Loading...
HomeMy WebLinkAboutbuildong plan revisionPRE-ENGINEERED TR SEE. TYP. WALL SEC FOR INSU. SPECS �-- SEE TYP. WALL SEC. SINGLE TOP PLATE Yz" DRYWALL 0 I INTERIOR NON -BEARING 2"x4" STUD WALLS 0 16" O.C. WEATHER METAL OR WOOD STUDS TO BE DETERMINED IN FIELD 2"x4" SOLE PLATE BASE BOARD ANCHORED W/ Y4"x3" MATERIAL, STYLE, TAPCONS 6" FROM CORNER AND FINISH TO & 32" O.C. AFTER THAT. IF BE DETERMINED WOOD SOLE PLATE TO BE IN FIELD P.T. OR SEPARATED BY FLOOR APPROVED MOISTURE COVERING TO BARRIER BE DETERMINED IN FIELD 4 SLAB e. NON —BEARING 3/, ALL PARTITIONS SCALE: 3/a" =1' —0" PRE-ENGINEERED TRUSS? / SEE. FOR TYP. INSU. WALL SEC SPECS �- SEE TYP. WALL SEC. SINGLE TOP PLATE W C x Yz" DRYWALL W 01 lil � o R-11 BATT INSULATION P.T. 2"x4" SOLE PLATE ANCHORED W/ Y4"x3" TPCONS 6" FROM CORNER & 32" O.C. AFTER THAT u e 4 a <. SEE SHEET S2 FOR FOOTER DETAILS ON —BEARING GARAGE SCALE: 3/4"=1'-0 3/22/2017 WALL AND CEILING FINISHING GENERAL NOTES: 1. ALL WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN 200 AND A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450 AS DETERMINED BY ASTM E 84 OR UL 723 TESTING METHODS. REFER TO 2014 FBCR 5TH EDITION 302.9.4 FOR ALTERNATE TESTING METHODS AND CRITERIA 2. ALL INSULATION MATERIALS SHALL HAVE A FLAME SPREADINDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE DEVELOPED INDEX NOT TO EXCEED 450 AS DETERMINED BY ASTME E 84 OR UL 723 3. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C 222, C 475, C514, C 1002, C 1047, C 1177, C 1178, C1278, C 1396, OR C 1658. 3.1. ALL GYPSUM BOARD SHALL BE INSTALLED AS PER 2014 FBCR 5TH EDITION 702.3 3.2. ANY ADHESIVES USED FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557. 4. CERAMIC TOLE SURFACES SHALL BE INSTALLED IN ACCORDANCE WITH ANSI A108.1, A108.4, A108.5, A108.6, A108.11, A118.1, A118.3, A136.1, AND A137.1. SEE TYPICAL WALL SECTION FOR ROOF ASSEMBLY DETAILS SEE TYP. WALL SECTION FOR DETAILS e a SEE. TYR. WALL SEC, SEE TYP. WALL SEC. Yz" DURA-ROC 0 I _o �— CERAMIC TILE STYLE TO BE DETERMINED IN FIELD TUF-R RIGID BOARD INSUL. OVER 1 "x2" FURRING STRIPS 016" O.C. OVER. CERAMIC FLOOF TILE e a A. e a SEE SHEET S2 FOR FOOTER DETAILS WALL SECTION C SHOWER SCALE: 3/4"=1'-0" SEE TYPICAL WALL SECTION FOR ROOF ASSEMBLY DETAILS CONCEALED FASTENER TO BE MIN 8dx1Y4" LONG RINGSHANK GALV. NAIL INTO FURRING STRIPS PLACED 1" FROM TOP OF LAP HARDI PLANK LAP SIDING 1 "x2" P.T. FURRING STRIPS 0 16" O.C. FASTENED TO BLOCK W/ 8d CASE HARD NAILS 6" O.C. n a SEE. TYP WALL SE( SEE TYP. WALL SEC. Yz" DRYWALL I b SEE TYPICAL WALL SECTIONS FOR DETAILS GRADE <; e' d e ae SEE SHEET S2 FOR FOOTER DETAILS TYPICAL WALL SECTION WALL SECTION P GARAGE P LAP SIDING SCALE: 3/4„=1,-0" SCALE: 3/4"=1'-0" ASPHALT SHINGLE ATTACHED AS PER MFG. SPECS OVER (1) LAYER OF 30 LB FELT OVER OVER 1%2" PLYWOOD FASTENED TO PRE-ENGINEERED TRUSSES W/ 8d RINGSHANKS NAILS 0 6" O.C. MTL. DRIP EDGE P.T. 1"x2" 2"x6" FASCIA VENTED STUCCO SOFFIT 2'-0" V THICK D A� �'ppEDTOo N O THESE P1ANS Ao ANY TNAT ARE SU&1EGT HELD wSPECTOR- REQUIRED 8Y Y IN ORDER CODES. MAYBE WSTN ALI. APPLICABLE COMPLY [-7t)?,-�D QlSlp'I CUUN'� DU'14Q , . 'ST.LUCIED FOR C WE v WED BY B gEYT ON JOB DATE L BE E PLANS ANS EC 10� N� MAD ORNO G a R-30 BATT. INSULATION %" CIELING DRYWALL MTL. STRAP SEE STRAP SCHEDULE FOR DETAILS DBL BEAM BLOCK W/ (1) #5 CONT. REBAR IN EA. COURSE W/ CORNER BENDS FILLED W/ 3000 PSI CONC. Y2" DRYWALL 0 I o #5 REBAR W/ 10" BEND IN BEAM IN FILLED CELL W/ 3000 PSI CONC. 0 6'-0" O.C. MAX 3/4" FOIL BACKED INSUL. OVER 1"x2" FURRING STRIPS 0 24" O.C. SEE SHEET S2 FOR FOOTER STEEL DETAILS WOOD BASE BOARD r FLOOR COVERING TO BE l DETERMINED IN FIELD d SEE SHEET S2 FOR FOOTER DETAILS TYPICAL WALL, SECTION SCALE: 3/4"=1'-0" REVISION No. Date By 1 31=017 J.D. 2 7/5/2017 J.D. O U � LoLo M a� C) cc O U t— Ucc �nOn a El- 4-) O ��---iI �-i rr FT-1 I-1-1 U L (D a U- a) c E O rr VJ �U cu cu c .0 U- 0 � vJ 00 C i--i --^ C rrC vJ J V) � x w z Ln W m W z x� U� W pp a) a, 4 r O Fri W J A w a. LL l N A N F W C G° T U W° o O li m J 2,L) W d N N r c6 !L a � a N d d x a w x E. at File Sheet si