HomeMy WebLinkAboutTruss PlanARROW ON THE TRUSS REPRESENTS ITS LEFT END
Hatch Legend
8'-0" BRG.
HT.
11'-4" BRG.
lI HT.
3/12'
�z VAULTED
8" RECESS
Builders FirstSource
1602 INDUSTRIAL PARK DR
PLANT CITY FL
Phone: (813) 759-5922
Fax: (813) 752-1532
hftp://www.bldr.com
General Notes:
- Per ANSI/TPI 1-2007 all " Truss to Wall"
connections are the responsibility of the Building
Designer, not the Truss Manufacturer.
- Dimensions are Feet -Inches- Sixteenths.
- Trusses are to be 24" o.c. unless noted
otherwise (U.N.O.)
- Trusses are not designed to support brick U.N.O.
- Do not cut or modify trusses without first
contacting Builders FirstSource.
- Immediately contact Builders FirstSource if
trusses are damaged.
Connection Notes:
- All hangers are to be Simpson or equivalent
U.N.O.
- Use Manufacturer's specifications for all hanger
connections U.N.O.
- Use 10d x 1 1/2" Nails in hanger connections to
single ply roof girder trusses.
Floor Truss Notes:
- Shift truss as required to avoid plumbing traps.
- Installation Contractor and/or Field Supervisor
are to verify all dimensions, trap locations, and
options prior to installation
Dimension Notes:
- Drawing not to scale. Do not scale dimensions
Roof:
TCLL: 20
PSF
TCDL: 7
PSF
BCDL: 10
PSF
Floor:
TCLL: 40
PSF
TCDL: 10
PSF
BCDL: 5
PSF
Wind:
Velocity: 160 MPH
Exp. Cat.:
C
Risk
Cat.:
II
Roof pitch: 6/12
Overhang:
RENAR BUILDERS, LLC.
CURRY/DE LA CRUZ
RESIDENCE
CAYMAN 1560 131
9520 SILVER SANDS LANE
FT. PIERCE, FL.
Designed by: IO
Layout: 2546975TP_LAY
Date: 11/23/20
Revision History:
Rev 1:
Rev2:
Rev3 :
omments:
NOT TO SCALE
3HEEI
1 of 1
c-I c. A-l2oal73Dr