Loading...
HomeMy WebLinkAboutMobile Home Inspection Reporti1y ? y r6�•i. Y17"'�ps' ... y rr rY�r I o` St. Lucie County Building & Zoning 2 300 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: �,� � R EA Date: (Print or type) Address: 5a(e l �� N A N j Pl�RG� �— Q (Physical Location dT Home) FL�L aR�d T3 3a70 1:�-A 1000lL Year/ MalfiufactureM� 1 / �N / /V Serial #t�l.�L.aj3QQy333a7j� HUD Plate #A&[OD a I5 - 'th _ ( Length Cp Single Double Wind Zone C = In Compliance N = Not in Compliance Fire Safety / Electrical 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring Other _C 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire w GFCI receptacles not where required 5. Electrical Ground: Chassis Main Panel Gas Pipe Page 1 of') ST. LUCIE rpuNTY 5UII.DMr3.,PIV1S19N DATE f+l P.NF� AND P F,FlNi; f i•�G' (MSi�EC:Ttt:1N l'�'I!.._:';E� P' c: /44 ILE Construction C 1. Exit Doors Operable: Front Back Other C 2. Exit Door Locks: Missing Inoperable 3 EgrP,,, V1 Pdny 5 "��+s A � p , , _C 4. Windows: Broken Glass Inoperable C 5. Screens: Missing Damaged --- C 6. Floor System: Joist Decking Area Damaged _ C 7. Interior Paneling: Missing Loose Damaged, C 8. Rodent Proofing: Bottom Board Pipe openings Other C 9. Leaks Apparent: Ceiling Doors Floor Roof _C 10. Vertical tie -down straps: Missing Short Damaged _ 11. Structural modifications since manufactured: YES_ NO_✓ , 12. Walls: Structurally Unsound Loose _Weather tight Plumbing 1. Trap: Missing Not connected Other _ 2. Plumbing fixtures: Missing Not installed Not Vented C_ 3. Relief Valve: Missing Inoperable Other 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning C1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed _ 3. Thermostat: Missing Inoperable Other 4. Air registers: Missing Inoperable 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 R C6. Gas furnace Water heater vent: 1�lissine G7. Return Air: To Furnace To A/C e C 8. Range: Vent Hood Loose LE COPY From rooms G 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO 2. Will a remodeling permit be required? YES NO_J� The provisions or the repair and remodeling code shall ensure safe and'livable housing and shall not be more stringent than those standards required to be met in the manufacture cif mobile homes. Such provisions shall include, but not be 0 ited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety., FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME; WILL BE ALLOWED TO BE MOVED TO ST. LUCIE. COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A;REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: Q Inspected By:5mic wM. -P E. Signature required Shone Number:6_7 THEIR SEAL. License # 3 / 398 STEVEN G. WOOD, P.E. Page 3 of 3 FL LICENSE 34398 980 SULTAN DR. PORT ST LUCIE, FL l Engineers Seal