Loading...
HomeMy WebLinkAboutProduct Approval- Mullions Honda molding lode Online .---rage I ul a File COPY -nW —S Home Log In User it-61 anon Hot Topic Submit Surcharge Stars&Facts Publications FBC Staff SCIS Site Map links Search Business Professional 4 product Approval A M USER:Public User y t���UidllUil Product approval Menu>Product or Application Search>Application List>Application Detail FL# FL15353-R2 Application Type Revision Code Version 2014 Application Status Pending FBC Approval Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florda Registered Architect Or a Licensed Florida Professional Engineer J Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Luis R Lomas,PE Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation&Management Institute Quality Assurance Contract Expiration Date 12/31/2015 Validated By Steven M.Unch,PE Validation Checklist-Hardcopy Received Certificate of Independence FL15353 R2 COI FLCOI.Odf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1710.5.3 n Product Approval Method Method 2 Option B (� Date Submitted 06/15/2015 Date Validated 06/15/2015 61,3 http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgtH8572q ISXrzuh... 7/ 4/2015 h londa Building lode Unitne rage z vi � Date Pending FBC Approval 06/,21/2015 u Summary of Products FL# Model,Numher or Name Description 15353.1 Horizontal Aluminum Mullion Limits of Use nstailation Instructions Approved for use in HVHZ:No FL15353 R2 it 08-01448A.Ddf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion span: FL15353 R2 AE 512072A..Ddf 52-1/8". _ Created by Independent Third Party:Yes 15353.2 15764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL35353 R2 If 08-01439A.odf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes !. Design Pressure:N/A Evaluation Reports Other:Max single window size:52-118'x 84".Max mullion span:83" FL15353 R2 AE 512063A.pdf Created by Independent Third Party:Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No - 15353 R2 11 09-01449A.,odf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion span: FL15353 R2 AE 512073A.pdr 104-1/4" Created by Independent Third Party:Yes 15353.4 15765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 11 08-01440A.Ddf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 ! Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion span:83". FL15353 R2 AE 512064A.DO Created by Independent Third Party:Yes 15353.5 CM-18514 Vertical Aluminum Mullion Limits of Use ---- Installation Instructions Approved for use in HVHZ:No FL15353 R2 it 08-01442A.i7df Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion length- FLI5353 R2 AE 512066A.pd{ 83". Created by Independent Third Party:Yes 15353.E CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ:No FL15353 R2 11 09-01451A.00f Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size-52-1/8"x 84".Max mullion span- FL15353 R2 AE 512075A.Ddf 104-1/4- Created by Independent Third Party:Yes 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01452koct' Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size-52-1/8"x 84'.Max mullion span- FL15353 R2 AE 512076A.pdf I 104-1/4". Created by Independent Third Party:Yes 15353.8 CM-18531 Vertical Aluminum Mullion Limits of Use Insitallartion Instructions Approved for use in HVHZ:No FLi5353 R2 11 08-01443A.odf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports other:Max single window size:52-1/8"x 84'.Max mullion span-83' FL'5351 R' AE 12067A.Ddr Created by Independent Third Party:Yes 15353.9 CM-18532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 11 08-01453A.00f Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size-52-118"x 84".Max mullion span- FL15353 R2 AE 512077 A.odf 104-1/4" Created by Independent Third Party:Yes 15353.10 CM-18533 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL16°r7,i P'' [[ 09-01444A.Ddf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8'x 84".Max mullion span:83' FL15353 R2 AE 511064A odf Created by Independent Third Party:Yes 15353.11 M-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ:No FI 1 S353 R2 11 06-01454A odf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84'.Max mullion span: F115353 R2 AE 512078A.odf 104-1/4'. Created by Independen[Third Pa :Yes httv://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDotH8 5 72 q vd W I SXrzuh... 7/24/2015 REMONS REv DESCMPi.ON DATE APPROVED A REVISED INSTALLATION DETAILS 06/10/15 R.L. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY ANCHORING NOTES: TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION SHEET 3. FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3, WITH 2 1/2' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS SHOWN IN INSTALLATION DETAILS SHEET 4. DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED 3) ALL FASTENERS TO BE CORROSION RESISTANT. UNDER SEPARATE APPROVAL. 4) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS WINDOWS AND DOORS, INC. LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. WINDOW OR DOOR UNIT. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE TYPE 1 (OR GREATER). UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS 5) TO ATTACH MULLION TO CLIP USE (4) #10 x 1 1/4" SELF ANCHORED AS SHOWN HEREIN. DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED HOLES FOR SCREWS ARE NOT PRE-DRILLED BY MANUFACTURER. IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = wt 2 w2 SIGNED.0611112015 MI WINDOWS AND DOORS \���s`1R 11 tloi � 650 WEST MARKET STREET ���\J\ '•E N• 4'9 i! GRATZ, PA 17030-0370 `.ter,•'\C S�•,c1'�� TABLE OF CONTENTS CM-18531 - VERTICAL MULLION =*�•/J�0,61261/X � SHEET NO. DESCRIPTION 83" MULLION SPAN GENERAL t07- w GENERAL NOTES O0, SSTATEE OF �+, 1 NOTES DRAWN: DwC NO. REV 'cFS 2 CONFIGURATIONS AND DP CHART ��E DATE 08 01443 A i,S�ONA;I�a���\ 3 INSTALLATION DETAILS NTS O1/11/12 1 OF 3 r 52 1/8" 104.25" REVISIONS MAX. UNIT WIDTH MAX. UNIT WIDTH REv DESCRIRTRNI DATE AP- (MULLION SPAN) (MULLION SPAN) A REVISED INSTALLATION DETAILS 06/11/15 R.L. H 1 WINDOW H1 WINDOW NOTES: 168" I 168" 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO L MAX. COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. MAX COMBINED COMBINED 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND HEIGHT HEIGHT H2 WINDOW WINDOW ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. H2 WINDOW FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION Maximum design pressure capacity chart FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. Maximum design presssure 50 Tributary Mullion Span and individual unit width(n) 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS Tributary Mullion span(In) Height 36.00 48.00 60.00 7200 84.00 96.00 104.25 PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3 height 18.00 24.00 30.00 36.00 42.00 48.00 52.13 (In) 1&00 24.00 30.00 36.00 4200 46.00 5213 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS 18.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 18.00 130.0 130.0 130.0 130.0 117.7 78.4 61.0 DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE 24.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 24.00 130.0 130.0 130.0 130.0 89.9 59.7 46.4 APPROVED UNDER SEPARATE APPROVAL. 30.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 30.00 130.0 130.0 130.0 118.7 73.4 48.5 37.6 6) SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN 36.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 36.00 130.0 130.0 130.0 101.8 62.5 41.2 31.9 IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE 42.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 4200 130.0 130.0 130.0 89.9 54.9 36.0 27.8 MANUFACTURED BY MI WINDOWS AND DOORS 48.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 48.00 130.0 130.0 1 130.0 81.2 49.3 322 24.8 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE 54.00 130.0 130.01 130.0 130.0 130.0 130.0 130.0 54.00 130.0 130.0 124.7 74.5 45.0 29.3 225 LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL" 60.00 130.0 130,01 130.01 130.01 130.0 130.0 130.0 60.00 130.0 130.0 116.5 1 69.4 41.6 1 27.0 20.7 WINDOW UNIT. 66.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 66.00 130.0 130.0 109.9 65.4 38.9 25.1 19.2 8) VERTICAL MULLIONS ARE NOT PART OF THIS APPROVAL. VERTICAL MULLIONS USED TO MULL UNITS SIDE BY SIDE MUST HAVE 7200 130.0 130.0 130.0 130.0 130.0 130.0 130.0 72.00 130.0 130.0 104.0 62.2 36.8 23.6 18.0 SEPARATE APPROVAL. 78.00 130.0 1301O 130.0 130.0 130.0 130.0 130.0 78.00 130.0 130.0 98.7 59.6 35.0 22.3 17.0 9) FOR ADDITIONAL APPROVED CONFIGURATIONS SEE SHEET 2. 84.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 B4.00 130.0 130.0 93.9 57.2 33.6 21.3 16.1 LARGE AND SMALL MISSILE IMPACT,LEVEL D,WIND ZONE3 LARGE AND SMALL MISSILE IMPACT,LEVEL D,WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND 00 NOT INCLUDE FLANGE INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON TRIBUTARY HEIGHT= H1 + H2 PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 2 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. SIGNED:0611212015 MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. MI WINDOWS AND DOORS 51RIICo/ \\`\ /%i 650 WEST MARKET STREET tf9�i� GRATZ. PA 17030-0370 ` 1c,E 5765 HORIZONTAL MULLION *M- TAi 51 SINGLE, TWIN AND TRIPLE WITH TRANSOM TABLE OF CONTENTS ELEVATION AND GENERAL NOTES -�0OF SHEET NO. DESCRIPTION DRAWN: D.G NO REv 1: � 1, 2 ELEVATION, NOTES AND DESIGN PRESSURE CHARTS 5�E DATE 08 SHEET O E449 A 3 INSTALLATION DETAILS NTS 03/06/12 1 OF 3 "SIGNS 156 3/8" REV DESCRIPTION DATE APPROVED MAX. UNIT WIDTH�'�{ A REVISED INSTALLATION DETAILS 06/11/15 R.L. (MULLION SPAN) HI WINDOW 168" MAX. COMBINED 4 5/8" HEIGHT H2 WINDOW WINDOW Maximum design pressure capadfy than 0 t 29/32" 27/32" ri Tributary Mullion Span and individual unit width(in) Height 54.00 1 7Z00 90.00 108.00 126.00 144.00 156.38 �8" (n) 18.00 24.00 30.00 36.00 4ZOO 48.00 52.13 25/32" Afl 18.00 130.0 130.0 97.1 55.8 35.0 23.4 18.2 1 9/16" 0 13/16" 24.00 130.0 130.0 73.8 42.3 26.5 17.7 13.8 30.00 130.0 119.4 59.9 34.2 21.4 14.2 11.1 C 3 13/16" 36.00 130.0 101.5 50.7 28.9 18.0 12.0 6XO5 32" 42.00 130.0 89.0 44.2 25.1 15.6 10.3 3/8"--J 1•. / - 48.00 130.0 79.8 39.3 22.3 13.8 - 54.00 130.0 7Z8 35.6 20.1 12.4 - - SECT5768 CLIP 60.00 129.4 67.4 3Z7 18.3 11.3 - - ALUMINUM6063-T5.093'THICK 56.00 122.4 63.3 30.3 16.9 10.4 - - FOR WOOD FRAMING INSTALLATION 72.00 116.21 60.0 28.4 15.8 78.00 11os szz 26.9 14.8 SECT5765 MULLION 84.00 105.41 54.7 25.6 14.0 - - - 4 5/8" -{ ALUMINUM 6005-T5.125'THICK 73/16" 3" LARGE AND SMALL MISSILE IMPACT,LEVEL D,WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE 1 9/16" 0 25 32 SECT5768 CLIP 2X05/32" ALUMINUM 6063-T5.093'THICK FOR MASONRYVONCRETE INSTALLATION DESIGN PRESSURE TABLE INSTRUCTIONS: SIGNED:0611212015 2) DETERMINEOTRRBUOTARYSIGN HEIGHOT�ANDEMULL0RIDA 10N SPANILBING CODE A EO ON PRODUCT TO BE H1 + H2 16. M650IWDOWMARKEAND SDOORS \\�\\\S it I)to/// INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. RIBUTARY HEIGHT = 2 GRATZ, PA 17030-0370 r••�GENS' F 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE 5765 HORIZONTAL MULLION =*• 0 61 k INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND SINGLE, TWIN AND TRIPLE WITH TRANSOM - �� TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP ELEVATION AND COMPONENTS A, TAT OF tV` PRESSURE OBTAINED IN MULLION RATING MUST BSTEP UAL OR GREATER THAN REQUIRED DESIGN owC 08-01 449 RA '��o2. ii;P,-. ORI f��G\ ��` SCALE NTS I DATE 03/06/12 1 SHEET 2 OF 3 ��1lll ll 1111��\ REVISIONS REV DESCRIPTION DATE I APPROVED A REVISED INSTALLATION DETAILS 06/11/IS R.L. 1 3/8" b10 w00D MIN. EMBEDMENT MIN. EMBEDMENT SCREW 5765 MULLION SECT5768 CLIP 1/4" TAPCON as 2 1/2" INTERIOR 1/2" MIN. MIN. EDGE DISTANCE EDGE DISTANCE -- I WOOD FRAMING OR 2X BUCK i...............i i.......-....... BY OTHERS MASONRY/CONCRETE BY OTHERS a EXTERIOR I, MULLION INSTALLATION CLIP INSTALLATION ANCHORING NOTES: 1) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 - 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT -J LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT IN10 SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 TEK SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED INSTALLATION INSTRUCTIONS. SIGNED:0611212015 6) ALL FASTENERS TO BE CORROSION RESISTANT. 7) INSTALLATION NSTR ANCHORS UCTIONSALANDEANCHORS INSTALLED SHALLCNOTDBECUSEDHN ANCHOR TRATSIUWITHURERS M650IWDOWAREDSDOORS \`\\\\S1R11(0 //��� STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: GRATZ, PA 17030-0370 `ter•�\GENS�9�+%� A WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 5765 HORIZONTAL MULLION *• 0 5 # B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. SINGLE, TWIN AND TRIPLE WITH TRANSOM INSTALLATION DETAILS jo' TATE OF ;�� oRAwN� owc No. REV ii�.L�S'c[OR10P V.L.. 08-01449 ^ SCALE NTS DATE 03/06/12 1 SHEET OF 3 //I111111111��\ AF REVISIONS REV DESCRIPTION DATE APPROVED 15 NOTES: A REVISED INSTALLATION DETAILS 06/10/ R.L. 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY ANCHORING NOTES: TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION SHEET 3. FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH 4) APPROVED IMPACT PROTECTIVE SYSTEM 15 NOT REQUIRED FOR THIS SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS SHOWN IN INSTALLATION DETAILS SHEET 4. DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF DRILLING UNDER SEPARATE APPROVAL. SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI SCREWS IN ACCORDANCE WITH WINDOW ANCHORING SCHEDULE AS WINDOWS AND DOORS, INC. SHOWN IN WINDOW SEPARATE APPROVAL 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE 4) ALL FASTENERS TO BE CORROSION RESISTANT. LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH WINDOW OR DOOR UNIT. ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS, AND 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: ANCHORED AS SHOWN HEREIN. A WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TYPE 1 (OR GREATER). TO THIS DOCUMENT. 6) TO ATTACH MULLION TO CLIP USE (4) #10 x 1 1/4" SELF DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED. HOLES FOR SCREWS ARE NOT PRE—DRILLED BY MANUFACTURER. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2, MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W1 + 22 SIGNED:06/11/2015 MI WINDOWS AND DOORS \`\\51R!'�o�,,�� 650 WEST MARKET STREET \\J\ 419�i-GRATZ, PA 17030-0370 `r,•�\GENSF•en TABLE OF CONTENTS 5765 VERTICAL MULLION _*•OTA 51SHEET NO. DESCRIPTION 83" MULLION SPAN O FF ;�4� GENERAL NOTES 1 NOTES DRAWN: OWL N0. REV ���F 2 CONFIGURATIONS AND DP CHART SVcxLE 08 50 E440 A iiNALLE�\\�\ 3 INSTALLATION DETAILS NTS DATE 01/11/12 1 OF 3 AF REVISIONS 107 3/8' 707 3/8' 107 3/8" REv DESCRIPTION DATE AvrawEo COMBINED WIDTH T OMBINED WIDTH COMBINED WIDTH A REVISED INSTALLATION DETAILS 06/10/15 R.L. W1 -{�W2 W1 W2 A W2 FRAME FRAME 'WINDOW FRAME WINDOW WINDOW HEIGHT WINDOW WINDOW HEIGHT WINDOW HEIGHT (MULLION (MULLION (MULLION SPAN) ! / SPA ! ` SPA ` F'l 107 3/8" /. ! 107 3/8" / / 107 3/8" COMBINED WIDTH COMBINED WIDTH COMBINED WIDTH W2 / /W1� /� W2 /W1 W2 ` 83" / WINDOW / 83" WINDOW 83" WINDOW J FRAME / / FRAME / / FRAME WINDO W/NDO HEIGHT HEIGHT HEIGHT WINDO � WINDOW (MULLION (MULLION (MULLION SPA ` ` ` SPA ! ! ` SPAN) ! ! ` / W1 /-CIF--W2/ / W1 /--i - W2/ W1 /-^It- W2/ I- JL- -1111 1-- L- 11 1 1 1 L L107 3/8" 107 3/8" 107 3/8" 7A COMBINED WIDT14 COMBINED WIDTH COMBINED WIDTH APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 107"'AS SHOWN HEREIN. Design pressure rating(psO Mullion Tributary width(in) span fin) 18.13 25.50 36.00 4ZOO 48.00 5Z13 25.00 130.0 1 130.0 130.0 130.0 130.0 130.0 SIGNED:0611112015 37.38 130.0 130.0 130.0 130.0 130.0 130.0 49.63 130.0 130.0 130.0 130.0 130.0 130.0 MI WINDOWS AND DOORS ��111111r/Iiii 6ZOO 130.0 130.0 112.0 103.0 97.3 94.7 650 WEST MARKET STREET �� \r?R 0'11//, 65.63 130.0 130.0 103.5 94.7 88.8 86.0 GRATZ, PA 17030-0370 r•��GENSF.4��f� TZOO 130.0 117.4 91.3 82.8 77.0 74.1 84.00 t20.2 87.0 64.0 56.4 51.0 48.1 5765 VERTICAL MULLION _*• J�(0 psi LARGE AND SMALL MISSILE IMPACT,LEVEL D,WINDZONE3 83' MULLION SPAN �'�� i �� DIMENSIONS INCHARTARE FRAME DIMENSIONS AND DONOT APPROVED CONFIGURATIONS AND RATING CHART TAT OF y INCLUDE FLANGE DRAWN: Owc No. REV �i�'cFS'c(OR10t G�`\�� scu' NTS DATE 01/11/12 OS SHHET20OF 3 A ///�Sr�NIAii1���\\ REVISIONS 2 1/2" MIN. REV DESCRIPTION DATE APPROVED EDGE DISTANCE A REVISED INSTALLATION DETAILS 06/10/15 R.L. MASONRY/CONCRETE BY OTHERS a.. - 1 1/4" •° e_ MIN. EMBEDMENT I I � 0.212" 3.800" I I 1/4" TAPCON \ 1.725" SECT5768 CLIP ��II SECT5765MULLION F\\ ALUMINUM 6005-TS.125"THICK SECT5765 MULLION 4.624' �{ SECT5768 CLIP 1.891 L 0.843" #10 WOOD SCREW T 81" I 1.562" O O I I I - I 1 3/8" MIN. EMBEDMENT I II �� 0.375" 1.000" II ii� SECT5768 CLIP WOOD FRAMING/ � ALUMINUM 6063-T5.093'THICK 2X BUCK 1/2" MIN. ��l�.���i BY OTHERS EDGE DISTANCE VERTICAL CROSS SECTION SIGNED:0611112015 Al MASONRYAANCRETE AND WOOD FRAMING MI WINDOWS AND DOORS \\\\11111111, INSTALLATION 650 WEST MARKET STREET R•��'1f,9�i�� NOTES: GRATZ, PA 17030-0370 `v•*\G E M q •p 1) FOR FRAMING INSTALLATION USE ALL FOUR HOLES IN 5765 VERTICAL MULLION * 0/,�8�51 INSTALLATION CUP. 83" MULLION SPAN =off= 2) FOR MASONRY/CONCRETE INSTALLATION USE HOLES INSTALLATION DETAILS ��0, TAT OF tom` AT EACH END OF INSTALLATION CUP. INSTALL TWO ��,�••,� P 4` TAPCONS PER CLIP. DRAWN, DWD NO. REV ZORIID. CLIP INSTALLATION SSCALEvLE DATE 08 soE aao A /ii/sS/ONA`1E"���� NTS 01/11/12 3 OF 3 it I