•Q�• j z cr THERMA TRU FlBERGLASS GLAZED DOOR Lyndon F. Schmidt �� P.E. No. 43409 //,/��OjA`Cz I� .. L, ,`��� PART OR ASSEMBLY: 0 w w (iD BUILDING CONSULTANTS, INC. I� m HORIZONTAL P.O. Box 230, VDlrieo, FL 33595 CROSS SECTIONS Phona No.: 813.659.9197 'REVISIONS FBPE CA No. 9813 ® 2009 R.W. BUILDING CONSULTANTS INC. .Q Q 4 10 17 17 UPDATE TO 6TH ED. 2017 FBC JK 3 1 30 15 UPDATE 70 57H ED. 2014 FBC JK 2 2 29 12 UPDATE 70 2010 FBC JK 1 3 9 i f REVISE CLASSIC CRAFT DOOR JK NO DATE BY R:\Otente\Thenna Tru PERMANENT\A- Florida Product Approvals\FL-10975\C- Drawings\FL-10975 (2017)\FL-30975.1-3.dwg, 7.1 1-1/4' MIN. EMB. (TYP.) o o M Z A o .c z O O v A 'yOc�C ZT m mymo A ` o^ O 70 I m r0 O 0 CD O G) M N ° •.. -•. a N M 'y' m z ° z C v ° MINK v cp.w (TYP.) C. m EMB. (TYP.) m V A t3omOC to <m �Fag� "moan 2. o� - N N Z O :: pO ° Z7 _- O ZI z v O. fJr A 1-1/4" MIN. EMB. (TYP.) 1-11,V MIN. v EMB. (TYP.) O O M T O O m CD CD° m c $ 22 A VN D moOC ° a �C en gro , mGm� p� N N ro y °' n >' 00� N2o? X� A O O o CA 7'S=N Q nH om�T y >rA a. �— °p m i0 m H zz A z A DD V G ' v n ' MIN. v �.,•% EINIB. (TYP.) EMB. No. 43409 Ocrober 17 2017- i f 75 P g PRODUCT: Documents Prepared By:i� �� o rn 71(�MA TRU FIBERGLASS GLAZED DOOR Lyndon F. Schmidt j�•••••homOr`' (J� P.E. No. 43409 ii7+�O�\\� MA�.1\\\\ 4 10 17 17 UPDATE TO 6TH ED. 2017 FBC JK 3 1 30 15 UPDATE TO 5TH ED. 2014 FBC JK Iv o Z ro I!!!! 2 2 29 12 UPDATE TO 2010 FBC JK PART OR ASSEMBLY: m y to GQ BUILDING CONSULTANTS, INC. i 3 9 11 REVISE CLASSIC CRAFT DOOR JK I' N !A o Da CAL P.O. Box 230, Valrtao, FL 33595 NO DATE CROSSVER71 SECTIONS Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 R:\Cients\Thenna Tm PERMANENT\A - Florida Product Approvals\FL-3097%- Drawings\FL-10975 (2017)\FL-10975.1-3.dwg, 8.1 O2.1 T Aa 18.94" MAX. 4. O.C. (TYP.) a m 29.25" I 10.37'FROM TYP" HINGE -r = TOP OF TO HINGE DOOR PANEL 09 X ZO c Y G n m O o T � A 7f N s3 r X m y R° C 0 0 '2 yv 00 czi a. o� 1O.C. (Tl'P.) b" I® —�i OM 5.5' Imo— OP OF DOOR PANEL c1 n �• o x � a T No. 43408 cc) October 17 2017� i g PRODUCT: Document. Prepared ey:i� ,•� �.•�•'•!20(t1Qw-•O``� THERMA TRU Lyndon F. Schmidt P.E. No. 43409 I0D 4 3 10' 17 17 1 30 15 UPDATE TO 6TH ED. 2017 FBC UPDATE TO 5TH ED. 2014 FBCUPDATE JK FlBERGLASS GLAZED DOOR o Z rya TO 2010 FBC K PART OR ASSEMBLY: WCIAI BUILDING •FL y t7l O i 3 9 11 REVISE CLASSIC CRAFT DOOR BUCK AND FRAME ANCHORING 2X ://��// Box 230, Valriico 33595 Q7 NO DATE BY BUCK MASONRY CONSTRLIC17ON phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 6" to %TYP. HEAD & JAMBS —J MASONRY OPENING FRAME CL I X BUCKI- 0 TY P. SILL HINGE JAMB FRAME ANCHORING Masonry I X buck construction CONCRETE ANCHOR NOTES: I. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as "MAX ON CENTER" must be adjusted to maintain the min. edge distance to mortarloints, additional concrete anchors maybe required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: gNCHOR .......... ANCHOR Mly MIN CLEARANCE MIN CLEARANCE :J0 MASONRY .... . . .. ....... ..... ..... .... ...... ... ................ . . ... ........... EDGE ANCHOR ITW 114" 1.1/1C -2' 4" TAPCONO ELCO, 114- 1-114- 1. 47 ULTRACONG WOOL) SCREW INWALLATUN NUH:X I. Maintain a minimum5fir edge distance, I" end distance,& I-o.c. spacing of I wood screws to prevent the splitting of wood. I STRIKE JAMB HINGE DETAIL OutsyAng LATCH & DEADBOLT DETAIL HINGE DETAIL Inswing A 5-4 z - N.T.S. sy.. JK Ery.. LFS WING NO-' FL-10975.1 Er 9 OF 11 R:\Qients\Thenna Tru PERMANENT)A- Florlda Product Appmvals\FL-10975\C-Dmv4ngs\FL-10975 (2017)\FL-10975.1-3.dwg, 10.1 1.01, CIN o� 0 go 'o 00 c� 05 5 R M 0 n6 -rlo E2=0 0 Ham Z to no �2 CL c� (D -M 0 09 6�1 > asp CL UO au Cn 0.906, Cl sq. 0.434 9 October 17, 2017al PRODUCT- Do-menta PMpdmd By.-i,VE THERMA TRU Lyndon F. Sch-ldt ....Ftor.... • P.E. No. 43409 ]N��7 UPDATE TO 6TH ED. (2017) FEIC JK FIBERGLASS GLAZED DOOR UPDATE TO 5TH ED. (2014) FBC JK 11,1111111100 C, 0 JK PART OR ASSEMBLY. BUILDING CONSULTANTS. INC. 2 29 12 UPDATE TO 2010 FEC 1 3 9 11 REVISE CLASSIC CRAFT DOOR JK X, PO. Box 230. Valrico, FL 33595 NO. DATE BY COMPONENTS IU(P'h.n. No.: 813.659.9197 REVISIONS I FBPE C.A. No. 9813 •% 4 N %N z ri fpo�� UN•• NQ� Z%ZU Em°.2a �Kgj Ng9rm v maaU. LL d OE vZ ^K, w v, 0 Q J �W Q CD �y CD at c~i w o a K J m O N J_ m 0 a >?»m O >N W i m w = m Z 0 U U m� 00 N N W WTi� No O O 000v' > > 0 0 U t N U O U > � N ^ O' N N NMIO .0 MIN-o DAM 6125108 z SCAM N.T.S. 3 DWG, BY. JK m UK BY: LFS ? DRAWN NO.: C m FL-10975.1 0 NOTE: WOOD DOOR COMPONENTS: PINE OR OAK (SG >=0.42) SHEET 11 OF 11 BILL Of MATERIALS BILL OF MATERIALS ITEM DESCRIPTION MATERIAL ITEM DESCRIPTION MATERIAL A 1X BUCK SG >= 0.55 WOOD 50 FIBERGLASS DOOR PANEL W/STEEL REINFORCEMENT FIBER CLASSIC FIBERGLASS B 2X BUCK SG >= 0.55 WOOD 51 FIBER CLASSIC DOOR SKIN .065"MINIMUM THK. FIBERGLASS FIBERGLASS C MAX.1 /4"SHIM SPACE - 52 TOP RAIL COMP. D 1 /4" X 2-3/4" PFH ELCO CONCRETE SCREW STEEL 54 HINGE STILE LVL/WOOD E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 55 BOTTOM RAIL COMP. 57 LOCK STILE LVL/WOOD F 1/4" X 1-3/4"PFH ITW CONCRETE SCREW STEEL 60 FIBERGLASS DOOR PANEL W/STEEL REINFORCEMENT (CLASSIC CRAFT FIBERGLASS G 3/16" X 3-1/4"PFH ITW CONCRETE SCREW STEEL 61 CLASSIC CRAFT DOOR SKIN .090"MINIMUM THK. FIBERGLASS FIBERGLASS H 1 /4" x 3-1 /4"PFH ITW CONCRETE SCREW STEEL 62 TOP RAIL COMP. I 1/4"X2-1/4"PFHITWCONCRETESCREW STEEL 64 HINGE STILE WOOD J 1 /4" X 3-3/4" PFH ITW CONCRETE SCREW STEEL 65 BOTTOM RAIL COMP. K #8 X 2-1/7' PFH WOOD SCREW STEEL 67 LOCK STILE LVL/WOOD L # 10 X 2-1 /2"PFH WOOD SCREW 1.15"MIN. EMBEDMENT STEEL 70 FIBERGLASS DOOR PANEL W/STEEL REINFORCEMENT (CLASSIC CRAFT RUSTIC FIBERGLASS 1 EXTERIOR LITE FRAME ALUM. 71 CLASSIC CRAFT RUSTIC DOOR SKIN .090" MINIMUM THK. FIBERGLASS FIBERGLASS 2 INTERIOR LITE FRAME ALUM. 72 TOP RAIL COMP. 3 LITE FRAME TRIM PVC 75 BOTTOM RAIL COMP. 4 #10 X 1-1/2"PFH SM SCREW STEEL 77 HINGE AND LOCK STILE WOOD 7 MEDIUM REACH COMPRESSION WEATHER-STRIP FOAM 8 LONG REACH COMPRESSION WEATHER-STRIP FOAM 9 4" X 4'HINGE .09T' THK. STEEL 10 # 10 X 3/4"PFH WOOD SCREW HINGE TO FRAME STEEL 14 THRESHOLDOUTSWING -SELF ADJUST ALUM./COMP. 15 THRESHOLD OUTSWING - 5-3/4"COMPOSITE SILL ALUM./COMP. 16 THRESHOLD OUTSWING-5-3/4" COMPOSITE SILL ALUM./COMP. 17 PASSAGE LOCK - KWIKSET (SIGNATURESERIES STEEL 18 THRESHOLD OUTSWING 5-3/4"THERMAL BREAK SILL ALUM./WOOD 19 HEADER JAMB SG >= 0.42 WOOD . 20 SIDE JAMB SG >= 0.42 WOOD 21 KWIKSET DEADBOLT (SIGNATURE SERIES 980 STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT PLATE STEEL 31 COASTAL OUTSWING THRESHOLD ALUM./WOOD 32 DOOR BOTTOM SWEEP PVC 33 INSWING ADJUSTABLE THRESHOLD- STANDARD SUBSTRATE ALUM./COMP. 34 OUTSWING THRESHOLD- 5-3/4"HARDWOOD SILL ALUM./WOOD 35 7/16"X 1/2"STAPLE STEEL 36 INSWING THRESHOLD- FIXED STANDARD SUBSTRATE ALUM./COMP. 37 OUTSWING THRESHOLD ALUM./COMP. 38 INSWING ADJUSTABLE THRESHOLD- FULL SUBSTRATE ALUM./COMP. 39 PANEL REINFORCEMENT 0.023"THK. STEEL 40 FIBERGLASS DOOR PANEL W TEEL REINFORCEMENT SMOOTH STAR FIBERGLASS 44 HINGE STILE WOOD 45 BOTTOM RAIL COMP. 46 INSULATING FOAM CORE POLYURETHANE 47 LOCK STILE LVL/WOOD 48 TOP RAIL COMP. 49 SMOOTHSTAR DOOR SKIN .070"MINIMUM THK. FIBERGLASS FIBERGLASS