HomeMy WebLinkAboutGround Sign Foundation and Pole Size Calculationr 5'-0 " 4'-0 " BASIC WIND SPEED = 140 MPH IMPORTANCE FACTOR = 0.77 EXPOSURE = B INTERNAL PRESSURE COEFFICIENT = N/A 16-0" COMPONENT AND CLADDING WIND PRESSURE = N/A THIS SIGN CONFORMS TO THE REQUIREMENTS OF FBC 2001, SECTION 3108 NOTE: THIS DRAWING AND ATTACHED CALCULATIONS APPLY ONLY TOTHE SIGN INSTALLED AT THE ADDRESS SHOWN ON SHEET 2. new double sided lighted sign, extruded aluminum cabinet, 3/16" pan formed acrylic face existing sign 14'-6 " existing 8" SCH40 A53grB steel pipe section mod = 16.8 inA3 min req = 16.6 inA3 grade IDA existing 4' x 4' x 6' der 2500 psi concrete embedment' Copy CN FOR 6 -o p�VlS�ON INSpEC�ES ONLY 11.0 MpONENTS INCLU ND DETAILS. ONNE�TIONS A AND .... ------ . C CONt4EC-nON E REAR 11SppNS1B11-STY DST CONTRACTOR' . aF. THE SIGN " HONDA" 231611 sign by GloMaster Sign Co. Inc. John J. Orlando, PE 165 Old Ridge Road Macon, GA 31211 478 784 2226 Florida registration # 0044089 scale: 1/4" = V 0" sheet 1 of 3 job 1003G y Calculations for GLOMASTER SIGN CO., INC. " HONDA ", job #1003G, 23' 6" OAH ground sign foundation and pole size calculation To be installed at 3806 LIS#1, Ft. Pierce, FL Section 3108 of Florida Building Code 2001 applies: 3108.4.2 Type of sign: ground 3108.5 Type of sign face material: 3/16" pan formed acrylic ASTM D 635 flammability: Jnodcrlics known that meet this requirement (greater than 2 1/2 " per minute) 3108.5.2 Maximum size of individual plastic facing: 75 ft^2 (less than 200 square feet) 3108.3.2 Wind Pressure refers to FBC section 1606 For free standing ground signs, FBC section 1606 refers to ASCE 7-98 to determine wind load. 1. Determine design wind pressure Basic wind speed (3 second gust) from Figure 6-1 b., page 37 1.40 mph Design wind pressure from Table 6-2, page 56 33 psf Exposure category, page 28 B Exposure Factor from table 6-2, page 56 1.0 Importance Classification from Table 1-1., page 4 I Importance factor from Table 6-1, page 55 -0.8 Larger sign dimension (M) 15.00 ft Smaller sign dimension (N) 3.50 ft Sign open (>30% open) or closed closed, M/N 4.3 Force Coefficient Cf from tables 6-11 and 6-12, pages 66 and 67 1-33UII.DING DIVISION INSPECTION FOR Wind pressure (p) adjusted for Cf, exposure factor and importance factor 30AGN C6*PONENTS INCLUDES ONLY 2. Calculate wind load and turning moments VISIBLE CONNECTIONS AND DETAILS. Height Hor Dim Vert Dim Af p F H M (b.46 HIDDEN CONNECTIONS AND z (ft) (ft) (ft) (sf) (Ibs) (ft) ' (ft-IIAILS ARE THE RESPONSIBILITY 0-30 15.0 ' 3.5 52.5 30.5 1601 21.8 3480F THE SIGN CONTRACTOR. y, 0-30 4.0 2.0 .8.0 30.5 244 15.5 3781 0-30 0.7 20.0 13.4 30.5 409 10.0 4086 0-30 0.0 30.5 0 0 Total 73.9 2253 18.9 42685 3. Determine depth of embedment, D in feet - design is based on poor soil with an allowable soil stress (Si) Of 2000 psf, i.e. loose fine and coarse sand n - number of posts= 0 Load per post (P)= 225 -from p. 5-81, Structural Engineering Handbook: D=((1.18*P)/(b*S 1))*(1 +(SQRT(1+(1.88*b*S1 *H/P)))) assume b (ft)= D (ft) = 4.1 sheet 2 of 3 e John J Orlando PE 0044089 , v 165 Old Ridge Road Macon GA 31211� 478 784-2226 " v Caleulations for GLOMASTER SIGN CO., INC. " HONDA ", job #1003G, 23' 6" OAH ground sign foundation and pole size calculation To be installed at 3806 US#1, Ft. Pierce, FL 4. Determine required section modulus (in A3) at base max stress = (P*(H)*12)/section modulus max stress < allowable stress for outdoor signs, allowable stress < (4/3)(0.66)(yield strength) steel grade yield strength -required section > (P*(H)*12)/((4/3)*(0.66*ys)) At base, minimum section modulus = Use an 8" SCH40 A53 grB steel pipe, section modulus = References: Structural Engineering Handbook, Gaylord&Gaylord editors, Fourth edition, McGraw Hill, NY 1997 ASCE 7-98 Florida Building Code 2001 Mechanics of Materials, Beer and Johnston, McGraw Hill, NY 1981 Standard Handbook for Mechanical Engineers, T. Baumeister and L.S. Marks, editors, Seventh edition, McGraw Hill, NY 1967 John J Orlando PE 0044089 r 165 Old Ridge Road Macon GA 31211�� (478) 784-2226 ' A53 grB 35000 psi 16.63 in^3 16.80 in^3 sheet 3 of 3' BUILDING. DIVISION SIGN COM1PONEN INSPECTION FOR VISIBLE CO TS IN NONLY ALL HIDDEN NECTIONS AND DETAILS. DETAILS R CONNECTIONS AND OF THE SIIGNCON RESPONSIBILITY. TRACTOR. 4 It4specTION FOR 'ojt4.G DI'V'S, 1. t4 TS pACL-01DES Ot"'I t4j) J)p-rAws. �Ompov SIGI t4ectiot4s A IS AIRID AL aLF GOIA,v,jj)J)FtA c0t4tAfclOv nirr. IREWO;i�lalvxv S CON Of SIGN CO