Loading...
HomeMy WebLinkAboutProduct Approval Horjda Building Code Online • 1le�'� • OERMIT# 0000 125298 �T y .�e 2 4 7th treet, Fort Pierce, FL Business & pc Professional 005 Moms Log In User Registration Hot mit-Su hag Ay Si1It Publicatims FSC Stall SCIS Site Map Links Search dbpr4Product Approval 4 NCFALED FASTENERS Or�ATTACHMENT 4 USE0.:Public User ARE THE RESPONSIBILITY OF THE Product Approvai Menu>Product or Application Search>Ape9caoon List>Application Detail CONTRACTOR OF RECORD FL# FL1654-R20 ) Application Type Revision Code Version 2014 yg +� Application Status Approved 166E PLANS AND ALL PROPOSED WORK Comments Alit SUBJECT TO ANY CORRECTIONS Archived 1"IMUIREC DY FIELD INSPECTORS THAT !iA`�Sr;NE IARY-IN ORDF.R TO Product Manufacturer POLYGLASS USA (a :.1, +, Address/Phone/Email 150 Lyon Drive COIMIPLY.�'�n ALL APPLICAQ CODESr" Fernley,NV 89408 (570)384-1230 Ext242 jakins@polyglass.com 4 1 * Authorized Signature James Akins �_ 5 04 v` jakins@polyglass.com S LL ( '1 C�'•_''Tl TZI-P rr�;r DIVISION RFw'i� Technical Representative Steve Wadding ttt 1't: !i r. n• Address/Phone/Email 150 Lyon Drive DATE L Fernley,NV 98408(602)363-7139 PL.k-; :irk PF TLNIIT Nf U ST BE KEPT 0NJ0.33 stevew@polyglass.com C'_'_NO LNSPECT!ON NVILL BEE h E. Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton, PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL1654 R20 QQI 2017 01 COI Nieminen.g0f Referenced Standard and Year(of Standard) Standard Year ASi"M D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 FM 4474 2004 littp://x%-w\r.floridabLIi iding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w`/`2bnF... 5/22/2017 1~lorida Building Code Online Page 2 of 2 t • UL 1897 2008 Equivalence of Product Standards Certified By Sections from the Code • Product Approval Method Method 1 Option D Date Submitted 02/15/2017 Date Validated 02/16/2017 Date Pending FBC Approval 02/18/2017 Date Approved 04/04/2017 Summary of Products FL# Model,Number or Name Description 1654.1 Polyglass SBS and APP SBS and APP modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R20 II 2017 02 FINAL Al ER POLYGLASS MODBIT FL1654- Approved for use outside HVHZ:Yes R20.odf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R20 AE 2017 02 FINAL ER POLY LASS MODBIT FL1654- over concrete deck. Refer to the ER Appendix for R20.0df other systems and deck types. 2.)Refer to ER, Created by Independent Third Party: Yes Section 5 for other Limits of Use. Beck Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Cam' ® etk`_ Credit Card Sate http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w°/D2bnF... 5/22/2017 EXTERIOR RESEARCH& DESIGN, LLC. Certificate of Authorization#9503 TRINITY ERD 353 Christian Street Oxford,CT 06478 a (203)262-9245 EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P9290.02.08-1118 150 Lyon Drive FL1654-1120 Fernley, NV 89408 Date of Issuance:02/11/2008 (570)384-1230 Revision 18:02/15/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 51h Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 55-page Appendix. Prepared by: st,,utntrn, •...,c..�s V: :W The facsimile seal appearing was authored Robert J.M. Nieminen, rrFS�,' by Robert Nieminen,P.E.on 02/15/2017 eminen, P.E. ,'�q� `� 4 . This does not serve as an electronically signed document.Signed, Florida Registration No.59166,Florida DCA ANE1983 J"""" sealed h r ¢ g a dcopies have been transmitted to the Product Approval OP Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have,nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD • Entity Examination Reference Date FM Approvals(TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals(TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals(TST1867) FM 4470 3006646 01/04/2000 FM Approvals(TST1867) FM 4470 3001334 01/25/2000 FM Approvals(TST1867) FM 4470 3001334 02/15/2000 FM Approvals(TST1867) FM 4470 3000857 01/12/2000 FM Approvals(TST1867) FM 4470 3004091 01/12/2000 FM Approvals(TST1867) FM 4470 3006115 05/02/2001 FM Approvals(TST1867) FM 4470 3012321 07/29/2002 FM Approvals(TST1867) FM 4470 3014692 08/05/2003 FM Approvals(TST1867) FM 4470 3014751 08/27/2003 FM Approvals(TST1867) FM 4470 3007170 01/13/2004 FM Approvals(TST1867) FM 4470 3019317 06/30/2004 FM Approvals(TST1867) FM 4470 3020703 07/30/2004 FM Approvals(TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals(TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals(TST1867) FM 4470/4474 3024594 05/23/2006 FM Approvals(TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals(TST1867) FM 4470/4474 3030668 09/12/2007 FM Approvals(TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals(TST1867) FM 4470/4474 3049631 04/21/2014 FM Approvals(TST1867) FM 4470/4474 3057029 02/02/2017 PRI(TST5878) Physical Properties PUSA-062-02-01 12/04/2007 PRI(TST5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST5878) Physical Properties PUSA-064-02-02 02/27/2008 PRI(TST5878) Physical Properties PUSA-062-02-02 12/04/2008 Miami-Dade(CER1592) HVHZ Compliance Various NOAs Various Miami-Dade(CER1592) Proposal for Review 10-0823 10/12/2010 UL LLC (QUA9625) Quality Control Service Confirmation,R14571 Exp.10/06/2018 4. PRODUCT DESCRIPTION: This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1:ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Polyglass G2 Base ASTM D4601 N/A II Base Sheets Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163,Table 2 S I Elastoflex SA V FR Base ASTM D6163,Table 2 S I SBS Membranes Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I Exterior Research and Design,LLC. Evaluation Report P9290.02.08-1118 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL1654-1120 Polyglass USA,Inc. Revision 18:02/15/2017 Page 3 of 6 TRINITY ERA TABLE 1(CONTINUED):ROLL-GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Elastoflex 56 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS(sand or poly-film backed) ASTM D6164 G I Polyfresko G SBS FR(sand or poly-film backed) ASTM D6164 G I SBS Membranes Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I APP Membranes Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S 1 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E.are, in anyway,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in 1FBC 2603.4.1 or 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. Exterior Research and Design,LLC. Evaluation Report P9290.02.08-R18 Certificate of Authorizotion#9503 FBC NON-HVHZ EVALUATION FL1654-R20 Polyglass USA,Inc. Revision 18:02/15/2017 Page 4 of 6 TRINITY ERD APPENDIX S:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page SA Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 18-1 wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9 18-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12 11) Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 13-14 1E wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 15-16 1F-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 17-19 1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 20-22 1G wood New or Reroof(Tear-Off) F }! Non-Insulated,Bonded Roof Cover 22 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 23-26 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 27-29 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 30-31 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 32-38 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 38 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 39-40 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 41 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 42-44 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 45 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 46 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 47 SD CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 47 5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 48-SO 66 Gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 6C Gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 51 6D Gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 52-55 7B Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover SS The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanu rate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9S03 FBC NON-HVH2 EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 1 of 55