Loading...
HomeMy WebLinkAboutEngineering I Architectonic Inc. Jzl LSE Copy April 21,zo17 RECEI`;'rD APR 2A 20117 City of Fort Pierce Attn:Roof Permit Plan Review 100 N.US#1 Ft. Pierce,.FL 3.4950 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 15200 Orange Avenue.,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 GA GulfRib Roof Panel NOA#14-0520.01 Code: FBC 2014;Section R 905.10 Wind Speed; 160 MPH; Ultimate Design Wind Speeds Exposure:. B Mean Roof Height: 30'Maximum Pitch: 3/12. Required Design Pressure: Zone1:-3U Zone 2:-53.9 Zone3: -101.4 Maximum Uplift Pressure: Fastener spacing:-159.25 psf @ 12"ox. Fasteners: #9 woodscrews Fong enough to penetrate through sheathing a min..of 3/16"w/sealing washer Underlayment:. ASTM D 226 Type II 30#felt w/12 ga. 1-1/4"annular nails.and tin caps @ 6"&12".o.c. Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6',' o.c,thru out Zone 1,4"o.c. perimeter&6"o.c.field Zone 2,and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances,2014 Florida Building Code,l and the Manufacturer's recommendations. j I Respectfully.,Submitted I Michae Seal. Architectonic Inc: " AR96898 806 Delaware Avenue Tel: 772.460 7751 www.architectonicinc.com j I