Loading...
HomeMy WebLinkAboutBuilding plans3' x 3' x 0.00' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) WITH (3) - 012 x %' S.M.S, EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE 6 C-C FASTENER SPACING) 3' x 2' x 0,050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) (3) - Al2 x %. S.N.S. EACH SIDE AS SHOWN 0 STANCEP6ACECE➢GE FASTENER SPACING) FOUNDATION MST '�, HEAVE RAIL CORNER POST V x 2' SOLE PLATE CONCRETE ANCHOR (2 PLACES) U OF TYP. Yi 0 CONCRETE S FOR CORNER COLUMN (11 TOTAL) - 6' x 5' x 0.050' 6063-T6 ALLOY PLATE (ONE SO)E) OR STRONGER K-BRACE — 2x3xO.07O CHAIR MAIL K-BRACE -[K-CsE PL AW AND ALL PROPOSED WORUTERAL "ICE - BRACING ARE JNRJEDT TO ANY CORRECTIONS ::CONNECTION DETAILS REQUIRED BY FIELD INSPECTORS THAT. Y. ngy.ZWfl3 % l %` PLIGAMLI CODE& (5) A120/4" S.M.S. Ix2 O.B. ATTACHED TO BEAM W/ (2)-BOX2' B.M.B. INTO SCREW BOSS (1)-1/S. iHRUBOLT W/ NUT S.Ys' NUT AND WASHER O EACH SIDE OF BFAIA p12X2" S.M.S. O 24" O.C. lx2 O.B. TO SUPER GUTTER (4) g12N3/4' S.M.S. ROOF BEAM (RAT OR SLOPED) --� (2 FOR 2x8 (4) #12x3/4" S.M.B.- EACH LEG. 5' 0, 7' SUPER OTTER MIN. 0.090' THICK Y ANGLE 6' LONG B EACH BEAM) YlWx3' LG B EACH ANGLE FACIA TO BE 2x6 (MIND S.P.F. NOTED OR WESTER RED CEDAR STRUCTURAL GRA➢E 2 MIN (D Y!'0x2' LG LAG SCREW 2 2Y DC,ENTIRE LENGTH OF GUTTER SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Ifi'0X4' LONG PAN READ LAG SCREWS BEFORE ATTACHING SUPER GUTTER (1) %'0x2' LG. LAG SCREWS (❑ 7 1 TYP. 2 EACH BEAM) R / (1) NI2x2' S.M.S B 12' o.c. (MAX) BETWEEN BEAMS gNGLEICK CONTINUOUS ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL 01 2' D.C.S.M.S. ADHESIVE UOUS HEAD OF CONSTRUCTION OK)NOVALE,O 59TENERS 0R ATTACNMFPT —COLUMN REi IRESPONSIBILITY TNA TOR OF? Fo GYP 7 , 10 I BEAM STITCHING SCREWS (SEE TABLE) R 24' D.C. \S^ /— SPLICE PLATE (EACH SIDE OF BEAM) LAB / 505R4132 ALLOY OR EQUAL, 1/8' THICKNESS V(CHAIRRAIL) B uNE («««« BEAM 2x4 2x5 2x6 2x7 2x8 2x9 1r%L1_01A5( ` ROOF BEAM zx9aw) 6 S T, L,' IC t NT T'v RI.TFmq".? nTvISIO-, CONNECTION DETAIL 2xIO 1 7 T4V'.dTri9d 1) sP1Z hLG PAUY`)T IA-T D TsA • SEE ELEVATMNS bT V _ FOR 'K' BRACE SIZE ) A)(, v ) q i (' / h T ?' 11,A�NS r )) 3 :CR i x MUST RL dA �T CF $D.. (3) 11241' S.M.S., EACH LEG AND 0A;_ NU "N� np,C xT " �iYU.L 1 Ii,:6ra r.Me B SCRm" B.M.S. CHANNEL TO BEAM 9 C2EW TOTAL 2x3xO.070 ''�•(-NIT- PURUN IN1BY 2" LONG ANGLE,LE, EACH SLOE (TYP.) �2x34.070 GIRT/CHAIR TEAL MIN. (41 Ox2" LOW S.M.B INN SCREW BOSSES (4) #14xtj" S.M.B.. 2 SCREWS (TYP. ALTERNATIVE) EACH LEG (TYP.) B.M.B. POST HOLLOW POST BEI CHAIR RAIL / GIRT TO POST CONNECTION DETAIL 2x PURUN (MAY BE SLOPED (2) /IOx4" S.M.S. THRU. 2x3 OR FLAT) FAVE RAIL INm PURUN SCREW BOSSES USE 010x1 S.M.S. O 24, O.C. TO CONNE "TO 1x2 O.B. TO 2x3 r 1x2 O.B. FASTENED TO COLUMN( W/(2) ®1Ox1)f' S.M.S. INTO SCREW W (EACH ENO, PURUN FASTENED TO COLUMN/POST `, WITH (4) (I12x1" S.M.S. (EACH LEG) USING THICK FLAT BAR BENT TO FIT6063-T6 ALLOY) `COLUMN/POST SIDEWALL POST / COLUMN TO PURLIN CONNECTION DETAIL 200.045 EPVERAIL ATTACHED TO BEAMS WITH (3)-i10x2" S.M.S. I= SCREW BOW. 2.5..125 ANGLE-2' WIDE (2)-01PRIGM� SENA R IWO USE y10N1)¢" S.M.S. O 24' O.C. -- TO CONNECT TO lx2 O.B. TO 20. (9) (I120 S.M.S. EACH SIDE. OF BEAM (TYP.) OR ((6) qyy12xY4" S.M.S. EACH SIDE bF tlF/41 FOR 2x5 COLUMN TO 2x5 BEAM 2 24 12, 3 32 14' 3 40 14' 4 56 16' 5 64 16' 6 72 18' 7 BB 18' 7 96 18' MIN. (4) jl Ox3" LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) BEAM STITCHING O 2C O.C. M. TOP AND BOTTOM OF SMS SEE TASLE FOR SIZES) PURLIN TO ROOF BEAM CONNECTION DETAIL IXIW BY 3" LONG ANGLE, EACH SIDE (TYP.) (LEG (6) TOTAL (") N S.M.B. SEAM MAY BE SLOPED OR FIAT (SEE PLAN FOR SIZE) M' MIN., 3 16' MAX. C-C ACING OF FASTENERS (TYP.) ' MIN. BEAM EDGE DISTANCE (TYP.) MAIN POST / COLUMN TO ROOF BEAM CONNECTION DETAIL DO KIM & ASSOCIATES, !_C CONSULTING STRUCTURAL ENGINEERS PO BOX 1OD39 Tampa, FL 33679 Tel: (813) 374D321 ISSUED C � W U cf) C 0 Z W z W c Z w a O H J Z U U W to a U 0 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIMaASS LLC 39 679 Drawing No. - 060811 SHEET 1OF3 n PURUN SUPPORT COLUMN/POST 24x1/8" x 2" LG. MIGLE W/ (4) /12x3/4" S.M.S (EACH SIDE) %-0 CONCRETE ANCHOR W/2%' EMBEDMENT IWO STRUCTURAL CONCRETE (EACH SIDE) S.M.S. WITH MIN. EDGE DISTANCE )A" ANGLE, EACH SIDE (TIP.) SOLE PLATE 2"x PURUN ;d . Tx2x>6" ANGLE CUP. CW AT ... e ^ A 45' (+/-) ANGLE AND BEAM MAY ATTACHED TO THE SCREEN ROOF 3° MIN. (TYPJ i,ie }Aj Ox2Y" CONCRETE BE FIAT BEAM WITH ONE (1) Yi • TNRU- $CREW ANCHOR O 24" O.C. OR SLOPED ^ BOLT• EDWITiEBEAMOER WASHER. gZ� 1 1 ATTACHED TO BEAM OR SAVE RML. 4sD a' FROM POST (rm.) l j� DIACONAL BRACING SHALL NOT BE +S MIO ATTACHED TO ROOF PURUNS. 2x2x0.093 BRACE SIDEWALL COLUMN TO CONCRETE 9• COLUMN/POS _ / (SEE PUN) CONNECTION DETAIL xz Ds. SOLE PLATE �(w\ PLAN - TYPICAL DIA60NAL ROOF O -2 i i BRACE CONNECTION SEE PLAN FOR SIZE 14 O.S. FASTENED TO CORNS SECTION WITH /14x1M' S.M.S.I 24' D.G. 2x2r%" ANGLE 2" LONG (EACH W/(2) 11NAM' S.M.S. TO POS & 3 8 0 H.D. CALV. D(P. SOL W/ 2 1/2" MIN. EMBEDMENT S.M.S. WITH MIN. EDGE DISTANCE T— > CORNER POST/COLUMN TO CONCRETE CONNECTION DETAIL 9• EDGE OF CONCRETE )§" MGM EACH SIDE (M.) %'0 CONCRETE ANCHOR W/2)6' EMBEDMENT INTO STRUCTURAL CONCRETE OW., SEE NOTE 10) �1'4" O.B. SOLE PLATE s 3' MIN. (TYP.) =�HOR O.C. AND 9' MOM POST (T(P.) Ix2 O.B. SOLE PLATE 1 (TYPJ NZ PAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL PLAN VIEW BEAM SUPPORT COLUMN/POST 2.2018" x 2' LG. ANGLE W/ (4) /12x3/4' S.M.S (EACH SIDE) I' COLUMN THICK BRICK PAVERS 19BTBH ON TOP OF FOOTER O.B. SOLE PLATE Z i 1 x0 Yi 0xS' CONCRETE SCREWS (MI O.C. 2iS'�MIA ) 1)4° CONC. EMBEDMENTT (MIN.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SLAB (2500 PSI, MIN.) W/6x6x1O/10 W.W.M. OR FIBER REINFORCED [POLYPROPYLENE FIBER - 1.5 POUND (MIN.)PER C.Y.) •d.. •v. A4 .ne 'a , 4 — ' e d e d ° e a e. �CNOSHED ( ED SOIL OCOMPACTED • CRUSHED UMEROCK 90% PROCTOR) MIN. (1)-/5 SEW CONTINUOUS, SPUCE MUST OVERLAP 20" MIN. J" COVER (TYP.) ix3 O.B. FASTENED TO CORNER SECTION WITH /10x2' S.M.S. W/ %' CIA. WASHER O W D.C. (a' of THE 1-1x2 O.B. TOP FRAME CORNER POST -1x O.B. SIDE WALL CORNER UPROW CORNER POST/COLUMN UPRIGHT DETAIL File cod. POST DO K I M & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33879 Tel: (813) 3740321 IZ ?*'I ISSUED I 2500 PSI MIN. CONCRETE STRENGTH dR d APPROXIMATE •', .• 1 GRADE I a d _ • d a O) a J da' COMPACTED OR _ d UNDISTURBED SOIL/SAND LLI t) (1)-g5 REBAR, CONTINUOUS C W ' 3" MIN. CONIC. COVER, 36" MIN. _'aT1TSTL�' LAP SPLICE U OJ Qc1 U 12" MIN! Z U N W MIN. CONTINUOUS PERIMETER FOOTING d w (BY OTHERS) LU a 0 y 1- J W Cor; as} 9UM ALTERNATE (1) �A (.) 0 I•- (4) /12x%' 2'x PURUN BUM MAY BE MT OR SLOPED PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 ANGLE E x15" ANGLE (BRACE) W/ '.12x)'4' S.M.S. O EACH ER INTERSECTION 1" ANGLE 2' LONG ON RSIDEW/(4) Al2x%4" S.M.S. LED (BEAM & BRACE) I SCALE: ASSHOWN 1 DO YEON KIM, P.E. 2x3 BRACE FLA. REG. NUMBER 49497 (SEE PLAN) ALTERNATE (2) DO KI &.. SOCIATES, LLC 2x3 BRACE - - C 87 PO Box 1r Tampa,, FL 33879 Drawing No. - 060811 SHEET 2OF3 FOUNDATION/SLAB DETAIL Genera! Notes and Specifications. 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28', day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with All 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Wall screen shall be removed in accordance with Rule 61620-1.002 Alternative Design for Screen Enclosures. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy, or 6063-T6 Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edoe distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling ITEM Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 5/,6 Y2" #12 0.219 3/8, #14 (1/4") 0.250 1/2 5/B' 9, Structure has been designed to meet the 511 Edition FBC (2014 FBC). Project is sited where the ultimate design wind speed, V-1t, is 150 mph (3-sec gust) for risk category I buildings and other structures, Exposure B. Design pressures are from Table 2002.4, 2014 FBC reduced by 0.88 for screen mesh factor, 0,6 for allowable stress design (ASD). 10. Concrete anchors may be "Large Diameter Tapcons" (LTOs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. IDO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS I Po Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED H w cLu Lu Of o U to c 0 U Lu N W c Z � ag In = J WLu a U 0 DO YEON KIM, P.E. ` FLA. REG. N BER 49497 DO KIM S8 CIATES, LLC 6887 P B T. pa, FL 33679 - q. -t /7 I Drawing No. - 060811 I SHEET 3OF3