Loading...
HomeMy WebLinkAboutRevision Energy Cal's r J ✓ _ oon FORM R405-2017Z S�C��' At�1 t Lam( g2 � pal C � . 00 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and'Professional Regulation - Residentiai'Performarnoe Method Project Name: PEREZ RESIDENCE-2 Builder Name: OWNER/BUILDER Street: 200 BRIDLEWOOD WAY Permit Office: ST LUCIE COUNTY City,State,Zip: FT PIERCE,FL,34950 Permit Number:1907-0591 Owner. SANTOS Jurisdiction: 661000 -Design Location: FL,West Palm Beach County: -St.Lucie(Florida Climate-Zone-2) 1. New construction or existing New(From Plans) II T es. 22.5 s ft. Insulation Area a. <o ete B ck } t `su Eaten R1 N5510 ftz 2. Single family ormultiple family Single-family r Z3. Number of units,if multiple family 1 c i re a BI Int su ace ( I R=4.1 44 ft2 _ iftS d.WA 4. Number of Bedrooms 4 � ft 5. Is this a worst case? No 10.Ceiling Types.(3094.0 sgft.) Insulation Area a.Roof Deck(Unvented) R=20.0 3094.00 ftz 6. Conditioned floor area above grade(ftz) 3094 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ft' 7. Windows(456.0 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 240 a. U-Factor: Sgl,U=0.65 45&00 ftz b.Sup: Attic,Ret:Attic,AH:Garage 6 320 SHGC: SHGC=0.25 b. U-;Factor. N/A ftz 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 36.0 SEER:16.00 c. U-Factor. NIA ftz b.Central Unit 42.0 SEER:16.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ftz a.Electric Strip,,Heath b.Electric Stri 32 r'99pi 1.00 SHGC: �e�'a'L ii b �J`i;v� y �` LiL,,�;.'� Area Weighted Average Overhang Depth: 15.693 ft. -Area Weighted Average SHGC: 0.250 14.Hot water systems a.Electric Cap:65 gallons 8. Floor Types (3094.0 sqft.) Insulation Area EF:0.920 a.Stab-On-Grade Edge Insulation R=0.0 3094.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 114.26 Glass/Floor Area: 0.147 Total Baseline Loads: 114.50 PASS. I hereby certify that the plans and specifications covered by Review of the plans and 4-tKE ST.4 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance � :�„ ,`,o�l� •{+ with the Florida Energy Code. -.._rprx• PREPARED BY: Before construction is completed -- DATE: ®l �D, ,-_� }{r'Z4S'j__ this building will be inspected for �' 9 P compliance with Section 553.908 * ' I hereby certify that this build* ed,is in compliance Florida Statutes. with the Florida Energy od D e. U W 1� OWNER/A E T: _ BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 4.50 ACH50(R402.4.1.2). 1/20/2021 3:03 PM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PEREZ RESIDENCE-2 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3094 Lot# Owner Name: SANTOS Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: OWNER/BUILDER Rotate Angle: 0 Street: 200 BRIDLEWOOD WA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: FT PIERCE, Family Type: -Single-family FL, 34950 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design'Location TMY Site -97.5% 2.5% Winter -Summer Degree Days Moisture 'Range FL,West Palm Beach FL WEST PALM BEAC 44 90 70 75 316 60 Medium BLOCKS Number Name Area Volume 1 Blockl 1340 1-6276 2 Block2 1754 17890.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 -LIIVING 1340 15276 Yes 2 0 1 Yes Yes Yes 2 BEDROOMS 1754 17890.8 No 8 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio LIIVING 69 It 0 1340 ft2 r 1 0 0 2 Slab-On-Grade Edge Insulatio BEDROOMS 174 It 0 1754 W 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color . Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3351 ft2 0 ft2 Light N 0.75 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 3094 ft2 N Y 1/20/2021 3:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type -Space RValue Ins Type Area Framing Frac 'truss Type 1 Under Attic(Unvented) LIIVING 0 Blown 1340 ft2 0.11 Wood 2 Under Attic(Unvented) BEDROOMS 0 Blown 1754 ft2 0A II Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below __#_.Omt-_T:n___Wall_'ype Space R 1aluA Et In-_-FA-Jn area--R-Value_Fraction_-lbsor_..Grade°!o_ _ 1 S Exterior Concrete Block-Int Insul LIIVING 4.0999 30 0 11 4 340.0 ft2 2 0 0.75 0 _2 E Exterior Concrete Block-Int Insul LIIVING 4.1 16 4 11 4 185.1 ft2 2 0 0.75 0 _3 N Exterior Concrete Block-Int Insul LIIVING 4.1 27 0 11 4 306.0 ft2 2 0 0.75 0 4 N Exterior Concrete Block-Int InsfHEDROOMS 4.1 16 6 9 4 154.0 ft2 2 0 0.76 0 -_5 E Exterior Concrete Block-Int Ins8EDROOMS 4.1 30 4 11 4 343.8 ft2 2 0 0.75 0 -6 S Exterior Concrete Block-Int InstJIEDROOMS 4.1 34 4 9 4 320.4 ft2 2 0 0.75 0 7 N Exterior Concrete Block-Int InslIEDROOMS 4.1 20 4 11 4 230.4 ft2 2 0 0.75 0 _-8 W -Exterior Concrete-Block--int InsfilEDROOMS -4.1 57.7 9 A 538.5-ft2 2 -0 0.75 0 _9 W Exterior Concrete Block-Int Ins®EDROOMS 4.1 12 4 11 4 139.8 ft2 2 0 0.75 0 _10 E Garage Concrete Black-Int InsfIEDROOMS 4.1 23 4 11 4 264.4 ft2 2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In -Ft -In 1 N Insulated LIIVING Metal .2 6 8 48 ft2 - WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang �/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Single(Tinted) Yes 0.65 0.25 Y 96.0 ft2 14 ft 4 in 3 ft 4 in Drapes/blinds None -2 S 1 Metal Single(Tinted) Yes 0.65 0.25 Y 36.0 ft2 2 It 0 in 3 ft 4 in Drapeslblinds None 3 E 2 Metal Single(Tinted) Yes 0.65 0.25 Y 64.0 ft2 49 It 0 in 3 ft 4 in Drapeslblinds None 4 N 3 Metal Single(Tinted) Yes 0.65 0.25 Y 36.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 5 N 3 Metal Single(Tinted) Yes 0.65 0.25 Y 12.0 ft2 17 ft 0 in 0 ft 6 in Drapes/blinds None -6 S -6 -Metal Single(Tinted) Yes 0.65 0.25 Y 96:0 ft2 14 ft-0-in 3 ft-4 in -Drapes/blinds -None 7 N 7 Metal Single(Tinted) Yes 0.65 0.25 Y 24.0 ft2 2 ft 0 in 3 ft 4 in Drapes/blinds None 8 W 8 Metal Single(Tinted) Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 9 W 8 Metal Single(Tinted) Yes 0.65 0.25 Y 40.0 ft2 2 ft b in 1$4 in brapes)biinds None 10 N 3 Metal Single(Tinted) Yes 0.65 0.25 Y 12.0 ft2 12 It 0 in 1 ft 4 in Drapes/blinds None 11 N 4 Metal Single(Tinted) Yes 0.65 0.25 Y 24.0 ft2 12 It 0 in 1 ft 4 in Drapes/blinds None 12 S 6 Metal Single(Tinted) Yes 0.65 0.25 Y 8.0 W 2 It 0 in 1 It 4 in Drapes/blinds None 1/20/2021 3:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE Floor Area Ceiling Area Exposed Wail'Perimeter Avg.Weill-Height Exposed Wall Insulation _ 1 588 ft2 588 ft2 72 ft 9.3 ft 1 _INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000306 2486.9 136.53 256.76 .1398 4.4988 HEATING SYSTEM # System Type Subtypee _ Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 26.2 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 32.8 kBtu/hr 2 sys4f2 COOLING SYSTEM # System Type _ Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:16 36 kBtu/hr 1200 cfrn 0.75 1 sys#1 -2 Central Unit/ Split Singi SEER:16 42 kBtu/hr 1400 cfm 0.75 2 sys#2 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use WPM Conservation 1 Electric None Garage 0.92 65 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location , R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 240 ft2 Attic 66 ft2 Default Leakage- Garage (befault) (Default') 1 9 2 Attic 6 320 ft2 Attic 90 ft2 Default Leakage Garage (Default) (Default) 2 2 1/20/2021 3:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable-Thermost6tXX:Y [[XX]] 'Ceiling Fans: Dec Cooling Jan (X]Feb [X]Mar Apr�j Ap Rj May XX Jun XI Jul X Aug Sep Occtt Nov C Jul Aug rX1 Sep Oct FXI Nov �Dec Venting Jan X Feb [[�X]l Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(1ND) AM 78 78 -78 78 78 78 78 78 '80 -80 '80 "80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM FM 66 66 66 66 66 68 68 68 68 68 68 68 66_.. __ 68 68 ._ 68---- 68-._..._......_68-.----_6668 66 -- _66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Fans/ERV 50 50 50 50 1-Electric Strip Heat 1% 1-Central Unit Fans/ERV 200 200 200 50 2-Electric Strip Heat 1% 2-Central Unit MASS Mass Type _ Area Thickness Furniture Fraction Space Default 8 lbs/sq.ft. 0 ft' 0 ft 0.3 Main 1/20/2021 3:03 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5