HomeMy WebLinkAboutHAHN PERMIT APP - 6663 DULCE REALAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 1-29-2021 Permit Number:
f #
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
Building Permit Application
PERMIT TYPE: A/C CHANGE -OUT
PROPOSED IMPROVEMENT LOCATION:
Address: 6663 DULCE REAL AVE
Property Tax ID #: 1306-111-0001-000-0
Site Plan Name:
Project Name:
Commercial Residential X
Lot No._
Block No.
DETAILED DESCRIPTION OF WORK:
LIKE FOR LIKE REPLACEMENT OF (1) 3.5 TON TRANE A/C SYSTEM, 16 SEER WITH 10 KW ELECTRIC HEAT.
CONNECT TO EXISTING REFRIGERANT LINES, DRAIN, DUCTWORK, HIGH AND LOW VOLTAGE ELECTRIC.
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit —check all that apply:
Mechanical —Gas Tank _Gas Piping _Shutters Windows/Doors
Fiectric — Plumbing _ Sprinklers _ Generator _ Roof Pitch
Total Sq. Ft of Construction:
Cost of Construction: $ 5,150.00
Sq. Ft. of First Floor:
Utilities: —Sewer —Septic Building Height:
OWNERAESSEE: CONTRACTOR:.
Name WYNNE CORP (NANCY HAHN) Name: JAMES F. GRIMES
Address: 6663 DULCE REAL AVE Company: GRIMES HEATING AND AIR CONDITIONING
City: FORT PIERCE State: i— Address: 3054 N US HWY 1
34951 FORT PIERCE State: FL
Zip Code: Fax: City:
Phone No. 772-464-2110 Zip Code: 34946 Fax: 772-461-8722
E-Mail: NA Phone No 772-461-8711
Fill in fee simple Title Holder on next page ( if different E-Mail ROBERTGRiMESAC ,AOL.COM
from the Owner listed above) State or County License 4426
If value of construction is $25uu or more, a KtI.UKUCU Nutlr C vi %.V1111INUN MOPINUN1 , �y,...�...
If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
s .-
C'EER:_Not Applicable
MORTGAGE COMPANY:
� Not Appiica e
DESIGN ERJENGIN
Name:
Blame:
Address:Cit
Address:
State:
y:
State:
City:
Phone
Phone:
Zip: -
Zip:
Not App lleaE3ie
BONDING COMPANY -
IV Applicable
FEE SIMPLE TITLEHOLDER:
_
Name:
Name:
Name:
Address:
Address:
City:
City:
Zip: Phone:
Zip_ Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated_
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie Caunty makes no representation that is granting a permit will authorize the permit holder at build the subject structure
which is in conflict with any applicable Home owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Name Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that t will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The foilowing building permit applications are exempt from undergoing a full concurrency review; room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWI1fElt: FAILURE Uli PROPERTY iYRECORD A OTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
N, NOTICE OF COMMENCEMENT MUST BE RECORDED AND
TWICE FOR IMPROVEMENTS
ip05TFD ON THE -IR OR Alit A RNi BEFORE RECORDING YOUR NNOTI C OF COMM�IGEM R9CI�1G, C(DNSI IL
WITH YOUR LENDS
S- ature of Owner% Lessee/Contractor as Agent for owner
STATE OF FLORIDA. t�
COUNTYOF
The fnr Wing instrumQ t wa- acknowledged before me
this,day of — 20�� by
Name of person making statement.
Personally Known OR Produced identification
Type of Identification
Produced
re of Notary Public- State
11,
"1 . {S AN MONTENEGRO
commission Na. My COMMISSION # GG 089
REVIEWS CD FRONT'� ER R�EVIPN ,REVIEW
IATE i
C
Si ature of Contractor License holder
STATE OF FLORIDA !
COUNTY OF
The fo��aing rostrum nt was acknowledged before me
this _a day of 'h 201 by
G-r i
Name of person making statement.
Personally Known )!�— OR Produced Identification
Type of Identification
Produced
. nature of Notary Public- State of Florida) U
Sut5,"DNTENEGR0
remission Na. c = My GflMMJ88 10N s CG UB9099
uonded 11inj W N PuhrsC UWCFw tei5
NS VEGETATI
REVIEW REVIEW REVIEW REVIEW
This combination qualifies for a Federal Energy Efficiency tax Credit when
placed in service between Feb 17,2009 and Dec 31, 2016.
Certificate of Product Ratings
AHRI Certified Reference Number: 8703699 Date : 03-01-2019 Model Status: Active
AHRI Type: RCU-A-CB
Series : XR16
Outdoor Unit Brand Name: TRANE
Outdoor Unit Model Number (Condenser or Single Package) : 4TTR6042J1
Indoor Unit Model Number (Evaporator and/or Air Handler) : TEM4AOC42S41+TDR
Region: Ail (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS,
MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S.
Territories)
Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions
until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for
which they meet the regional efficiency requirement.
The manufacturer of this TRANE product is responsible for the rating of this system combination.
Rated as follows in accordance with the latest edition of ANSIIAHRI 2101240 with Addenda 1 and 2, Performance Rating of Unitary
Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing:
Cooling Capacity (A2) - Single or High Stage (95F), btuh : 41000
SEER: WOO
EER (A2) - Single or High Stage (95F) : 13.00
t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced"Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering #or sale.
Rat,n s that are acoom anied b WAS indicate an involunta re -rate. The new ublished ratin is shown alon with the previous i.e. WAS ratincl,
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed On this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated;
entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, AIR-CONDITIONING, HEATING,
personal and confidential reference. & REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahrldirectory.org, click on `Verify Certificate" link µ�- make life better"
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above, and the Certificate No., which is listed at bottom right. 131959228876420661
©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.;