HomeMy WebLinkAboutEVERHARD, WILLIAM_SUBMISSION PACKET - SIGNED PEC012221DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 STRUCTURAL CALCS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-5.4 ATTACHMENT PLAN 5.4 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXMODULE DATASHEET ARRAY WIRING BOX DATASHEET ARRAY WIRING BOX DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER EVERHARD PROPERTY ADDRESS 4305 REDWOOD DR, FORT PIERCE, FL 34951 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF FORT PIERCE UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2018 NFPA 1 OTHER BUILDING CODES 2020 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY ENERGY SOLUTIONS DIRECT LICENSE NUMBER CBC1260807 ADDRESS 7965 9TH AVE S, ST. PETERSBURG, ST. PETERSBURG, FL 33707 PHONE NUMBER (800) 425-1175 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 11.52KW AC RATING OF SYSTEM 8.64KW AC OUTPUT CURRENT 36.0A INVERTER(S)36 X ENPHASE IQ7-60-2-US MODULE AXITEC AC-320MH/120S ARRAY WIRING (3) BRANCH OF 12 IQ7-60-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1Φ SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 165 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY C GROUND SNOW LOAD 0 PSF P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951PROJECT SUMMARY DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-1 THIS ITEM HAS BEEN SIGNED AND SEALED BY PEDRO CRUZ, PE ON 22-JAN-2021 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED IS NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED IN ANY ELECTRONIC COPIES. GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (N) AC COMBINER, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFNC CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE ROADWAY (N) VISIBLE, LOCKABLE, READILY-ACCESSIBLE AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER, OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR (E) UTILITY METER, OUTDOOR (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 17 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 90° AZIMUTH (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 13 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 180° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 3 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 3 PV MODULES (SILVER FRAME, CLEAR BACKSHEET), 180° AZIMUTH ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951SITE PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-2 REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE:GRID-TIED SOLAR POWER SYSTEMFORT PIERCE, FL 349514305 REDWOOD DRPV-3 P-152525 01/22/21 P.C. SDT 152525 SINGLE-LINE DIAGRAMEVERHARD RESIDENCENOTES: 1. ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM AS PER NEC 690.12. 2. ALL LINES TO HAVE TERMINATOR AND SEALING CAP INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. 3. LIMITATIONS & LIABILITIES: ENGINEER OF RECORD DOES NOT MAKE ANY WARRANTY, EXPRESS OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ENERGY PRODUCTION PERFORMANCE OF THIS SOLAR PHOTOVOLTAIC (PV) SYSTEM. METER N G NO.1 VARIES NEUTRAL BONDED TO GROUND #6 AWG BARE COPPER GEC TO EXISTING GROUNDING ELECTRODE NEC 250.64(B) (3)3) #6 AWG THHN/THW (1)1) #10 AWG THHN/THWN-2 (E 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. (3)3) #6 AWG THHN/THW 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. PV - AC DISCONNECT LOCKABLE FUSED 60A OR 100A 240V 2-POLE 45A RK-1 FUSE (6) #10 AWG THHN/THW (1)1) #10 AWG THHN/THWN-2 (E 3/4" EMT, FMC,PVC, LFMC, LFNMC CONDUIT. SOLADECK 600V NON-FUSED OR NEMA 3R PVC ROOFTOP JUNCTION BOX L1 L2 N G LEGEND (36 @ 3 BRANCHES OF 12 MODULES) AXITEC 320MH 120S W/ENPHASE IQ7-60--2-US MICRO INVERTER. TYP. ENPHASE Q CABLE (3) CIRCUITS OF L1 & L2 (1)1) #6 AWG ENPHASE IQ AC COMBINER PANEL (3) 20A BRK (1)1) 10A BRK FOR IQ EN MONITORING DEVICE 20A 20A SUPPLY SIDE ELECTRICAL NOTES: 1. ALL WORK TO MEET OR EXCEED NEC 2017 REQUIREMENTS 2. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT PRESENTED IN THIS DOCUMENT SHALL COMPLY WITH MANUFACTURERS RECOMMENDATIONS, SPECIFICATIONS AND COMPLY WITH ALL CODES, STATUTES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. 3.INTERCONNECTION VIA SUPPLY SIDE CONNECTION AS PER NEC 705.12(A) USING PARALLEL TAPS IN A NEMA 3R BOX (AS REQUIRED) USING NSI IPCS 4002, ILSCO KUP-L-TAP INSULATION PIERCING CONNECTORS, OR EQUIVALENT. 4.PV DISCONNECTING MEANS FOR SUPPLY SIDE CONNECTION MUST HAVE NEUTRAL/EGC BOND WITHIN AND MUST BE LISTED AS “SUITABLE FOR USE AS SERVICE EQUIPMENT” NEC 230.66. 5.ROOFTOP JUNCTION BOX MUST BE MINIMUM NEMA 3R UL LISTED ENCLOSURE. FREE AIR CONDUCTORS MUST BE INSTALLED IN RACEWAY OR GUARDED, IF READILY ACCESSIBLE AS PER NEC 690.31(A). 6. THE FOLLOWING LABEL IS REQUIRED ON METER CAN AND PANEL BOARD: “WARNING: DUAL POWER SUPPLY. SOURCES: UTILITY GRID AND PV POWER SOURCE ELECTRIC SYSTEM” AS PER NEC 705.12(D)(3). 7. THE PV AC DISCONNECTING MEANS SHALL BE MARKED TO IDENTIFY AS THE: “PV SYSTEM DISCONNECT” AS PER NEC 690.13(B) 8. “PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN” LABEL REQUIRED ON PV SYSTEM DISCONNECT MEANS AS PER NEC 690.12(4) & 690.56(C). 9. “WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.” REQUIRED ON PV SYSTEM DISCONNECTING MEANS AND THE INVERTER AS PER NEC 690.17(E). 10. ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(B). 11. ALL COMPONENTS TO BE GROUNDED AS PER NEC 690.43. 12. PVC CONDUITS SHALL NOT BE USED IN TEMPERATURES EXCEEDING 122 FAHRENHEIT 36ARATED AC CURRENT: NOMINAL AC VOLTAGE: 240V LOCATIONS: PV DISCONNECTING MEANS, MAIN PANEL BOARD, & AC COMBINER PANEL LOCATIONS: PV DISCONNECTING MEANS LOCATIONS: MAIN PANEL BOARD & UTILITY METER CAN LOCATIONS: MAIN PANEL BOARD & UTILITY METER CAN IN CASE OF EMERGENCY, CONTACT ENERGY SOLUTIONS DIRECT AT 1-800-425-1175 45A METER GEC OUTSIDE INSIDE 1. OPTIONAL LOAD SIDE CONNECTION: WHEN FEASIBLE, PER NEC SECTION 705.12(D). OTHERWISE, BUSBAR MUST BE UPGRADED TO 200A 2. WARNING LABEL Allowable load side connection Busbar Rating Main Breaker Size (Bus Rating *1.2)-Main Break Size #8 AWG THWN (2) HOT (1) NEUTRAL (1) #10 AWG EGC in 3/4" PVC Conduit OPTIONAL LOAD SIDE CONNECTION PV - AC DISCONNECT LOCKABLE FUSED 60A 240V 2-POLE 45A RK-1 FUSE 200A 150A 90A 20A 20A BACKFEED BREAKER SHALL BE LOCATED OPPOSITE END FROM MAIN BREAKER PROTECTING THE BUSBAR WARNING: DO NOT RELOCATE THIS OCPD 20A 20A 10A 10A P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951STRUC. CALC DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 16.7FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.6 FT = MAX(MIN(0.4 * 16.7 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.1 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 14.4FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.7 FT = MAX(MIN(0.4 * 14.4 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.2 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 16.7FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 6.6 FT = MAX(MIN(0.4 * 16.7 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.3 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 14.4FT DECK SHEATHING 23/32" (3/4" NOM.) PLYWOOD CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL AXITEC AC-320MH/120S DIMENSIONS (AREA) 65.9IN X 39.1IN X 1.4IN (17.9 SQ FT) WEIGHT 40.8LB WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.7 FT = MAX(MIN(0.4 * 14.4 FT, 0.1 * 65.8 FT), 0.04 * 65.8 FT, 3 FT) P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-5.4 MOUNTING SYSTEM PROPERTIES RAIL MODEL IRON RIDGE XR10 ANCHOR MODEL EVERESTEVERFLASH FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951ATTACHMENT DETAILS DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-6 I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING. TYPICAL PORTRAIT LAYOUT NOT TO SCALE 48" O.C. MAX. TYPICAL LANDSCAPE LAYOUT NOT TO SCALE 48" O.C. MAX. STRUCTURAL NOTES: 1.THIS PLAN MAY BE USED WITH ANY MODULE APPROVED BY AN NRTL (NATIONALLY RECOGNIZED TESTING LABORATORY), AXITEC, CANADIAN SOLAR, SOLAR WORLD AMONG OTHERS. 2. THE SOLAR EQUIPMENT INSTALLED WILL ADD LESS THAN 4 PSF GRAVITY LOAD TO THE EXISTING STRUCTURE. PANELS TO BE INSTALLED ON ROOF PRESSURE ZONE 1. 3. THERE SHALL BE PV-TO-RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE GROUNDING CLAMPS. CONTRACTOR SHALL FURNISH END CLAMPS OF CHOICE. 4. MODULES MAY BE INSTALLED IN LANDSCAPE OR PORTRAIT ORIENTATION AS PER CONTRACTOR OPTION. 5. MODULES WILL BE ATTACHED TO ROOF USING A EVEREST EVERFLASH MOUNTING SYSTEM ALONG WITH IRON RIDGE XR10 RAIL AND UFO COUPLINGS. 6. CONTRACTOR SHALL ENSURE CONTINUITY OF ALL METAL PARTS AND CONNECTIONS OF THIS INSTALLATION TO BE ELECTRICALLY GROUNDED AND BONDED TOGETHER AS REQUIRED. 7. CONTRACTOR SHALL PROVIDE AHJ ANY OTHER INFORMATION AS REQUIRED. 8. DESIGNED AS PER FBC 2020. FLORIDA BUILDING CODE (7TH EDITION). 9. DRAWINGS MAY NOT REFLECT FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION. 10. CONTRACTOR MAY LOCATE PV MODULES IN OTHER LOCATIONS AND/OR ORIENTATION BUT SHALL NOT PLACE PV MODULES IN WIND ZONE 3. EVERFLASH COUPLING ASSEMBLY (TYP.) EVEREST - EVERFLASH MOUNT (TYP.) EVEREST - EVERFLASH MOUNT (TYP.) EVERFLASH COUPLING ASSEMBLY (TYP.) EVEREST - EVERFLASH MOUNT (TYP.) PV SYSTEM. SEE PV-1. (TYP.) PV SYSTEM. SEE PV-1. (TYP.) PV SYSTEM. SEE PV-1. (TYP.)TYPICAL METAL ROOF ATTACHMENT NOT TO SCALE (FOR VISUAL EFFECTS ONLY; ALWAYS INSTALL PER MANUF. SPECS) NOTE: PROPRIETARY GEOMETRIES HAVE BEEN REMOVED FROM THE CROSSRAIL 48-X PROFILE. MAJOR DIMENSIONS HAVE REMAINED THE SAME. PV MODULE M10 SERRATED HEX NUT M10 T-BOLTM10 T-BOLTM10 SERRATED HEX NUT EVEREST SLOTTED L-FOOTEVERFLASH eCOMP SLIDE BRACKETEVERFLASH LAG BOLT WASHER EVERFLASH eCOMP FLASHING ASPHALT SHINGLES ROOF DECK LAG BOLT EMBEDDED INTO TRUSS STRUCTURAL MEMBER LOCK WASHERMID CLAMP M8 ALLEN BOLT SPRING SHARED RAIL ADD-ON MK3 SLOT NUT CROSSRAIL 48-X GENERAL NOTES 1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO REDUCED OR MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTNERATIVE METHODS THAT ENSURE ADEQUATE FIRE DEPARTMENT ACCESS, PATWAYS, AND SMOKE VENTILATION. (NFPA 1 11.12.2.2.1) 2 NOT LESS THAN TWO 36 IN. (914 MM) WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 36 IN. (914 MM) WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (NFPA 1 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING UP TO 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM 18 IN. (457 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. FOR PV ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM OF 36 IN. (914 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (NFPA 1 11.12.2.2.2.2) ROADWAY PV MODULES INSTALLED ON ROOF WITH EVEREST CROSSRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 6/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1, 2, OR 3 MODULES. THE AXITEC AC-320MH/120S IS TYPE 1. 1.5 FT. WIDE FIRE ACCESS PATHWAY ROOF ACCESS POINT 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 TOTAL PLAN VIEW ARRAY AREA IS 586.5 SQ.FT, WHICH REPRESENTS 14.1% OF TOTAL PLAN VIEW ROOF AREA (4170.4 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-152525 GRID-TIED SOLAR POWER SYSTEMEVERHARD RESIDENCE4305 REDWOOD DRFORT PIERCE, FL 34951FIRE SAFETY PLAN DOC ID:152525-188037-0 DATE:1/22/21 CREATOR: REVIEWER:P.C. REVISIONS PV-7 Fig. similar 120MHUSA190621AAXIpremium HC120 cell monocrystallineHigh performance solar moduleGerman engineered – made for AmericaAxitec-Soft-Grip-Seam aluminum frame Higher stability and easier handlingSoft Grip15 years manufacturer’s warranty Five more years than industry standardSnow load of up to 113 psf Stable module for a long life in extreme conditions100 % electroluminescence inspection Micro crack and hotspot free modulesHigh quality junction box and connector system for a longer life timeYears15100%Positive power tolerance from 0-5 Wp Higher guaranteed yield WpHighest module performance throughHalf-Cut-technology and tested materials113 PSFExclusive linear AXITEC high performance guarantee!• 15 years manufacturer‘s guarantee on 90 % of the nominal performance• 25 years manufacturer‘s guarantee on 85 % of the nominal performanceAXITEC Warranty Added Value!warranted module performance100%97%90%85%80%85%80%1510 15 20 25Years0%commercial level warranty1 - 8 % more power after 25 yearsAC-285M/156-60S AC-290M/156-60SAC-295M/156-60S 310 - 320 Wp• 15 years manufacturer‘s guarantee on 90 % of the nominal performance • 25 years manufacturer‘s guarantee on 85 % of the nominal performanceHCIP 67(PHOTOVOLTAIC MODULE OVER 600 VOLTS) 5JK4E487509DesignFrontside 0.13 inch (3.2 mm) hardened, low-reflection white glass Cells 120 monocrystalline high efficiency cells Backside Composite film Frame 1.38 inch (35 mm) silver aluminium frame Mechanical dataL x W x H 65,94 x 39.06 x 1.38 inch (1675 x 992 x 35 mm) Weight 40.79 lbs (18.5 kg) with frame Power connectionSocket Protection Class IP67 Wire 43.3 inch, AWG 11 Plug-in system Plug/socket IP67 All dimensions in inchTechnical data are subject to change without prior notice, errors excepted.The measurement tolerances are +/-3%Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversionPmpp Umpp Impp Isc Uoc efficiencyAC-310MH/120S 310 Wp 32.74 V 9.47 A 9.96 A 40.01 V 18.66 %AC-315MH/120S 315 Wp 32.97 V 9.56 A10.03 A 40.13 V 18.96 %AC-320MH/120S 320 Wp 33.21 V 9.64 A10.11 A 40.25 V 19.26 %Electrical data (at standard conditions (STC) irradiance 1000 watt/m2, spectrum AM 1.5 at a cell temperature of 25°C) AC-285M/156-60S AC-290M/156-60SAC-295M/156-60SAXIpremium HC 310 - 320 WLimit valuesSystem voltage1000 VDC (UL) 1000 VDC (IEC) Module Fire PerformanceTYPE 1 (UL 1703) or CLASS C (IEC 61730) NOCT (nominal operating cell temperature)* 45°C +/-2K Max. load-carrying capacity 113 PSF Reverse current feed IR 20.0 APermissible operatingtemperature -40°C to 85°C / -40F to 185F(No external voltages greater than Vo may be applied to the module)* NOCT, irradiance 800 W/m2; AM 1.5; wind speed 1 m/s; Temperature 20°C Temperature coefficientsVoltage Uoc -0.29 %/K Current Isc 0.04 %/K Output Pmpp -0.39 %/KLow-light performance (Example for AC-310M/120S)I-U characteristic curve Current Ipp Voltage Upp 200 W/m2 1.90 A 32.15 V 400 W/m2 3.81 A 32.39 V 600 W/m2 5.68 A 32.50 V 800 W/m2 7.57 A 32.68 V1000 W/m2 9.47 A 32.74 VPackagingModule pieces per pallet 30 Module pieces per HC-container 78035942M1 86012001100M2 13602 x Ø 6,5grounding holes8 (Ø 6,5 x 10) mounting holes The Enphase IQ Combiner™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV installations by providing a consistent, pre-wired solution for residential applications.Enphase IQ Combiner(X-IQ-AM1-240-B)To learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Envoy for communication and control• Flexible networking supports Wi-Fi, Ethernet, or cellularSimple• Three pre-installed 20 A / 240 VAC circuit breakers• Provides production metering and optional consumption monitoring.Reliable• Durable NRTL-certified NEMA type 3R enclosure• Five-year warrantyTo learn more about Enphase offerings, visit enphase.com© 2017 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2017-08-17MODEL NUMBERIQ Combiner X-IQ-AM1-240-BIQ Combiner with Enphase IQ Envoy™ for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring (+/- 2.5%).ACCESSORIES (order separately)Enphase Mobile Connect™CELLMODEM-03 (4G / 12-year data plan)CELLMODEM-01 (3G / 5-year data plan)Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.)Consumption Monitoring CTCT-200-SPLITSplit core current transformers enable whole home consumption metering (+/- 2.5%).ELECTRICAL SPECIFICATIONSRatingContinuous dutySolar branch circuit breakersThree 2-pole 20 A/240 VAC DIN rail-mounted breakersMaximum system voltage240 VACRated output current48 ARated input current, each input16 AMaximum fuse/circuit breaker rating (output)60 AProduction Metering CT200 A solid core pre-installed and wired to IQ EnvoyMECHANICAL DATADimensions (WxHxD)38.0 x 38.7 x 20.3 cm (15.0” x 15.3” x 8.0”)Weight5.1 kg (11.2 lbs)Ambient temperature range-40º C to +46º C (-40º to 115º F)CoolingVented, natural convection, plus heat shieldEnclosure environmental ratingOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire size14 to 6 AWG copper conductors for branch inputs.14 to 4 AWG copper conductors for combined output.Follow local code requirements for conductor sizing.AltitudeTo 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nEthernet802.3, Cat5E (or Cat 6) UTP Ethernet cable - not included CellularOptional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) - not includedCOMPLIANCECompliance, CombinerUL 1741 Compliance, IQ EnvoyUL 916CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003IEC/EN 61010-1:2010,EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2Metering: ANSI C12.20 accuracy class 0.5Enphase IQ Combiner 567&(QWHUSULVHV,QF +HLPVWHDG5RDG (DX&ODLUH:, -- 2XWGRRU3KRWRYROWDLF(QFORVXUHV6HULHV(7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ ·8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV·&6$&1R1HPD7\SH5·&RQIRUPVWR8/6WDQGDUG&RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV ·3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO KRXUVVDOWVSUD\ ·6WDLQOHVVVWHHO3URFHVV-6HDPOHVVGUDZ VWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV %DVH3ODWH ·)DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP·URRIGHFNNQRFNRXWV·.QRFNRXWVL]HV  ´  ´DQG  ´·´PPVORWWHGGLQUDLO·*URXQG%ORFN6HULHV,QFOXGHV - :LUHVL]H- - :LUHVL]H- -' :LUHVL]H- DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters REVISIONSSEALSIGNATURESPECIFICATIONSSHEETS REVISIONSSEALSIGNATURESPECIFICATIONSSHEETS