HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residen lal� Per-1-6 ethod
Project Name: Lot 12 Block 1 Waterstone 1820 CRGR
11
Builder Name: ADAMS HOME
-
Street: 5412 Lugo Street
Permit Office: ST. Lucie County, Permitting
City, State, Zip: Fort Pierce , FL , 34951
Permit Number.
�_
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2120.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ftz
b. Frame - Wood, Adjacent
R=13.0 270.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1820.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ftz
6. Conditioned floor area above grade (ftz) 1820
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(238.9 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 364
a. U-Factor: Dbl, U=0.33 168.74 ftz
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl', U=0.33 20.00 ftz
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ftz
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.215 ft.
Area Weighted Average SHGC: 0.269
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 64.10
PASS
Total Baseline Loads: 68.84
1 hereby certify that the plans s (cations covered b
-MeftWv of the plans and
ST.g7�
this calculation are in comp' n the Florid rgy
specifications covered by this
O1,TI1E
= > > p
Code.
calculation indicates compliance.
y yip ' _;..��'���WN
with the Florida Energy Code.
rrr,,.t, '��:, :;.';.;;;•�. ��„ O
PREPARED BY:
Before construction is completed
DATE: 11-09-909n Winn Kenmany
this building will be inspected for
compliance with Section 553.908
0
* °i
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
✓ ��
COD
with the Florida Ener
WME
OWNER/AGE-bil" �
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). t C 01 PY
11/9/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 12 Block 1 Waterstone 18 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 12
Block/Subdivision: Waterstone
PlatBook:
Street: 5412 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ftz ---- 0.42 0 0.58
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2052 ft2 460 ftz Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
v #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1835 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ftZ 0.11 Wood
11/9/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Below
Space
1
W
Exterior Concrete Block - Int Insul Main
4.1 59 0 10
0
590.0 ft2
0
0 0.6
0
2
N
Exterior Concrete Block - Int Insul Main
4.1 20 0 10
0
200.0 ft2
0
0 0.6
0
3
E
Exterior Concrete Block - Int Insul Main
4.1 66 0 10
0
660.0 ft2
0
0 0.6
0
4
S
Exterior Concrete Block - Int Insul Main
4.1 40 0 10
0
400.0 ft2
0 0.6
0
_ 5
-
Garage Frame - Wood Main
13 27 0 10
0
270.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Insulated Main
None
.25
3
6 8
20 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
None
2
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
3
N 2 Vinyl Low-E Double Yes
0.33 0.31 N
6.7 ft2
9 ft 0 in
0 ft 6 in
None
None
4
N 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
5
N 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
6
N 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
E 3 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
8
S 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
12 ft 0 in
0 ft 6 in
None
None
9
S 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
None
10
S 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
12 ft 0 in
0 ft 6 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
2123.3 116.57 219.22
.1685
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
11/9/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft'
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinHJan HFeb
Mar
Mar
Apr [
f Apr [
Jul
] May JunJul
] May rl
Jun ri
Aug
AuSep
rj
Se
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan Feb
X Mar
[X] A r [
] Ma Jun Jul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
11/9/2020 9:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1820
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.346
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.269
14. Heating system: Capacity
34.6
c) Area
7c.
238.9
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11 b. c) Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signat►e-.......... Date:
Address of New Home: 5412 Lugo Street City/FL Zip: Fort Pierce, FL 34951
11/9/2020 9:28:07 AM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1