HomeMy WebLinkAboutRevisions , energy calcs, hvac OFFICE USE ONLY:
DA`I`E-FILED:.:._,.. •3.1.a31 - :. PER1VId I.#.....,i -OZi I Z .
REVISION FEE: -I - RECEIPT
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
=� 3
FORT PIERCE,FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
9301 Portside Drive,Ft Pierce,FL 34945
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
See attached letter
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CGC 1261228 ST.LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME: Glenn Allen Davis II
ADDRESS: 3725 SE Ocean Blvd,Suite 101
CITY: Stuart STATE: FL ZIP: 34996
PHONE(DAYTIME): 772-692-7800 FAX: 772-692-9155
OWNER/BUILDER INFORMATION:
NAME: Renar Homes(Momingside),LLC
ADDRESS:3725 SE Ocean Blvd,Syite 101
CITY: Stuart STATE• . P.
34s9s
PHONE(DAYTIME. ' 2- s '�0 s` o=:Fy
n2-ss2aaoo t AX ,
, Fj
ARCHITECT/ENGINEER INFORMATION:
NAME: Michael Anderson
ADDRESS: 3725 SE Ocean Blvd,Suite 101 sy
CITY: Stuart STATE: FL I -,, • s `'
PHONE(DAYTIME): 772-692-7800 FAX; 772-692-9155
fdo j ;)pA
SLCCC: 9123109
Revised 06/30/171
i
Planning&Development Services
REVIEW COMMENTS
Building B Code Regulation Division
2300 Virginia Avenue
Fort Pierce,FL. 34982
Phone:(772)462.2172 Fax:(772)462.6443
Page 2
REVISIONS INCOMPLETE William Durden 4/3/2018
4/3/2018 Comment: PLEASE SUBMIT REVISED ENERGY CALC'S AND MANUAL J'S FOR THE REVISION.SEE SECTION,107 OF THE
2017 FLORIDA BUILDING CODE.
ZONING REVIEW COMPLETE Lydia Galbraith 5/4/2017 6/16/2017 6/16/2017
Comment:
i
I .
I
I
i
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include: RECEIVE®
This checklist APR P; Q 2018
STt �uGte counx�, Psrrn1Cem9
A Form R405 report that documents that the Proposed Design complies with
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(one page) and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
40I Energy Performance Level(EPL)Display Card(one page)
p' HVAC system sizing and selection based on ACCA Manual S or
per exceptions provided in Section R403.7
p A
0 Mandatory Requirements(five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
p )
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
File COPY
S
411 7/201 8 2:48:36 PM EnergyGauge@-USRCZB v6.0
Page 1 of 1
i
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RENAR HOMES WILSHIRE 1800 Builder Name: RENAR HOMES
Street: 9301 PORTSIDE DRIVE Permit Office: FT PIERCE
City,State,Zip: FT PIERCE,FL, Permit Number:
i
Owner: SPEC HOME Jurisdiction: 661100
Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2067.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1907.30 ftz
b.Frame-Wood,Adjacent R=11.0 160.00 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d. N/A R= ft2
10.Ceiling Types (976.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 976.00 ft2
6. Conditioned floor area above grade(ft2) 1800 b.N/A R= ft2
c.N/A R= ft2
Conditioned floor area below grade(ft2) 0 11.Ducts R ft2
7. Windows(257.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 131
a. U-Factor: Sgl,U=0.54 217.83 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl,U=0.61 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.23
a.Central Unit 40.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 38.5 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.293 ft.
Area Weighted Average SHGC: 0.247 14.Hot water systems
8. Floor Types (1204.0 sqft.) Insulation Area a.Electric Cap:46 gallons
EF:0.920
a.Slab-On-Grade Edge Insulation R=0.0 824.00 ft2 b. Conservation features
b.Floor over Garage R=19.0 380.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.143
Total Proposed Modified Loads: 63.43 PASS
Total Baseline Loads: 67.39
- i
I hereby certify that the plans and specifications covered by Review of the plans and � ' EIST,gI�
this calculation are in compliance with the Florida Energy specifications covered by this _ , p
Code. calculation indicates compliance
with the Florida Energy Code. ti uerr•'P'( =�;t O
PREPARED BY: Before construction is completed c� ?
_ „tits.
_._...-.... 01
DATE: this building will be inspected for I,,
compliance with Section 553.908
I hereby certify that this building,as des' , is in ompliance Florida Statutes. yt
with the Florida Energ Co '. �►'pD �
OWNER/Af NT: BUILDING OFFICIAL:
DATE. ��'11 DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as:
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in i 1 p j ct requires an
envelope leakage test report with envelope leakage no greater than 7.00 AC 0' 02.
FS
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 Section R405.4. Compliant Software Page 1 of 5
i
i
i
FORM R405-2017
PROJECT
Title: RENAR HOMES WILSHIRE 1 Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1800 Lot#
i
Owner Name: SPEC HOME Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: RENAR HOMES Rotate Angle: 270 Street: 9301 PORTSIIDE DRIV
Permit Office: FT PIERCE Cross Ventilation: County: St.Lucie I
Jurisdiction: 661100 Whole House Fan: City,State,Zip: FT PIERCE„
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design! Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Block1 1800 16200
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1800 16200 Yes 8 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 120 ft 0 824 ft2 -- 0 0 1
I
2 Floor over Garage Main - Y- 380 ft2 19 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Flat tile/slate 1057 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 976 ft2 N N
I •
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac TrussiType
1 Under Attic(Vented) Main 30 Blown 976 ft2 0.11 Wood
I
I
i
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software 'Page 2 of 5
I
FORM R406-2017
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
0
_ 1 N=>W Exterior Concrete Block-Int Insul Main 4.1 34 8 8 294.7 ft2 0 0.3 0
_ 2 E=>N Exterior Concrete Block-Int Insul Main 4.1 16 8 8 138.7 ft2 0 �0.3 0
_ 3 S=>E Exterior Concrete Block-Int Insul Main 4.1 14 8 8 .121.3 ft2 0 0.3 0
_4 W=>S Exterior Concrete Block-Int Insul Main 4.1 25 0 8 8 216.7 ft2 0 0.3 0
5 N=>W Garage Frame-Wood Main 11 20 0 8 160.0 ft2 0 0.3 0
6 N=>W Exterior Concrete Block-Int Insul Main 4.1 34 8 0 272.0 ft2 0 0.3 0
- 7 E=>N Exterior Concrete Block-Int Insul Main 4.1 37 8 0 296.0 ft2 0 0.3 0
8 S=>E Exterior Concrete Block-Int Insul Main 4.1 34 8 0 272.0 ft2 0 0.3 0
9 W=>S Exterior Concrete Block-Int Insul Main 4.1 37 8 0 296.0 ft2 0 0.3 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In,
1 S=>E Insulated Main None .46 3 6 8 20 ft2
2 N=>W Wood Main None .46 2 8 6 8 , 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>W 1 Metal Single(Tinted) Yes 0.61 0.23 N 40.0 ft2 1 ft 4 in 1 ft 0 in None None
2 N=>W 1 Metal Single(Tinted) Yes 0.54 0.25 N 22.5 ft2 1 ft 4 in 12 ft 0 in None None
3 N=>W 1 Metal Single(Tinted) Yes 0.54 0.25 N 9.0 ft2 1 ft 4 in 12 ft 0 in None None
4 S=>E 3 Metal Single(Tinted) Yes 0.54 0.25 N 31.5 ft2 1 ft 4 in 12 ft 0 in None None
5 W=>S 4 Metal Single(Tinted) Yes 0.54 0.25 N 15.0 ft2 1 ft 4 in 12 ft 0 in None None
6 N=>W 6 Metal Single(Tinted) Yes 0.54 0.25 N 30.0 ft2 1 ft 4 in 0 ft 6 in None None
7 N=>W 6 Metal Single(Tinted) Yes 0.54 0.25 N 6.0 ft2 1 ft 4 in 0 ft 6 in None None
8 E=>N 7 Metal Single(Tinted) Yes 0.54 0.25 N 15.0 ft2 1 ft 4 in 0 ft 6 in None None
9 S=>E 8 Metal Single(Tinted) Yes 0.54 0.25 N 45.0 ft2 1 ft 4 in 0 ft 6 in None None
10 S=>E 8 Metal Single(Tinted) Yes 0.54 0.25 N 3.3 ft2 1 ft 4 in 0 ft 6 in None None
11 E=>N 2 Metal Single(Tinted) Yes 0.54 0.25 N 18.0 ft2 1 ft 4 in 1 ft 0 in None None
12 W=>S 4 Metal Single(Tinted) Yes 0.54 0.25 N 22.5 ft2 12 ft 4 in 1 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
i 1 380 ft2 380 ft2 64 ft 8 ft 1
I
I
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
i
I
FORM R405-2017
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
i
1 Wholehouse Proposed ACH(50) .0004 1890 103.76 195.13 .3598 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.2 38.5 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ None SEER: 14 40 kBtu/hr 1200 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert #, Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply-- —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 131 ft2 Attic 54 ft2 Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
I
Cooling Jan Feb Mar [ ]Apr May un Jul AugSe Oct Nov Dec
Heating Jan Feb Mar L 1 Apr May roun Jul Aug Sep �C�Occtt �Nov Dec
Venting Jan Feb X Mar lxJ
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
i
I
i
FORM R406-2017
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 .80 80
PM 80 80 78 78 78 78 78 78 78 78 ' 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 .78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit
i
I
II
I
I
i
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 94
The lower the EnergyPerformance Index, the more efficient the home.
9301 PORTSIDE DRIVE, FT PIERCE, .FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1907.30 ftz
b.Frame-Wood,Adjacent R=11.0 160.00 ft
3. Number of units,if multiple family 1 c.NIA R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 976.00 ft=
6. Conditioned floor area(ftz) 1800 b.N/A R= ftz
7. Windows*" Description Area c.N/A R= ftz
a. U-Factor: Sgl,U=0.54 217.83 ftz 11.Ducts R ftz
a.Sup:Attic,Ret:Attic,AH:Garage 6 131
SHGC: SHGC=0.25
b. U-Factor. Sgl,U=0.61 40.00 ftz
SHGC: SHGC=0.23 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 40.0 SEER:14.00
SHGC:
d. U-Factor. N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 38.5 HSPF:8.20
Area Weighted Average Overhang Depth: 2.293 ft.
Area Weighted Average SHGC: 0.247
8. Floor Types Insulation Area 14.Hot water systems
a.Slab-On-Grade Edge Insulation R=0.0 824.00 ftz a.Electric Cap:40 gallons
EF:0.92
b.Floor over Garage R=19.0 380.00 ftz b. Conservation features
c.N/A R= ftz None
15.Credits ' Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ywQ~,'��� ` o0,
�.
based on installed Code compliant features.
Builder Signature: Date:
o a�ya a
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy-Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
I I
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADD RESS: 9301 PORTSIE D DRIVE Permit Number:
FT PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air,
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(0,(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations, renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test,shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems,if installed at the time of the test,shall be turned off.
6. Supply and return registers,if installed at the time of the test,shall be fully open.
R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400'or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5
i
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the'room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential,
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not '
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air.distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the
manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the
entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105"F(41°C)
or below 55"F(1 WC)shall be insulated to a minimum of R-3.
R403.4.1 Protection of'piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. 1
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return
pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
11403.5.1.2-Heat trace systems. Electric heat trace systems shall comply v&h'IEEE 515.1 or UL 515.Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times;when heated water is used in the occupancy.
t
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5
� I
I
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.Extemal heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3• If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment(Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that
affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUIV
(CFM) (CFM/WATT) (CFM)
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
I
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
i
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the j
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is lessthan the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
j
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
I
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capl city on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
I
R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and'an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10A Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a1iquid cover or other means proven to reduce heat loss.
Exception: ' Where more than 70 percent of the energy for heating;computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
I
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5
i
I
i
R403.10.5 Heat m I e pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(MandatoryQhe energy consumption of electric-powered portable spas shall be controlled by the
requirements ofAPSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain,only high-efficacy lamps.
Exception:Low-voltage lighting.
R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights.
i
I
4/17/2018 2:48 PM I EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: RENAR HOMES WILSHIRE 1800 Builder Name: RENAR HOMES
Street: 9301 PORTSIDE DRIVE Permit Office: FT PIERCE
City,State,Zip: FT PIERCE, FL, Permit Number:
Owner. SPEC HOME Jurisdiction: 661100
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic y pp g
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit'
/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the'cavity with
sealed. a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed. minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
-71
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side.
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls
Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed. !
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spa s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in,the building
shall be sealed to the drywall. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
mftAnd behind p*ping and wiring
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed!to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition,inspection of log walls shall be in accoryer dance with the provisions of ICC-400.
4/17/2018 2:48 PM EnergyGaugee USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
I
FORM R405-2017 Envelope Leakage Test Report Performance
I
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Performance Method
Project Name: RENAR HOMES WILSHIRE 1800 Builder Name: RENAR HOMES
Street: 9301 PORTSIDE DRIVE Permit Office: FT PIERCE
City,State,Zip: FT PIERCE, FL, Permit Number:
Design Location: FL,Fort Pierce Jurisdiction: 661100
Cond.Floor Area:: 1800 sq.ft. Cond.Volume: 16200 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
Single or Multi Point Test Data Required ACH(50)from
HOUSE PRESSURE FLOW: FORM R405-2017 :
1 Pa cfm
2 Pa cfm Tested ACH(50) "
3 Pa cfm
4 Pa cfm "Tested leakage must be less than or equal to the
required ACH(50)shown on Form R405-2017 for
5 Pa cfm this building. If the tested ACH(50)is less than 3
the building must have a mechanical ventilation
6 Pa cfm system.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(1)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be'tumed off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I
I hereby certify that the above envelope leakage Testing shall be conducted by either D�'iHES?"i
performance results demonstrate compliance individuals as defined in Section ti, s O
with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or her,,, ,t+
individuals licensed as set forth in �t�t�r...•..'% •ti,; `,,,,�`�;� r0
accordance with Section R402.4.1.2.
Section 489.105 3
approved third party.A written report of ....._...irs
r....
the results of the test shall be signed
SIGNATURE: by the third party conducting the test
PRINTED NAME: and provided to the code official. COD 1yy1r '�y
DATE:
BUILDING OFFICIAL:
DATE:
i .
4/17/2018 2:48 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
i
i
i
i
j I
i
Spec Home 9301 Portside Drive
HVAC Load Calculations
for
Renar Homes
II
INnVAC
I-€VAC L c)ADs
i
Prepared By:
Robert Weidman
Preferred Air Conditioning&Mechanical
1643 Donna Road
Wes alm B ch 1.
1 _
'1 7 O
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations areperformed er ACCA Manual J 8th Edition,pVersion 2, an n I
,I
IRhvac�-ReM4 ntia:
l&UghtCommercial HVAC Loads Elite Software Development Inc
Preferred Air Conditionatq&Meth Spec Home 9301.Portside Dnve,
u
West P616'9ea6h,.FL 33409 =� Pae2
Project Report
General Project Irif fmatio-h . . 777777
..
Project Title: Spec Home 9301 Portside Drive
Project Date: Tuesday, April 17, 2018
Client Name: Renar Homes
Company Name: Preferred Air Conditioning & Mechanical
Company Representative: Robert Weidman
Company Address: 1643 Donna Road
Company City: West Palm Beach, FI.
Company Phone: (561) 689-1093
Company Fax:
Company Website: GETCOLD.NET
Company Comment:
Des"g n'D`afa
Reference City. Fort Pierce, Florida
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 72 n/a
Summer: 90 78 59% 50% 75 61
C-,jbj(f tie
Total Building Supply CFM: 1,181 CFM Per Square ft.: 0.67
3
Square ft. of Room Area: 1,755 Square ft. Per Ton: 531
Volume (ft'): 14,040
Buildin Loads
Total Heating Required Including Ventilation Air. 38,631 Btuh 38.631 MBH
Total Sensible Gain: 28,441 Btuh 72 %
Total Latent Gain: 11,218 Btuh 28 %
Total Cooling Required Including Ventilation Air: 39,659 Btuh 3.30 Tons (Based On Sensible + Latent)
x
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 2018, 4:10 PM
I
i
Rhvac Resi ent�al&Light Gommerdial HYAC Loatls Elite Soft*re Deyela meet,Inc age,g5
Preferred Air Condd�antng&RAech Spec Home 9301 Potstde[3rlve
West Csa(iti`Beach, L'`33409'
Load Preview Report
Min Min Sys Sys Sys
Has Net ft.Z Send Lat Net Sen Duct
Htg Clg Htg Clg Act
Scope AED To /Ton Area Gainj Gain Gain Loss CFM CFM CFM CFM CFM Size
Building 3.30 531 1,755 28,441, 11,218 39,659 38,631 438 1,181! 438 1,181 1,181
System 1 Main Floor No 3.30 531 1,755 28,441 11,218 39,65P 38,631 438. 1,181 438 r1 181 1,181 12x17
Ventilation 2,473 6,226 8,698: 4,946
Supply Duct Latent 2,935 2,935
Zone 1 1,755 25,968 2,058 28,026 33.686 438 1,181 438, 1 181' 1,181 12x17
1-Family 224 3,872 230 4,102 6,,287 82 176 82 ', 176 176 1-8
2-Kitchen 234 5,089 448 5,537 9,847 128, 232, 128;,. 232; 232: 1-9
3-Powder Room 50 208: 0 208 588 8 91 8; 9' 9 1-2
4-Living 195 5,580 230 5,810 8,487 110 254 110; 254:i 254 1-9
5-Bedroom 3 132 2,186 230 2,416 1,302 17 99 17° ' 99°, 99 1-6
6-Bath 2 90 363 0 363' 494 6' 17 6 ,, 7 17 1-3
7-Loft/Br4 140 2,364 230- 2,594 1,349 18 108 18: 108': 108 1-6
8-Stairwell 154 1,012 0 1,012 807 10 46 10 46 46 1-4
9-Master Wic 77 266 0 266 358 5 12 5, 12 12 1-2
10-Master Bath 99 307 0 307 313 4 14 4;= 14 14 1-2
11-Master Bedroom 228 3,464 460 3,924 2,551 33 158, 33=, 158 158 2-5
12-Bedroom 2 132 1,258 230 1,488 1,302 17 57 17, 57 57 1-4
i
I
I
i
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday,April 17, 2018, 4:10 PM
� j
Rhvgq Residential$Light Commercial HVAC Loads " Elite Software_Developmenf,
ram Beach,�FL 3 409 ech Home 93
=r _.....;._ _W Spec - -
efe
01_Portside Dnv
estrP e
Fa e 4
Total Building Summary Loads
m` onenf Co
p h Area Sen Lat Sen Total
Desrr tion, Quan .- Loss" Gain Cain':'
ain Gain
RENAR SGD: Glazing-SGD .61 /.23, u-value 0.61, 39.6 725 0 554 554
SHGC 0.23
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 96 1,555 0 1,797 1,797
0.54, SHGC 0.25
RENAR SINGLE: Glazing-SHG .54/.25, u-value 0.54, 74 1,200 0 1,537 1,537
SHGC 0.25
11 F: Door-Wood -Solid Core With Metal Storm 42 352 0 306 306
11 D: Door-Wood-Solid Core 21 246 0 213 213
11 J: Door-Metal - Fiberglass Core 19.8 356 0 309 309
R-4.2: Wall-Custom, STUCCO BLOCK R4.2 DRYWALL 461.8 8,093 0 4,694 4,694
12B-Obw: Wall-Frame, R-11 insulation in 2 x 4 stud 1053.8 3,065 0 1,298 1,298
cavity, no board insulation, brick finish, wood studs
12C-Obw: Wall-Frame, R-13 insulation in 2 x 4 stud 115 314 0 126 126
cavity, no board insulation, brick finish, wood studs
1213-0sw: Wall-Frame, R-11 insulation in 2 x 4 stud 97 282 0 227 227
cavity, no board insulation, siding finish, wood studs
16BR-19-ml: Roof/Ceiling-Under Attic with Insulation on 224 329 0 549 549
Attic Floor(also use for Knee Walls and Partition
Ceilings), unvented attic with radiant barrier, R-19
insulation, light metal
1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 1042 1,000 0 1,667 1,667
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
17A-12: Roof/Ceiling-Roof Deck(roofing, wood, 40 76 0 106 106
insulation) or SIP Panels Supported on Beams, Dark
or Bold-Color Asphalt Shingle, Dark Metal, Dark
Membrane, Dark Tar and Gravel, 1.5"wood plus R-
12 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 115 4,685 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure: 22,278 0 13,383 13,383
People: 7 1,610 2,100 3,710
Equipment: 448 3,564 4,012
Lighting: 18 61 61
Ductwork: 11,408 2,935 6,663 9,598
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM: 150, Summer CFM: 150 4,946 6,226 2,473 8,698
AED Excursion: 0 0 197 197
- ----- - ---...__..........._......_..-- ......................_............---
Total Building Load Totals: 38,631 11,218 28,441 39,659
Check Fi ufes M
Total Building Supply CFM: 1,181 CFM Per Square ft.: 0.673
Square ft. of Room Area: 1,755 Square ft. Per Ton: 531
Volume (f?): 14,040
Bu Ming Loads
Total Heating Required Including Ventilation Air: 38,631 Btuh 38.631 MBH
Total Sensible Gain: 28,441 Btuh 72 %
Total Latent Gain: 11,218 Btuh 28 %
Total Cooling Required Including Ventilation Air: 39,659 Btuh 3.30 Tons (Based On Sensible+ Latent)
1.Nofesa.:
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 2018, 4:10 PM
i
Rhvac-Residential-&LighteCommercial HVAC Loatls' µ Elite Software Develo ment,inc,.'
P
Preferred Air Conditioq►�ng&Mech X Spec Home 9301 Portside Dnve_
West Palm Beach FL°�3409'
_.S
a e5
Total Building Summary Loads (cont'd
11 Notes, N
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
I
i
I
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday,April 17, 2018, 4:10 PM
� I
Rhvac Residential,&'tight Commercial HVAC Loads Elite Software:Development,Inc.
Preferred Air Conditioning&Mech Spec Home 9301 Portside.Drive,,
est .V11zPaltn Beach Ft `33409� Pa e_6-
S stem 1 Main Floor Summary Loads
Gomponent. Area Sen Lat_ Sen Total
Descri taon ; QUan doss Gain , s` _ aln my
RENAR SGD: Glazing-SGD .61 /.23, u-value 0.61, 39.6 725 0 554 554
SHGC 0.23
RENAR SIGH: Glazing-RENAR SINGLE HUNG, u-value 96 1,555 0 1,797 1,797
0.54, SHGC 0.25
RENAR SINGLE: Glazing-SHG .54/ .25, u-value 0.54, 74 1,200 0 1,537 1,537
SHGC 0.25
11 F: Door-Wood -Solid Core With Metal Storm 42 352 0 306 306
11 D: Door-Wood-Solid Core 21 246 0 213 213
11 J: Door-Metal - Fiberglass Core 19.8 356 0 309 309
R-4.2: Wall-Custom, STUCCO BLOCK R4.2 DRYWALL 461.8 8,093 0 4,694 4,694
12B-Obw: Wall-Frame, R-11 insulation in 2 x 4 stud 1053.8 3,065 0 1,298 1,298
cavity, no board insulation, brick finish, wood studs
12C-Obw: Wall-Frame, R-13 insulation in 2 x 4 stud 115 314 0 126 126
cavity, no board insulation, brick finish, wood studs
12B-Osw: Wall-Frame, R-11 insulation in 2 x 4 stud 97 282 0 227 227
cavity, no board insulation, siding finish, wood studs
16BR-19-ml: Roof/Ceiling-Under Attic with Insulation on 224 329 0 549 549
Attic Floor(also use for Knee Walls and Partition
Ceilings), unvented attic with radiant barrier, R-19
insulation, light metal
16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 1042 1,000 0 1,667 1,667
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
17A-12: Roof/Ceiling-Roof Deck(roofing, wood, 40 76 0 106 106
insulation) or SIP Panels Supported on Beams, Dark
or Bold-Color Asphalt Shingle, Dark Metal, Dark
Membrane, Dark Tar and Gravel, 1.5"wood plus R-
12 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 115 4,685 0 0 0
insulation below floor, any floor cover, passive, heavy
_ moist soil
Subtotals for structure: 22,278 0 13,383 13,383
People: 7 1,610 2,100 3,710
Equipment: 448 3,564 4,012
Lighting: 18 61 61
Ductwork: 11,408 2,935 6,663 9,598
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM: 150, Summer CFM: 150 4,946 6,226 2,473 8,698
AED Excursion: 0 0 197 197
System 1 Main Floor Load Totals: 38,631 11,218 28,441 39,659
Cheeck,Fi ures
Supply CFM: 1,181 CFM Per Square ft.: 0.673
Square ft. of Room Area: 1,755 Square ft. Per Ton: 531
Volume (ft'): 14,040
S stern LoadsWt
_
Total Heating Required Including Ventilation Air: 38,631 Btuh 38.631 MBH
Total Sensible Gain: 28,441 Btuh 72 %
Total Latent Gain: 11,218 Btuh 28 %
Total Cooling Required Including Ventilation Air: 39,659 Btuh 3.30 Tons (Based On Sensible+ Latent)
Notes ..
T
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 2018, 4:10 PM
I
I
g C Loads „" Elite Software Development,Inc
Prefe ed As'Condao&�n' &Mech merc�ai HVA Spec Home 9301'Portside Drive,
. .
WesfPafmBeach,FL�33409� _ =Pa e.7
S stem 1 Main Floor Summary Loads (cont'd)
Notes - 7777771
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 2018, 4:10 PM
Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc
Preferred Air Conditioning&Mech Spec Home 9301 Portside Dnve_
r r _.
V11est"Pa{riiBeachFL-"33409 ., = ,_ Pa'e 8
E ui ment Data - System 1 - Main Floor
Cooling
System Type: Air Source Heat Pump
Outdoor Model: CH14NB042*0**A*
Indoor Model: FB4CNP048L
Tradename: CARRIER AIR CONDITIONING
Outdoor Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
AHRI Reference No.: 9162731
Capacity: 40000
Efficiency: 14 SEER
Heating
System Type: Air Source Heat Pump
Model: CH14NB042*0**A*
Tradename: CARRIER AIR CONDITIONING
Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
Capacity: 41000
Efficiency: 8.2 HSPF
I
I
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 2018, 4:10 PM
Rtiv c Residential Lrght Commercial,HVA_ Elite Software Deve. ..... Inc.
Preferred Air Conditioning&Mach w: Spec Home 9301 Portside„Drive
-
_. , .. _
West f?ilm Beach_,FL<33409 F a e 8
System 1, Zone 9 Summary Loads (Average Load Procedure for Rooms)
Component Area Sen Lat Sen .Total'
Descri tion Quan. .,.a, :_Loss Gain Gain'` Gain
RENAR SGD: Glazing-SGD .61 / .23, u-value 0.61, 39.6 725 0 554 554
SHGC 0.23
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 96 1,555 0 1,797 1,797
0.54, SHGC 0.25
RENAR SINGLE: Glazing-SHG .54/ .25, u-value 0.54, 74 1,200 0 1,537 1,537
SHGC 0.25
11 F: Door-Wood-Solid Core With Metal Storm 42 352 0 306 306
11 D: Door-Wood -Solid Core 21 246 0 213 213
11 J: Door-Metal - Fiberglass Core 19.8 356 0 309 309
R-4.2: Wall-Custom, STUCCO BLOCK R4.2 DRYWALL 461.8 8,093 0 4,694 4,694
12B-Obw: Wall-Frame, R-11 insulation in 2 x 4 stud 1053.8 3,065 0 1,298 1,298
cavity, no board insulation, brick finish, wood studs
12C-Obw: Wall-Frame, R-13 insulation in 2 x 4 stud 115 314 0 126 126
cavity, no board insulation, brick finish, wood studs
1213-0sw: Wall-Frame, R-11 insulation in 2 x 4 stud 97 282 0 227 227
cavity, no board insulation, siding finish, wood studs
16BR-19-ml: Roof/Ceiling-Under Attic with Insulation on 224 329 0 549 549
Attic Floor(also use for Knee Walls and Partition
Ceilings), unvented attic with radiant barrier, R-19
insulation, light metal
1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 1042 1,000 0 1,667 1,667
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
17A-12: Roof/Ceiling-Roof Deck(roofing, wood, 40 76 0 106 106
insulation) or SIP Panels Supported on Beams, Dark
or Bold-Color Asphalt Shingle, Dark Metal, Dark
Membrane, Dark Tar and Gravel, 1.5"wood plus R-
12 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 115 4,685 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure: 22,278 0 13,383 13,383
People: 7 1,610 2,100 3,710
Equipment: 448 3,564 4,012
Lighting: 18 61 61
Ductwork: 11,408 0 6,663 6,663
Infiltration: Winter CFM: 0, Summer CFM: 0 0 _ 0 _ 0_ 0_
System 1, Zone 1 Load Totals: 33,686 2,058 25,968 28,026
Check.Figures ures
h
Supply CFM: 1,181 CFM Per Square ft.: 0.673
Square ft. of Room Area: 1,755 Square ft. Per Ton: 751
Volume (ft'): 14,040
:Zonq,Loads,
..
Total Heating Required: 33,686 Btuh 33.686 MBH
Total Sensible Gain: 25,968 Btuh 93 %
Total Latent Gain: 2,058 Btuh 7 %
Total Cooling Required: 28,026 Btuh 2.34 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\...\RENAR WILSHIRE 1800 MCMILLAN.rh9 Tuesday, April 17, 20181, 4:10 PM
Rhvac�entiall&Light Commercial HUAC Loatls 3 Elite Software Development,Inc u
Preferred Air Gondittonr 9,&Mech Spec Horne 9301 E Portside Drive
WesfiPaim Beach;Ff 33409'', m'' .< . Pa- a 10'
System 1 Room Load Summa
Htg= Mtn Rai Run CI` r CI lion Act
Rootn AreaE Sens' Htg Duct Duct Sens Lat Clg Sys;
No , lame SFCFM Size . i Vel „Btuh„,a 'Btuh F. CFM ,.,..<..,'CF.M,
---Zone 1---
1 Family 224 6,287 82 1-8 505 3,872 230 176 176
2 Kitchen 234 9,847 128 1-9 524 5,089 448 232 232
3 Powder Room 50 588 8 1-2 435 208 0 9 9
4 Living 195 8,487 110 1-9 575 5,580 230 254 254
5 Bedroom 3 132 1,302 17 1-6 507 2,186 230 99 99
6 Bath 2 90 494 6 1-3 336 363 0 17 17
7 Loft/Br4 140 1,349 18 1-6 548 2,364. 230 108 108
8 Stairwell 154 807 10 1-4 527 1,012 0 46 46
9 Master Wic 77 358 5 1-2 554 266 0 12 12
10 Master Bath 99 313 4 1-2 640 307 0 14 14
11 Master Bedroom 228 2,551 33 2-5 578 3,464 460 158 158
12 Bedroom 2 132 1,302 17 1-4 656 1,258 230 57 57
Ventilation 4,946 2,473 6,226
Duct Latent 2,935
.----..._.........System 1 total 1,755 38,631 438 ---------.._...............--- 28,441 -- 11,218........_.__._._1,181...._.................._.1 181......
System 1 Main Trunk Size: 12x17 in.
Velocity: 834 ft./min
Loss per 100 ft.: 0.100 in.wg
Cooln °,S"stem'_S�'ft nia "
_. .. .... ... .x_ _ , ...
Caoyng? Setistbte/Laatent Sensible Latent, Total:'
-Nona Sit,..� �tuh_ Bfu , Btufi.z
Net Required: 3.30 72%/28% 28,441 11,218 39,659
Actual: 3.33 75%/25% 30,000 10,000 40,000
Heating System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
Model: CH14NB042*0**A* CH14NB042*0**A*
Indoor Model: FB4CNP048L
Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.2 HSPF 14 SEER
Sound: 0 0
Capacity: 41,000 Btuh 40,000 Btuh
Sensible Capacity: n/a 30,000 Btuh
Latent Capacity: n/a 10,000 Btuh
AHRI Reference No.: n/a 9162731
C:\...\RENAR WILSHIRE 1860 MCMILLAN.rh9 Tuesday, April 17, 2016, 4:10 PM
i ,