HomeMy WebLinkAboutConstruction PlansDRAWING NO.SHEET NO.NO. DATE REVISION BY COVER SHEETFL. Cert. of Auth. #8326stillwaterTECHNOLOGIES(407) 206-7223 faxOrlando, Florida 32804(407) 206-72221700 N. Orange Ave.J:\464 Wawa Inc\464182 Wawa Petro #5380 Orange & Kings (St Lucie Co)\Const Plans\464182_G-0 Cover.dwg DateCIVIL SITE PLANN.T.S.(FOR REFERENCE ONLY)PETROLEUM STORAGE AND DISTRIBUTIONSYSTEM CONSTRUCTION PLANSVICINITY SKETCHNLOCATION SKETCHNSITESITEPARCEL ID#(s): 2311-411-0004-000-1STILLWATER TECHNOLOGIES, INC.1700 N, ORANGE AVE., SUITE 100AORLANDO, FL 32804(407) 206-7222; FAX (407) 206-7223CONTACT: Rick Blecha, P.E.EMAIL: rblecha@stillwatertech.comPETROLEUM ENGINEER:APPLICANT:CODE REFERENCES:Wawa #5380 (ORN)Orange Ave. & Kings Hwy. (S.W. Corner)St. Lucie County, FL3 05/15/20 ISSUE FOR BID & PERMIT FAB FR E D ERI CKA. BLECHAPROFESSIONAL ENGI N E ER LI CENSEFLORIDANo. 50701STATE OF1 09/19/14 GENERAL REVISION D.C.V. 2 GENERAL REVISION J.C.F. 1 09/19/14 GENERAL REVISION D.C.V. 2 12/01/18 GENERAL REVISION J.C.F.STILLWATER PROJECT #464-182KNOW WHAT'S BELOWALWAYS CALL 811BEFORE YOU DIGIt's fast. It's free. It's the law.www.callsunshine.com·NFPA 30 (2018) - FLAMMABLE & COMBUSTIBLE LIQUIDS·NFPA 30A (2018) - MOTOR FUEL DISPENSING FACILITIES·PEI/RP 100-17 - RECOMMENDED PRACTICES FORINSTALLATION OF UNDERGROUND LIQUID STORAGE SYSTEMS·NFPA 70, N.E.C. 2017·FLORIDA BUILDING CODE (FBC) 2017 (6th Edition)·FLORIDA FIRE PREVENTION CODE - 6th EditionWAWA, INC7022 TPC DR., SUITE 200ORLANDO, FL 32822(407) 408-6177CONTACT: Scott Kearney, P.E.EMAIL: Scott.Kearney@wawa.comSuite 100A NO.DATEREVISIONBYTANK DETAILS DRAWING NO. SHEET NO.DateFREDERICK A. B L E CHAPROF E SSIONA L E N G INEERL I C E NSE FLOR I D A No. 50701 STATE OF 307/31/19GENERAL REVISIONFAB109/19/14GENERAL REVISIOND.C.V.2GENERAL REVISIONJ.C.F.109/19/14GENERAL REVISIOND.C.V.212/01/18GENERAL REVISIONJ.C.F.FL. Cert. of Auth. #8326 stillwaterTECHNOLOGIES (407) 206-7223 fax Orlando, Florida 32804 (407) 206-7222 1700 N. Orange Ave. Suite 100A STILLWATER PROJECT #464-182 TANK DETAILSDRAWING NO.SHEET NO.NO.DATE REVISION BYDateFR E D ERI CK A. BLECHAPROFESSIONAL ENGI N EER LI CENSEFLORIDANo. 50701STATE OF3 07/31/19 GENERAL REVISION FAB 1 09/19/14 GENERAL REVISION D.C.V. 2 GENERAL REVISION J.C.F. 1 09/19/14 GENERAL REVISION D.C.V. 2 12/01/18 GENERAL REVISION J.C.F.FL. Cert. of Auth. #8326stillwaterTECHNOLOGIES(407) 206-7223 faxOrlando, Florida 32804(407) 206-72221700 N. Orange Ave.Suite 100ASTILLWATER PROJECT #464-182 S-15 S-16 S-17 S. KINGS HWY.F85 F/B 2020.00 (6,119 SF)ZONING: CGLAND USE: MXD12' x 30'LOADING ZONEE 185'12'12'GEN1615141387651211 1094321STORESTOREJ:\464 Wawa Inc\464182 Wawa Petro #5380 Orange & Kings (St Lucie Co)\Const Plans\464182_G-3 MPD Details-Stack 8 (1-20k+2-22k).dwg DRAWING NO.SHEET NO.',S3E1SER'ET$,/SST$&.E'NO.DATE REVISION BYDateFR E D ERI CK A. BLECHAPROFESSIONAL ENGI N E ER LI CENSEFLORIDANo. 50701STATE OF3 03/27/19 GENERAL REVISION FAB 1 2 GENERAL REVISION J.C.F.1 2 12/01/18 GENERAL REVISION J.C.F. 05/15/20 ISSUE FOR /BID/PERMIT FABFL. Cert. of Auth. #8326stillwaterTECHNOLOGIES(407) 206-7223 faxOrlando, Florida 32804(407) 206-72221700 N. Orange Ave.Suite 100ASTILLWATER PROJECT #464-182 DRAWING NO.SHEET NO.TANK SUMP & RISER DETAILSNO.DATE REVISION BYDateFR E D ERI CK A. BLECHAPROFESSIONAL ENGI N EER LI CENSEFLORIDANo. 50701STATE OF3 07/31/19 GENERAL REVISION FAB 1 09/19/14 GENERAL REVISION D.C.V. 2 GENERAL REVISION J.C.F. 1 09/19/14 GENERAL REVISION D.C.V. 2 12/01/18 GENERAL REVISION J.C.F.FL. Cert. of Auth. #8326stillwaterTECHNOLOGIES(407) 206-7223 faxOrlando, Florida 32804(407) 206-72221700 N. Orange Ave.Suite 100ASTILLWATER PROJECT #464-182 NOTES & LEGEND DRAWING NO. SHEET NO.NO.DATEREVISIONBYDateFREDERICK A. B L E CHAPROF E SSIONA L E N G INEERL I C E NSE FLOR I D A No. 50701 STATE OF 307/31/19GENERAL REVISIONFAB109/19/14GENERAL REVISIOND.C.V.2GENERAL REVISIONJ.C.F.109/19/14GENERAL REVISIOND.C.V.212/01/18GENERAL REVISIONJ.C.F.FL. Cert. of Auth. #8326 stillwaterTECHNOLOGIES (407) 206-7223 fax Orlando, Florida 32804 (407) 206-7222 1700 N. Orange Ave. Suite 100A STILLWATER PROJECT #464-182 1AB234CDEXTENTS OFCANOPY ABOVE, TYP.PER CIVIL (EXTENTS OF CONCRETE SLAB)PER CIVIL (EXTENTS OF CONCRETE SLAB)14'-0"34'-0"34'-0"34'-0"14'-0"2'-0"(TYP.)2'-0"(TYP.)6'-8"12'-0"18'-0"12'-0"6'-4"55'-0"(EXTENTS OF CANOPY TRIM)130'-0"(EXTENTS OF CANOPY TRIM)6 MIL MIN. VAPORBARRIER OVERPRODUCT LINES, TYP.EXTENTS OFCONCRETE SLAB, TYP.MPD ISLAND MPD ISLAND MPD ISLAND MPD ISLAND MPD ISLAND MPD ISLAND MPD ISLAND MPD ISLAND 14'-6"CONSTRUCTIONJOINT, TYP.HAND TOOLED CONTROLJOINT AT COLUMNS, TYP.ISOLATION JOINT, TYP.3'-0"10'-4"10'-4"10'-4"3'-0"10'-4"10'-4"10'-4"3'-0"10'-4"10'-4"10'-4"3'-0"14'-6"8'-8"12'-0"9'-0"9'-0"12'-0"8'-4"COLUMNS, TYP.CONTROL JOINT, TYP.6 MIL MIN. VAPORBARRIER OVERPRODUCT LINES, TYP.MPD ISLAND MPD ISLAND24" LONG #4 TIE BARSAT 30" O.C., TYP.BOLLARD, TYP.CONCRETE WITH MACRO FIBER, TYP.NTSHEAVY DUTYCONCRETE PAVEMENTTYPICAL CROSS SECTIONCANOPY AREANTSHEAVY DUTY CONCRETEPAVEMENT TYPICAL CROSS SECTIONTANK FIELD AREA8" CONCRETE (MIN 4000 PSI)12" FDOT TYPE B STABILIZED SUBGRADELBR 40, FDOT 160-2(PETROLEUM CONTRACTOR TO EXCAVATEAS REQUIRED AND REPLACE WITH BACKFILLAS SPECIFIED ON PETROLEUM PLANS)8" CONCRETE (MIN 4000 PSI)12" FDOT TYPE B STABILIZED SUBGRADELBR 40, FDOT 160-2(PETROLEUM CONTRACTOR TO EXCAVATEAS REQUIRED AND REPLACE WITH BACKFILLAS SPECIFIED ON PETROLEUM PLANS)NOTE: TO BE CONSTRUCTED PER FDOT SPECIFICATIONS(SECTIONS 350) AND GEOTECHNICAL ENGINEERING REPORTNOTE: TO BE CONSTRUCTED PER FDOT SPECIFICATIONS (SECTIONS 350)AND GEOTECHNICAL ENGINEERING REPORTISOLATION JOINT DETAIL CONTROL JOINT DETAIL1/4" MAX.NOTE: SEE THIS SHEET FOR CANOPY AREAJOINT LOCATIONS, AND SHEET "G-1" FORTANK SLAB JOINT LOCATIONSNTSCONCRETE JOINT DETAILS12 " SEALTIGHT SNAP CAP TO BE FILLEDWITH FUEL RESISTANT CAULK AFTERCURING12 " ASPHALT IMPREGNATEDOR RUBBER EXPANSIONMATERIALSTRUCTURE1 12 " DEEP TOOL JOINTTO BE FILLED WITHFUEL RESISTANTCAULKAT STRUCTURES SUCH AS GAS ISLANDS, BUILDINGCANOPY COLUMNS, ETC.CONSTRUCTION JOINT DETAILPLATE DOWEL (TYP.)(W/ FORM ANDSPACING ASRECOMMENDED)THICKNESSPERSECTIONS6" AT CENTER5" MIN.7" MAXNTSPUMP ISLAND GRADING DETAILSEE PETROLEUM PLANS FORPUMP ISLAND DETAILSCONCRETENOTE: PETROLEUM CONTRACTOR SHALL CONFIRM ALL CONCRETEINSTALLATION DETAILS BY REFERENCING CIVIL PLANS PRIOR TO CONSTRUCTIONDRAWING NO.SHEET NO.DateFR E D ERI CK A. BLECHAPROFESSIONAL ENGI N EER LI CENSEFLORIDANo. 50701STATE OFCONCRETE DETAILSNO.DATE REVISION BY 3 07/31/19 GENERAL REVISION FAB 1 09/19/14 GENERAL REVISION D.C.V. 2 GENERAL REVISION J.C.F. 1 09/19/14 GENERAL REVISION D.C.V. 2 12/01/18 GENERAL REVISION J.C.F.FL. Cert. of Auth. #8326stillwaterTECHNOLOGIES(407) 206-7223 faxOrlando, Florida 32804(407) 206-72221700 N. Orange Ave.Suite 100ASTILLWATER PROJECT #464-182