HomeMy WebLinkAboutEngineering i PAUL WELCH INC. RECEIVED Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 JAB 1 4 2021 Port Saint Lucie, FL 34984 permitting Deparemnnr Phone (772) 785 - 9888 St. Lucie count•, II JANUARY 14, 2021 Re: Permit#2010-0088 Dobbins Metal Building Foundation 5308 Pine Tree Dr. Ft. Pierce, Florida i To Whom It May Concern: Our office has personally inspected the as built 24' x 24' x 8" thick 2500 psi concrete slab with fibermesh over vapor barrier over clean compacted chemically treated soil and find that the foundation meets the requirements of the FBC and FRC 2017, 61h Edition, the requirements of the metal building manufacturer (SteelMaster Buildings Model#A23-13 DWG# 81-56726 R ) and our engineering requirements. All anchors shall be %" x 4" minimum embedment redheads located per the metal building plan. Thank you for your attention to this matter. Sincerely: PAUL LCH INC. Paul W h, P.E. Fla. Reg. No. 29945 PW:ns F I vk& j