Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ��Lz a5 11V 15 d Project Name: Lot 13 Block 5 Waterstone 1480 BGL Builder Name: ADAMS HOM ®� Street: 5349 San Benedetto Place LDEC Permit Office: ��fl City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 cie County, Permitting Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1443.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1207.80 ftz b. Frame - Wood, Adjacent R=13.0 235.83 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (1484.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1484.00 ftz 6. Conditioned floor area above grade (ft2) 1484 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftZ 7. Windows(190.5 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 296.8 a. U-Factor: Dbl, U=0.33 143.22 ftz SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 17.78 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.70 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.30 16.19 ftz SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 13.33 ftz a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.352 ft. Area Weighted Average SHGC: 0.278 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1484.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1484.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.128 Total Proposed Modified Loads: 51.23 PASS Total Baseline Loads: 52.42 1 hereby certify that the plan n cifications covered '""'"" .iew of the plans and S?Ap, this calculation are in corn i with the Flo r rgy specifications covered by this MOUE Code. calculation indicates compliance Florida Energy Code. with the PREPARED BY: Before construction is completed DATE: 11-OR-9O9O Winn Kenmany this building will be inspected for compliance with Section 553.908 t7 _ * ' I hereby certify that this building, as designed, is in compliance the Florida E Cod Florida Statutes. OD with ergy WE OWNER/AGENT. OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). PILE COPY 11/6/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPII')RT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 13 Block 5 Waterstone 14 Bedrooms: 3 User Conditioned Area: 1484 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 13 Block/Subdivision: Waterstone PlatBook: Street: 5349 San Benedetto PI County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1484 13356 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1484 13356 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 150.8 ft 0 1484 ft2 ---- 0.3 0 0.7 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1660 ft2 372 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1484 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1484 ft2 0.11 Wood 11/6/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHFCKI_IST RFPnRT WALLS # Ornt Adjacent Space Cavity Width Height To Wall Type Sheathing Framing Solar Below 1 NE Exterior Concrete Block - Int Insul Main 4.1 37 4 9 0 336.0 ft2 0 0 0.6 0 2 NW Exterior Concrete Block - Int Insul Main 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 44 5 9 0 399.8 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 34 8 9 0 312.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 23 7 10 0 235.8 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 5 in 0 ft 9 in None Exterior 5 2 NW 2 Vinyl Low-E Double Yes 0.3 0.21 N 16.2 ft2 1 ft 5 in 0 ft 9 in None Exterior 5 3 NW 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 5 ft 9 in 0 ft 9 in None None 4 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 5 in 0 ft 9 in None Exterior 5 5 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 It 5 in 0 ft 9 in None Exterior 5 6 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 5 in 0 ft 10 in None None 7 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 5 in 0 ft 9 in None Exterior 5 8 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 5 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 397 ft2 397 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1558.2 85.54 160.88 .1454 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 11/6/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply --- V ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 296.8 ft Main 74.2 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr Ma Jun X Jul Au Se Oct Nov Dec HeatinHJan HFeb Mar APr May Jun Jul rj AuSeP rl rl Oct Nov HX Dec H Ventin Jan Feb X Mar A r Ma Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 11/6/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1484 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.348 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.278 14. Heating system: Capacity 28.2 c) Area 7c. 190.5 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: ` - Date:, Address of New Home: 5349 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951 11/6/2020 4:22:01 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1