HomeMy WebLinkAboutEngineering PAUL WELCH INC. RECEIVED
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114 JAN 14 2021
Port Saint Lucie, FL 34984 permitting Departmonr
Phone (772) 785 - 9888 St.Lucie count•%,'
JANUARY 14, 2021
Re: Permit#2010-0088
Dobbins Metal Building Foundation
5308 Pine Tree Dr.
Ft. Pierce, Florida
To Whom It May Concern:
Our office has personally inspected the as built 24' x 24' x 8"thick 2500 psi concrete slab
with fibermesh over vapor barrier over clean compacted chemically treated soil and find
that the foundation meets the requirements of the FBC and FRC 2017, 6th Edition, the
requirements of the metal building manufacturer ( SteelMaster Buildings Model#A23-13
DWG# 81-56726 R ) and our engineering requirements. All anchors shall be %" x 4"
minimum embedment redheads located per the metal building plan.
Thank you for your attention to this matter.
Sincerely:
PAUL LCH INC.
W h,Paul P.E.
Fla. Reg. No. 29945
PW:ns
� v
b W&{rdi � SL T