Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engery Calc
File Copy, FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TACOMA_eMED_MDW 91 Builder Name: GHO Homes Street: 2801 Bent Pine Dr. Permit Office: City,State,Zip: Fort Pierce,FL,34951 Permit Number: Owner: GHO Homes Jurisdiction: Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2265.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1971.70 ftz b.Frame-Steel,Adjacent R=11.0 294.00 ftZ 3. Number of units,if multiple family 1 c. N/A R= ft' 4'Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (2727.9 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2523.00 ftZ 6- Conditioned floor area above grade(ft') 2523 b.Knee Wall(Vented) R=19.0 204.92 ft' Conditioned floor area below grade(ft') 0 c. R= ft 11.Duct s R ft' 7. Windows(444.6 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Main 6 504.2 a. U-Factor: Dbl,U=0.49 248.00 ft' SHGC: SHGC=0.24 b. U-Factor: Dbl,U=0.53 96.00 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 60.0 SEER:16.00 c. U-Factor: Dbl,U=0.46 78.67 ft' SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 21.92 ft' a.Electric Strip Heat 60.0 COP:1.00 SHGC: other(see details) Area Weighted Average Overhang Depth: 8.011 ft. Area Weighted Average SHGC: 0.243 14.Hot water systems 8. Floor Types (2523.0 sqft.) Insulation Area a.Natural Gas Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 2523.00 ft' b. Conservation features EF:0.600 b.N/A R= ft2 None c. N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.176 Total Proposed Modified Loads: 78.63 PASS Total Baseline Loads: 81.12 1 hereby certify that the plans and specifications co red by Review of the plans and 04114E STgTF this calculation are in compliance with the Flori nergy specifications covered by this V e = , p� Code. calculation indicates compliance with the Florida Energy Code. ti rrre, ::': :•• „�� PREPARED BY: Before construction is completed Cc DATE: 7! /2 17 V this building will be inspected for compliance with Section 553.908 , • Ph ereby certify that t ' it as ned, is in compliance Florida Statutes. the Florida Energy Co e. OpWE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 L FORM R405-2014 PROJECT Title: TACOMA_eMED_MDW 91 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2523 Lot# Owner: GHO Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: GHO Homes Rotate Angle: 270 Street: 2801 Bent Pine Dr. Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City,State,Zip: Fort Pierce, Family Type: Single-family FL, 34951 New/Existing: New(From Plans) Comment: CLIMATE • IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO BEACH MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2523 23548.2 SPACES Number _ Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2523 23548.2 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 242.75 ft 0 2523 ft' ____ 0.6 0 0.4 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2822 ft' 0 ftz Medium 0.75 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 2523 ft' N N CEILING # Ceiling Type Space R-Value_ Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2523 ft' 0.11 Wood 2 Knee Wall(Vented) Main 19 Batt 204.92 ftZ 0.11 Wood 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type _ 1 S=>E Exterior Concrete Block-Int Insul Main 4.1 13 6 9 4 126.0 ft2 0 0.600000 0 2 SE=>NE Exterior Concrete Block-Int Insul Main 4.1 3 9 4 28.0 ft2 0 0.600000 0 _ 3 E=>N Exterior Concrete Block-Int Insul Main 4.1 2 6 9 4 23.3 ft2 0 0.600000 0 4 S=>E Exterior Concrete Block-Int Insul Main 4.1 7 9 9 4 72.3 ft2 0 0.600000 0 5 W=>S Exterior Concrete Block-Int Insul Main 4.1 10 9 4 7.8 ft2 0 0.600000 0 6 SW=>SE Exterior Concrete Block-Int Insul Main 4.1 3 9 4 28.0 ft2 0 0.600000 0 7 S=>E Exterior Concrete Block-Int Insul Main 4.1 9 11 9 4 92.6 ft2 0 0.600000 0 8 S=>E Garage Frame-Steel Main 11 24 4 9 4 227.1 ft2 0.23 0.01 0 9 E=>N Garage Frame-Steel Main 11 7 2 9 4 66.9 ft2 0.23 0.01 0 10 E=>N Exterior Concrete Block-Int Insul Main 4.1 39 8 9 4 370.2 ft2 0 0.600000 0 11 N=>W Exterior Concrete Block-Int Insul Main 4.1 27 9 4 252.0 ft2 0 0.600000 0 12 W=>S Exterior Concrete Block-Int Insul Main 4.1 7 7 9 4 70.8 ft2 0 0.600000 0 13 NW=>S Exterior Concrete Block-Int Insul Main 4.1 1 5 9 4 13.2 ft2 0 0.600000 0 14 N=>W Exterior Concrete Block-Int Insul Main 4.1 13 3 9 4 123.7 ft2 0 0.600000 0 15 E=>N Exterior Concrete Block-Int Insul Main 4.1 12 0 9 4 112.0 ft2 0 0.600000 0 16 N=>W Exterior Concrete Block-Int Insul Main 4.1 16 9 4 149.3 ft2 0 0.600000 0 17 W=>S Exterior Concrete Block-Int Insul Main 4.1 51 6 9 4 480.7 ft2 0 0.600000 0 18 NW=>S Exterior Concrete Block-Int Insul Main 4.1 2 4 9 4 21.8 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated Main None .14 3 8 24 ft2 2 S=>E Wood Main None .14 2 8 8 21.3 ft2 3 N=>W Insulated Main None .14 1 2 8 9.3 ft2 4 E=>N Insulated Main None .14 1 2.9 8 10 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>E 1 Metal Low-E Double Yes 0.49 0.24 36.0 ft2 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 2 SE=>NE 2 Metal Low-E Double Yes 0.49 0.24 12.0 ft2 7 ft 11 in 7 ft 11 in Drapes/blinds Exterior 5 3 S=>E 4 Metal Low-E Double Yes 0.46 0.26 8.0 ft2 8 ft 6 in 6 ft 9 in Drapes/blinds Exterior 5 4 S=>E 4 Metal Low-E Double Yes 0.46 0.26 9.7 ft2 8 ft 6 in 4 ft 1 in Drapes/blinds Exterior 5 5 SW=>SE 6 Metal Low-E Double Yes 0.49 0.24 12.0 ft2 9 ft 4 in 7 ft 11 in Drapes/blinds Exterior 5 6 SW=>SE 6 Metal Low-E Double Yes 0.46 0.26 3.8 ft2 9 ft 4 in 5 ft 7 in Drapes/blinds Exterior 5 I: 7 S=>E 7 Metal Low-E Double Yes 0.49 0.24 30.0 ft2 2 ft 0 in 3 ft 5 in Drapes/blinds Exterior 5 8 S=>E 7 Metal Low-E Double Yes 0.46 0.26 12.0 ft2 2 ft 0 in 1 ft 8 in Drapes/blinds Exterior 5 9 E=>N 10 Metal Low-E Double Yes 0.49 0.24 12.0 ft2 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 10 E=>N 10 Metal Low-E Double Yes 0.49 0.24 40.0 ft2 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 11 N=>W 11 Metal Low-E Double Yes 0.25 0.18 10.7 ft2 5 ft 4 in 3 ft 4 in Drapes/blinds Exterior 5 12 N=>W 11 Metal Low-E Double Yes 0.49 0.24 36.0 ft2 5 ft 4 in 3 ft 1 in Drapes/blinds Exterior 5 13 N=>W 11 Metal Low-E Double Yes 0.46 0.26 8.0 ft2 5 ft 4 in Oft 11 in Drapes/blinds Exterior 5 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 de rees . / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 W=>S 12 Metal Low-E Double Yes 0.49 0.24 24.0 ft' 17 ft 0 in 3 ft 7 in Drapes/blinds Exterior 5 15 W=>S 12 Metal Low-E Double Yes 0.46 0.26 5.3 ft' 17 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 16 N=>W 14 Metal Low-E Double Yes 0.53 0.25 96.0 ft' 14 ft 4 in 3 ft 1 in Drapes/blinds Exterior 5 17 N=>W 14 Metal Low-E Double Yes 0.46 0.26 16.0 ft' 14 ft 4 in Oft 11 in Drapes/blinds Exterior 5 18 E=>N 15 Metal Low-E Double Yes 0.25 0.18 11.2 ft' 32 ft 8 in 3 ft 4 in Drapes/blinds Exterior 5 19 N=>W 16 Metal Low-E Double Yes 0.49 0.24 40.0 ft' 2 ft 0 in 1 ft 1 in Drapes/blinds Exterior 5 20 W=>S 17 Metal Low-E Double Yes 0.49 0.24 6.0 ft' 2 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 21 W=>S 17 Metal Low-E Double Yes 0.46 0.26 12.0 ft' 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 22 SE=>NE 2 Metal Low-E Double Yes 0.46 0.26 3.8 ft' 7 ft 11 in 5 ft 7 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 688.988895 ft' 688.988895 ft' 77.5 ft 9.33 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000415 2747.3 150.82 283.64 .303 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 60 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 60 kBtu/hr 1800 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas None Garage 0.6 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 504.2 ft Attic 126.05 Proposed Qn Main ---cfm 151.4 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma rj Jun Jul rj Au Se ]Oct Nov Dec Heatin HJan HFeb Mar APr MaY Jun IXI Jul Au �Xj Sep ]Oct H Nov HDec Ventin Jan Feb X Mar [X]A r [ Ma Jun Jul Aug Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 i f 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 2801 Bent Pine Dr., Fort Pierce, FL, 34951 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1971.70 ft2 b. Frame-Steel,Adjacent R=11.0 294.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 2523.00 ft2 6. Conditioned floor area(ft2) 2523 b. Knee Wall(Vented) R=19.0 204.92 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl,U=0.49 248.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.24 a.Sup:Attic,Ret:Attic,AH: Main 6 504.2 b. U-Factor: Dbl,U=0.53 96.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.46 78.67 ft2 a.Central Unit 60.0 SEER:16.00 SHGC: SHGC=0.26 d. U-Factor: other(see details) 21.92 ft2 13.Heating systems kBtu/hr Efficiency SHGC: other(see details) a.Electric Strip Heat 60.0 COP:1.00 Area Weighted Average Overhang Depth: 8.011 ft. Area Weighted Average SHGC: 0.243 8. Floor Types Insulation Area 14.Hot water systems a.Natural Gas Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 2523.00 ft2EF:0.6 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building qHE S7 Construction through the above en rgy saving features which will be installed (or exceeded) gpFo in this home before final inspectio Otherwise, a new EPL Display Card will be completed based on installed Code complia features. ,,,,� --: :;: r• ;;;: x Builder Signature: Date: Address of New Home: Z Q City/FL Zip: E, - p/Le rt, g'S 3 ySSI CDUW-Eto 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/6/2017 9:00 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Analysis Job: Tacoma Lot-91 g J Date: 7-5-17 Entire House By: Skyetec Project • • For: GHO Homes 2801 Bent Pine Dr., Fort Pierce, FL 34951 Design C• • • Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 29 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.4 56.9 Dry bulb(T) 41 90 Infiltration: Daily range (T) - 15 ( L ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 4.1 7739 18.1 Glazing 14.4 6095 14.3 Doors 11.3 1018 2.4 Ceilings 0.9 2278 5.3 Floors 2.9 7238 16.9 Infiltration 2.0 4282 10.0 Ducts 10471 24.5 Piping 0 0 _ Humidification 0 0 Ventilation 3646 8.5 Adjustments 0 Total 42767 100.0 Component Btuh/ft2 Btuh % of load Walls 2.5 4774 11.6 .� Glazing 22.6 9601 23.3 . .. Doors 11.4 1028 2.5 Ceilings 1.0 2577 6.2 Floors 0 0 0 t Infiltration 0.5 1137 2.8 Ducts 12756 30.9 Ventilation 1936 4.7 Internal gains 7470 18.1 Blower 0 0 Adjustments 0 a. Total 41280 100.0 Latent Cooling Load= 12655 Btuh Overall U-value= 0.115 Btuh/ft2-°F Data entries checked. + wrightsoft' 2017-Jul-17 16:56:08 14CCA Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 ...oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E Coal onent Constructions Job: Tacoma Lot-91 p Date: 7-5-17 Entire House By: Skyetec Project • • For: GHO Homes 2801 Bent Pine Dr., Fort Pierce, FL 34951 Design C• • • Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (T) 29 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 24.4 56.9 Dry bulb(T) 41 90 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/W-T ft'-°F/Btuh Btuh/W Btuh Btuh/ft' Btuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk, 1/2"gypsum n 421 0.143 4.0 4.15 1745 2.59 1089 board int fnsh ne 13 0.143 4.0 4.15 55 2.59 34 e 208 0.143 4.0 4.15 864 2.59 539 se 19 0.143 4.0 4.15 78 2.59 49 s 549 0.143 4.0 4.15 2278 2.59 1422 sw 21 0.143 4.0 4.15 85 2.59 53 w 369 0.143 4.0 4.15 1530 2.59 955 nw 32 0.143 4.0 4.15 134 2.59 83 all 1632 0.143 4.0 4.15 6768 2.59 4224 Partitions 12B-Osm:Frm wall,stucco ext,r-11 cav ins, 1/2"gypsum board int 264 0.122 11.0 3.54 934 2.01 531 fnsh,2"x4"metal frm, 16"o.c.stud 12C-Osw:Frm wall,stucco ext,r-13 cav ins,2"x4"wood frm,16"o.c. 14 0.091 13.0 2.64 37 1.31 18 stud Windows 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 3 0.490 0 14.2 39 10.2 28 thk:2 glazing,Or low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, n 12 0.490 0 14.2 171 10.2 123 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45',medium;50% s 6 0.490 0 14.2 89 10.2 64 outdoor insect screen; 1.5 ft overhang(3 ft window ht, 1 ft sep.);6.67 ft w 3 0.490 0 14.2 39 23.7 65 head ht all 24 0.490 0 14.2 337 11.8 280 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" n 40 0.490 0 14.2 568 10.2 409 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, ne 10 0.490 0 14.2 136 19.4 186 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45',medium;50% a 20 0.490 0 14.2 278 24.2 473 outdoor insect screen; 1.5 ft overhang(5 ft window ht, 1 ft sep.);6.67 ft e 20 0.490 0 14.2 284 24.2 483 head ht w 40 0.490 0 14.2 568 24.2 967 all 129 0.490 0 14.2 1835 19.5 2518 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4" ne 4 0.490 0 14.2 54 19.4 74 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45",medium;50% e 6 0.490 0 14.2 85 23.1 139 outdoor insect screen; 1.5 ft overhang(2 ft window ht, 1 ft sep.);6.67 ft head ht s 12 0.490 0 14.2 171 10.2 123 all 22 0.490 0 14.2 310 15.4 336 wri htsoft 2017Jul-1716:56:08 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 ...oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" e 6 0.460 0 13.3 80 24.0 144 thk:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50% outdoor insect screen; 1.5 ft overhang(2 ft window ht, 1 ft sep.);6.67 ft se 4 0.460 0 13.3 51 13.0 50 head ht all 10 0.460 0 13.3 131 19.7 194 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4" e 15 0.460 0 13.3 200 26.0 390 thk:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45",medium;50% outdoor insect screen; 1.5 ft overhang(5 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap,1/4" e 8 0.490 0 14.2 114 10.2 82 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen; 10 ft overhang(2 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap, 1/4" e 15 0.490 0 14.2 207 24.9 363 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45•,medium;50% _outdoor insect screen; 1.5 ft overhang(5 ft window ht,3 ft sep.);6.67 ft se 10 0.490 0 14.2 136 19.7 189 head ht all 24 0.490 0 14.2 343 22.8 552 2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4" e 8 0.490 0 14.2 114 18.8 151 thk:2 glazing,cir low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45•,medium;50% outdoor insect screen; 10 ft overhang(8 ft window ht,5 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap,1/4" s 5 0.490 0 14.2 68 10.2 49 thk:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen;7.5 ft overhang(1.6 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" s 18 0.490 0 14.2 256 10.2 184 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% outdoor insect screen;7.5 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr,1/4"gap, 1/4" w 10 0.460 0 13.3 128 10.1 97 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50% outdoor insect screen;6 ft overhang(1.6 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air has,vnl frm met,clr innr,1/4"gap, 1/4" w 19 0.460 0 13.3 256 10.1 194 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50% outdoor insect screen;15 ft overhang(1.6 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4" w 37 0.490 0 14.2 526 20.0 742 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45",medium;50% outdoor insect screen;6 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr,1/4"gap, 1/4" w 96 0.530 0 15.4 1476 26.2 2515 thk:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);50%blinds 45°,medium;50% outdoor insect screen;1.5 ft overhang(8 ft window ht,3 ft sep.);6.67 ft head ht Doors 11DO:Door,wd sc type n 23 0.390 0 11.3 256 11.4 259 • e 22 0.390 0 11.3 249 11.4 251 w 23 0.390 0 11.3 256 11.4 259 n 23 0.390 0 11.3 256 11.4 259 all 90 0.390 0 11.3 1018 11.4 1028 Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 cell ins, 1/2" 2455 0.032 30.0 0.93 2278 1.05 2577 gypsum board int fnsh wri htSOftw 2017Jul-1716:56:08 �� 9 Right-Suile®Universal 2017 17.0.04 RS000269 ..oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E Page 2 Floors 22A-cpm:Bg floor,heavy dry or light damp soil,on grade depth,carpet 111 1.180 0 34.2 3790 0 0 fir fnsh 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile fir 101 1.180 0 34.2 3448 0 0 fnsh Wrl htsoft, 2017-Jul-1716.56:08 9 Right-Suite®Universal 2017 17.0.04 RS000269 �� Page 3 ...oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJB Front Door faces: E Pro ect Summary Job: Tacoma Lot-91 1 1 Date: 7-5-17 Entire House By: Skyetec Project Information For: GHO Homes 2801 Bent Pine Dr., Fort Pierce, FL 34951 Notes: Design Information Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32296 Btuh Structure 28524 Btuh Ducts 10471 Btuh Ducts 12756 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 42767 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 39381 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 8817 Btuh Ducts 3839 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 2455 2455 Equipment latent load 12655 Btuh Volume(ft') 25191 25191 Air changes/hour 0.32 0.16 Equipment total load 52036 Btuh Equiv.AVF (cfm) 134 67 Req. total capacity at 0.80 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM; RUUD Model Cond RA1660AJ1 AHRI ref Coil RH1T6024STAN AHRI ref 7943714 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.3 kW Sensible cooling 46400 Btuh Heating output 41975 Btuh Latent cooling 11600 Btuh Temperature rise 20 °F Total cooling 58000 Btuh Actual air flow 1900 cfm Actual air flow 1900 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.77 Bold/Italic values have been manually overridden Calculations approved by AC CA to meet all requirements of Manual J 8th Ed. t +� wrightsoft- 2017-Jul-1716:56:08 Ptak Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 ...oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E N V '\ Tocoma 12 z 12 _. I`. 8Z 206 dm y Nook 8 x 8 Master Suite I, 34 dm i. • lox 10 - 30x 18 Ox16—j - L- 138 dm 138 dm aedrlxlm 3 8',10.9 8',9,7N 9',10.3N�_ /7',5.5ft \ 12x 12� tOx 10 4".1.7If 215 dm 105 dm 18 dmm 6x6 6z -His_ - 14 12x 12 1 4dm _ --12x12 4 59k � 166dm � r ..;... Great Room --18",420 - 9',8.5 ft rt 6 x 6 115 10 x 10 11 dm i 6x6 \ \ 279',10.0N 18'13.5ft 113 dm II 12",24.6N ggI 31 dm � �•� � - ''��10",13.a f�room 2 Schedule 4',5.5 ft �-Master Bath 5',6.411 3V, b F lox 10 Exhaust Fan F eo it 4ncrn, 0 412 12 ---=-- _._ .`.--- - -- © Range Vent O 6 x 6 8",6.1N 9".18.1 N - _ 46 dm Y 44 dm - Dryer Vent D 6,6 12x12 12x12 193 dm 1 Foyer Rheem Equipment 18".10.9If D pen 16'.73.3N —_ 5.0 Ton 16SEER RHIT60 AHU -- - Dinning 5.0 Ton 16 SEER RA1660 Cond 6x6 20',1.8 rt 33 dm - -- 4',4.3 ft T metal dud for 6 x 6 12 z 12 combustion air,this ff 18 dm dud it to terminate !I 5.0 Ton to the roof with a roof cap.. ''.. f Garage _ I r Job #: Tacoma Lot- 91 Scale: 1 : 143 Performed by Skyetec for: Page 1 GHO Homes Right-Suite®Universal 2017 2801 Bent Pine Dr. 17.0.04 RS000269 Fort Pierce, FL 34951 2017-Jul-1716:56:14 ...s\Skytec\Tacoma Lot-91 GR E.rup Duct System Summary Job: Tacoma Lot-91 y Date: 7-5-17 Entire House By: Skyetec • Project Information For: GHO Homes 2801 Bent Pine Dr., Fort Pierce, FL 34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.18 in H2O Available static pressure 0.32 in H2O 0.32 in H2O • Supply/return available pressure 0.196/ 0.124 in H2O 0.196/ 0.124 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 1900 cfm 1900 cfm Total effective length (TEL) 371 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 2 h 1385 62 33 0.124 5.0 OX 0 VIFx 18.3 140.0 St2 Bath 3 h 1977 88 34 0.086 6.0 Ox 0 VIFx 46.9 180.0 st5 Bedroom 2 h 2910 129 113 0.102 7.0 OX O VIFx 31.4 160.0 st4 Bedroom h 2725 121 105 0.090 7.0 Ox0 VIFx 38.4 180.0 st5 Den h 5235 233 193 0.121 9.0 OXO VIFx 31.4 130.0 SO Dinning h 3337 148 148 0.131 8.0 Ox 0 VIFx 19.4 130.0 SO Foyer h 1708 76 48 0.131 5.0 Ox0 VIFx 19.4 130.0 SO Great Room c 4670 117 215 0.101 9.0 OXO VIFx 34.3 160.0 st4 Great Room-A c 4670 117 215 0.088 9.0 Ox 0 VIFx 43.1 180.0 st5 Hers c 78 3 4 0.096 4.0 Ox 0 VIFx 39.5 165.0 st3 His h 1095 49 18 0.094 4.0 Ox 0 VIFx 43.8 165.0 st3 Kitchen c 4077 46 188 0.102 9.0 Ox0 VIFx 32.9 160.0 st4 MECH-A h 730 32 18 0.188 4.0 Ox0 VIFx 4.3 100.0 Master Bath h 1434 64 31 0.094 5.0 Ox 0 VIFx 44.3 165.0 st3 Master Suite-A h 3627 161 138 0.090 8.0 Ox 0 VIFx 48.8 170.0 st3 Master suite-B h 3627 161 138 0.092 8.0 Ox 0 VIFx 47.6 165.0 st3 Nook h 5731 255 206 0.089 10.0 Ox 0 VIFx 41.2 180.0 st5 Utility c 960 15 44 0.131 4.0 Ox 0 VIFx 14.4 135.0 st2 WC h 534 24 11 0.094 4.0 Ox 0 VIFx 43.4 165.0 st3 Bold/italic values have been manually overridden wri htsoft, 2017-Jul-1716:56:08 CA 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 ..oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 581 560 0.086 543 14.0 0 x 0 VinlFlx st4 st3 Peak AVF 461 340 0.090 587 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 918 730 0.090 657 16.0 0 x 0 VinlFlx st4 Peak AVF 873 1075 0.086 608 18.0 0 x 0 VinlFlx st2 st2 Peak AVF 950 1152 0.086 652 18.0 0 x 0 VinlFlx TableReturn Branch Detail Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb8 Ox0 461 340 143.8 0.086 261 1&0 Ox 0 VIFx rst3 • rb4 Ox 0 1439 1560 118.0 0.105 591 22.0 Ox 0 VIFx rst4 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst3 Peak AVF 1900 1900 0.086 871 20.0 0 x 0 VinlFlx rst4 Peak AVF 1439 1560 0.105 883 1&0 0 x 0 VinlFlx rst3 Bold/italic values have been manually overridden wri htsoftA 2017-Jul-17 16:age 2 9 Right-Suite®Universal 2017 17.0.04 RS000289 Page 2 ...oad Calculations\Skytec\Tacoma Lot-91 GR E.rup Calc=MJ8 Front Door faces: E