HomeMy WebLinkAboutEnergy CodeFORM R4054017 ="
FLORIDA ENERGY EFFICIENCY- CODE FOR -BUILDING CONSTRUCTION
Florida'Department of Business and Professional Regulation'- Residential Performance Method
ProjectName: • _LARSEN RESIDENCE
BuilderName:
Street: SAEGER AVENUE
Permit Office: -ST. LUCIE COUNTY
City, State, Zip: FT; PIERCE, FL,,
PermitNumber:..
Owner: WAYNE LARSEN
Jurisdiction: 6611000
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate, Zone 2 )
1. New construction orexisting New (From Plans) =
P. Wall Types (5203.4 sgft.) . _
Insulation , Area.
2. Single family or multiple family Single-family
a. Frame -Wood, Exterior
R=21.0 4843.40 ft2
b. Frame - Wood, Adjacent
R=21.0_ 360.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (4000.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 4000.00 ft2
6. Conditioned floor.area above grade (ft2) 4989
b. N/A
R= ft2 _
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (822.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic,'AH: A/C
6 325
a. U-Factor: Sgl, U=0.32 515.03 ft2
b. Sup: Attic, Ret: Attic; AH: Room25
6 125
SHGC: SHGC=0.19
b. U-Factor: Sgl, U=0.87 128.00 ft2
12. Cooling systems
kBtu/Hr Efficiency
SHGC: SHGC=0.66
a. Central Unit
54.0 SEER:19.00
c. U-Factor: Sgl, U=1.70 120.67 ft2
b. Central•Unit
24.6 SEER:20.00 . .
SHGC: SHGC=0.28
13.Heatingsystems
_ kBtu/hr Efficiency
,d.,U-Factor: of. er(seedetails)' 58.60ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 7.600 ft.
Area Weighted Average SHGC: 0.271
14. Hot water systems
8. Floor Types (3958.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3319.00 ft2
b. Conservation features
EF:0.950
b. Floor over Garage R=30.0 639.00ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.165 Total Proposed Modified Loads: 115.22
PASS
Total Baseline Loads: 150'.64 .
I hereby certify that the plans and specifications covered by
Review of the plans and
TKE:ST+q��
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
*� nrntj''�� `•_�
PREPARED BY:
DATE: - -
Before construction is completed
this building will be inspected for
"` o
I y;
compliance with Section 553,908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.;
with the Florida Energy ode.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 1-7-7- 1 " /7
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.,
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with_R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4:1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.009 Qn for whole house.
9/1/2020 11:35 AMA EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8
FORM R405-2017 INF'U I SUMMAKY UMILU KLI, I KtF'UK I
PROJECT
Title:
LARSEN RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
ConditionedArea: 4989
Lot#'
OwnerName:
WAYNE LARSEN
Total Stories: 2
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
BuilderName:
RotateAngle: 0
Street:
SAEGER AVENUE
Permit Office:
ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
6611000
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType:
Single-family
FL,
New/Existing:
New (From Plans) "
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design
DailyTemp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer DegreeDays Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT#2
1565
15020
2
UNIT#1
3424
42511.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled Heated
1
DINING
286
2860 No
0
1
No
Yes
Yes
2
MASTER BEDROO
437
4370 No
0
1
1
No
Yes
. Yes
3
M BATH
186
1860 No
0
1
No
Yes
Yes
4
TILT
34
340 No
0
1
No
Yes
Yes
5
MASTER CLOSET
216
2160 No
0
1
No
Yes
Yes
6
BUTLER'S
54
540 -No
0
1
No
Yes
Yes
7
PANTRY
84
840 No
0
1
No
Yes
Yes
8
HALL.
72
720 No
0
1
No
Yes
Yes
9
KITCHEN
544
5440 Yes
0
1
No
Yes
Yes
10
LIVING
678
15051.6 No
2
1
No
Yes
Yes
11
HALL
127
1270 No
0
1
No
Yes
Yes
12
OFFICE
270
2700 No
0
1
No
Yes
Yes
13
ELEV
30
300 No
0
1
No
Yes
Yes
14
BATH 2
105
1050 No
0
1
No'
Yes
Yes
15
A/C
16
160 No
0
1
No
Yes
Yes
16
CABANA
81
810 No
0
1
No
Yes
Yes
17
UTILITY
99
990 „No
0
1
No
Yes
Yes
18
CLOSET
105
1050 No
0
1
No
Yes
Yes
19
BEDROOM 3
273
2730 No
2
1
1
No
Yes
Yes
20
CLST. 3
30,
300 No
0
1
No �
Yes
Yes
21
'BATH 3
45
450' No
0
1
No
Yes
Yes
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) -FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R4'05-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area
Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22
HALLWAY 60
600
No
0
1 No
Yes
Yes
23
BEDROOM 2 222
2220
No
0
1
1 No
Yes
Yes
24
Room25 18
180
No
0
9 No
Yes
Yes
25
BALCONY 197
1970
No
0
1 - No
Yes
Yes
26
BATH 5 90
900
No
0
1 No
Yes
Yes
27
STUDIO 630
5670
No
0
1 No
Yes
Yes
FLOORS
# FloorType Space
Perimeter Perim eterR-Va lue
Area
. JoistR-Value
Tile
Wood
Carpet
1 Slab-On-GradeEdge Insulation
DINING
22 ft
0
286 ft2
____
0
1
0
2 Slab-On-GradeEdge Insulation MASTER BEDRO
61 ft
0
437 ft?
____
0
1
0
3Slab-On-GradeEdge Insulation
M BATH
17ft
0
186ft2
____
0
1
0
4 Slab-On-GradeEdge Insulation
TLT
13 ft
0
34 ft2.
____
0
1
0
5Slab-On-GradeEdge Insulation MASTERCLOSE
1ft
0
216ft2
____
0
1
0
6 Slab-On-GradeEdge Insulation
BUTLER'S
6 ft
0
54 ft2
_ __
0
1
0
7Slab-On-GradeEdge Insulation
PANTRY
1 ft
0
84ft2
____
0
1
0
8Slab-On-GradeEdge Insulation
HALL.
1ft
0
72ft2
____
0
1
0
9 Slab-On-GradeEdge Insulation
KITCHEN
1 ft
0
544 ft2
____
0
1
0
10SIab-On-GradeEdgeInsulation
LIVING
52 ft
0
678 ft2
____
0
1
0
11SIab-On-GradeEdge Insulation
HALL
4ft
0
127ft2
____
0
1
0
12SIab-On-GradeEdge Insulation
OFFICE
22ft
0
270ft2
____
0
1
0
13Slab-On-GradeEdge Insulation
ELEV
1 ft
0
30 ft2
0
1
0
14Slab-On-GradeEdge Insulation
BATH 2
22 ft
0
1.05 ft2
____
0
1
0
�l
15SIab-On-GradeEdge Insulation
A/C
1 ft
0
16 ft2
____
0
1
0
16SIab-On-GradeEdge Insulation
CABANA
9ft
0
81 ft2
____
0
1
0
17Slab-On-GradeEdge Insulation
UTILITY
1 ft
0
99 ft2
____
0
1
0
18FlooroverGarage
BATH 5
____
____
9 ft2
30
0
1
0
19FlooroverGarage
STUDIO
____
____
612 ft2
30
0
0
1
20Floorover Garage
STUDIO
____
____
18 ft2
30
0
1
0
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017), Compliant Software Page 3 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF,
Roof
Gable
Roof, Red
Solar
SA Emitt
Emitt Deck
Pitch
v #
Type Materials Area
Area
Color Barr
Absor.
Tested Tested Insul.
(deg)
1
Hip Metal 4808 ft2
0 ft2 Unfinishe N
0.6
No 0.7
No 20
33.7
ATTIC
V #
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
4000 ft2.
N
Y
CEILING
#
CeilingType
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
UnderAttic(Unvented)
DINING
0
Blown
13ft2
0.1
Wood
2
UnderAttic(Unvented)
MASTER BEDRO
0
Blown'
437 ft2
0.1
Wood
3
UnderAttic(Unvented)
M BATH
0
Blown
.186ft2
0.1
Wood
4
UnderAttic(Unvented)
TLT
0
Blown
34ft2
0.1
Wood
5
UnderAttic(Unvented)
MASTER CLOSE
0
Blown
216ft2
0.1
Wood
6
UnderAttic(Unvented)
BUTLER'S
0
Blown
54 ft2
0.1
Wood
7
UnderAttic(Unvented)
PANTRY
0
Blown
84ft2
0.1
Wood
8
UnderAttic(Unvented)
HALL.
0
Blown
72ft2
0.1
Wood
9
UnderAttic(Unvented)
KITCHEN
0
Blown
32ft2
0.1
Wood
10
UnderAttic(Unvented)
LIVING
0
Blown
678ft2
0.1
Wood
11
UnderAttic(Unvented)
HALL
0
Blown
77ft2
0.1
Wood
12
UnderAttic(Unvented)
OFFICE
0
Blown
249ft2
0.1
Wood
13
UnderAttic(Unvented)
ELEV
0
Blown
5 ft2
0.1
Wood
14
UnderAttic(Unvented)
BATH
0
Blown
105ft2
0.1
Wood
15
UnderAttic(Unvented)
A/C
0
Blown
16ft2
0.1
Wood
16
UnderAttic(Unvented)
CABANA
0
Blown
72ft2
0.1
Wood
17
UnderAttic(Unvented)
'CLOSET
0
Blown
105ft2
0.1
Wood
18
UnderAttic(Unvented)
BEDROOM
0
Blown
273ft2
0.1
Wood
19
UnderAttic(Unvented)
CLST.3
0
Blown
30ft2
0.1
Wood
20
UnderAttic(Unvented)
BATH 3
0
Blown
45ft2
0.1
Wood
21
UnderAttic(Unvented)
HALLWAY
0
Blown
60ft2
0.1
Wood
22
UnderAttic(Unvented)
BEDROOM 2
0
Blown
222 ft2
0.1
Wood
23
UnderAttic(Unvented)
Room25
0
Blown
18ft2
0.1
Wood
24
UnderAttic(Unvented)
BALCONY
0
Blown
.197ft2
0.1
Wood
25
UnderAttic(Unvented)
BATH 5
0
Blown
90 ft2
0.1
Wood
26
UnderAttic(Unvented)
'STUDIO
0
Blown
630ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Belo w
Space
1 W
Exterior Frame -Wood
DINING
21 22
0 10 0
220.0ft2
0 0.25
0.8
0
2 E
Exterior Frame -Wood
MASTER BE
21 19
0 10 0
190.0ft2
0 0.25
0.8
0
3 S
Exterior Frame -Wood
MASTER BE
21 23
0 10 0
230.0ft2
0 0.25
0.8
0
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017.FBC 6th Edition (2017) Compliant.Software Page 4 of 8
FORM R405-2017 INPUT
iUMMARY CHECKLIST"::REPORT
4
W
Exterior
Frame -Wood
_ 5
N
Exterior
Frame -Wood
6
W
Exterior
Frame -Wood
_ 7
E
Exterior
Frame -Wood
8
S
Exterior
Frame -Wood
9
W
Exterior
Frame - Wood
10
W
Exterior
Frame, -Wood
11
N
Exterior
Frame -Wood .
_12
E
Exterior
Frame -Wood
13
S
Exterior
Frame -Wood .
14
N
Exterior
Frame -Wood
15
E
Exterior
Frame -Wood
16
N
Exterior
Frame -Wood
17
E
Exterior
Frame -Wood
18
W
Exterior
Frame -Wood
19
N
Exterior
Frame -Wood ,
20
E
Exterior
Frame -Wood
21
N
Exterior
Frame -Wood
22
S
Exterior
Frame -Wood
_23
W
Exterior
Frame -Wood
24
N
Exterior
Frame -Wood
25
E
Exterior
Frame -Wood
26
N
Exterior
Frame -Wood
27
E
Exterior
Frame -Wood
28.
S
Exterior
Frame -Wood
29
W
Exterior
Frame -Wood
_30
N
Exterior
Frame -Wood
31
_E
Exterior
Frame -Wood.
32
W
Exterior
Frame -Wood
_33
'N
Garage
Frame --Wood
# Ornt DoorType
1 N Insulated
WALLS
Cavity
Width
Height
Space
Et
In
Et
In
MASTER BE
21
19
0
10
0
M BATH
21
5
0
10
0
M BATH,
21
12
0
10
0
TLT
21
1
0
10
0
TLT
21
5
0
10
0
TLT
21
7
0
10
0
BUTLER'S
21
6
0
10
0
LIVING
21.
1
0
22
2
LIVING
21
15
0
22
2
LIVING
21
36
0
22
2
HALL
21,
4
0
10
0
OFFICE
21
22
0
10
0
BATH 2
21
15
0
10
0
BATH 2
21
7
0
10
0
CABANA
21
9
0
10
0
CLOSET
21
3
0
10
0
CLOSET
21
9
0
10
0
BEDROOM 3
21
8
0
9
0
BEDROOM 3
21
13
0
9
0
BEDROOM 3
21
21
0
9
0
BEDROOM 2
21
10
0
9
0
BEDROOM 2
21
15
0
9
0
BALCONY
21
8
0
9
0
BALCONY
21
1
0
9
0
BALCONY
21
33
0
9
0
BATH 5
21.
9
0
9
0
STUDIO
21,
20
0.
9
0
STUDIO
21
36
0__.
9
.0 ,_
STUDIO
21,
27.
0
9
0
LIVING-
21
36
10
DOORS
Space
Storms
U-Value
LIVING
None
.46
Sheathing Framing
Solar
Below
0
190.0 ft2
0,
0.25
0.8
0
50.0 ft2
0
0.25
0.8
0
120.0 ft2
0
0.25
0.8
0
10.0 ft2
0
0.25
0.8
0
50.0 ft2
0
0.25
0.8
0
70.0 ft2
0
0.25
0.8
0
60.0 ft2
0
0.25
0.8
0
22.2 ft2
01
0.25
0.8
0
333.0 ft2
0
0.25
0.8
0
799.2 ft2
0
0.25
0.8
0
40.0 ft2
0
0.25
0.8
0
220.0 ft2
0
0.25
0.8
0
150.0 W.
0,
0.25
0.8
0
70.0 ft2
G
0.25
0.8
0
90.0 ft2
0
0.25
0.8
0
30.0 W
0
0.25
0.8
0
90.0 ft2
0
0.25
0.8
0
72.0 ft2
0
0.25
0.8
0
117.0 ft2
0
0.25
0.8
0
189.0 ft2 ,
0
0.25
0.8
0
90.0 ft2
0
0.25
0.8
0
135.0 ft2
0
0.25
0.8
0
72.0 ft2
0
0.25
0.8
0
9.0 ft2
0
0.25
0.8
0
297.0 ft2
0
0.25
0.8.
0
81.0 ft2
0
0.25
0.8
0
180.0 ft2.,
0
0.25
0.8
0
324.0 ft2
0 -
0.25
0.8
0
243.0 ft2
0
0.25
0.8
0
366.0 ft2
0:23
0.600000
0
Width Height Area
Ft, .. In Ft In
3 8 24 ft2
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
i
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
W
1
Vinyl
Low-ESingle
Yes
0.87
0.66
Y
128.0 ft2
12 ft 0 in
1 ft 4 in
None
None
2
E
2
Vinyl
Low-ESingle
Yes
1.7
0.28
Y
24.0 ft2
8 ft 0 in
1 ft4 in
None
None
3
S
3
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
84.0 ft2
8 ft 0 in
1 ft4 in
None
None
4
W
6
Vinyl
Low-ESingle
Yes
1.7
0.28
Y
24.0 ft2
9 ft 0 in
1 ft 4 in
None
None
5
W
6
Vinyl
Low-ESingle
Yes
0.29
0.21
Y
6.3 ft2
9 ft 0 in
1 ft4 in
None
None
6
S
8
Vinyl
Low-ESingle
Yes'
0.32
0.19
Y
10.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
E
12
Vinyl
Low-ESingle
Yes
1.25
0.15
Y
16.0 ft2
8 ft 0 in
1 ft4 in
None
None
8
E
12
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
19.0 ft2
8 ft 0 iri
1 ft4 in
None
None
9
E
12
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
78.1 ft2
8 ft 0 in
1 ft 4 in
'None
None
10
E
12
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
S
13
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
39.1 ft2
8 ft 0 in
1 ft4 in
None
None
12
S
13
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
78.1 ft2
8 ft 0 in
1 ft4 in
None
None
13
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
16.0 ft'
2 ft 0 in
1 ft4 in
None
None
14
N
14
Vinyl
Low-ESingle
Yes
1.7
0.28
Y
24.0 ft2
8 ft 0 in"
1 ft 4 in
None
None
15
E
15
Vinyl
Low-ESingle
Yes
1.7
0.28
Y
24.0 ft2
8 ft 0 in
1 ft 4 in
None
None
16
E
15
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
19.0 ft2
8 ft 0 in
1 ft4 in
None
None
17
N
16
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
12.1 ft2
9 ft 0 in
1 ft 4 in
None
None
18
E
17
Vinyl
Low-ESingle
Yes
0.29
0.21
Y
6.3'ft2
9 ft 0 in
1 ft 4 in
None
None
19
W
18
Vinyl
Low-ESingle
Yes
1.7
0.28
Y
24.7 ft2
12 ft 0 in
1 ft 4 in
None
None
20
W
23
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
21
E
25
Vinyl
Low-ESingle
Yes
0.32
0.19
N
27.0 ft2
2 ft 0 in
1 ft 4 in
None
None
22
N
30
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
60.0 ft2
2 ft 0 in
1 ft 4 in
None
None
23
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.02
N
6.4 ft2
2 ft 0 in
1 ft 4 in
None
None
24
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.02
Y
7.3 ft2
2 ft 0 in
1 ft4 in
None
None
25
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.17
Y
8.3 ft2
2 ft 0 in
1 ft 4 in
None
None
26
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.19
Y
8.7 ft2
2 ft 0 in
1 ft 4 in
None
None
27
N
Skylt
Vinyl
Low-ESingle
Yes
0.32
0.02
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
FloorArea
CeilingArea
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
1008 ft2
1008 ft2
36 ft
loft
21
INFILTRATION
# Scope
Method.,
•
SLA
CFM 50
_ ELA
EgI-A
ACH
ACH 50,
1 Wholehouse
ProposedACH(50)
.000366
4794.3
263.2
494.99
.1939
5
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20.17 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT `
HEATING SYSTEM
# System Type
Subtype,
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
34 kBtu/hr
2
sys#1
2 Electric Strip Heat/
None
COP:1
17 kBtu/hr
1
sys#2
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 19
54 kBtu/hr cfm 0.7 2
sys#1
2 Central Unit/
Split
Single SEER:20
24.6 kBtu/hr cfm 0.7 1
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
--- Supply---
--- Return --
Air CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area LeakageType
Handler TOT
OUT QN RLF
Heat Cool
1 Attic 6 325 ft2
Attic
105 ftZ Proposed Qn
A/C --- cfm
0.0 cfm 0.00 - 6.50
1 1
2 - Attic - 6 = - 125 ft2 = Attic •
65 ft2 Prop. Leak Free
Room25 - --- cfm - 47.0 cfm -0.03 - 0.50 2 2
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Coolin Jan [[ ]] Feb Mar
Heating HJan [X] Feb Mar
Apr
E Apr
Ma Jun Jul
May Jun Jul
I
Auge
AuSeP
Oct Nov
Oct Nov
Dec
Dec
Ventin Jan [[ ]] Feb X Mar
[X] A r
May Jun Jul
Aug Se
Oct X Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType 1
2 - 3
4 5 6
7 8
9 10 11
12
Cooling(WD) AM 78
78 78
78 78 78
78 78
80 80 80
80
PM 80
80 78
78 78 78
78 78
78 78 78
78
Cooling(WEH) AM 78
78 78
78 78 78
78 78
78 78 78
78
PM 78
78 78
78 78 78
78 78
78 78 78
78
Heating (WD) AM 66
66 66
66 66 68
68 68
68 68 68
68
PM 68
68 68
68 68 68
68 68
68 68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68 68
68 68 68
68
PM 68
68 68
68 68 68
68 68
68 68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
DINING
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TLT
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER CLOSET
9/1/2020 11:35 AM EnergyGauge® USA,6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software ' Page 7 of 8
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2
ft
0.3
BUTLER'S
Default(8 lbs/sq.ft.
ft2
ft
0.3,
PANTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL.
Default(8 lbs/sq.ft,
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2
ft
0.3
LIVING
Default(8lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft,
ft
0.3
OFFICE
Default(8 lbs/sq.ft.
ft2
ft
0.3,
ELEV
Default(81bs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
A/C
Default(8lbs/sq.ft.
ft2
ft
0.3
CABANA
Default(8lbs/sq.ft.
ft2 ,
ft
0.3
UTILITY
Default(8lbs/sq.ft.
ft2
ft
0.3
CLOSET
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8lbs/sq.ft.
ft2
ft
0.3
CLST. 3
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY.
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Room25
Default(8lbs/sq.ft,
ft2
ft
0.3
1 BALCONY
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH 5
Default(8 lbs/sq.ft.
ft2
ft
0.3
STUDIO
9/1/2020 11:35 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8
2017 -'AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LARSEN RESIDENCE Builder Name:
Street: SAEGER AVENUE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WAYNE LARSEN Jurisdiction: 6611000
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed,
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
.-.Yt,-.nri behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceillnoS.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/1/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
201TEPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 76
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
varies
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
78.6
a) Splif system SEER
varies
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 4989
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.648
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.282
14. Heating system: Capacity
51.0
c) Area
7c. 767.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. 0.320
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. 0.119
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b. 30.0
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1. 21.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 21.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a. 0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature::�z - Date: / Z-0-1-20
Address of New Home: SAEGER AVENUE City/FL Zip: FT. PIERCE, FL
9/1/2020 11:36:02 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1