HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
File Copy
Business : Professional Regulation
Fhida DrelppltOl2fltd OMHome I Log In I user Registratm I Hot ToprCs I submR surcharge I Bata a facts I Pubrkations Staff! FBC sta I acts Ste FtaP ! Unim i Search i
BUSII IcS Product CONCEALED FASTENERS ORATTACHMENT'
Professll useR P�dkuaer
Regulation 4RE THE RESPONSIBILITY OF THF,
Product AOorov�HerW>Product or Aoorkatton Seard�>Awlfratlon List>Applkatlon Datill
r FL FL2569-R11
COPTRACTOR of woprl
�
Application Type Revision
Code Version 2014
Application Status Approved
` rNESE PLANS AND -LL PROPOSED WORD
Comments
Archived ❑ • ARE WUDJECT TO ANY CORRECTIONS
Product Manufacturer Soprema,Inc.(Canada) i REQUIRED DY MELD INSPECTORS THAT k��A
Address/Phone/Email Drummondvi1640 rue Haggerty -;°!.iYY NECESAR�(IN;ORDER TO,
(819)478-24i00 NE t 33 00000 'C01' PLy,IWTH tiLLirnpPLICA L BODES,memathieu@soprema ca T
Authorized Signature Marc-Etienne Mathieu
memathieuosoprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1668 lea n-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ed3327 -���� o%4
__..____mematlhieu@soprema.ra S<L..LUCIV Ct}YT-7 To
RFVIFAi k 0 FOR
Quality Assurance Representative Jean-Francois Cote,Ph.D. K- , ir
U--
Address/Phone/Emall 1640 rue Haggarty
c i'L
Drummondville DA
(888)811-3145 PL:k\S \D 'E1611T MUST RE KEPT G\J0
]fcote*soprema.ca OR\`A LNSPE1-_T!CN WILL E E E.
Category Roofing
Subcategory Undertayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Q Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert 1.M.Nleminen
r the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R11 COI 2015 01 COI Nleminen.Ddf
_ Referenced Standard and Year(of Standard) Standard YJ�L
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
https://floridabuiiding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 108Erx... 1/21/2016
Florida Building Code Onli* Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
a Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
FL# Model,Number or DeAripuon
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Unfits of use Installation Instructions
Approved for use in HVHZ:No FL2569 R11 11 2015 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZ:Yes R11.odf
Impact Resistant:N/A Verlfled By:Robert Nleminen,P.E.PE-59166
Design Pressure:+N/A/-90 Created by Independent Third Party:Yes
Othen 1.)Refer to ER Section 5 for Evaluation Reports
Omits of Use.2.)The design pressure FL2569 R11 AE 2015 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
noted herein pertains to underlayment R11.Ddf
systems used beneath adhesive-set tile Created try Independent Third Party:Yes
systems.Refer to ER Section S.6.4 for
details.
i
Canted tls;:1940 North Monroe Street.Tallahassee R 32W Phorw:850-487-1824
The Sete of Fonda is an AA/Em employer.Sobyrioht 2007-2013 state of Florida.::P ;;AccessibllU Stttement::Refund Statement
under Florida law,ernal addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mall to this entity.hatead,contact the office by Phone or by traditional mail.If you have any Questions,Please contact 1150.487.1395.`Pursuant to
Section 455.275(d),Ftortda statutes,Wredwe October 1,2012,licensees,Rbenaed under Chapter 455,F.S.must provide the Department with an emall address r
they have one.The emals provided may be used for official communication with the Irersee.However emal addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an emall address which can be made avelfa ble to the public.To determine If you are a Ikesee under
1
Chapter 455,F.S.,please disk Lips.
i Product Approve Aam ma
Rapfa:
1
stated u:TMi
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB l08Erx... 1/21/2016
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#SQ4
TRIN' ITY I 353 CHRISTIAN STREET, 06473
QOERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-119
1640 rue.Haggerty FL2569-R11
Drummondville;Quebec.12C 5P8 Date of Issuance:06/15/2009
Canada Revision 9:10/12/2015
SCOPE:
This Evaluation Report Is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P:E. for use of the product under the Florida Building Code and Florida Buliding Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted-herein,
DESCRIPTION: Soprema Roof Underlayments
LAeaim- labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTiNUED COMPLIANCE:This Evaluation Report is valld until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,orprovisions of the Code that relate to the product change.. Acceptance of
this Evaluation Report, by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Reportrelative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words 'Trinity IERD Evaluated" may be displayed in
advertising literature. if any,portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this.entire.Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available fortnspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
i
Prepared by:
444
Robert J.M.Nieminen,P.E. TMe+�4e�I.avvdrww�a�+;awsrl,�RMemher.
;'� tJ t�v'''•• P.E.on z0limais.Thlsdoes notmwasanelBa+a+lalwslokd
Florida Registration No,59166,Florida DCAANE1983 goas"rit srpred,sealsdhardmPles have beeritnr&n1udtothe
4
Product AppromIA"nistratorardtothemmaealam
CERTIFICATION OF 114MKNMNCE:
1. TrinitylERD does not have,nor does it intend to acquire-or will it acquire,a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
S. This is a building code evaluation. Neither Trinityi ERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underiayment
Compliance Statement: Roof Underlayments, as produced by Soprema,'have demonstrated compliance with the
following sections of the Florida Building 'Code through testing in accordance with the following Standards.
Compliance is subject to the installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2004
1S07.2.4,1507.2.8, Physical Properties ASTM D1970 2009
15071.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11,2 Physical Properties ASTM D5163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering TAS 110 2000
1507:3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERIENCES:
En Examination Reference Date
ERD(T5T6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD MT60491 Physical Properties 2757,02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
---- —ERD-(T5T6049) _--.._-__.-Wind-Resistance-----_--- .__.__ .-- ____y7.78.07;05 _. ._ ._ -. ._ 07/15/2005 - - --
ERD(TST6049) Wind Resistance 2779.11.05-RS 04/18/2007
ERD(TST60491 TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM 01970/TAS 110 S13190.02,09-111 D4/01/2010
ERD(TS76049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010,
ER0-(T5T6049) Physical Properties/TensileAdhesion 511150.05.30-R1 00/09/2010
i ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05:09-R2 10/05/•2010
i ERD(TST6049.) ASTM D1970 S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD.(M6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014
ERD.(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
1 M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010
I M-D(CER1592) HVHZ Compliance 13-0$30.02 11/27/2014
ICC-ES(EVL2396) 2012,2009.and 2005 IBC Compliance ESR-1524 10/01/2014
PR (TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT'DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering; non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA.SMOOTH PLY 40 is a self-adhering,woven polyethylene surfaced,SBS modified bitumen roof
underlayment;available in 3.3 ft;x 65 ft rolls.
Exterior Research and.Design,I.I.C. Evaluation Report518010..06.09-R9
Cer6fiwe of A++thorkotka 09503 FL2569•R11
Revision 9.10/12/201S
Pop 2of7
��TRINITYJERD
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene.surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SIBS modified
bitumen roof underlayment.
4.7 Lastobond 195 is a self-adhering, glass-neat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.8 Lasto fond 'is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass mat reinforced, film-surfaced,SBS modified bitumen
roof underlayment
4.11 RESISTO 1_IB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 36-inch sheet width.
4.12 PrimeSource Grip-Rite Eave&Valley Protector Is a sell-adhering,glass-mat reinforced,sand-surfaced,SIBS
modified bitumen roof underlayment,with a 36-inchsheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 44-inch sheet width.
4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced,SBS modified bitumen roof
underlayment.
-----'4a5--- —Unilay"(e)-1s a mechanically attached, polyeste"r-reinforced;granule=surfaced;38S-modified-fiitumen roof-"----"
underlayment.
5. WiTATioNs:
5.1 This Is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ
5:3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Undedayments may be used with any prepared roof cover where the product Is specifically
referenced within FBC approval documents. if not listed,a request maybe made to the AHJ.for approval
based on this evaluation combined with supporting data forthe prepared roof covering.
5.5 Allowable roof covers applied atop the undedayments are follows:
As 1 Nall-on Foam On Mt Wood Shakes&
Underlayment Shingles Tile Tile Metal Shingles Slate
Lastobond TU HT Yes Yes Yes See 5,5.1 Yes Yes Yes
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Eiderlor Research and Design,LLG: Evaluation Report 518010.06A9-R9
G+tokate of Authodmtbn 995o3 FL2569-R11
Revision 9;10/12/2015
Pap 3of7
��TRINITYJERD
. .�i i r yYx t. ; Y'�,,i ,i.`.,••-,<s y,- 1"*.3.J'`,r Z tip;- c i`kn- v
Underl Asphalt Nalwin Foam-on Wood Shakes& date
aymeM Metal Shingles Tile Tile Shingles
Laswbond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes No No No Yes Yes
Protector/RESISTO L81244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes Vey No Yes Yes
See 5.5.1
Unilay(e) yes Yes Yes No No No
Batten Only See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of the following adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
Underlayment Adhesives)
Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH=160(FL6332)or Pow Chemical TileBond"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unllay(e) 3M 2-Component Foam Roof Tile Adhesive AH•160(FL6332}
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH..PLY40,Lastobond-Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastabond.195, Lastobond ECO, RESISTO L.B1236, Grip-Rite Eave &
—_VaIITTey ProtiectOr,R1515T0 LB1244 or Lastob4moot nd-Sh Seal HT applied to:
- ----- -
➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41:primed OSB;Southern Yellow Pinee,ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
A Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c If the final roof cover is not slated for installation within
j 24 hours;
➢ Soprema requires tongue-and=groove board decking be covered with plywood or OSS prior to
1 installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
i
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond;Lastobond 195, Lastobond ECO, RESISTO LB3236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244,Lastobond Smooth Seal HT or Colphene FR GR applied to:
D Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared.roof covering manufacturer's Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),Insulation attachment shall be designed.bya qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research*nd.Design,LLC. Evaluation Report318010A6.0949
C&tflota o/Auftiftatfan i85o3 FL2569-R11
Revision 9:10/22/2015
Pop 4 of 7
��TRJNJ-rYJERD
5.6,3 Bond to Mechanically Attached Base laver:
Lastobond Shield,Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond; Lastobond 195, Lastobond ECO, RESISTO 1.81236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244,Lastobond Smooth Seal HT or Colphene PR GR applied to: -
➢ ASTM D226,Type I or 11 felt,Sopra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only),
base layer shall.be attached in accordance with FRSA/TRI April 2012(04-11).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On'Tile Applications; FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of'the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the.2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45X psf.
Deck: Min.15/32-in.ch plywood to meet project requirements to satisfaction of AHJ.
Primer (Optional).Elastocol Stick or Elastocol 600c
Uitderlayment- Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Deslen Pressure=•-67.5 osf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
—5:6:4 3•—Maximum-Design Pressure=--60.0 Dsf_ __ --
Deck., Min.;19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet:. Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-Inch laps and 6-inch o.c.in three,equally
spaced rows in the center of the sheet.
Underlayment: LastobondTU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90:0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction ofAHJ.
1 Underlayment: Unilay(e) mechanically attached with Sopraflx Rolymer Batten Bar (PBB) or Soprafix Metal Batten Bar(MBB)with Soprema 415-EL.fasteners spaced 6-Inch o.c.within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seat HT, RESISTO LB.1236, Grip-Rite Eave &
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond.Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH,PLY 40, Lastobond Shield HT or Lastobond
Pro HT-S shall not be left exposed for longer than 90-days after Installation.
Lastobond TU HT or Colphene FIR GR or Unilay(e)shall not be left exposed for longer than 180-days after
installation..
Exterior Research and Design,U.C: Evaluation Report 518010.06.09-R9
Catlfkate of AuWrfzWoe#9503 Fi2569-RU
Revision 9:10/12/2015
Page 5 of 7
TRINITY J ERQ
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with.Soprema published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking parcels,and check for protruding nail heads. Sweep the substrate.thoroughly
to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or
Elastocol 600c(if applicable),
6.3 Lastobortd TU 14T Lastobond Shield Lastobond Pro HT-N RESISTOSA SMOOTH PLY 40 Lastobond Shield
HY,Lastobond Pro HT-S,Lastobond Lastobond 195,Lastobond Eco.Lastobond Smooth Seal HY.RESISTO
L81216,-Grl"Ite Eave&Valley Protector,RESiSTO LB3244 oeWphene FR.GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507for the type of prepared roof covering to be Installed.
6.3.2 Non-Tile Applications:
While priming is:optional,Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover is not-slated for installation within:24 hours.
Apply sheet-parallel to the roof edge. Roll out.approximately 10 ft of membrane and peel back the first 3
ft'of release film.
Adhere the exposed part to the substrate-and unroll the remaining membrane as far as possible.
Once the entire.length of membrane Is In place, peel-off the release film diagonally while holding the
membrane tight. Firmly rol I the membrane Into place to achieve a bond.
Horizontal seams should be nilnimum 34nche% configured to shed water.- Vertical seams should be 6-
inches and•staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot:air welding teehrilques,
- - When•Insta11Ing at-slopesabove 8;12,5oprema-recommends-back-nailing in the overlaparea a-the top-.of—
the sheet at 12-Inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release.paper and centersheet
over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in
each direction, For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications.(La sto bond TU HT or Colphene FR GRoniy):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
Instructions noted above:as a guideline.
For foam-on the applications,reference Is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
j Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
I underlayment.
6_.4 UnIla e
6.41 Non-Ttle Applications or Nail-On.Battened Tile Applications:.
Reference is made to Table 1 herein and FRSA/TRl April 2012(04-12)Installation Manual.(If applicable).
Apply sheet parallel. to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the S-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-
laps: Vigorous hand or motorized roller pressure is.applied to the self-adhering laps to ensurea watertight
application.
Vertical seams should be 6-Inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-lapsshall besealed using either heat-welding or hot air welding techniques.
Exterior Research and.Design,LLC. Evaluation Report 518010.06 0"9
CwWwte of Audodradon A=3 FL2563RU
Revision 9t 10/12/2015
Page 6 of 7
TRINITY I ERD
Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
6.4.2 Foam-On Tile Applications:
Reference Is made to FRSA/TRI April 2012 (04-12) Installation Manual,Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope,
mechanically attach the.5-inch wide selvedge-edge to the wood deck Soprafix.Polymer Batten,Bar(PBS)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-.EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous.hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 CIA
requirements.
9. QUALiTyASSURANCE ENTITY:
--- ---UI,'LLC-z-QUA9625;(314)578-3406;k.chancellor@us:ul.eoin
-END OF EVALUATION REPORT-
Exterior Research and Design,UC. Evaluation ReportS18010.0649-R9
tatgrabte of Audlottmion 050 FL2569-R11
Revision 91 10/12/2015
Page 7 of 7