HomeMy WebLinkAboutEngineering I
Architectonic Inc.
Jzl LSE Copy
April 21,zo17 RECEI`;'rD APR 2A 20117
City of Fort Pierce
Attn:Roof Permit Plan Review
100 N.US#1
Ft. Pierce,.FL 3.4950
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure
located at 15200 Orange Avenue.,Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply&Manufacturing
Profiles: 26 GA GulfRib Roof Panel NOA#14-0520.01
Code: FBC 2014;Section R 905.10
Wind Speed; 160 MPH; Ultimate Design Wind Speeds
Exposure:. B
Mean Roof Height: 30'Maximum
Pitch: 3/12.
Required Design Pressure: Zone1:-3U Zone 2:-53.9 Zone3: -101.4
Maximum Uplift Pressure: Fastener spacing:-159.25 psf @ 12"ox.
Fasteners: #9 woodscrews Fong enough to penetrate through sheathing a min..of
3/16"w/sealing washer
Underlayment:. ASTM D 226 Type II 30#felt w/12 ga. 1-1/4"annular nails.and tin caps @
6"&12".o.c.
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6','
o.c,thru out Zone 1,4"o.c. perimeter&6"o.c.field Zone 2,and 4"
o.c.thru out Zone3
The above approved,as per Florida Building Code Compliance acceptances,2014 Florida Building Code,l
and the Manufacturer's recommendations. j
I
Respectfully.,Submitted
I
Michae Seal.
Architectonic Inc: "
AR96898
806 Delaware Avenue Tel: 772.460 7751 www.architectonicinc.com
j
I