HomeMy WebLinkAboutProduct Approval (3) ivx x%ALL",wiuiug�,vu�v11i1i1C /,�L't U✓ - Page I of 3
„-
������
Ronda Departmeriff BCIS Home I Log In i User Registration i Hot Topics Submit Surcharge ; Stats&Facts i Publications FBC Staff ! BCIS Site Map f Links Search
Businesiz,,,
r�al j= I product Approval
Professib rgc�
USER:Public User
Regulation '
Product Aooroval Menu>Product or Aoolicalion Search>Aoolication List>Application Detall
RiG }h FL# FL15353-R2 MAR 1.�t If
ULM P. Application Type Revision IT TiNG
Code Version 2014 5t• LUCie COL Tr
FL
Application Status Approved
Comments
Archived
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz,PA 17030
(717)365-3300 Ext 2560 1
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com \4
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Mullions
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
!i Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Luis R Lomas,PE
the Evaluation Report
Florida License PE-62514
Quality Assurance Entity National Accreditation&Management Institute
Quality Assurance Contract Expiration Date 12/31/2015
Validated By Steven M.Urich,PE
i✓i Validation Checklist-Hardcopy Received
Certificate of Independence FL15353 R2 COI FLCOI.odf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
FILE
Sections from the Code COPY
1710.5.3
Product Approval Method Method 2 Option B
littps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI... 9/17/2015
rionaa tiuuwng Uode unime Page 2 of 3
Date Submitted 06/15/2015
Date Validated 06/15/2015
Date Pending FBC Approval 06/21/2015
Date Approved 08/19/2015
Summary of Products
FL# Model,Number or Name Description
15353.1 5764 Horizontal Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 IL 08 01448A.odf
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512072A.odf
span:52-1/8". Created by Independent Third Party:Yes
15353.2 5764 Vertical Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 II 08-01439A.odf
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512063A.0df
span:83" Created by Independent Third Party:Yes
15353.3 5765 Horizontal Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 II 08-01449A.13dr
Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size: 52-1/8"x W.Max mullion FLIS353 R2 AE 512073A.odf
span: 104-1/4" Created by Independent Third Party:Yes
15353.4 5765 Vertical Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No 1`115353 R2 II 08-01440A.odf
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512064A.adf
span:83". Created by Independent Third Party:Yes
15353.5 CM-18514 Vertical Aluminum Mullion
_ Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 II 08-01442A.odf
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size: 52-1/8"x 84".Max mullion FL15353 R2 AE 512066A.odf
j length-83". Created by Independent Third Party:Yes
15353.E CM-18520 Horizontal Aluminum Mullion
Limits of Use Installation instructions
Approved for use in HVHZ:No FL15353 R2 11 08-01451A.odF
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size-52-1/8"x 84".Max mullion FL15353 R2 AE 512075A.odf
span-104-1/4" Created by Independent Third Party:Yes
15353.7 CM-18523 Horizontal Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 II 08-01452A.odf
Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Max single window size-52-1/8"x 84".Max mullion FL15353 R2 AE 512076A.odf
span-104-1/4". Created by Independent Third Party:Yes
15353.8 CM-18531 Vertical Aluminum Mullion
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL15353 R2 II 08-01443A.odf
Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514
�https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI... 9/17/2015
REVISIONS
REV DESCRIPTION DATE 9ED
NOTES: A REVISED INSTALLATION DETAILS 06/10/15 R.L.
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY ANCHORING NOTES:
TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM
3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS
DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION SHEET 3.
FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH
4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT
PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS
5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN.THIS SHOWN IN INSTALLATION DETAILS SHEET 4.
DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED 3) ALL FASTENERS TO BE CORROSION RESISTANT.
UNDER SEPARATE APPROVAL.
6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE 4) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH
SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND
WINDOWS AND DOORS, INC. ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS
7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
WINDOW OR DOOR UNIT. B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N,
8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE TYPE 1 (OR GREATER).
UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS 5) TO ATTACH MULLION TO CLIP USE 4
ANCHORED AS SHOWN HEREIN. DRILLING SCREWS PER CLIP. SCREWS)MUST BE FIELD INSTALLED.
4" SELF
9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED HOLES FOR SCREWS ARE NOT PRE—DRILLED BY MANUFACTURER.
IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED
HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING
TO THIS DOCUMENT.
DESIGN PRESSURE TABLE INSTRUCTIONS: '
1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE
CHAPTER 16.
2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON
PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH.
3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT
THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION
SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING
FOR PRODUCT IN STEP 2.
MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED
DESIGN PRESSURE OBTAINED IN STEP 1.
TRIBUTARY WIDTH = W1 + W2
2 SIGNED:0611112015
M650 IWDOWESTMARKED STREET DOORS `���g Ft II Co,�ii��i
GRATZ, PA 17030-0370 v•v\OEb6'F9cp��=
TABLE OF CONTENTS 5764 — VERTICAL MULLION _zt• o�,Sj261 A
SHEET NO. DESCRIPTION 83" MULLION SPAN �� TAT OF �1
1 NOTES GENERAL NOTES 6 W
2 CONFIGURATIONS AND DP CHART V.L.N Dwc No. OB-01439 RA i�•S`OR`'D�`�N
.0 • G
3 INSTALLATION DETAILS SCALE NTS DATE 01/11/12 SHEET OF 3 //77j,/1IIIAII10�\\