Loading...
HomeMy WebLinkAboutHealth Dept final approval, 2802 GROVE DRSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Anthony Montoya AGENT: Dansar Homes LLC PROPERTY ADDRESS: 2802 Grove Dr Fort Pierce, FL 34981 LOT: 10 BLOCK: APPLICATION #:AP1470368 PERMIT #:56-SF-2043248 DOCUMENT #: FI 1565587 DATE PAID:02/27/2020 FEE PAID:660.00 RECEIPT # :56-PI D-4301560 SUBDIVISION: Grove ID # : 2420-810-0010-000-6 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [01] TANK SIZE [1] 1090.00 [2] [ 02 ] TANK MATERIAL Polypropylene [03] OUTLET DEVICE [04] MULTI -CHAMBERED [L_!j N ] [05] OUTLET FILTER Polylok PL-68 [06] LEGEND 1. 70-143-11DC4 [07] WATERTIGHT [08] LEVEL [09] DEPTH TO LID DRAINFIELD INSTALLATION [10] AREA [1] 384.4 [2] [11] DISTRIBUTION BOX [121 NUMBER OF DRAINLINES [131 DRAINLINE SEPARATION [141 DRAINLINE SLOPE [15] DEPTH OF COVER [161 ELEVATION [ ABOVE / [17] SYSTEM LOCATION [18] DOSING PUMPS [19] AGGREGATE SIZE [20] AGGREGATE EXCESSIVE FINE! [21] AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH [ ] [25] AREA REPLACED [ ] [26] REPLACEMENT MATERIAL Comments: Comments are on page 2. 2. SQFT HEADER X 1. 4.00 2. BELOW ]BM 12.00 CONSTRUCTION [ APPROVED / DISAPPROVED ]: SETBACKS [ ] [27] SURFACE WATER FT [ ] [28] DITCHES FT [ ] [29] PRIVATE WELLS 80 FT [ ] [30] PUBLIC WELLS FT [ ] [31] IRRIGATION WELLS FT [ ] [32] POTABLE WATER 55 FT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [341 PROPERTY LINES 39 FT [ ] [35] OTHER FT FILLED / MOUND SYSTEM [ ] [36] DRAINFIELD COVER ( ] [37] SHOULDERS [ ] (38] SLOPES [ ] [391 STABILIZATION 01/25/2021 ADDITIONAL INFORMATION [ ] [40] UNOBSTRUCTED AREA [ ] [41] STORMWATER RUNOFF [ ] [42] ALARMS [ ] [43] MAINTENANCE AGREEMENT [ ] [44] BUILDING AREA [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING [ ] [47] CONTRACTOR (All County Septic and Plum [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP ABANDONMENT [ ] [49] TANK PUMPED [ ] [50] TANK CRUSHED & FILLED -` St. Lucie CHD n J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / St. Lucie CHD DISAPPROVED ]: Environmental Speciali I Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1470368 EID2043248 DATE: 11 /19/2020 DATE: 01 /25/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1470368 PERMIT #:56-SF-2043248 DOCUMENT #:F11565587 DATE PAID:02/27/2020 FEE PAID:660.00 RECEIPT #:56-PID-4301560 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 3pd. Vew ST, filter, and 2x8+2x9 LONG TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs 9nal inspection for gutter, mound system, and final site grading. ::final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1470368 EID2043248