'FORM R405-2014
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Perform'ance Method
Project Name: JON&SKY.IA SIMON Builder Name: RON RAYM OND CONSTRUCTION INC.
Street: 1404 LONE PINE DR. Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number-
Owner JON&SKYIA SIMON Jurisdiction:
Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(2700.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 2390.00 ft2
1 b.Frame-Wood,Adjacent R=1,1.0 310.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
1
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (2570.0 sqft.) Insulation Area
0. is this a worst case? No
I a.Under Attic(Vented) R=310.0 2570.00 ft2
6. Conditioned floor area above grade(ft2) 257.0 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(309.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 425
a. U-Factor. Dbl,U=0.65 309.00 ft2
SHGC: SHGC=0.25
b. U-Factor. NIA ft2 12.Cooling systems kBfu/hr Efficiency
SHGC: a.Central Unit 66.0 SEER:16.00
C. U-Factor. N/A ft2
SHGC: 13.Heating systems kBt�u/hr Efficiency
d. U-Factor. NIA ft2 a.Electric Strip Heat 27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 4.427 ft-
Area Weighted Average SHGC: 0.250 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (2569.0 sqft.) Insulation Area EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 2569.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.NIA R= ft2 15.Credits CF,Pstat
Total Proposed Modified Loads: 83.68
Glass/Floor Area: 0.120 PASS
Total Baseline Loads: 85.55
I hereby certify that the plans and specifications covered by Review of the plans and 154 E S
this calculation are in compliance with the Florida Energy specifications covered by this 0
Code. calculation indicates compliance u,,
with the Florida Energy Code
. fillr.
PREPED BY: Before construction is completed
DATE: ' -i'S- L this building will be inspected for 0
compliance with Section 553.908
I hereby certify that this b_WWiR9,as designed,is in compliance Florida Statutes.
with he FloridaEne ode. Wf tR
t r
WNERUAGEN BUILDING OFFICIAL:
0 T
DA E. DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with.R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and in envelope leakage
test report in accordance with R402.4.1.2.
-A 3115/2017 5:24 PM EnergyGauge®USA-FIaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
ENERGY RFORMANCE LEVEL (E ��
PE t
DISPLAY CARD 'MAR 201
t TJfYG
ESTIMATED ENERGY PERFORMANCE INDEX* = 98 St. Lucie County; FL
The lower the EnergyPerformance Index,the more efficient the home.
1404 LONE PINE DR., FT. PIERCE, FL,
. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 2390.00 ft2
1 b.Frame-Wood,Adjacent 11=11.0 310.00 ft
3. Number of units,if multiple family 1 c.NIA R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 2570.00 ft2
6. Conditioned floor area(ft2) 2570 b.WA R= ft2
7. Windows" Description Area c.WA R= ft2
a. U-Factor. Dbl,U=0.65 309.00 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Attic 6 425
SHGC: SHGC--0.25
b. U-Factor. NIA ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 56.0 SEER:16.00
SHGC:
d. U-Factor. N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
a.Electric Strip Heat 27.0 COPA.00
Area Weighted Average Overhang Depth: 4.427 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2569.00 ft2 a.Electric EF:0.97
b.N/A R= ft2
c.NIA R= ft2 b. Conservation features
None
15.Credits CF,Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building O�TSE sT,gT�
Construction through the above energy.saving features which will be installed(or exceeded) = e7
ink this home before final inspection. Otherwise;a new EPL Display Card will be completed 43`„ =s 't
based on installed Cod nfea
Builder Signature: Date: 3kll
Address of New Home: f�G , �iw� �t jZ City/FL Zip: 4,a—?)
3 yr8 z WE
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge:corn for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
j staff.
k *'`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/1512017 5:24 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
,i
i
4 �7
Job:
Project Summary wri ghtsoft- P Date:Entire House By:
QUICK CALCS, INC.
3.17 ST LUCIE LN.,FT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
Project Information
For. JON &SKY1A SIMON
1404 LONE PINE DR., FT. PIERCE, FL
P-1
iA
Notes: COPY
Desiqn Information
Weather. Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 190 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 150 %
Moisture difference :61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 27657 Btuh Structure 23220 Btuh
Ducts 9601 Btuh Ducts 16023 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 37258 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 37281 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1
Fireplaces 0 Structure 4262 Btuh
Ducts 4435 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft� 2569 2569 Equipment latent load 8697 Btuh
Volume(ft3) 25690 25690
Air changes/hour 0.32 0.16 Equipment total load 45678 Btuh
Equiv.AVF(cfm) 137 69 Req. total capacity at 0.70 SHR 4.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Trane
Trade Trade TRANE
Model Cond 4TTR6061 B 1
AHRI ref Coil TEM6AOD6OH51++TDR
AHRI ref 7795583
Efficiency 100 EFF Efficiency 12.5 EER, 16 SEER
Heating input 6.1 kW Sensible cooling 39200 Btuh
Heating output 20877 Btuh Latent cooling 16800 Btuh
Temperature rise 50 OF Total cooling 56000 Btuh
Actual air flow 380 cfm Actual air flow 1867 cfm
Air flow factor 0.010 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 1.00 in H2O Static pressure 1.00 in H2O
Space thermostat Load sensible heat ratio 0.82
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2016-Nov-14 10:12:42
wrightsoft, Right-Suite®Universal 2017 17.0.03 RSU081 01 Page 1
...ocurnents\Wrightsoft HVAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
t
wrightsoft, Right-J�Worksheet Job:
• Entire House Date:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House MEDIA ROOM
2 EJ14osed wall 238.9 ft 510 ft
3 Room height 10.0 ft d 10.0 ft heat/cool
4 Room dimensions 1.0 x 314.0 ft
5 Room area 2569.0 ft2 314.0 ftz
Ty Constriction U-value Or HTM Area
Load
r i (ft2) Am (ft�j Load
number (Btuh/ftk-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool
6 13A-4ocs 0143 -n 4bb 255 560 240 410 1642 1044 270 961 611
4A5-26b 0 560 .n 15:68 16)16 -30 0 470 _ 485' 30 0 470 465
4A5-2ob ' 0.560 n 15.68 16.16.' 48 0 753 776 0 0 0 0
4A5-2ob 0.560 n 15.68 16.16 .72 0 1129 1163 0 0 0 0
�11 W 13A-4ocs 0.143 a 4.00 Z55 670 616 2466 1568 120 120 480 305
4A5.2ob 0.560 a 15.68 40.62 9 1 141 366 0 0 0 0
4A5-2ob 0.560 a 15.68 41.95 45 3 706 1888 0 0 0 0
13AAocs 0 143 :s 4.00 Z55 380 278 1113 708 0 0 0 0
4A5=2bb 0 560 .s 15.68' 16.16 30 30 470 485 0 0 0 0
4A5.2ob 0.560 's 15.68 .16.16 30, 30 470 485. 0 - 0 0 0
1100 0.390 S. 10.92 11.31 42 42 459 475 0 0 0 0
VV 13AAocs 0.143 w 4.00 2.55 180 150 601 382 0 0 0 0
t-� 4PS2ob 0.560 w 15.68 41.95 30 2 470 1259 0 0 0 0
i3A-flocs ._ 0.143 ,w 4.00 2.55. 600 564 2260 1436 120. 106 420 267
0D=b 0.690 w 19.32 i 31.26 .21 1 399 646 0 6 0 0
5-2ob 0.560 w. 15.68 41.95 15 1 235 629 15 1 235 629
P 12C-Osw 0.091 2.55 1.28 290 290 739 372 0 0 0 0
C: 161330ad 0.032 0;90; 1-68 2569 2569 2302 4316 314 314 281 528
F 22A-tpl 0.989 27.69 0.00 2569 239 6616 0 314 51 1412 0
3
i
i
I 1
F I
{
,+ 7
3
G
i
I 1
f
I
i
6 c)AED excursion 0 29
Envelope loss/gain 23441 18481 4261 2855
12 a) Infiftration 4216 1129 900 241
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 7 1610 0 i 0
Applianceslother 2000 0
Subtotal Vines 6to 13) 27657 23220 5161 3096
Less a demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 27657 23220 5161 3096
151 Duct loads 35% 69% 9601 16023 35% 69% 1791 2136
Total room Ind 1 37258 39243 6952 5232
Air required(cfm) 380 1867 71 249
Calculations approved bVACCA to meet Calculations approved to meet all requirements of Manual J 8th Ed of Manual J 8th Ed
A%, -Fk wr1ghtsoft- RightSuite®Universal 2017 17.0.03 RSU08101 2016-Nov-14 10:12:42
...ocumentslWrightsoft FNgC\SIMON,JON&SKYIA,rup Calc=MJB Front Door faces: N Pagel
i
- wrightsoft Right-JeWorksheet `� Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL,COM
1 Room name BATH 3 BED 4
2 Erq)osed wall 120 ft 120 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 8.0 x 12.0 ft 15.0 x 12.0 ft
j 5 Room area 96.0 ftz 180.0 ftz
Ty Construction U-value Or HTM Area (ftz Load Area (ftz Load
number (Btuhlft?°F) (BtuhU" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S i Heat Cool
6 1a&4ocs 0143, n':. 4 00 255 '0 0 0 0 0 0 0 0
4A5-26b 0.SW n 15.68` 16.16 0 0. 0 0 0 0 0 0
4A5 lob 0.5W .n 15.68 16.16 0 0 0 0 0 0 0 0
4A5.2ob 0:560 n 15.68 16.16 0 0 0 0 0 6 0 0
11 W 13AAocs 0.143 a 4.00 2.55 0 0 0 0 120 105 420 267
4A5.2ob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5-lob 0.5W a 15.68 41.95 41.95 0 0 0 0 15 1 235 629
.13A-4bcs 0143 s 4:00 Z55 0 0 0 0 0 0 0 0
4AS2ob. 0 560 .s 15:66 16.16 0 0 0 0 0 0 0 0
4A�2ob 0 560 's 15:68 16.16 0 0 . 0 0 0- 0 0 0
11D0, 0.390 s 10.92 1131 0 0 0 0 0 0 0 0
1M 13A-4ocs 0.143 w 4.00 2-55 0 0 0 0 0 0 0 0
t-{; 4A5.2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0
13A 4acs 9.143- w 4.00 255 120 99 398 - 253 0 6 0 0
10D-b 0.690 w 19.32 31.26 21 1 -399 646 0 6 0 0
4A5-2ob 0:560 ;w: 15.68 41.95 0 0 0" 0. 0 0 0 0
P 12C-0sw 0.091 255 1.28 0 0 0 0 0 0 0 0
C 16630ad '0 032 - a90:" 1.68 96 96 86 161. 180 180 161 302
F. 22A-tpi 0.989 - 27.69 0.00 96 12 332 0 180 12 332 0
i
J
r
� r
i
i
y 3
3
I �
}
6 c)AED excursion 227 -28
Envelope loss/gain 1215 1287 1149 1171
12 a) Infiltration 212 57 212 57
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(tines 6 to 13) 1427 1344 1361 1458
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1427 1344 1361 1458
15 Duct loads 35% 690/0 495 927 351/6 69% 472 1006
Total room load 19M 2271 1833 2463
Air required(cfm) 20 108 19 117
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-F44 wrightsoft- 2016-Nov-1410:12:42
Ar iffA Right-Suite®Universal 2017 17.0.03 RSU08101 Page 2
ocuments\Wrightsoft HUAC\SIMON,JON&SKYIA.rup Cale=MJ8 Front Door faces: N
Y
i
Ri ht-J��Worksheet Job:
I wrightsoft' g Date:
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BED 3 BATH 2
14.0 ft 8;0 ft
2 E)posed wall
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 11.0 x 14.0 ft 7.0 x 8.0 ft
5 Room area 154.0 ftz 56.0 ftz I
Ty Construction U-%due Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S ; Heat Cool
6 .. 13Ft4bcs . 0143 .n` 4,00 255.' ,.. 0 .. 0 .- 0 0 . 0 0. 0 _ 0
A5-26b 0 0 0 0 0 0
D:560 n. 15:68 16.16 0 0
4A52di 0;560 'n 15.68 16.16 0 0 0. 0 0 0 0 0
4A54ob' 0.560 n 15.68 16.16. 0 0 0 0 0 0 0 0
11 13A-0ocs 0.143 a 4.00 2.55 140 125 501 318 80 711 284 181
4A5.2ob 0.560 a 15.68 40.62 0 0 0 0 9 1 141 366
4A5-2ob 0.560 a 15.68 41.95 15 1 2.35 629, 0 0 0 0
V. 1*-4ocs:.. _0143 I.s 400 255 0 0 0 0 0 0 0 0
4A5.2ob -0 560 s 15.'68 16.16 0 0 0 0 0 " 0 - 0 0
4A5-2ob 0560 S. 15'68. 1616 0 0 0 0 0 0 0 0
11DO 0390 .s 10.92 11.31 0 0 0 0 0 0 0 0
W 13A•4ocs 0.143 w 4.00 255 0 0 0 0 0 0 0 0
-G 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0
13A flocs 0:143 w 4 00' 255 0 0 0 0 0: q 0 . 0
4A52ob.-`'. Oi56D w; ISi68 ,41:95- 0 0 0. 0 0. 0 0 0
10D b 0.690 w. 1982 31.26 0 0 0• 0 0 0
0 0
P 12C-Qsw 0.091 2.55 1.28 0 0 0 0 0 0 0 0
C. r168-306d 0.632 . 0:90_ 1.68` 154` 154 138 :259 .56 56 ' 50 94
F 22A tpi 0.489 - 27.69 0.00 154 14 388 0 56 8 222 0
i
r
i
6 c)AED excursion -29 -16
Envelope loss/gain 1261 1177 697 624
12 a) infl@ration 247 66 141 38
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal pines 6 to 13) 1508 1473 1 838 662
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 5 8 10 17
14 Subtotal 1513 1482 848 679
15 Duct loads 35% 690/0 525 1022 35% 69°/d 294 469
Total room load 2038 2504 1142 1148
Air required(cfm) 21 1191 4 12 55
I
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsof:- 2016-N6v-14 10:12:42
-LA Right-Suite®Universal 2017 17.0.03 RSU08101 Page 3
...ocuments\Wrightsoft WAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
i
i ,
- wrightsoft Right-Ji Worksheet Job:
Entire House Date:
By: ,
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS AOL.COM
1 Room name BED 2 UTIIJTY
2 E)posed wall 14.0 ft i-0 ft
3 Room height 10.0 ft heat/cool 10.0 ft ! heat/cool
4 Room dimensions 11.0 x 14.0 ft 10.0 z 6.0 ft
5 Room area 154.0 ft' 60.0 ft2 j
Ty Constriction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft'°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) j (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross NIP/S Heat Cool
6 l34=400s 0.143 ;n. 4.00 _ 2.55 0 0 0 0 0 0 0 0
4,W2(Db: 0 560 "n, 15.68 16.16 0 0 0 0 0 0 0 0
4A5-lob• 0.'580 n 15..68 16.16 - 0 0 0 0 0 0 1 0 0
4A5-2ob i0.560 n 15.68 16.16 0 0 .0 0 0 0 0 0
11 W 13A-4ocs 0.143 a 4.00 2.55 140 125 501 318 0 0 0 0
4A5-2ob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5-2ob 0.560 a 15.68 41.95 15 1 235 629 0 0 0 0
W 13A-4ocs 6143 s 4 00 255 0 0 0 0 -0 0 0 0
4A5-lob 0 560 s' 15 66 16.16 .0 0 0 0 0 0 0 0
4A5-lob 0'6§0 's ' 15:68 16.16 0 0 0 0. 0 0 0 0
11D0 0.390- s 10.92 11.31 .0 0 0 0 0 0 0 0
1�V 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
t--G 4A52ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0
1344ocs 0.143 .-w 4.00 255 0 0 0 0 0 0 0 0
10D 0;690 ;w 19.32 31.26 0 0 0 0 0 0 0 0
" 4A5 lob' A.560 w 1&68 41.95 0 .0 0 0 0 0 0 0
P 12C-0sw 0.091 - 2-55 1.28 110 110 280 141 70 70 178 90
C. 16630ad 0.032-. '0.90 1.68 154 154 138 259 60 60 54 101
F 22A4pl 0.989 - 27.69 0.00 154 14 388 0 60 0 0 0
i.
I
i
4
E
i
r
i
i
I
1
;
I
I �
I�
i
i
6 c)AED excursion -37 11
Envelope loss/gain 1542 1310 232 180
12 a) Infiltration 247 66 I 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal Qines 6 to 13) 1789 1607 i 232 180
Less external load 0 0 0 0
Less transfer 0 0 j 0 0
Redistribution 5 8 0 0
14 Subtotal 1793 1615 232 180
15 Duct loads 35% 69% 623 1114 350/6 69% 811 124
Total room load 2416 2729 ; 313 304
Air required(cfm) 25 130 3 14
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i
2016-Nov-14 10:12:42
wrigi�tsoft Right-Suite®Universal 2017 17.0.03 RSUMI01 I Page 4
...ocuments\Wrightsoft WAC\SIMON,JON&SKYIA.rup Calc=MJB Front Door faces: N
v
+ wrightsoft, Right-&*orksheet Date:
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Room9 DEN
2 Exposed wall Oft 14'9 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 6.0 x 6.0, ft 1.0 x 154.5 ft
5 Room area 36.0 ftz 154.5 ft'
Ty Constriction U-value Or HTM Area (ft5 Load Area (ft� Load
number (Btuh/ft2-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) ; (Btuh)
Heat Cod Gross N/P/S Heat cool Gross I WP/S i Heat Cool
6 13A�3ocs' -- 0.143, n "4.00 ` Z55 0 0 0 0 0 0 0 0
4A52ob: 0'560 n 15.68 16.16 0 0 ' 0 0 0 0 0 0
4A5-2ob 0.560: n .15.68 16.16 0 0 0 -0 0 0 0 0
4A5-2ob- 0'560 n 15.68 16-16 0 0 0 0 0 0 0 0
11 W 13A�ocs 0.143 a 4.00 Z55 0 0 0 0 0 0 0 0
4A5-lob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5.2ob 0.560 a 15.68 41.95 0 0 0 0 0 0 0 0
13A ocs.: 0A43 rs 4:00 .:-:255 0. 0 0 0 120 90 360 229
4A5--2oti, ". 0 560 .s . 15.681 16.16 0 0 0 0 0 :p 0 0
4A�2ob ' 0560 s 15.68 16'16 0 0 0 0 30 36 470 485
11D0. 0:390 v 10:92 '11:31 0 0 0 0 0 6 0 0
V}J 13A4ocs 0.143 w 4.00 Z55 0 0 0 0 0 0 0 0
�G 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0
'13A4ocs. 0143 4- 4:00 2.55 0 0 0 0 30 30 120 76
6
10D-b- 0 90 w 19.32 31.26 0 0 0 0 0 6 0 0
. 4A5-lob 0.5600 15.68 41.95 0 0 0. 0 0 6 0 0
P 12C-Osw 0.091 Z55 1.28 0 0 0 0 110 110 280 141
C " 16B30ad.: 0.'032 0.90 .1.68, 36 36 32 60 155 155 138 260
F 22 PI 0.989 27.69 0.00 .36 0 0 0 155 15 413 0
- i
i
I
i
i
l
i
t
i
I j
I i
J
Y ¢
i
i i
i
I
k
1
I
3
6 c)AED excursion -3 j 70
Envelope loss/gain 32 57 1783 1120
12 a) Infiltration 0 0 265 71
b) .Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 32 57 2047 1191
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 32 57 2047 1191rx 15 Dt loads 35% 69% 11 39 35% 69% 711 822
Total room load 43 97 l 2758 2013
Air required(cfm) 0 5 1 1 28 96
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. !.
i 2016-Nov-1410:12:42
RightSuite®Universal 2017 17.0.03 RSU08101 Page 5
...ocurrents\Wdghtsoft HVAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
I _ _
- wrightsoft' Right-Jg�Worksheet Job:
Entire House Date:
my:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name DINING AREA KITCHEN
2 Exposed wall 18.0 ft 1.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft j heat/cool
4 Room dimensions 1.0 x 336.0 ft 1.0 ix 174.0 ft
5 .Room area 336.0 ftz 174.0 ftz
Ty Construction U-value Or HTM Area (ft� Load Area (ft� j Load
number (Btuhlft'--°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) 1 (Btuh)
HLt Cod Gross N/P/S Heat Cool Gross N/P/S Heat I Cool
-
6 13446cs' `. 0.143 - n 4.00 255 0 0 0 0 0 0 0' 0
4A5-2ob 0:560 n. 15.68 . 16.16 0 0 0" 0 0 0 0 0
4A5 lob 0.560 n. 15.68 16.1.E 0 0 0 0 0 0. 0 0
4A5-2ob '0.560 n: 15.68 16.16 0 0 0 0 0 0 0 0
11 W 13A4ocs 0.143 a 4.00 255 0 0 0 0 0 0 0 0
4A5-2ob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5-2ob 0.560 a 15,68 41.95 0 0 0 0 0 0 0 0
INr1:A4 :. 0.143 -s..- 4i00 255 0 0 0 0 0 0 0 ' 0
4A5 2ob.'. 0:560 s 15.`68 16.16 0 0 0 0 0 .0 0 0
`4A5-2ob:' 0,560 s. 156w 16.16 0 0 U 0. 0 0 0 0
11DO 0390 s 10.92 11.31. 0 0` 0 0 0 0 0 0
1kJ 13A 4ocs 0.143 w 4.00 255 180 150 601 382 0 0 0 0
-6 4A5-2ob 0.560 w 15.68 41.95 30 2 470 1259 0 0 0 0
13A flocs,, 0143 w 4.00, 2:55 0 0 0 0 10 10 40 25
10D bw 0 690 w' 19.32 31:26 0 0 0 0 0 0: 0 0
4A5lob` 0:560 W. 15.68 41.95 0. 0" 0 0 0 0 0, 0
P 12C-0sw 0.091 255 1.28 0 0 0 0 0 0 0 0
C 16&30ad. .0.032 '- 0.90 1.68% 336 336 301 564 174 174 156 292
F 22A-tpl 0.989 - 27.69 0.00 336 18 498 0 174 1 28 0
I
f
I
3
i
i
i
I
i
w � I
i
7
l
y
4
d
i
I
I
i
I
i
6 c)AED excursion 467 1 -130
Envelope loss/gain 1871 2671 ! 224 188
12 a) Infiltration 318 85 18 5
b) Room ventilation 0 0 j 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 2000
Subtotal Qines 6 to 13) 2188 3216 I 241 2193
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 5 8 5 8
14 Subtotal 2193 3225 246 2201
15 Duct loads 359/6 691/0 761 2225 35% 699/.' 85 1519
Total room load 2954 5450 331 3720
Air required(cfm) 1 1 30 2591 3 177
i
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Fk n rightsoft- 2016-Nov-14 10:12:42
Right-SuiteO Universal 2017 17.0.03 RSU08101 Page 6
...ocuments\Wdghtsoft WAC\SIMON,JON&SKYIArup Calc=MJ8 Front Door faces: N
wrightsoft Right-6 Worksheet y °b
Entire House Date:
BY:
QUICK CALCS, INC.
i
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name HALL FOYER
2 E)gposed wall 0 ft 8.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft { heat/cool
4 Room dimensions 4.0 x 8.0 ft 8.0 ;x 8.0 ft
5 Room area 32.0 ftz 64.0 ftz {
Ty Constriction U-value Or HTM Area (ftz) Load Area (ftz) j Load
number (Btuhlft2-OF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) j (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S ; Heat I Cool
6 : 13A-4dcs 0:143 .n 4:00; 2.55 0. .. p 0 0. 0 0 0 0
4A5-26b .. 0.560 n 15:68 16.16 :, 0 0. 0' 0 0 0 -0 0
4A5-2ob 0.560 ri' 15.68 '16.16 0 0 0 0 0' 0 0 0
N `4AS2ob 0.560 n 15.68 =16.16 0 0 0 0 0 0 0 0
11 IW 13A-4ocs 0.143 a 4.00 255 0 0 0 0 0 0 0 0
I--ca 4A5.2ob 0.560 a 15.68 40.62 0 0 0 0 0 6 0 0
I--G 4A5-2ob 0.560 a 15.68 41.95 0 0 0 0 0 6 0 0
W 13A-4ocs- 0:143 s:: 4:00 2.55 0 0 0 0 80 38 152 97
4A5 lob 0:560 s 15.68 16.16 0 0 0 p p p. 0. 0
4A52cb 0;5W s 15.68 1616 0' 0 0 0 '0 0 0 0
11 D0 0.390 's 10.92 11:31 0 0 0 0 42 42 459 475
W, 13A-4ocs 0.143 w 4.00 Z55 0 0 0 0 0 0 0 0
-G 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 6 _ 0 0
13A-0ocs 0.143 vr; 4.00 255 0 0' 0 0... 0 0 0." 0
10D-b 0:690 w:> 19:32 31.26 0 0 0_' 0 0- '0 0 0
'4A52ob 6.560 wr' 15:68 41.95 0 0 0 0 0 6, 0` 0
P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0
C 16B-30ad 0 032=-- 0:90 . -.1.68 - 32 32 29 54 64 64 . 57 108
F 22A-tpl 0.989 - 27.69 0.00 32 0 0 0 64 8 222 0
. - 9
i
i P
� 1
I
I
I
I
i
I
{
1
3
1
6 c)AED exoursion -3 40
Envelopelosslgain 29 51 890 639
12 a) Infiltration 0 0 141 38
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 29 51 ; 1031 677
Less ekemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution -29 -51 0 0
14 Subtotal 0 0 ' 1031 677
15 Duct loads 35% 69% 0 0 359/6 67/9,1 358 467
Total room load 0 0 1389 1144
Air required(cfm) 0 0 j 14 54
I
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- 2016-Nov-14 10:12:42
Right-Suite®Universal 2017 17.0.03 RSU08101 Page 7
...ocuments\Wrightsoft HVAC\SIMON,JON&SKYIA.rup Calc=MJB Front Door faces: N
i
a
-wrightsoft° Right,®Worksheet Job:
Date:
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name WIC 2 IWIC
2 Exposed wall O ft 6.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft i heat/cool
4 Room dimensions 7.0 x 6.0 ft 7.0 ix 6.0 ft
5 Room area 42.0 ft' 42.0 W
Ty Constriction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft'--°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft)I (Btuh)
i
Heat Cod Gross N/P/S Heat Cod Gross N/P/S i Heat Cod
6 1.3AAocs 0.143 '..n 4.00 ., .255 O-. 0 0 0 0 0 0 0
ti05-2ob. - 0;560 'n:. 15.68 16.16. 0 0 0 0 _ 0 0 0 0
4A5.2ob 0.560 n 15.68 16.16 0 0 0 0 0 0 0 0
4A5 lob 0.5M n 15-68 '1616 0 0 0 O 0 0 0 0
11 W 13A440cs 0.143 a 4.00 Z55 0 0 0 0 0 b 0 0
4A5-2ob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5-2ob 0.560 a 15.68 41.95 0 0 0 0 0 Q 0 0
13Aflocs..: 0:143 'a 4.bb -'2.55 0 0 0. 0'_ 0 0 0 0
4A5-2ob 0:560 .s'" 16:68 .16.16 0: 0 0 0 0 0 0 0
4A5.26b 0:5W S. 15.66 16.16 '0 0 '0 0 0 0 0 0
11D0 0:390 "s„ 10:92 11.31 0' 0' 0 0 0 0 0 0
W 13A4ocs 0.143 w 4.00 Z55 0 0 0 0 0 0 0 0
r G 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 0 0 0
13AAocs 0.143 .w 4.00 Z55 0 0 0 0 60 60 240 153
10D-b 0.6W w 19.32 31.26 0 0 0 0 0 0 _ 0 0
G. 4A5-lob 0560 ..w 15,68 41.95 0 0 0 0 0 0 0 0
P 12C-Osw 0.091 - Z55 1.28 0 0 0 0 0 0 0 0
C 161330ad- 0:032`. 0.90 1.68 42 42 38 71 42 42 ' 38 71
F 22A tpI 0.989 - 27.69 0.00 42 0 0 0 42 6 166 0
f
i
i
1
1
i
i
n
f
1.
s
1
1
1
6 c)AED excursion -4 j -14
Envelope loss/gain 38 67 444 209
12 a) Infiltration 0 0 j 106 28
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 i 0
Subtotal gins 6 to 13) 38 67 ! 550 2W
Less external load 0 0 0 0
Less transfer 0 0 j 0 0
Redistribution 0 0 0 0
14 Subtotal 38 67 550 238
15 Duct bads 350/6 W/o 131 46 35% 69%1 191 164
7 Total room load 51 113 1 741 402
Air required(cfm) 1 5 ) 8 19
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- 2016-Nov-14 10:12:42
ACC P. Right-Suite®Universal 2017 17.0.03 RSU08101 Page 9
...ocuments\Wdghtsoft FNAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
+�-wrightsoft° Right-J'Worksheet Job:
Entire House Data:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-486-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM
1 Room name MASTER BATH TLT
2 Exposed wall 31.0 ft 3.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft J heat/cool
4 Room dimensions 1.0 x 141.0 ft 7.0 3.0 ft
5 Room area 141.0 ft= 21.0 ft2
Ty Construction U-value Or HTM Area (ftq Load Area (ftj E Load
number (Btuh/ft;°F) (Btuhlft2) ofperimeter (ft) (Btuh) or perimeter (ft) : (Btuh)
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 W. 13A Rocs 0143 :n -4 00 2.55 0 0, 0 -0 0 0 0 0
ILA-�(G 4A`r2o6 0 560 n 15.68 1616 0 0. .0 -0 - 0 0 0 0
4A5 tab 0 560 .:n 15.68 ,.16 16` 0 0 0 0 0 0 '. 0 . 0
4A5 2oti 0.560 n 15.68 16.'16 0 0 0 0
`' 0 0 0 0
11 tW 13A-4ocs 0.143 a 4.00 2.55 70 70 280 178 0 0 0 0
I---r 4A5-2ob 0.560 a 15.68 40.62 0 0 0 0 0 0 0 0
4A5-2ob 0.560 e_ 15.68 41.95 0 0 0 0 0 6 0 0
13A flocs 0.143 s 4:00 255 180, 150 601 38.2 0 6 p 0.
4A5lob 6 566 s 15.68 16.16 30- 30 470 ." 485 0 0 0 0
46S26b 0 560 's 15.68 16.16 0 '0 0 0 0 p 0 p
11D0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 255 0 0 0 0 0 0 0 0
4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 0 6 0 0
13A-400s 0143 w 4;00 2-55 60 60'_ 240 153 30 30 120 76
10D 6 0.690 ,-vv 1932 31.26 0 0 0 . 0 0 . 0 0. 0
4A5-26b' 0.560 w. 15.68 41-95. 0 . 0, 0 0 0 0 0 0
P 12C-0sw. 0.091 - 2-55 1.28 0 0 0 0 0 0 0 0
C.- 16630ad 0.032 0.90 1.68 141 141 . 126 237 21 21 19 35
F 22A-W 0.989 - 27.69 0.00 141 31 858 0 21 8 83 0
i
- j
I {
a
i
a
t
i
t
i
6 c)AED excursion -88 7
Envelopeloss/gain 2576 1346 222 105
12 a) Infiltration 547 146 i 53 14
b) Room ventilation 0 0 j 0 0
13 Internal gains: Occupants @ 230 0 0 0 i 0
Appliances/other p 0
Subtotal Qines 6 to 13} 3123 1493 275 119
Less e)Qemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0
14 Subtotal 3123 1493 275 119
15 Duct loads 35% 69% 1084 1030 35% 69% 95 82
Total room load 4207 2523 j 370 201
Air required(cfm) 4311201j 4 10
I
i Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i
x wright.aft- 2016-Nov-1410:12:42
Right-Suite®Universal 2017 17.0.03 RSU08101 i Page 10
...ocumentsWightsoft HUAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
i
a
i
i
` Job:
- wrightsoft® Duct System Summary Date:
Entire House By:
QUICK CALCS, INC.
311 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCSIAOL.COM
Project I
Information
For. JON &SKYIA SIMON
1404 LONE PINE DR., FT. PIERCE, FL
i
i
Heating Cooling j
External static pressure 1.00 in H2O 1.00 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 1.00 in H2O 1.00 in H2O
Supply/return available pressure 0.500/0.500 in H2O 0.500/0.500 in H2O
Lowest friction rate 1.000 in/100ft 1.000 in/100ft
Actual air flow 380 cfm 1867 cfm
Total effective length(TEL) 215 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (Cfm) (cfm) FR (in) (In) Matl Ln (ft) 1 Ln (ft) Trunk
BATH 2 c 1148 12 55 1.000 4.0 Ox 0 VIFx 23.2 1115.0 st 1
BATH 3 C 2271 20 108 1.000 6.0 Ox 0 VIFx 48.7 i 135.0 st1
BED 2 c 2729 25 130 1.000 7.0 Ox 0 VIFx 22.1 1115.0 st1
BED 3 c 2504 21 119 1.000 7.0 Ox 0 VIFx 44.1 1135.0 st1
BED 4 c 2463 19 117 1.000 7.0 Ox 0 VIFx 41.0 1135.0 st1
1 DEN C 2013 28 96 1.000 6.0 Ox 0 VIFx 30.8 11150 st2
DINING AREA C 2725 15 130 1.000 7.0 Ox0 VIFx 45.6 135.0 st1
DINING AREA-A c 2725 15 130 1.000 7.0 Ox0 VIFx 25.6 1115.0 st1
FOYER C 1144 14 54 1.000 4.0 Ox 0 VIFx 24.5 1115.0 st2
KITCHEN c 3720 3 177 1.000 6.0 Ox 0 VIFx 22.6 1115.0 st1
LIVING ROOM C 3052 34 145 1.000 6.0 Ox 0 VIFx 32.4 ; 115.0 st2
MASTER BATH c 2523 43 120 1.000 6.0 Ox 0 VIFx 43.0 1135.0 st2
MASTER BEDROOM c 1939 23 92 1.000 6.0 Ox 0 VIFx 40.4 `135.0 st2
MASTER BEDROOM-A C 1939 23 92 1.000 6.0 Ox0 VIFx 49.1 '135.0 st2
MEDIA ROOM c 2616 35 124 1.000 8.0 Ox 0 VIFx 58.3 155.0 st3
MEDIA ROOM-A C 2616 35 124 1.000 8.0 Ox 0 VIFx 60.4 4155.0 St3
Room9 C 97 0 5 1.000 4.0 OxO VIFx 30.0 1115.0 st2
TLT c 201 4 10 1.000 4.0 Ox 0 VIFx 44.4 '1 135.0 st2
UTILITY c 304 3 14 1.000 4.0 Ox0 VIFx 5.0 a 95.0
WIC c 402 8 19 1.000 4.0 Ox 0 VIFx 40.8 '135.0 st2
WIG 2 C 113 1 5 1.000 4.0 Ox0 VIFx 41.7 135.0 st2
i
i
i
I
i
i
I
j 2016-Nov-1410:12:44
wri htsoft° 9 i Page 1
9 Ri ht-Suite®Universal 2017 17.0.03 RSU08101
...ocuments\Wrightsoft HVACISIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
A
i 1
1
c
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duet
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
i
j st2 Peak AVF 177 639 1.000 813 12.0 0 x 0 VinIFIX
st3 Peak AVF 71 249 1.000 713 8.0 0 x 0 VinIF{x st1
st1 Peak AVF 200 1214 1.000 869 16.0 0 x 0 VinlFlx
Return I Branch '
0
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) I Matl Trunk
rb1 Ox 0 380 1867 0 0 0 0 Ox 0 VIFx
i
1
i
i
i
i
1
i
I
f
i
i
f
j
1
1
1
I+ 2016-Nov-1410:12:44
-` -F�- wrightsoft' Right-Sufte®Universal 2017 17.0.03 RSU08101 Page 2
)CCK ...ocuments\Wrightsoft WAC\SIMON,JON&SKYIA.rup Calc=MJ8 Front Door faces: N
r j
I
i
i
1
G�
I
i
i
I
® O
i
i I I S
I ( L r
I
x
I
i 6- � O
A o
47
r�
® -
!�Ln-HL'
I
Tu�
i
i
i
i
i
�.��. Sin le Family Residence
9 IY Ron Raymond Construction
a HARM E.80EHN" Lot 8 Lone Pine Dr.Ft.Pierce P.O. Box 12058
Saint Lucie County Fort Pierce, FL. 34979
772-878-1361
Jon&Skyia Simon
i