HomeMy WebLinkAboutRevision ilc coriv
OFFICE USE ONLY:
DATE FILED: I PERMIT#-C lv�6f
REVISION FEE: r RECEIPT#
u = PLANNING & DEVELOPMENT SERVICES
'ICOUNTYBUILDING&CODE REG TION DIVISION
23 80 VIRGI
FORT PIERCE,
(772)462-1553 F (7
APPLICATION FOR BUILDING PE N
PROJECT INFORMATION
1. LOCATION/SITE � n /
ADDRESS: �y�o 9D r l!7r d P11 Sin )e
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
ScJOmlwed i.l�nnn ,O�nrArll t �wDD/nrla ��/ lu�.� _ Olnr�/�ecf
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: (;C .l3 0(p.5.3 ST.LUCIE COUNTY CERT.#:
BUSINESS NAME: C
QUALIFIERS NAME: Pion :)7 ly)abanr'li
ADDRESS: /
CITY: STATE: ZIP: i y
PHONE(DAYTIME):. 772- 370-9776 FAX: 77;t 3Y3-i 3571
4. OWNERIBUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE: FAX:
5. ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
Revised mn2/2014
r 4 "s.t C'zs MINr nT,,f IeIVLCION
0 FOR
6
C^� t ''i IiNS AND PFILSUT MUST'RE KEPT CNJ-..
WILL E"
y1 r
Florida Building Code Online Page 1 of 4
File Copy
ProfessionalL d"
Business & • +
BCIS Home Log In User Registration Hot Topic Submit Surcharge Stats&Facts Publications ; FBC Staff BCIS Site Map Links Search
bpr
Product Approval a
USER:Public User
Product Approval Menu>Product or Application Search>ADolication List>Application Detail _
FL# FL14645-R2
Application Type Revision
Code Version 2014 �`m
Application Status Approved
s
Comments "iy b ..� ✓ { .4 v .2ra
Archived a: ,b ? •Yt X lqq' �
•,', y fried 4 �
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street,Suite 200
Louisville, KY 40202
(812)218-7342
dstermer@metaIsales.us.com
Authorized Signature David Stermer
dstermer@metalsales.us.com� " _
ST.Li'CT��� ';7� z� —:^nTI S-10N
Technical Representative RFVTFNN ii 3'UP _ l l:
Address/Phone/Email xr yID",T B
D. E g
Quality Assurance Representative PLAT Is 'D PER IT MUST RE KEPT C JQ-�
Address/Phone/Email OR NO—INSPEC1110N`VILL EZ�yA 1-,r�
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
I Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL14645 R2 COI Certificatelndeoendence.i)df
Referenced Standard and Year(of Standard) Standard Year
FM 4470 1992
TAS 125 2003
UL 1897 1998
UL 1897 2004
UL 580 1994
UL580 2006
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL14645 R2 Eauiv TestEouivalentC2010 UL.odf
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 6/28/2017
Florida Building Code Online • Page 2 of 4
Product Approval Method Method 1 Option D
Date Submitted 03/31/2015
Date Validated 04/14/2015
Date Pending FBC Approval 04/18/2015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
14645.1 2.5"Corrugated Min. 26 ga.,21.33"wide coverage through fastened roof
panel over min. 19/32"thick plywood deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 1I EvaluationReoortC2010 1 odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36"o.c. FL14645 R2 AE EvaluationReoortC2010 1.odf
and 86.0 psf at fastener spacing of 12"o.c. Created by Independent Third Party: Yes
14645.2 5V-Crimp Min. 26 ga.,24 wide through fastened roof panel over min.
19/32"thick plywood deck with fasteners through panel Flat.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 2.Ddf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-149.6 Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24" FL14645 R2 AE EvaluationReoortC2010 2.odf
o.c., 131.3 psf at fastener spacing of 18"o.c. and 149.6 psf Created by Independent Third Party: Yes
at fastener spacing of 12"o.c.
14645.3 5V-Crimp Min. 26 ga.,24"wide through fastened roof panel over min.
19/32"thick plywood deck with fasteners through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14645 R2 II EvaluationReportC2010 3.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 36" FL14645 R2 AE Eva luationReoortC2010 3.odf
o.c.,74.8 psf at fastener spacing of 16"o.c.and 196.75 psf Created by Independent Third Party: Yes
at fastener spacing of 8"o.c.
14645.4 5V-Crimp Min. 26 ga.,24"wide through fastened roof panel over min.
15/32"thick plywood deck or 7/16"thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II Eva luationReportC2010 4.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5 Evaluation Reports
Other:Uplift load of 30.0 psf at fastener spacing of 36"o.c. FL14645 R2 AE Eva luationReoortC2010 4.odf
and 172.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes
14645.5 Aluminum Classic Rib Nom.0.032"thick,36"wide, aluminum through fastened
roof panel over min. 15/32"thick plywood deck or 7/16"
thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II Eva IuationReportC2010 5.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-120 Evaluation Reports
Other: Uplift load of 30 psf at fastener spacing of 36"o.c. FL14645 R2 AE EvaluationReoortC2010 5.pdf
and 120 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes
14645.6 Aluminum Vertical Seam Nom.0.032"thick, 16"wide,aluminum standing seam roof
panel over min. 15/32"thick plywood deck or 7/16"thick
OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 6.oddf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 6/28/2017
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`2.5" CORRUGATED PANEL'
FLORIDA BUILDING CODE 5TH EDITION(2014)
FLORIDA PRODUCT APPROVAL
FL 14645.1-R2
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street,Suite 200
Louisville,KY 40202
Telephone: (502) 855-4300
Fax: (502)855-4290
Prepared By:
Bala Sockalingam, Ph.D.,P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa,OK 74106
Telephone: (918)492-5992
FAX: (866)366-1543
This report consists of
P
Evaluation Report(3 Pages including cover)
Installation Details (1 Page)
♦♦♦♦♦,—P'SOCke"t��
,��♦ ��•• IC �s�/2�i
No c�`. y •
•
Report No. C2010-1 = ;
Date: 3.27.150: S Tq
♦♦
sf I11UlN�
S,30 �r
FL 14645.1-R2
C2010-1
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 2.5" Corrugated
Panel Description: 21.33" wide coverage with (10) 1/2" high ribs spaced at approximately
2-5/8" o.c.
Materials: Min. 26 ga., 80 ksi steel or min. 24 ga., 50 ksi steel. Galvanized coated
steel (ASTM A653) or Galvalume coated steel (ASTM A792) or
painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 82.3 psf @ fastener spacing of 36" o.c.
(Factor of Safety=2) 86.0 psf @ fastener spacing of 12" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends and C 5.33" o.c. across panel width(every other valley)
intennediate locations
Sidelap Attachment: 1/4'-14 x 7/8" long SDS with washer @ 18"o.c.
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
FL 14645.1-R2
C2010-1
3.27.15
Page 3 of 3
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T215-05, Reporting Date 11/4/05
2.5" CORRUGATED vo ns. oa
s zs/s
PANEL OVERLAP— 1/4"-14 X 7/8" TEK SCREW '
SEE DETAIL 1 / SPACED AT 18" O.C. 5.33- (TYP)
MINIMUM ATTACHMENT: \� PANEL FASTENER PER ALLOWABLE
! Bd x 2.5" LONG RING SHANK NAIL PRESSURE TABLE ON THIS SHEET.
t OR /8 x 2" LONG WOOD SCREWS
SPACED O 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
PLYWOOD UNDERLAYMENT SHALL BE INSTALLED MIN. 2X_ WOOD RAFTER/JOIST/ o
•
19/32" THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION TRUSS AT MAX. 24' O.C. o
GUIDELINES N
TYPICAL PANEL INSTALLATION X—SECTION wo
008
ALLOWABLE UPUFf PRESSURE V) cc vI
1/4"-14 X 7/8"TEK SCREW FASTENER PRESSURE co
SPACED AT 18" O.C. SPACING (PSF) cl I
(IN) 1/ d o
/9-16 OR J10-14 WOODSCREWS
WITH SELF SEALING WASHER AT 35 82.3 u�io
MAXIMUM SPACING OF 36" O.C. 5 ,q
-MIN"26 GA.CORRUGATED 12 86.0 d tj 2 n
a '
W
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC). g
2. ALL ROOF PANELS ARE SHALL BE 26 GA (t = 0.0162"). EFFECTIVE COVERING p
J N WIDTH OF PANEL = 21.66".
( 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
UNDERLAYMENT--J PLYWOOD SPECIFIED ON THIS DRAWING, 1 1
19/32" THICK (MIN.) 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS ry3a •
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING, a
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA -
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM q b
DETAIL 1 REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND W94D LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
51i.
NO.
1 �