HomeMy WebLinkAboutEnergy CodeFORM R405-2017
. � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential. Performance Method
ProjectName: WYNNE THE W INDSOR I ACT
BuilderName: WYNNE DEVELOPMENT
Street: �� �� �� C
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, J
PermitNumber:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New ,(From Plans)
9..WallTypes (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame- Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floorarea above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorarea belowgrade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7.. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 111.36 ftz
SHGCi SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency .
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15..Credits
Pstat
Total Proposed Modified Loads: 52.17
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.92
I hereby certify that the plans and specifications covered by
Review of the plans and'Itr,�
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
1y,�' =►
with the Florida Energy Code.
PREPARED 13Y; _ - -
Before construction is completed
r '
DATE:
this building will be inspected for
- :�•
_
compliance with Section 553.908
*•
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
With the Florida Energy Code.
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler Unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance With R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater. than 5.00 ACH50 (R402.4.1.2).
4/21/202010:04 AM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
• FORM R405-2017 INPUT SUMMARY CHECKLIST REP.ART
PROJECT
Title: WYNNE THE WIN DSO R IMP Bedrooms: 3
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
PermitOffice: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:.
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family.
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
V DesignLocation
TMY Site 97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfIID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No .
Yes
Yes
6 BEDROOM 2
180 1440 No
0'
1
1
Yes
Yes '
Yes
7 DINING/GREAT RO
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO 37 ft 0
224 ft2
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0' 1
0
3 Slab -On -Grade Edge Insulation
MASTER BATH 8 ft 0
56 ft2
____
0 1
0
4Slab-On-Grade Edge Insulation
M. BATH 7ft 0
61 ft2
____
0 1
0
5Slab-On-Grade Edge Insulation
LAUDRY 1 ft 0
36ft2
____
0 1
0
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST RFanRT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
6Slab-On-Grade Edge Insulation
BEDROOM 2 12 ft
0
180 ft2
____
0 1
0
7Slab-On-Grade Edge Insulation
DINING/GREAT 50ft
0
588ft2
____
0 1
0
8Slab-On-Grade Edge Insulation
KITCHEN lift
0
209ft2
____
0 1
0
9 Slab -On -Grade Edge Insulation
BATH 5 ft
0
50 ft2
____
0 1
0
10SIab-On-Grade Edge lnsulation
HALL 1 ft
0
25ft2
____
0 1
0
11SIab-On-Grade Edge Insulation
FOYER 9 ft
0
92 ft2
____
0 1
0
12SIab-On-Grade Edge Insulation
BEDROOM 3 14 ft
0
169 ft2
____
0 1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul. (deg)
1 Hip Metal 1847 ft2
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# CeilingType
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented)
MASTER BEDRO
30
Blown
224ft2
0.1
Wood
2 UnderAttic(Vented)
WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic(Vented)
MASTER BATH
30
Blown
56ft2
0.1
Wood
4 UnderAttic(Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 UnderAttic (Vented)
LAUDRY
30
Blown
36ft2
0.1
Wood
6 UnderAttic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic
DINING/GREAT
30
Blown
588ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 UnderAttic (Vented)
BATH
30
Blown
50ft2
0.1
Wood
10 UnderAttic (Vented)
HALL
30
Blown
25 ft2
01
Wood
11 UnderAttic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 UnderAttic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
.Wood
WALLS
Adjacent
Cavity Width
Space
Height
Sheathing' Framing Solar
Below
0
1
E Exterior Concrete Block- Int InsuMASTER BE 4.1 16
0 8
0
128.0 ft2
0 0
0.3
0
2
W Exterior Concrete Block- Int InsuMASTER BE 4.1
7
0 8
0
56.0 ft2
0 0
0.3
0
3
S Exterior Concrete Block- Int InsuMASTER BE 4.1
14
0 8
0
112.0 ft2
0 0
0.3
0
4121 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017: FBC 6th Edition (2017) Compliant Software Page 3 of 6
^FORM R405-2017 INPUT RI IMMARY rNFrtCI I_CT 17POnOT
WALLS
Adjacent Space
Cavity Width
-
Height
Sheathing Framing
Solar Below
o
4
E
Exterior
Concrete Block - Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block- Int Insul M. BATH
4.1 7
0
8 0
56.0 1`1:2
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
7
S
Exterior
Concrete Block - Int InsuDINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 20
0
8 0
160.0 W
0
0
0.3
0
9
W
Exterior
Concrete Block- Int Insul KITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
_ 10
E
Exterior
Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Omt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed
to Worst Case.
/
Wall
Overhang
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
S 3
Metal Low-ESingle Yes
1.04 0.29
N
32A ft2
1 ft 0 in
1. ft 5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low-ESingle Yes
1.04 0.29
N.
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R45-2017 INPUT SUMMARY CHECKLIST REPORT,
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unitt
Split
Single SEER: 15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# . System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 50gal 60.9gal
120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
/ --Supply--
--- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 175 ft-
Attic
55 ftz DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Heating Jan Feb
Mar
f Apr f
Jul
May Jun njul
Aug
M
n Sep
L
H
Venting Jan Feb
Mar
[X] [
Jun
Aug
Sep
lx� Oc Nov
Dec!
ThermostatSchedule: HERS 2006
Reference
Hours
ScheduleType
1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM
78
78 78
78 78 78
78
78
80 80 80.
80
PM
80
80 78
78 78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78 78 78
78
PM
78
78 78
78 78 78
78
78
78 78 78
78
Heating(WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 66
66
Heating(WEH) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
.68
68 68 66
.66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(B.Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
it
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2 '
Default(8lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT RO
Default(8lbs/sq.ft.
ft2
ft
0.3
. KITCHEN
4/21 /202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software ' Page 5 of 6
FORM R465-2017
INPUT SUMMARY_ CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2 ft 0.3
BATH
D efault(8 lbs/sq.ft.
ft2 ft 0.3
HALL
Default(81bs/sq.ft.
ft2 ft 0.3
FOYER
Default 8lbs/s .ft.
ft2 ft 0.3 .
BEDROOM.3
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402A.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
to
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A. continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs.or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top. plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls.shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the, air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including _
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to theavailable cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall,
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in, exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind p'pwna and wereno-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls. adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers. and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots -that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in.a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be.used to fill voids
between fire snrinkler cover dates and walls or ceolinos.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/21/2020 10:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) = FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY.CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts . R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
1U
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab-on=grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with.tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:.
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type, and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy .Conservation, through the above energy
saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL
display card will be completed based -on installed code compliant features.
Builder Signature: Date: l
Addresstof New Home City/FL Zip: FT: PIERCE, FL
4/21/202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev: 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1