revision/ Energy Cal'cs
:. r C r Aer ✓,9�2 �jGFO FORM R405-2017 6'� . FLORIDA ENERGY EFFICIENCY CODE FOR BUILDII ;��� ISTRUCTION Florida Department of Business and Professional Regulation - Residential 96rmance Method Project Name: PEREZ GUEST RESIDENCE-2 Builder Name: Street: ORANGE AVE&BRIDLEWOOD WAY Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, - Permit Number: ! e1Dq-04b d Owner. PEREZ Junsdicti : _ 661000 Design Location: FL,ST LUCIE CO INTL County: SMqFlor ' ate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types 8. qft In _la n 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,E norms 11 8. 0 b.N/A R= ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 1 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (689.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 689.00 ft2 6. Conditioned floor area above grade(ft2) -689 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 , .....,h. 7. Windows(83.5 sqft.) Description Area a.Sup:Attic,Wef'Attic;AH;Main: ? =u L11?- 6,? 137 a. U-Factor. Sgl,default 83.50 ft2 E( SHGC: Tinted,default b. U-Factor: NIA ft2 12.Cooling systems kBtulhr Efficiency SHGC: a.Central Unit 18.0 SEER:15.50 c. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Strip Heat 16A COP:1.00 SHGC: Area Weighted Average Overhang Depth: 5.880 ft. Area Weighted Average SHGC: 0.640 14.Hot water systems ons 8. Floor Types (689.0 sqft.) Insulation Area a.Electric Cap:40gall EF:0.920920 a.Slab-On-Grade Edge Insulation R=0.0 . 689.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.121. Total Proposed Modified Loads: 30.43 PASS Total Baseline Loads: 31.56 I hereby certify that the plans and specifications covered by Review of the plans and 0i-1;1E STATE this calculation are in compliance with the Florida Energy specifications covered by this ✓ Code. calculation indicates compliance V0 with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: - this building will be inspected for °�. compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. COD WE- OWNER/AGENT:-.. BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.25 ACH50(R402.4.1.2). 1/20/2021 11:51 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PEREZ GUEST RESIDENCE Bedrooms: 1 Address Type: Street Address, Building Type: User Conditioned Area: 689 Lot# _ Owner Name: PEREZ Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: ORANGE AVE&BRID Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Single-family FL, - New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5% 2.6% Winter Summer Degree Days Moisture Range FL,ST LUCIE CO_INTL FL VERO BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 689 6201 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 689 6201 Yes 2 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 104 ft 0 689 ft2 ___ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 746 ft2 0 ft2 Light N 0.3 N 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 689 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 Blown 689 ft 0.1 Wood 1/20/2021 3:05 PM EnergyGauge rn USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V. #. .Ornt.. ....To._ :-..WaILType. .. .-._ ... ........ .Space R_Value_ --.Ft-.-.In-..... ..Ft -..In-. ..... Area_.. R Value Fraction Absor..Grade% 1 N Exterior Concrete Block-Int Insul Main 4.1 28 6 9 0 256.5 ftz 2 0 0.8 0 2 E Exterior Concrete Block-Int Insul Main 4.1 24 2 9 0 217.5 ftz 2 0 0.8 0 3 S Exterior Concrete Block-Int Insul Main 4.1 28 6 9 0 256.5 ftz 2 0 0.8 0 _4 W Exterior Concrete Block-Int Insul Main 4.1 24 2 9 0 217.5 ftz 2 0 0.8 0 i DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .4 3 8 24 ftz WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Single(Tinted) No 1.3 0.64 Y 54.0 ftz 8 ft 0 in 1 ft 0 in None None 2 S 3 Metal Single(Tinted) No 1.3 0.64 Y 22.5 ftz 2 ft 0 in 1 ft 0 in None None 3 S 3 Metal Single(Tinted) No 1.3 0.64 Y 7.0 ftz 2 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0003 542.2 29.76 55.98 .109 5.246 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 16.4 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15.5 18 kBtu/hr 540 cfm 0.8 1 sys#1 HOT WATER SYSTEM V. # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 40 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz 1/20/202T 3:05 PM EnergyGauge©USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS --Supply-- ---Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 137 ftZ Attic 0 ft' Default Leakage Main (Default) (Default) No 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [X]Jan JXXJ Feb [X]Mar rj Apr [X]May IXX�Jun [X]Jul [X]Aug [X)Sep [X]Oct [X]Nov [X]Dec Heating X Jan Feb X Mar AprXMayXJun [[X)]Jul X Aug X Sep X Oct X Nov X Dec Venting X Jan X Feb X Mar Apr X May Jun X Jul X Aug X Sep X Oct. X Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 06 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(B lbs/s .ft. 0 fta 0 ft 0.3 Main 1/20/2021 3:05 PM EnergyGauge@ USA 6,0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2011) Compliant Software Page 4 of 4