Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
doc03558620210129093928 Underlayment 1.29.21
1/20/2021 Florida Building Code Online a, .f+ BCIs Home Log In I user Registration Hot Topics$ Submit Surcharge Slats&Facts ( Publications �i Contact Us +E BCIS Site Map finks Search I [1)(Ida Product Approval USER:Public User Product ARDroyal Menu>Product or AD lication Search>Ailplication List>Application Detail + FL# FL2569-R20 a Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Soprema,Inc.(Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu @soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville,NON-US 00000 (819)478-2400 Ext3327 memathieu@soprema.ca Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/10/2023 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL2569 R20 COI 2020 01 COI NIEMINEN.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2015 FM 4474 2011 FRSA/TRI Sixth Edition 2018 UL1897 2012 https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xYlmjtmBrpDan9H30QGunUKXA%3d*/o3d 1/2 1/2 012 02 1 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/19/2020 Date Validated 09/22/2020 Date Pending FBC Approval 09/29/2020 Date Approved 12/15/2020 Date Revised 12/16/2020 Summary of Products FL# Model,Number or Name Description 2569.1 Soprema Roof Underlayments Self adhering roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R20 II 2020 09 17 FINAL ER FL2569-R20.pd Approved for use outside HVHZ:Yes Verified By: Robert Nieminen,P.E.PE-59166 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-150 Evaluation Reports Other:1.)Refer to ER Section 5 for Limits of Use. 2.)The FL2569 R20 AE 2020 09 17 FINAL ER FL2569-R20.pdff design pressure noted herein pertains to underlayment systems Created by Independent Third Party:Yes used beneath adhesive-set the systems.Refer to ER Section 5.6.4 for details. aa�x uert Contact Us::2601 Blair Stone Road,Tallahassft FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer,Copyright 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 650.487.1395.*Pursuant to Section 455.275(i), Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® ib Im Credit Card Safe CEO= https://www.floridabuilding.org/pr/pr app_ d.aspx?param=wGEVXQwtDgsKQFEnckB108ErxlUd3xY(mjtmBrpDan9H30OGunUKXAa/o3d°/o3d 2/2 NEMOUetc. Certificate ofAmhomatiom#32455 3S3 Christian Street,Unit#I3 Oxford,[rO647 0 (203)262'9245 Emo/mcEn EvmLuAre Tss7 Comsucr Soprema,Inc. Evaluation Report S18010.06.09-1118 164O rue Haggerty FL2569'R20 Drummondville,Ow6bec]ZCSPD Canada Date of Issuance:06/15/2009 ' (819)478'2400 Revision 18:D9/17/2]2Q Scops: This Evaluation Report is issued under Rule 61G20'3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2820)Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Nn6udaynments Lxoeumo: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC1SO7.1.1. Comnwuso[ompuxmCuThisEvaivationQepurtisuoUJund|suchdmeasthenamedpvoduc¢(s)ohangas,thereferenced Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notifyNEK4O ETC, LLCofany changes to the pnoduct(s)' the Quality Assurance or the production facility|ocation(s). NEKAOETl, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. Auvsnxssxxcxn/TheF|nridaProduc1Appnova| Number(FL#) precededbythewmnds"NEyWOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. |mspcCTIom: Uponrequest,acopyofthisentioeEva|uat|onReportshaU6eprovidedtutheuserbythemanutacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 5-4 ~~~__ Rube�1&A,0��m�e���. ' m°a�=�s� authorized by Robert mc�"�.p�m,owsvz�on,�um�°* Rv��xey�6ammmz5y�6�Fkv�aocmAm�so3 - --. serve as =electronically signed document. csnnnc^nommINDEPENDENCE: z. NEW ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interesti"any company manufacturing nr distributing products uevaluates. z. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. u. Robert wiemmen'p.s.does not have nor will acquire,a financial interest in any company manufacturing nr distributing products for which the evaluation reports are being issued. «. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. s. This isa building code evaluation. Neither wsmoETC,Luc nor Robert mieminen'p.s.are,m any way,the Designer v[Record for any project vn which this Evaluation Report,n,previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. mzmywemnErcuc ONEMOletc. ROOFING COMPONENT EVALUATION: a• Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments,as produced by Soprema,have demonstrated compliance with the following sections of the 71h Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. PEEa••t Section Pro a Stan 00101m ,dard year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2012 1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015 /R905.1.1,R905.2.8.2 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2 J R905.11.2 Material standard ASTM D6163 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity- ERDExaoninatian Re€erence Date (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010 ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011 ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011 ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013 ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970(BC) 544870.04.14-2 04/02/2014 ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014 ERD(TST6049) ASTM D1970(OH) 544870.04.14-1 04/10/2014 ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014 ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014 ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017 M-D(CER1592) HVHZ Compliance 18-0329.03 06/29/2018 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO(TST6049) ASTM D4798/1)1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-19-SSUDL-04.A 03/12/2020 PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019 UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020 NEMO ETC,LLC Evaluation Report S18010.06.09-1118 CertlficateofAuthorization#32455 7"EDITION(2020)F8C NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 2 of 8 NNEMOjetc. rimBH D 0 Material Product Plan#(s) Description Standard 4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric FRSA/TRI 09-18 surfaced,SBS modified bitumen roof underlayment 4.2 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS 40 modified bitumen roof underlayment 4.4 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.6 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.7 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.8 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand- Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand- Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.10 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Gulfport,MS surfaced,SBS modified bitumen roof woh,OH underia me 4.11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film- HT Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film- Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.15 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.16 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment NEMO ETC,LLC Evaluation Report S18010.06.09-1118 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL2569-1120 Soprema Roof Underlayments Revision 18:09/17/2020 Page 3 of 8 ONEMOletc. Material Product Plant(s) Description Standard 4.17 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule- Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TALE 1; ROOF'Ct)V£R fJifTlONS Gay and Concrete Tile state or Asphalt Metal Wood Underlayment Shingles AMU) Slate-Type Mechanical Adhesive- Panels Shingles Shingles Shingles {isozz) s shakes{iso�s) Attach set (iso7a) (1507s) tlso7) (1so7.aj Yes Yes Yes Lastobond TU HT Yes Yes Yes Yes Yes See 5.6.1 (Joint strips,3507.1.1.3 (joint scrips,1507.2.1.3 (R905.1.1.3) /R905.1.1.3) Lastobond Shield/Pro HT-N Yes Yes /RESISTO SA SMOOTH PLY Yes No No No No Yes (joint strip£2507.1.2.3 (joint strips,1507.1.1.3 40 J R9053.1.3) /R905.1.1.3) Lastobond Shield HT/Pro Yes Yes HT-S Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 /MS,1.1.3) /R905.11.3) Yes Yes EnviroShield Yes No No Yes Yes Yes (joint strips,1507.1.1.3 (taint strips,1507.1.13 J R90S.1.1.3) /R905.1.1.3) Lastobond Eaves Protection Yes Yes Sheet/Lastobond 195 -. Yes. No No No No Yes (joint strips,1507A.1,3 (joint strips,1507.1.33 J R405.1.1.3) /R9053.13) Lastobond ECO /RESISTO LB1236,Grip-Rite Eave& Yes Yes Valley Protector/TopShield Yes No No No No Yes (joint strips,1507.1.1.3 (faint strips,IS07.1.1.3 ICE&WATER DEFENDER/ lR905.1.1.3) /R9os.1.1.3) RESISTO LB1244 Lastobond Smooth Sea HT J Yes Yes Grip-Rite Smooth Seat HT Yes No No Yes Yes r. Yes (Joint strips,IS07.1.1.3 (joint strips,1507.1.1.3 Yes es Colphene FR GR Yes Yes No No No Yes (faint snips,1507.1.1.3 (joint strips,1507.1.1.3 /R905.1.13) /R905.1.1.3) NEMO ETC,LLC Evaluation Report SI8010.06.09-1118 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 4 of 8 NNEMOjetc. 5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations. TABLE IA ALLOWABLE;TILE ADHESIVE IJN DE LAYN'ENTI W iBINATiON51 Underiayment Adfiesiye Florida Product Approval Lastobond TU HT Dupont"rile Bond'"Roof Tile Adhesive" FL22525 ICP Adhesives and Sealants"Polyset®AH-160" FL6332 5.7 Allowable Substrates: TABLE 2 SUBSTRATE:OPTtONSFOR"ADFIERED UN©ERLAYMENTS Substrates tclesigned to meet wind loads for'prcii6d) Underlayment Application Type Primer Material{s) Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or Southern Yellow Pine HT-N,RESISTO SA SMOOTH PLY Deck J D41,Elastocol Stick, (SYP) 40,Lastobond Shield HT, sheathing Elastocol Stick Zero Lastobond Pro HT-S, ASTM D41 structural concrete EnviroShieid,Lastobond TU HT, Lastobond Eaves Protection Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum- Sheet,Lastobond 195,Lastobond self- Stick Zero Fiber Roof Board ECO,RESISTO LB1236,Grip-Rite adhering Eave&Valley Protector, TopShield ICE&WATER Base Sheet (Optional)Elastocol ASTM D226,Type 11 felt or Modified Sopra- DEFENDER,RESISTO LB1244, Stick Zero G Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT Deck/ (Optional)ASTM Plywood sheathing ASTM D41 structural concrete Cal hene FR GR self- p adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUftOCK Gypsum- Stick Zero Fiber Roof Board Base Sheet (Optional)Elastocol ASTM D226,Type li felt or Modified Sopra- Stick Zero G RESiSTO LB1236,Grip-Rite Eave self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber surfaced, &Valley Protector orTop5hield adhering substrate PRIMER mineral-surfaced or film-surfaced roof ICE&WATER DEFENDER underlayment *Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite Eave& Valley Protector or TapShield iCE&WATER DEFENDER self-adhering underloyments,contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick,Elastoca1600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSI3 prior to installation of the self-adhering underlayment 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report S18010.06.09-R18 Certificate of Authorization#32455 77H EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 5 of 8 ONEMOletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,but—far mechanically attached base sheets-not less than: ® FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A, Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The fallowing wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-45.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT,self-adhered. #3 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered. Underlayment: Lastobond TU HT,self-adhered. #4 Maximum Design Pressure=-150.0 psf: Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,self-adhered: - — #5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC Evaluation Report S18010.06.09-1118 Certificate of Authorization#32455 7nl EDITION(2-020)FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Undedayments Revision 18:09/17/2020 Page 6 of 8 ONEMOletc. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual,Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSi/SPRI WD3,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Design Pressure=-60.0 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6- inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT,self-adhered 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment attachment shall be in accordance with the manufacturer's installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. 5.9 Exposure Limitations: -TABLE 3 EXPOSURE`LlFnrrATlONS Underlayment Prepared'Roof Cover Maximum Installation Type Exposure(days) Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,Grip- Mechanically 30 Rite Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244 attached Lastobond TU HT Adhesive-set file roof 30 system Lastobond Shield,Lastobond Pro HT-N,RESiSTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically 90 Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT attached Lastobond TU HT or Colphene FR GR Mechanically 180 attached 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE '.Tit£SLIPPAGE LIN1rrATlONS FOR DIRECT DECK 7iLE INSTALLATIONS Uriderlayment `T�le Profile Staging Euiethod7 9 - 9 Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12 followed by 8 tiles high on slope,as shown below) @ Lastobond TU HT tr Lugged NEMO ETC,LLC Evaluation Report S18010.06.09-R18 Certificate of Authorization#31455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 7 of 8 ONEMOletc. TABLE.4:TILE 5LIPPAGE,LIMITATIONS FOR CliRECT-DECRTiL£INSTALLATIONS Underlayment :Tile Profile Staging Method MaxI um'Slope Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.10-tile stack 6:12 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.2.1 Installation of RESISTO LB2236, Grip-Rite Eave &Valley Protector or TopShield ICE & WATER DEFENDER self- adhering underlayment in a reroof(tear-off)application atop an existing underlayment(per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof(tear-off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,Grip-Rite Eave &Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support. 6.3 lastoEit nd TU HT, 4,0band S�Ield,t.asto and Pro HT=1U,RESI,STO SA SMOOTt 1€'LY 40,l astobcirid Stiietd NT, lastaboeid Pro Ii i"-S,"Envk0thietd,Lastobond Eaves Pebte6t o»"Sheet,l.ast6bond"195a last©bond"Ecisibstobcind .Smooth Seal HT;Grlp Rite Sm©othSeal;HT RESISTO LB2236,Grip=Rite Eave&1lalley I?roieitor,TopShield VItATER;DEFENDER,RfSI5TO l81244 ofColphene FR GR: . , 6.3.1 Non-Tile Applications: _. Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D2970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3.2 Tile Applications: Limited to Lastobond TU HT or Colphene FR GR. Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. Refer to7.8.2 for attachment limitations. Refer,to Table 4 for the staging("imitations. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 518010.06.09-1118 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R20 Soprema Roof Underlayments Revision 18:09/17/2020 Page 8 of 8