HomeMy WebLinkAboutBlower door - duct leack• 0 Planning & Development Services 7PerM Building & Code Regulation Division �® 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 COUNTY772-462-2165 Fax 772-462-6443APR _ 4 2018 FBC ENERGY CONSERVATION CODE ittiDuct Sealing Certification n9 DeparPrescriptive and Performance MethodLucie Co tment �ntY, FL Date: Permit #: gTGGLot #: Contractor: CAW ► mrzc Address: & t 3jhL lbt(yz Construction: ebst Construction Test o Rough -in Test Test Conditions: Date: Lt2 Floor Area (ft2): Time: ID Primary Location of Supply Ductwork Indoor Temperature (F): Primary Location of Return Ductwork Outdoor Temperature (F): Total Leakage Test (Outside) Duct leakage: ❑ Default ❑ Prop. Leak Free Proposed On = Test Pressure: (Pa) Baseline Duct Pressure (optional) (Pa) ° ��S S�� Et �� Duct Press. Pa) Flow Ring Fan Press Flow (cfm) Results ass ❑ Fail Installed Total Leakage (cfm): Total Leakage per 100 sgft: t ` TeRt Ag-ts v Lr 104 CFM25 x 100 divided by the CFA = Duct Leakage CFNV100 sqft. Testing Company Company Name: GFA International, Inc. Address: 607 NW Commodity Cove, Port St. Lucie, Florida 34986 I hereby certify that the above Duct Se akage results demonstrate compliance with 5'1 Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Michael Anderson LicenselCertificate #: BPI 5059963 L7 Planning & Development Services Building & Code Regulation Division • • 2300 Virginia Ave, Rm 201 • Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 Date: Contractor: Job Address: Construction: BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method () New Construction — Complete ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = al Test Date: Volume = ?aA ..-).— ACH(50)=CFM(50)x6Volume = � Mechanical Ventilation required less than 5 ACH Passing results must be & ACH (50) or less _?Pass ( ) Fail FBC, Energy •The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. • FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: GFA International, Inc. I hereby certify that the a requirements in accordar Signature: Printed Name: Michael Anderson Address: 607 NW Commodity Cove, Port St. Lucie, Florida Infiltration results demonstrate compliance with FBC Energy Con�tion ion R402.4.1.2 Climate Zone 2. License/Certification #: BPI 5059963