Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FEDYNIK RENOVATION Builder Name: Street: 3225 MURA DRIVE Permit Office: ST. LUCIE COUNTY MAY 2 0 2019 City, State, Zip: FT: FIERCE, FL, Permit Number: Owner: \\ Jurisdiction: u County, Permitting Design Location: FL, Ford Pierce County: St. Lucie (Florida Clim „ 1. New construction or existing Addition 9. Wall Types (1200.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 936.00 ft2 b. Frame - Wood, Exterior R=11.0 264.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 2(0) d. N/A R= ft2 10. Ceiling Types (1130.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1130.00 ft 2 6. Conditioned floor area above grade (ft2) 1130 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(137.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 145 a. U-Factor: Sgl, U=0.79 107.00 ft2 SHGC: SHGC=0.45 b. U-Factor: Sgl, U=0.65 30.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 . SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.796 ft. Area Weighted Average SHGC: 0.417 14. Hot water systems - a. Electric Cap: 50 gallons 8. Floor Types (1130.0 sgft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1130.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.121 Total Proposed Modified Loads: 37.41 PASS Total Baseline Loads: 38.36 I hereby certify that the plans and specifications covered by Review of the plans and 4�HE spgl this calculation are in compliance with the Florida Energy specifications covered by this _4V _ - 0�, Code. calculation indicates compliance yrq, '' = �O with the Florida Energy Code. ti +rnrr..• '••. •,;::. ,,,,.�``��„ PREPAR D Y: DATE: Before construction is completed this building will be inspected for1-� compliance with Section 553.908 a * �, I hereby certify that this building, as designed, is in complian a Florida Statutes. with the Florida Energy Code. OWNER/AGENT: G7 /� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). REVIEWED FOR ft�ODE COMPLIANCE 1/11/2019 11:37 AM EnergyGauge® USA Section R405.4.1 Compliant So 1 of 5 ST. LUCIE COUNfT FORM R405-2017 INPI-,-. SUMMARY CHEGKLIST REPOR,_ _-' PROJECT Title: FEDYNIK RENOVATION Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1130 Lot # Owner Name: Total Stories: 1 • Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3225 MURA DRIVE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1130 9040 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 1 176 1408 No 2 1 1 Yes Yes Yes 2 BEDROOM 2 160 1280 No 0 1 1 Yes Yes Yes 3 BATH 45 360 No 0 1 Yes Yes Yes 4 KITCHEN 144 1152 Yes 2 1 Yes Yes Yes 5 LIVING ROOM 255 2040 No 0 1 Yes Yes Yes 6 FAMILY ROOM 220 1760 No 0 1 Yes Yes Yes 7 LAUNDRY 66 528 No 0 1 Yes Yes Yes 8 UTILITY 64 512 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 1 27 ft 0 176 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 2 26 ft 0 160 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 12 ft 0 144 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LIVING ROOM 16 ft 0 255 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio FAMILY ROOM 31 ft 0 220 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio LAUNDRY 9 ft 0 66 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio UTILITY 24 ft 0 64 ft2 ---- 0 1 0 1/11/2019 11:37 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPr,--_=,SUMMARY CHECKLIST REPOR � ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1191 ft2 188 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1130 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 1 30 Blown 176 ft2 0.1 Wood 2 Under Attic (Vented) BEDROOM 2 30 Blown 160 ft2 0.1 Wood 3 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 144 ft2 0.1 Wood 5 Under Attic (Vented) LIVING ROOM 30 Blown 255 ft2 0.1 Wood 6 Under Attic (Vented) FAMILY ROOM 30 Blown 220 ft2 0.1 Wood 7 Under Attic (Vented) LAUNDRY 30 Blown 66 ft2 0.1 Wood 8 Under Attic (Vented) UTILITY 30 Blown 64 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Qrnt S10 Wall Typepace 1 E Exterior Concrete Block - Ext InMDROOM 1 5 13 0 8 0 104.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Ext InMffDROOM 1 5 14 0 8 0 112.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext IngffDROOM 2 5 12 0 8 0 96.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext InfiffDROOM 2 5 14 0 8 0 112.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Ext Insul BATH 5 5 0 8 0 40.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block - Ext InsuKITCHEN 5 12 0 8 0 96.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext InddVlNG ROO 5 16 0 8 0 128.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Ext In€iAMILY ROO 5 20 0 8 0 160.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Ext In§iAMILY ROO 5 11 0 8 0 88.0 ft2 0 0 0.6 0 10 N Exterior Frame - Wood LAUNDRY 11 6 0 8 0 48.0 ft2 0 0.25 0.6 0 11 E Exterior Frame - Wood LAUNDRY 11 3 0 8 0 24.0 ft2 0 0.25 0.6 0 12 N Exterior Frame - Wood UTILITY 11 8 0 8 0 64.0 ft2 0 0.25 0.6 0 13 E Exterior Frame - Wood UTILITY 11 8 0 8 0 64.0 ft2 0 0.25 0.6 0 14 S Exterior Frame - Wood UTILITY 11 8 0 8 0 64.0 ft2 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FAMILY ROO None .4 3 7 21 ft2 2 E Insulated UTILITY None .4 3 7 21 ft2 1/11/2019 11:37 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INP',__- �SUIVIMARY CHECKLIST REPOR.. _ WINDOWS Orientation shown is the entered, Proposed orientation. Wall V # Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single 2 W 4 Metal Low-E Single 3 E 5 Metal Single (Clear) 4 E 6 Metal Single (Clear) 5 W 7 Metal Single (Clear) 6 N 8 Metal Single (Clear) 7 W 9 Metal Single (Clear) Yes 0.65 0.3 N 15.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.65 0.3 N 15.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.79 0.45 N 6.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.79 0.45 N 41.0 ft2 8 ft 0 in 1 ft 4 in Yes 0.79 0.45 N 30.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.79 0.45 N 15.0 ft2 2 ft 0 in 1 ft 4 in Yes 0.79 0.45 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA E'gLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1054.7 57.9 108.89 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for Split SEER: 16 29.4 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / ---- Supply ---- V # Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 145 ft2 Attic 55 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 1/11/2019 11:37 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INR,.-- ,SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan [ ] Feb NeatinHJan [X] Feb [ Mar [X] Mar Apr AprfMay4 Ma X] Jun ]Jun [X] Jul [ ] Jul AujXj rj Au Se Sep [ ] Oct [) [ ] Oct []Nov Nov Dec Dec Ventin Jan [ ]Feb [X] Mar [X] A r [ Ma [ j Jun [ ]Jul Aug Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/s .ft. ft2 ft 0.3 UTILITY Name: Rating Compant: Date: T` E 1/11/2019 11:37 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSIl��r: RON INSPECTION COMPONENT C`��_ ERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: FEDYNIK RENOVATION Builder Name: Street: 3225 MURA DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snronkler cover nlates and walls or ceilinas- a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/11/2019 11:37 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL•DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1130 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.759 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.417 14. Heating system: Capacity 27.0 c) Area 7c. 137.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1OB1. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: A041,J Date: 5-1; 0 '� 9 Address of New Home: 3225 MURA DRIVE City/FL Zip: FT. PIERCE, FL 1/11/2019 11:37:48 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1