HomeMy WebLinkAboutProject Information, wind load chart Broward County Fenestration Voluntary Wind Load Chart* Per ASCE 7-16 Part 1 and FBC(2020)for Retrofitting in Accordance with Formal Interpretation#24 For Detached One-and Two family dwellings and Multiple Single-Family Dwellings(Townhouses)with Mean Roof Height:5 30 feet Wind 170 mph(3-second gust)/Exposure C**/Kd=0.85/Kzt=1.0/Pressures are in PSF/Not for use in Coastal(Exposure'D'areas) * Using Allowable Stress Design methodology(P=0.6w)/** Exposure C or D shall be determined according to ASCE 7-16 Section 26.7(Exposure Categories) Roof and Wall Zone Chart Diagrams Wall Pressure Chart Flat Roof Uplift Chart Gable Roof Uplift Chart Hip Roof Uplift Chart 46 a a a -,--- }-l-- r 3 c5 ! i t, 0i0; (p 'Otfl { s 0 !'p '� C� t } JI fl s4J fit. 0. '10 i i ' 0.6h a a 1 I I 1 1 I ��„ 4♦ ! a.�I�l 1 �I L'NATION PLAN a I PLAN Instructions on how to use these Charts: Determine Mean Roof Height,h,which is top of roof for flat roofs or the mean roof height for pitched roofs. Find your least horizontal dimension for your building,not including a overhang if it occurs. Calculate the value of,a,=10%of least horizontal dimension or 0.4*h,whichever is smaller,but not less than either 4%of least horizontal dimension or 3 feet.If your roof height is less than 30 feet, but not exactly 15,20,or 25 feet,you will need to go to the next higher roof height.If your Mean Foof Height is higher than 30 feet,these charts do not apply. Review the diagram which illustrate the wall and roof zones and determine the wind zone in which the component is located. Determine the tributary area of the component.If the tributary area falls in between values,use the value of the smaller tributary area. Select the positive and negative wind pressures corresponding to the wall or roof zone where your component is located. Door pressures shown are for the most common door sizes and are worst case for heights<=30 Feet. Wall Pressure For All Roof Types Garage/Door Pressures Mean Roof HeightM1,5 Ft 20 Ft <=30 Ft Tributary Area 50 100 500 10 20 35 50 100 500 Effective Wind AreaWall Positive Pressure34.0 32.3 28.3 40.3 38.5 37.0 36.1 34.3 30.1 Width Height sitive Negative Zone 4 Negative Pressure -37.2 -35.5 -31.5 -43.7 -41.9 -40.5 -39.5 -37.7 -33.5 8 8 38.6 -48.2 Zone 5 Negative Pressure -42.9 -39.5 -31.5 -54.0 -50.4 -47.4 '-45.6 -41.9 -33.5 10 10 37.4 -45.7 Mean Roof Height -- 2 Ft 30 Ft 14 14 35.4 -41.8 Tributary Area 10 20 35 50 100 500 10 20 35 50 100 500 9 7 - 38.7 =48:3 = Wall Positive Pressure 42.3 40.4 38.8 37.8 35.9 31.5 43.9 41.9 40.3 39.3 37.3 32.8 16 7 37.0 Zone 4 Negative Pressure -45.8 -43.9 -42.4 -41.4 -39.5 -35.1 -47.6 -45.7 -44.1 -43.1 -41.1 -36.5 3 7 41.8 Zone 5 Negative Pressure -56.6 -52.8 -49.7 -47.8 -43.9 -35.1 -58.8 -54.7 -51.7 -49.6 -45.7 -36.5 6 7 39.8 Page 2 of 3 BORA Policy 20-01 BROWARD COUNTY UNIFORM RETROFIT WINDOW & DOOR SCHEDULE PAGE 1 OF 1 NAME:Langlois, Alex & Amber SITE ADDRESS:6705 Santa Clara Blvd CONTACT#:(954) 635-0324 1 2 3 4 5 6 7 8 9 10 PRODUCT REQUIRED OPENING HAS NEW MULLION APPROVAL ZONE Impact DESIGN OPENING SIZES EXISTING SHUTTERS TUBES OPENING PRODUCT PRESSURE PRESSURE LOCATION Glazing SHUTTERS REQUIRED REQUIRED LOCATION ACCEPTANCE -- -- RATING _ ID NUMBER (+)PSF (-)PSF (+) PSF (-)PSF WIDTH X AREA IN 4 5HEIGHT SQ FEET INTER END YES NO YES NO YES NO YES NO IN INCHES 1 20-1103.09 55 55 38.0 50.8 37 x 35 8.9.91w/ 2 20-1103.09 55 55 34.9 44.6 73x61 30.9 3 20-1103.06 55 55 38.0 50.8 36 x 17 4.25 4. 20-1103.09 55 55 34.9 44.6 73x4.9 24.84 ✓ ✓ ✓ ✓ 5 20-1103.06 55 55 36.2 47.4 25x61 10.59 ✓ ✓ ✓ ✓ ✓ 6 20-1103.09 55 55 34.9 44.6 50x 61 21.18 ✓ ✓ 7 20-1103.06 55 55 -36.2 47.4 25x61 10.59 ✓ ✓ x x x IDENTIFY OPENINGS ALPHABETICALLY OR NUMERICALLY ON ELEVATION SHEETS. IDENTIFY VERTICALLY STACKED GLASS IN THE SAME OPENINGS FROM BOTTOM TO TOP WITH SUB NUMBERS(Example:A,Al,A2, ETC.).