Loading...
HomeMy WebLinkAboutProduct Approval (3) ivx x%ALL",wiuiug�,vu�v11i1i1C /,�L't U✓ - Page I of 3 „- ������ Ronda Departmeriff BCIS Home I Log In i User Registration i Hot Topics Submit Surcharge ; Stats&Facts i Publications FBC Staff ! BCIS Site Map f Links Search Businesiz,,, r�al j= I product Approval Professib rgc� USER:Public User Regulation ' Product Aooroval Menu>Product or Aoolicalion Search>Aoolication List>Application Detall RiG }h FL# FL15353-R2 MAR 1.�t If ULM P. Application Type Revision IT TiNG Code Version 2014 5t• LUCie COL Tr FL Application Status Approved Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext 2560 1 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com \4 Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer !i Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Luis R Lomas,PE the Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation&Management Institute Quality Assurance Contract Expiration Date 12/31/2015 Validated By Steven M.Urich,PE i✓i Validation Checklist-Hardcopy Received Certificate of Independence FL15353 R2 COI FLCOI.odf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By FILE Sections from the Code COPY 1710.5.3 Product Approval Method Method 2 Option B littps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI... 9/17/2015 rionaa tiuuwng Uode unime Page 2 of 3 Date Submitted 06/15/2015 Date Validated 06/15/2015 Date Pending FBC Approval 06/21/2015 Date Approved 08/19/2015 Summary of Products FL# Model,Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 IL 08 01448A.odf Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512072A.odf span:52-1/8". Created by Independent Third Party:Yes 15353.2 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01439A.odf Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512063A.0df span:83" Created by Independent Third Party:Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01449A.13dr Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size: 52-1/8"x W.Max mullion FLIS353 R2 AE 512073A.odf span: 104-1/4" Created by Independent Third Party:Yes 15353.4 5765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No 1`115353 R2 II 08-01440A.odf Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size:52-1/8"x 84".Max mullion FL15353 R2 AE 512064A.adf span:83". Created by Independent Third Party:Yes 15353.5 CM-18514 Vertical Aluminum Mullion _ Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01442A.odf Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size: 52-1/8"x 84".Max mullion FL15353 R2 AE 512066A.odf j length-83". Created by Independent Third Party:Yes 15353.E CM-18520 Horizontal Aluminum Mullion Limits of Use Installation instructions Approved for use in HVHZ:No FL15353 R2 11 08-01451A.odF Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size-52-1/8"x 84".Max mullion FL15353 R2 AE 512075A.odf span-104-1/4" Created by Independent Third Party:Yes 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01452A.odf Approved for use outside HVHZ:Yes Verified By:Luis R Lomas,PE PE-62514 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Max single window size-52-1/8"x 84".Max mullion FL15353 R2 AE 512076A.odf span-104-1/4". Created by Independent Third Party:Yes 15353.8 CM-18531 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ:No FL15353 R2 II 08-01443A.odf Approved for use outside HVHZ:Yes Verified By: Luis R Lomas,PE PE-62514 �https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWI... 9/17/2015 REVISIONS REV DESCRIPTION DATE 9ED NOTES: A REVISED INSTALLATION DETAILS 06/10/15 R.L. 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY ANCHORING NOTES: TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION SHEET 3. FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN.THIS SHOWN IN INSTALLATION DETAILS SHEET 4. DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED 3) ALL FASTENERS TO BE CORROSION RESISTANT. UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE 4) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND WINDOWS AND DOORS, INC. ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 WINDOW OR DOOR UNIT. B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE TYPE 1 (OR GREATER). UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS 5) TO ATTACH MULLION TO CLIP USE 4 ANCHORED AS SHOWN HEREIN. DRILLING SCREWS PER CLIP. SCREWS)MUST BE FIELD INSTALLED. 4" SELF 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED HOLES FOR SCREWS ARE NOT PRE—DRILLED BY MANUFACTURER. IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: ' 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W1 + W2 2 SIGNED:0611112015 M650 IWDOWESTMARKED STREET DOORS `���g Ft II Co,�ii��i GRATZ, PA 17030-0370 v•v\OEb6'F9cp��= TABLE OF CONTENTS 5764 — VERTICAL MULLION _zt• o�,Sj261 A SHEET NO. DESCRIPTION 83" MULLION SPAN �� TAT OF �1 1 NOTES GENERAL NOTES 6 W 2 CONFIGURATIONS AND DP CHART V.L.N Dwc No. OB-01439 RA i�•S`OR`'D�`�N .0 • G 3 INSTALLATION DETAILS SCALE NTS DATE 01/11/12 SHEET OF 3 //77j,/1IIIAII10�\\