HomeMy WebLinkAboutCertificate Design Load File Copy
Planning& Development Services Department
Building&Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553
Certification for Design Load Compliance
Project Name: HIPPS COVERED PORCH
Project Address: 5415 FORT PIERCE BLVD.
Permit#: Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE:
•This certification must be completed,signed,and sealed by the design professional of record.
•Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
*Note:Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply)
1.DESIGN CODE:Florida Building Code 2014 Edition with 20 Supplements using ASCE 7-10
2.Structure Designed as(check one): _Enclosed _Partially Enclosed X Open
3.Risk Category: _I X II III IV Exposure Category: X B C_D
4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft
5.Mean Roof Height: 15 ft Roof Pitch: 4 :12 Parapet: N/A ft
6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 151MRH,clearly label on all plan openings):
16.0 16.0 16.0 23.4 23.4 22.0
Zone 1: _21.1 Zone 2: -39.8 Zone 3: -60.9 Zone 4: -25.8 Zone 5: -32.8 Garage: -29.9
7.Design Loads:Floor: N/A PSF Roof/Dead: 7 PSF Roof/Live: 20 Balcony:_ N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED
B.Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St.Lucie
County.I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
_ Paul Welch P.E. 29945 / 5115
Print Name Cert#&Co.Cert Auth.
Paul Welch Inc.
IJN PLAN __.___ _4/21/2017-
Signature,Date;and Seal 1984 S.W. Biltmore St.Suite#114 Port St. Lucie,FL
^ Company Name&Address
SLCCDV Form#020-12 Revised 3/-15/12(J5)