HomeMy WebLinkAboutRevised - signed Compaction test Headquarters 1W � � t ENGINEERING Mailing
11345 U.S. Highway 1 PO Box 78-1377
Sebastian, FL. 32958 &J LVL AND TESTING Sebastian, FL. 32978
Orlando Phone: 772-589-0712
723 Progress Way SOIL COMPACTION REPORT C.A.#5693
Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net
DATE REVISED: January 29, 2021
DATE TESTED: February 27, 2020 KSM JOB#: 200965-1d/MH/jo
PERMIT#: 20010523 NUC# 630
CONTRACTOR: Wynne Development Nuc Model: MC-10R-P
JOB LOCATION: 8 Islandia Nuc Serial#: 30630
Spanish Lakes 1
Port St Lucie, Florida
ITEM TESTED: Compacted Foundation Fill
TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT
OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION
1. N.E. 0" - 12" 50 108.6 113.3 95.9%
2. S.E. 50 108.1 95.4%
3. Center 50 109.3 96.5%
4. N.W. 50 108.4 95.7%
5. S.W. 50 109.6 96.7%
Soil Description: 115.0
Brown Sand with traces of w
E I I I I I I
Shell Fragments
In Place Moisture: G 114.0 ••—. I— — I — —I — I — I —
I I I I I
7•9% H I I I I I I
T I
Proctor Optimum Moisture:
113.0 — .-
11.0% P
Proctor Max. Dry Density: P.C.F. C I I I I I I
113.3 112.0 . ---—...
@ Test Locations the Density& I I I I I
Penetrometer readings indicate the 111.0
D i —•1— —'I'— —I'— —"*"—
Degree of Compaction Meets D I I I I I
Minimum Required Y
• I I I I I
for Staked Foundation 110.0
8 9 10 11 12 13 14
Respectfully Submitted:
Digitally
Moisture- % of Dry Weight
signed by
Thisltemhasbeenelectronlcallyslgnedand Bryan E Disclaimer: Contractor is responsible to maintain
sealed by Bryan E.Dahlke,PE FL.Li,.81439
on the date stated direetly to the right wing Dahlke the tested area in the condition that KSM
atu a digital signre.
Printedid.rdMign"hind—ledand re the completed the indicated passed compaction test.
onsit—nnigned and sad an and the Date:
signature must be verified on any electronic
wine,. KSM is not responsible if the tested area has been
14:18:16 1.29 altered from the approved inspected condition.
4:18:
Bryan E. Dahlke, P.E. -05'00'
V.P. of Engineering
PE#81439 1/29/2021
Email to: St Lucie Building Department
Proudly Serving Florida since 1990