HomeMy WebLinkAboutbuildong plan revisionPRE-ENGINEERED TR
SEE. TYP. WALL SEC
FOR INSU. SPECS
�-- SEE TYP. WALL SEC.
SINGLE TOP PLATE
Yz" DRYWALL
0
I
INTERIOR NON -BEARING
2"x4" STUD WALLS 0
16" O.C. WEATHER
METAL OR WOOD STUDS
TO BE DETERMINED IN
FIELD
2"x4" SOLE PLATE
BASE BOARD ANCHORED W/ Y4"x3"
MATERIAL, STYLE, TAPCONS 6" FROM CORNER
AND FINISH TO & 32" O.C. AFTER THAT. IF
BE DETERMINED WOOD SOLE PLATE TO BE
IN FIELD P.T. OR SEPARATED BY
FLOOR APPROVED MOISTURE
COVERING TO BARRIER
BE DETERMINED
IN FIELD
4 SLAB e.
NON —BEARING 3/,
ALL PARTITIONS
SCALE: 3/a" =1' —0"
PRE-ENGINEERED TRUSS?
/
SEE.
FOR
TYP.
INSU.
WALL SEC
SPECS
�- SEE TYP. WALL SEC.
SINGLE TOP PLATE
W
C
x
Yz" DRYWALL
W
01
lil
�
o
R-11 BATT INSULATION
P.T. 2"x4" SOLE PLATE
ANCHORED W/ Y4"x3"
TPCONS 6" FROM CORNER
& 32" O.C. AFTER THAT
u e
4 a <.
SEE SHEET S2 FOR
FOOTER DETAILS
ON —BEARING GARAGE
SCALE: 3/4"=1'-0
3/22/2017
WALL AND CEILING FINISHING GENERAL NOTES:
1. ALL WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX
NOT GREATER THAN 200 AND A SMOKE -DEVELOPED INDEX OF NOT
GREATER THAN 450 AS DETERMINED BY ASTM E 84 OR UL 723 TESTING
METHODS. REFER TO 2014 FBCR 5TH EDITION 302.9.4 FOR ALTERNATE
TESTING METHODS AND CRITERIA
2. ALL INSULATION MATERIALS SHALL HAVE A FLAME SPREADINDEX NOT TO
EXCEED 25 WITH AN ACCOMPANYING SMOKE DEVELOPED INDEX NOT TO
EXCEED 450 AS DETERMINED BY ASTME E 84 OR UL 723
3. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO
ASTM C 222, C 475, C514, C 1002, C 1047, C 1177, C 1178, C1278,
C 1396, OR C 1658.
3.1. ALL GYPSUM BOARD SHALL BE INSTALLED AS PER 2014 FBCR 5TH
EDITION 702.3
3.2. ANY ADHESIVES USED FOR THE INSTALLATION OF GYPSUM BOARD
SHALL CONFORM TO ASTM C 557.
4. CERAMIC TOLE SURFACES SHALL BE INSTALLED IN ACCORDANCE WITH ANSI
A108.1, A108.4, A108.5, A108.6, A108.11, A118.1, A118.3, A136.1, AND
A137.1.
SEE TYPICAL WALL SECTION
FOR ROOF ASSEMBLY DETAILS
SEE TYP. WALL
SECTION FOR
DETAILS
e
a
SEE. TYR.
WALL SEC,
SEE TYP. WALL SEC.
Yz" DURA-ROC
0
I
_o
�— CERAMIC TILE STYLE TO
BE DETERMINED IN FIELD
TUF-R RIGID BOARD
INSUL. OVER 1 "x2"
FURRING STRIPS 016"
O.C. OVER.
CERAMIC FLOOF
TILE
e a A. e
a
SEE SHEET S2 FOR
FOOTER DETAILS
WALL SECTION C SHOWER
SCALE: 3/4"=1'-0"
SEE TYPICAL WALL SECTION
FOR ROOF ASSEMBLY DETAILS
CONCEALED FASTENER
TO BE MIN 8dx1Y4"
LONG RINGSHANK GALV.
NAIL INTO FURRING
STRIPS PLACED 1"
FROM TOP OF LAP
HARDI PLANK LAP
SIDING
1 "x2" P.T. FURRING
STRIPS 0 16" O.C.
FASTENED TO BLOCK
W/ 8d CASE HARD
NAILS 6" O.C.
n
a
SEE. TYP
WALL SE(
SEE TYP. WALL SEC.
Yz" DRYWALL
I
b
SEE TYPICAL WALL
SECTIONS FOR DETAILS
GRADE <;
e' d
e ae
SEE SHEET S2 FOR
FOOTER DETAILS
TYPICAL WALL SECTION
WALL SECTION P GARAGE P LAP SIDING
SCALE: 3/4„=1,-0" SCALE: 3/4"=1'-0"
ASPHALT SHINGLE ATTACHED AS PER MFG. SPECS
OVER (1) LAYER OF 30 LB FELT OVER OVER
1%2" PLYWOOD FASTENED TO PRE-ENGINEERED
TRUSSES W/ 8d RINGSHANKS NAILS 0 6" O.C.
MTL. DRIP
EDGE
P.T. 1"x2" 2"x6"
FASCIA
VENTED
STUCCO SOFFIT
2'-0"
V THICK
D A� �'ppEDTOo N O
THESE P1ANS Ao ANY TNAT
ARE SU&1EGT HELD wSPECTOR-
REQUIRED 8Y Y IN ORDER CODES.
MAYBE WSTN ALI. APPLICABLE
COMPLY
[-7t)?,-�D QlSlp'I
CUUN'� DU'14Q , .
'ST.LUCIED FOR C
WE
v WED BY B gEYT ON JOB
DATE L BE E
PLANS ANS EC 10� N� MAD
ORNO
G
a
R-30 BATT.
INSULATION
%" CIELING DRYWALL
MTL. STRAP SEE STRAP
SCHEDULE FOR DETAILS
DBL BEAM BLOCK W/
(1) #5 CONT. REBAR IN
EA. COURSE W/ CORNER
BENDS FILLED W/ 3000
PSI CONC.
Y2" DRYWALL
0
I
o #5 REBAR W/ 10" BEND
IN BEAM IN FILLED CELL
W/ 3000 PSI CONC. 0
6'-0" O.C. MAX
3/4" FOIL BACKED INSUL.
OVER 1"x2" FURRING
STRIPS 0 24" O.C.
SEE SHEET S2 FOR
FOOTER STEEL DETAILS
WOOD BASE BOARD
r FLOOR COVERING TO BE
l DETERMINED IN FIELD
d SEE SHEET S2 FOR
FOOTER DETAILS
TYPICAL WALL, SECTION
SCALE: 3/4"=1'-0"
REVISION
No. Date By
1 31=017 J.D.
2 7/5/2017 J.D.
O
U
�
LoLo
M
a�
C)
cc
O
U
t—
Ucc
�nOn
a
El-
4-)
O
��---iI
�-i
rr
FT-1
I-1-1
U
L
(D
a
U-
a)
c
E
O
rr
VJ
�U
cu
cu
c
.0
U-
0
�
vJ
00
C
i--i
--^
C
rrC
vJ
J
V)
�
x
w
z
Ln
W
m
W
z
x�
U�
W
pp a)
a, 4 r
O
Fri W
J
A
w a.
LL l
N
A
N
F
W
C
G°
T U
W° o
O li
m J 2,L)
W
d N
N r c6
!L
a
�
a
N
d
d
x
a
w
x
E.
at
File
Sheet
si