Loading...
HomeMy WebLinkAboutTrussA=LIFE SAF TY WARNING This symbol identifies Life; fety Warnings that should be read given special attention by I persons installing trusses. It SPA iNG NOTE j ALL TRU5 3 5 ARE TO BE SET AT 2!,- ` ON CENTER EXG T AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGE HER PER ENGINEERIN BEFORE S TTING. REFER TO ENGINEERING AWING TO DETERMINE All IF M ILTIPLE PLY. A DON'TI L FT TRUSSES WITH SPAIS S LONGER THAN 30THE PEAK. ClN ULT BCSI 30' Span or less 30' to 60' Span 60 degr e Sprea er Bar or less of t /2 ___� li' cg F—Approx 2/3 tom TLine span cpprox. aria /z o+ span ag REFER TO BCSI REFER TO BCSI Truss .must. be set this way if crane used. Truss must be set this way if crane used. truss •s on e.ampie,. your truss may not match.:his is an example, truss may not match. Insist crane operator sets truss this way. Insist crone operator sets truss this way. All load bearI ig walls, headers, beams & lintibIls must be in place ' at indicated hght before trusses ® are, i stalled. AI R MAN 1_111Ill' NOTE UNLESS NOTED ELSEWF E ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FO Z kIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQU R MENTS. THIS MAY BE IN CONFLICT WITH BUILDING COD :AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDIN EPARTMENT AND A/C CONTRACTOR. U REPRE4 TS A HANGER Carying Girder For Truss to Tr� s Connections s hanger/connect r Naga must be as shown. Guide tabs Or schedule in engini lering Dome angle nails. v k package. F Carried Truss SEAT PLATE BY CHAMBERS INDICAT LOAD BEARING WALL REQUIR I BY TRUSSES SUPPLI 0 BY BUILDER AT A HE HT OF 8'-1" ABOVE I ISHED FLOOR ; I 12 .00 — I 81 et=1/4" heel=315/16" 41. LIMB CUT END 1, I 4 Top Chord I LL HEIGHT I ICAL END DETAIL j 12 Oo I to 8 1 2 2.00 Jp et=1/4" heel=315116" MB CUT END 4 Top Chord I i LL HEIGHT 8'-1" 11 D DETAIL: A i ® ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17' - 23' IN LvNGT ® Do not stand on trusses until they are braced per SCSI & properly nailed to straps & hangers 34 -- -- GARAGE LEFT O'-A" N �, -------------------------------:;------------------------------� y 10,000,offir ® �'010� ®_ 10 _■ �0101 ® cam y� l /, IPA■ e / - r r ■ ,..1I ,r ■■14 1 � /1-�III�'%I■I■■I■�I�■I■I■Ill I►� �� ®I■I�I�����I�I�I�I�I�I�I I�I�I®�� 9' 6" T-4" 5'4" 11.10" — 34' FABRICATION AGREEMENT TRU83ES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED d RETURNED The legal description of the property where the trusses will be Installad Is: The undersigned acknowledges and agrees: 1: Trusses will be made In strict eccoNence with this truss placement diagram layout, which Is the sole authority for detertnlningsueceseful fabrication of the trusses. 2.A11 dimenslans ""'his goatlayout have been verifled by the undersigned. fm day: olldelNeryhthe under"gn dvagreeayNet roe backcherrges with be lowed,.ln11 l the event such written notice ui Pomlahed Chambers Trues shall have three (3) bu ness days In a on to begin repairs required, or to subatituJe other Wssea, at Chambers optin. 4. The undersigned acknowledges receipt of "BCSI 1-03"summerysheet by'rial 8 WTCA. ug delivery.S. lChambersIs to Job site. Two$'far as the role aIs the uthod to determine o the 'a the lionsibility to ty of the Job site oy a portion of the Job site fordalivery. Chambers 7mss v4.. be responsible for dump delivit ery only. The buyer Is responsible for additional delivery expenses It Chambers Truss has to redeliver because job site is not prepared for delivery or buyer Is not prepared for delivery of trusses, Buyer is responsible to Chambers Trues for towing costs duo to site conditions. S. Price as shown Iq paragraph 7 below Is subject to change If any changes are, made In this.leyb�L A $50 per hour fee for revisions may be charged by Chambers Trues, . T This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed 11% or If In agreement a reasonable price. Invoice will be made on delivery and paid within terms of no " on delivery. Invoice may, ba made at Scheduled date of delivery If buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambera,Truss reasonable attomey's fee for collections In event of payment not timely made, 1-12 % per month s,Mce charge wig be added for all sums not paid within terns. S. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. 9, In consideration of Chambers Truss a dending credit for this materiel the underalgned - unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Trues by any entity receiving material and the undersigned agrees to pay such Indebtedness inducting etipmeys fees, It default In payment for material be made by the recipient. ' 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments retard to herein, the. parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsl6li les are per "National Standard And Rocbmtnended Guidelines On Rasponslblildes For Construction Using Metal Plate Connected Wood Trusses ANSI/TPIANTCA 4 - 2002 DATED SIGNED FOR TIRE Aspreader bar may bs required per"BC511-03" to pnaerH iryury 8 damago Multiple ply trusses must be fastened tog6th lr per onglnserlrtg before they are set, failure to do so can result In roof collapse. Temporary and permanent bracing are required and can save life and property and Is the resPOnslbllity of the truss erector. :Study the contents of the Information packet Included on delivery before setting trusses. Trusses must be aetand braced per design to prevent lnf ury& damiage, Trusses must be sat plumb and square Do not `set bunks or stack of plywood, roofing material or any other cothcentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING TVS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC 3106 Oleander Avenue Fort Plerce; Florida 34982-6423 800-551-5932 Fort Pierce 772465-2012 Fax 772-465.8711 VeroBeach 772569-20%b*ArehltOGWMRArTF2406 30Z.eentative's shop drawlnU aqtprovai Is, NOT'a' "doubha check" of the contractor. The contractor shall ramsm responsible for checking field measurements and other construction criteria: Architect's approval covers, general :roof shape, reviewof truss Sir Aping, and loading on structure from gran ty and uplift loads and thotr reap ati locations. Date: —roved 6y. 92.0/93.2 MITEK 4.2 Lraden 8 8r�de A..A. P.A. DESIGN CRITERIA County SAINT LUCIE Building Department SAINT LUCIE COUNTY z Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 3 I Roofing Material Shingle or Shake 01 -N Loading in PSF Roof R.D.L. 9) s Top Chord Live 20 Top Chord Dead 7 4.2 o c Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 c<1I 3 I TOTAL Load 37 7.2 ra o Duration Factor 1.25 a Wind Speed 165mph .LOCO e Top Chord C.B. Sheeting by builder. Pry Bottom Chord C.B. Sheeting by builder. 0 �Highest Mean Height 14'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the IN Building Desi ner and/or Engine I of Record. Chambers Truss Inc. Drawing Name: 10111323 UJ Scale: 1 /4 = 1' 72 total trusses, 13 different trusses. MI 4: SAE ACAD: SAE Reviewed By: Date: 04/24/12 Revised: 02/21/18 FOR Revised:3/05/2020 " WYNNE BUILDING CORP. DESCRIPTION: GARAGE RIGHT " CARLTON -7-7137 PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11323 FILE COPY l 12 �� MiTek' \n�Q�� RE: M11323 MiTek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T19884596 A 11/11/2020 2 T19884597 A5 11/11/2020 3 T19884598 A6 11/11/2020 4 T19884599 A7 11/11/2020 5 T19884600 A8 11/11/2020 6 T19884601 A9 11/11/2020 7 T19884602 GRA 11/11/2020 8 T19884603 GRB 11/11/2020 9 T19884604 J2 11/11/2020 10 T19884605 J4 11/11/2020 11 T19884606 J6 11/11/2020 12 T19884607 J8 11/11/2020 13 T19884608 KJ8 11/11/2020 This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copin The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision %%Vi"I based on the parameters provided by Chambers Truss. , Truss Design Engineer's Name: Velez, Joaquin � �..��G E NS�.,�'� My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSUTPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 0". STATE OF :�IJJ R � ONAL 111111 ,%% %%%`• Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 November 11, 2020 1 of 1 Velez, Joaquin Job Truss Truss Type • Qry Ply M11323 T79884596 M11323 A COMMON 9 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1 I D:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_l Hpv5SDpc_pEKrtnVLQuvtwTtLrJ WzUUjw 1-0-0 6-7-13 12-4-13 17 0 21-7-3 27-4-3 34-0-0 5-0- o 66 7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 -0-0 4.00 12 4x5 = 27 Scale = 1:57.8 17 '" 15 "" "' 14 12 3x6 = 2x3 II 46 = 3x8 = 3x8 = 4x6 2x3 II 3x6 = 6-7-13 5-9-0 9-2-7 5-9-0 6-7-13 Plate Offsets (X,Y)— [2:0-0-2,Edge], [10:0-0-2,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.32 14-15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.61 14-15 >670 240 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) 0.12 10 n/a n/a BCDL 10.0 Code FBC2017rTP12014 Matrix -MS Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10), 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3419/2395, 3-5=-2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031, 9-10=-3419/2395 BOT CHORD 2-17=-2132/3213, 15-17=-2132/3213, 14-15=-1269/2000, 12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-4-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members, with BCDL = 10.Opsf. electronically signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) sealed by Velez, Joaquin, PE 2=832, 10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility Printed copies of this of others. document are not Considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads Joaquin Velez PE No.68182 =- Vert: 1-6=-54, 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cert 6634 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I19/2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall I ITS! building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing A!Tek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss ype M11323 ]SPECIAL T19884597 M11323 A5 �Qty 9 �Ply 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv �1-0-0 7-8-5 1%.-4 17-0-0 2018 26-4-0 34-0-0 -0-0 7-8-5 2-9-15 6-5-12 3 4-8 5-11-8 7-8-0 -0-0 5x8 MT18HS 11 4.00 12 Scale=1:59.8 13 12 5x12 = 2x3 II 3x6 = 3x12 = 2.00 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TIC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 BC 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 WB 0.60 Horz(CT) 0.36 10 n/a n/a Matrix -MS Weight: 155 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 1 Row at midpt 6-14 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813, 9-1 0=-3195/221 0 BOT CHORD 2-14=-3466/5266, 13-14=-130512115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277, 9-1 3=-786/560, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vu1t=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 2=803, 10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall p r iT®k• building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iw fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply 1111323 T19884598 M11323 A6 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 I D:2GIScwwyY5hnGhXVARzUkuyuFUM-YYr6a4B_WeYX90cbwODHJlx7ilyPMm6DxBgy00zUUju 1-0 0 8-11-11 16-0-0 18-0-0 20�-8 25-11-15 34-0-0 15-01 1-0 8-11-11 7-0-5 2-M 2-4-8 5-7-7 8-0-1 1-0-0 4.00 12 3x12 = 2.00 12 LOADING (psi) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017[TP12014 LUMBER - TOP CHORD 2x4 SP M 30 *Except* 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 `Except' 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) 6x10 MT18HS = 5x6 = 5x6 = 2x3 II 1.0 20-4-8 25-11-15 3x6 = Scale=1:61.9 CSI. DEFL. in (loc) I/defl Ltd PLATES GRIP TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 BC 0.93 Vert(CT)-0.9214-17 >443 240 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 9 n/a n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 cc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=5095/3071, 5-6=-2314/1551, 6-8=-2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=-1731/3001, 9-11=-1731/3001 WEBS 4-14=-492/513, 5-14=-170712959, 5-13=-405/196, 6-13=-179/522, 8-12=-893/660, 8-11=01303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 24-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803,9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Sal' l• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦ is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884599 M11323 A7 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID:WSJgpGwal Ppeur6hk9UjG5yuFUL-OIPUnQCcHygOmYBnUkXWryTIFil45CW 9gaVwrzUUjt i1-0-0, 8-10-10 14-0-0 20-0-0 25-11-15 34-0-0 35-0-Q h-0-0' 8-10-10 5-1-6 6-0-0 5-11-15 8-0-1 -0-0 Scale = 1:60.8 5x8 = Sx6 = Ann 5x12 = 2x3 I 3x6 = 3x12 = 2.00 12 10-64 14-0-0 20-4-8 2%11-15 34-0-0 10-6-4 3 5 12 6-4-8 5-7-7 8-0-1 Plate Offsets (X,Y)— [2:0-1-15,Edge), [4:0-4-0,0-2-3), [7:0-0-2,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.10 10-11 >369 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.34 7 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 147 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Horz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) FORCES. (lb) -Max. Comp.lMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=-2229/1544, 5-6=-2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=-3071/5219,10-11=-1590/2874,9-10=-1738/2968,7-9=-1738/2968 WEBS 3-11=4191443, 4-11 =-1 466/2647, 4-10=-812/448, 5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 24-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This item has been 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) Printed copies of this 2=803, 7=803. p document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the buildingdesigner must verify the applicability of design parameters and property Incorporate this design Into the overall p p� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IVIiT®k• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB•89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply T19884600 M11323 A8 SPECIAL 1 1 �1011323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 I D: WSJ q pGwal Ppeur6hk9UjG5yuFU L-Uxzs_mC E2FoFOiI_2R210AOTj6e Kqi E WOUJ2SHzUUjs 1-0.0 8-84 12-0-0 15 8 4 20-4-8 22-M 24-8-12 34-0-0 5-0 -0-0 8-8-4 3-3-12 3-8-4 4-8-0 1-7-8 2-8-12 9-3-4 1-0-0 �1 6 3x12 4.00 12 2.00 12 5x6 = 3x4 = 4 21 5 20.4-8 2x3 11 5x8 = 6 22 7 12 11 5x12 = 3x4 = 4x5 = Scale = 1:60.6 ' 10-6-4 9-10-4 1-7-8 12-M Plate Offsets (X,Y)— [2:0-1-15,Edge), [7:0-5-8,0-2-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.65 12-13 >624 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.08 12-13 >379 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.69 Horz(CT) 0.33 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 154 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5-6=-2576/1770, 6-7=-2586/1779, 7-8=-2663/1762, 8-9=-3021/1971 BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11=-1705/2827 WEBS 3-13=396/420,4-13=-1028/1721, 5-13=-300/797,5-12=-894/601,6-12=-265/263, 7-12=-294/391, 7-11=-374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803,9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall p� iTe k• building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iVl fabrication, storage, delivery,erection and bracing of trusses and truss systems, see ANSIITPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 �Qty T19884601 M11323 A9 HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1 to: _etC 1 cxC3ixVV?huts?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZ18W4CZ7Mfd83c?jzUUjr 1-0-0 6-7-15 10-0-0 15-2-14 20.4-0 24-0-0 27-4-1 34-0-0 5-0- -0-0 6-7-15 3 4-1 5 2-14 5-1-2 3-8-0 3-4-1 6-7-15 -0-0 4.00 12 4x4 = 3x4 2x3 II 4x8 = = 4 24 525 26 6 27 7 Scale = 1:58.6 15 14 13 12 11 3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5 24-0-0 34-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017lrPI2014 CSI. TC 0.35 BC 0.54 WB 0.89 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/deft Ud -0.18 11-21 >917 360 -0.38 11-21 >432 240 0.02 13 n/a n/a PLATES GRIP MT20 244/190 Weight: 156 lb FT = 0% LUMBER. BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=-249(LC 10), 13=928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1275/1025, 3-4=-913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-5651807, 7-8=104/278, 8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=-124/304 WEBS 3-15=-425/501, 5-15=-444/665,5-13=1215/1079,6-13=-264/300, 7-11=-255/396, 8-11=461/521, 7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Extedor(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically signed and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) sealed by Velez, Joaquin, PE 2=430, 9=249,13=928. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not my a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety lnformatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply T19884602 M11323 GRA HIP 1 1 �M`11323 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 8-0-0 13-1-1 5-10-15 1-6-0 3-8-2 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = 11 14 Scale = 1:60.6 3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSI/TPI 1. 8-0-0 11-1-1 18-6-0 26-0-0 34-0-0 8-0-0 3-1-1 7-4-15 7-6-0 8-0-0 Plate Offsets (X,Y)— [2:0-2-2,Edge], [3:0-3-8,Edge], [21:0-3-8,Edge], [24:0-3-8,0-3-0], [27:0-3-8,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 TCDL 7.0 Lumber DOL 1.25 BC 0.57 BCLL 0.0 Rep Stress Incr NO WB 0.98 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) 0.20 24-35 >914 360 MT20 244/190 Vert(CT) -0.24 29-32 >552 240 Horz(CT) 0.02 22 n/a rile Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8), 22=-625(LC 8) Max Grav All reactions 250 Ito or less at joints) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14), 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280,20-21=-2230/1280,21-22=-2271/1263,6-9=-126/305,9-11=-106/363, 11-14=-1931412, 14-17=-94/271, 19-21 =-1 43/272 BOT CHORD 2-29=-247/677, 27-29=-189/540, 26-27=-779/446, 24-26=-411/653, 22-24=-1083/2108 WEBS 3-29=-500/1176, 3-27=-17661911, 5-27=-748/622, 5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=-608/514, 19-20=-335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. This item has been 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. . Printed copies of this 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. document are not considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift atjoint 2, 1168 lb uplift at signed and sealed and the joint 27, 1495 lb uplift atjoint 26 and 625 lb uplift atjoint 22. signature must be verified 8) Girder carries hip end with 8-0-0 end setback. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. On any electronic Copies. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the 6904 Parke East Blvd. Tampa FL 33810 responsibility of others. Date: 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). April 3,2020 andard ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall my building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17rP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety /nformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 ID:_etCt cxC3ixVVlhulslypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=-47(F=-27),24-33=-20, 3-11=-126(F=-72), 11-21 =-1 26(F=-72) Concentrated Loads (lb) Vert: 29=-641(F) 24=-641(F) WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITE( REFERENCE PAGE MII-7473 rev. 5I19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall A� building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IyliTe k• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 ID:SrRaEyyrgO4M78G4raWBLWyuFUJ-u We7doF7LAApF9UZjacSOce_iJjP10by4SYi3czUUjp 1-0-0 8-0-0 13.8-0 17-0-0 20-0-0 26-0-0 34-0-0 5-0- -0-0 8-0-0 '8 0 3 4-0 3-0-0 5-8-0 8-0-0 -0-0 Scale=1:58.6 5x12 MT18HS = 4.00 12 4x10 = 2x3 I I 4x6 = 23 4 5 6 2x3 II 7 24 5x12 MT18HS = 16 15 14 13 12 11 4x6 — 3x6 II 5x6 = 6x12 = 6x12 = 5x6 — 3x6 II 4x6 8-0-0 13-8-0 go 40 26-0-0 34-0-0 8-0-0 5-8-0 6-8-0 5-8-0 8-0-0 LOADING (psf) SPACING- 2-M CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) 0.22 16-19 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.30 16-19 >820 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr NO WB 0.90 Horz(CT) 0.06 9 n/a n/a BCDL 10.0 Code FBC2017lrP12014 Matrix -MS Weight: 153 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-14, 8-13, 6-13 4-14,7-13: 2x6 SP No.2 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Horz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589, 8-9=-751 /370 BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668 WEBS 3-16=435/1209, 3-14=1552/774, 4-14=-837/691, 7-13=-878/713, 8-13=-3635/1919, 8-11=-432/1204,6-14=-1453/2814,6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at joint 13 and 345 lb uplift at joint 9. 8) Girder carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=49(F=-29), 11-20=-20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.66182 MiTek USA, Inc, FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall let building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPN Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641 (F) 11=-641(F) 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 I D:S rRa EyyrgO4M78G4ra W B LW yu FU J-M iCN g7G16U IgtJ31H H7hYOB9Sj3emSr6J6H Gb2zUUjo ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall �• building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323T19884604 �ty M11323 J2 MONO TRUSS 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:xl?zSIzTbJCDI IrGPH 1 QukyuFUI-MiCNg7Gl6UIgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo -1-0-0 2-0-0 1-0-0 2-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.07 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC20171TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10), 4=-3(LC 7) Max Grav 3=39(LC 15). 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:7.8 2-0-0 DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) -0.00 7 >999 360 MT20 2441190 Vert(CT) -0.00 7 >999 240 Horz(CT) -0.00 3 n/a n/a Weight: 8 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 i ®WARNING -Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I1912020 BEFORE USE. �— Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSBTPN Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type __] Ply M11323 T19884605 M11323 J4 �Qty MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz7ZfRxyuFUH-gvml2TGNtoQXUTexRewSDJQW7UmV7DFYml p8UzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 Scale=1:11.1 3x4 = ' 4-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) .I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 rile n1a BCDL 10.0 Code FBC2017lrP12014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall�- building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criterfa, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety lnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 T19884606 M11323 J6 MONO TRUSS �Qty 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:tP6jtzJ7xSx_c fXi4uz9yuFUG-gvmi2TGNtoQXUTexRew5DjR77MUV7DFYm1p8UzUUjn 1-0-0 6-0-0 1-0-0 6-0-0 Scale = 1:14.6 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10), 2=-194(LC 10), 4=-8(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property, damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUlP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type I City Ply �IV111123 T19884607 M11323 J8 MONO TRUSS 20 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 ID:tP6jtzLj7xSx_c fXi4uz9yuFUGJ5K7FpH7d5YO6dD80199eRGYgXquEaTPmQmNgxzUUjm 1-0-0 8-0-0 1-0-0 8-0-0 Scale=1:17.4 3x5 = 8-0-0 8-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WE 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=-15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 260 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterior(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. k® Design valid for use only with MiTeconnectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSBTPH Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type , city Ply M11323 T19884608 M11323 KJ8 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 I D:Lcg54J? Lu EancmZr4Qb7 W MyuFU F-nH uVT9ld OPgFknoKyPgOAeooawBGzwZY?4 WwCNzUUjI i -1-5-0 7-3-411-3-0 1-5-0 7-34 3-11-12 Scale = 1:20.3 3x4 = 5 3x4 = 7-34 11-3-0 7-34 3-11-12 LOADING (psg SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=-305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=-687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=-1236/755 PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE Vert: 1-2s 54 Trapezoidal Loads (pig using a Digital Signature. Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, 6=-49), 8=0(F=10, B=1 0)-to-5=-56(F=-1 8, 6=-18) copies of this Prp tco ine document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall r building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIflPH Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION 3/; Center plate on joint unless x, y offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See BCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For 1/ Ole fi r c1.2 c2-3 wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I WEBS Ac4 Q of o �'•0 3 �� 903. p bracing should be considered. Never exceed the design loading shown and never stack materials on inadequately braced trusses. iL U 4. Provide copies of this truss design to the building 11designer, O0 erection supervisor, property owner and For 4 x 2 orientation, locate c7-a c6-a 1-- all other interested parties. plates 0- yid from outside P BOTTOM CHORDS 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBEREWLETTERED CLOCKWISE locations are regulated by ANSI/TPI 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7, Design assumes trusses will be suitably protected from connector plates. THE LEFT. the environment in accord with ANSI/TPI 1. `Plate location details available In MITek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. 9. Unless expressly noted, this design is not applicable for PLATE SIZE PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. ICC-ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions the length parallel to slots. indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise shown. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. section 6.3 These truss designs rely on lumber values BEARING established by others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports) occur. Icons vary but reaction section indicates joint © 2012 MITek® All Rights Reserved 17. Install and load vertically unless indicated otherwise. ��� number where bearings occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards: 19. Review all portions of this design (front, back, words ANSI(rP11: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. . DSB-89: Design Standard for Bracing. � 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSIITPI 1 Quality criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MITek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 or other loads other than those expressly stated.