Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY City,State,Zip: F PIERCE FL Permit Number: Owner: �j �,��-��e Jurisdiction: D Isign Location: FL,West Palm Beach �� County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ftz b.Frame-Wood, Exterior R=11.0 187.33 ftz 3. NIumber of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 2 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ftz 6. Conditioned floor area above grade(ftz) 1446 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(139.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 320 a, U-Factor: Dbl, U=0.54 99.23 ftz SHGC: SHGC=0.25 b! U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c! U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d� U-Factor: N/A ftz a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. A�ea Weighted Average SHGC: 0.250 14.Hot water systems 8. Flloor a.Electric Cap:40 gallons Types (1446.0 sqft.) Insulation Area a,Slab-On-Grade Edge Insulation R=0.0 1446.00 ftz b. Conservation features EF:0.970 b!N/A R= ftz None c N/A R= ftz 15.Credits Pstat Glal s/Floor Area: 0.096 Total Proposed Modified Loads: 53.72 PASS Total Baseline Loads: 54.66 I hereby certify that the plans and specifications covered by Review of the plans and o4�HE S7.4 this calculationare in compliance with the Florida Energy specifications covered by this _ Off, Code. calculation indicates compliance with the Florida Energy Code. ruin'"•. „ O PREPARED Ry. Before construction is completed DATE: this building will be inspected for O compliance with Section 553.908 * 'Q I he certify that this building, as designed, is in compliance Florida Statutes. witli the Florida Energy Code. COI)WE OWNER/AG NT: -� BUILDING OFFICIAL: DATE: L DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I i )ORM R405-2014 PROJECT Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME PeIrmit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range ' FL,West Palm Beach FL WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium I BLOCKS Number Name Area Volume 1 Entire House 1446 12514.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated BEDROOM 234 1872 No 2 1 1 Yes Yes Yes WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes KITCHEN 172 1376 Yes 0 1 No Yes Yes BATH 45 . 360 No 0 1 Yes Yes Yes BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 5154.8 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ____ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0 4Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 -_-- 0 1 0 7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ____ 0 1 0 I 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 I , ORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER. 7 ft 0 50 ft2 ---- 0 1 0 I ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Vi # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 i ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood I WALLS Adjacent S p ace Cavity Width Height Sheathing Framing Solar Below 9 Orat In Wall Type R_VaI1,e In Et In Xallie I Ft Area R 1 N=>SE Exterior Concrete Block-Ext InsIflEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext Ins1HEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext InsIBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block-Ext InddWSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block-Ext InREDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block-Ext InQEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block-Ext IndREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block-Ext InQEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 11 S=>NW Exterior Concrete Block-Ext InsLUAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block-Ext In,ii REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 I a I 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I ORNI R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 1 :a arnt In Wall Type Space R_Va 113 W=>NE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 115 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 16 N=>SE Exterior Frame-Wood GREAT/DINT 11 23 5 8 187.3 ft2 0.23 0.5 0 i DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 I WINDOWS Orientation shown is the entered orientation => changed to Worst Case. ` Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None I GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000385 1460.1 80.16 150.74 .2656 7 HEATING SYSTEM # System Type Sub y yp type Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 I I I I- 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 Li -RM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage j Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I i DUCTS —Supply-- --Return-- Air CFM 25 CFM25 HVAC# Vi # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool i 1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb ]Mar Apr [ ]Ma X Jun [X]Jul rj Au �Xj Se [ ]Oct H Nov H Dec Heatin Jan Feb �X]Mar f Apr [ ]May 4 j Jun [ ]Jul AuSep [ ]Oct Nov Dec Vei Jan Feb X Mar [X]A r [ ]Ma [ Jun [ ]Jul Aug Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 i Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i i I� 411/2117 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 �i FORM R405-2014 � TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,West Palm Beach COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or J unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub,on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. ,Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i FORM R405-2014 ENERGY PERFORMANCE LEVEL EPL DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*, = 98 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ftZ i b.Frame-Wood,Exterior R=11.0 187.33 ft 3. Number of units,if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d.N/A R= ftz Is this a worst case? 10.Ceiling Types Insulation Area 5. Yes a.Under Attic(Vented) R=30.0 1446.00 ftz 6. Conditioned floor area(ftz) 1446 b.N/A R= ftz z 7. Windows- Description Area c. R= ft z a. U-Factor: Dbl, U=0.54 99.23 ftz 11.Duct s R ft a.Sup:Attic, Ret:Attic,AH:Attic 6 320 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 40.00 ftz SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00 SHGC: . U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft EF:0.97 b.N/A R= ftz b. Conservation features c.N/A R= ftz None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building zBEST Construction through the above energy saving features which will be installed (or exceeded) �yo4 Ado in this home before final inspection. Otherwise, a new EPL Display Card will be completed yak", '0��� based on installed Code compliant features. Builder Signature: Date: Address of New Home: Q Ci /FL Zip \U� -� tY WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 `- wrightsoft Project -1 MM'ary Date:"epy Entire House lay. QUICK CALLS, INC. 317 St. LN.LUCIE ,FT.PIERCE,ffL 34946 Phone:772)66j6799 Fax 772-466-6796. Email:QUICKCALCS@!Aq .COM: Project Information For: THE GRAN D CARLTON WY NE DEVELOPMENT, FT. PIERCE, FL Notes: tes: 1 i f Design ••Feather •Fort Pierce, FL, US Winter Design Conditions St mmer Design Conditions Outside db 42 OF Outside;db . 90 OF Inside db 70 OF Inside db. 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative;humi lity 50 % Moisture diffe ence 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cf ). 0 Btuh Central Vent(0 cfm) 0 Btuh (none) (none) Humidification 0 .Btuh Blower 0 Btuh Piping I 0 Btuh Equipment load 23503 Btuh. Use manufac urer's data n Ratelswing m iltiplier 0.95 Infiltration Equipmenf sensible load 24753 Btuh. Method Simplified Latent Cooling-E ui meet Load Skin Construction qualit. Average q p g Fireplaces 0 Structure 3203 Btuh Ducts . 2318 Btuh Central vent(0 cfm) ! 0 Btuh, Heatiiggl Coolingg (none) Area(ftz) 1446 1446 Equipment lati nt load 5521 Btuh Volume(ft3) 125�1 i 12511 Air changes/hour 0.45 0.23. Equipment total load 30274 Btuh Equiv.AVF(cfm) I i 48 Req. total capacity at 0.70 SHR 2.9 ton Heating gquipment Summary Cooling Equipment Summary Make Carrier Make Gamer Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 I Con d 2.5HBC536A*030 AHRI ref 7914585 Coil FiX4DN(B,F)037 AHRI ref 914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating.lnput Sensible cooli g ! 24360 Btuh Heati 34600 .Btuh @ 47°F Latent cooling 10440. Btuh Temperature rise 27. °F Total cooling ! 34800 Btuh Actual air flow.. 1160: cfm Actual airflow 1160 cfm Airflow factor 0.049 cfm/Btuh Airflow factor{ 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat. Load sensible heat ratio 0.83 Capacity balance point=32 OF Backup: Input=7 kW; Ou put 23009 Bt h, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. • I I 2017-A r-11 09:29:38 wrightsc . Right-Suite®Universal 2017 17.0.14 RSU08101 p paged ...uick Calcs\Document 1THE GRAND CARLTONi1446.rup Calc=MJ8 Front Door faces: N i '• I +wrightsoft Right-J®Worksheet Job: Entire House Byte`; QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,F)L 34946 Phone:772 66�799 Fax 772-466-6796 Email:'QUICKCALCS@A(YL.COM 1 Room name Entire House BEDROOM 2 F�osed wall 156.2 ft 49.0 ft 3 Room height. 8.7 ft d 8.0 ft heat/cool 4. Room dimensions 11.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2; Ty Construction U-value Or HTM Area (ft2) oad Area (ft2)1 Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Coal. Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs*' 0143 ,ri. I 400 2.55 b03 465 I 1862 1184 72 72 :288 183 _4A5 tom 0 770 n 21c56 .1931 38 0 615 _ 730 0' .i 0 ";0 < 0 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 IA-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 ��----DD 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.55 34 34 ' {36 86 : .0 ..I. 0 "' . .6. 6 V)I 360 353 1414 899 216 216 865 550 �--G 7 7 747 241 0 0 0 0 13A-0ocs 0143 s 4.00 255 �4 1Ac1om 1270 s i 3556 34.77 13A46cs 0143 w 4.00 2:55 310 237 72 .288 183 9 603 104 1Ac1om 1 270 :;w 35.56 65.21. •32- 2 T40 1770 32 { 2 1140 1776. 4A5 tom 0 770 w 21.56 1.9;31 41 41 . -' 0 788._ 0 - I '0 P 12C-0sw 0.091 I 2.55 1.28 192 192 89. 246 0 0 0 0 C , 16A 30md 0 032 09Q., 2.32 1446: '1446 1 95: '. 3354 - 297 t` 297 .-266 689 F 22A-tpl 0.989 27.69 0.00 1446 156. 4, 0 247 49 1357 0.40 -f I i I I - i j 6 c)AED ex;ursion I I I 918 i 627 Envelope loss/gain I I 14951 13349 ! 4204 4003 12 a). Infiltration . 2887 791 848 232 b) Room ventilation I 0 0 0 0 13 Internal gains: Occupants @ I 230 6 1380 3 .690 Applianceslother 20M 0 Subtotal(lines 6 to 13) I 17848 17520 5053 4925 Less extemal load I 0 0 6 0 Less transfer 0 0 0 . 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 2*3 26056 6653 7325 Air required(cfm). I 110 1160 " 328 326 LCalculations a roved b ACCA to meet all r uirement�of Manual J 8th Ed. • wrightsoft` I 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...ulck CalcslDocument \THE GRAND CARLTON j1446.rup Calc=MJ8 Front Door faces: N I I Job: - wrightsoft° Right-Ji).Worksheet pace' Entire House QUICK C LCS, INC. By 317 ST.LUCIE LN.,FT.PIERCE, II L 34946 Phone:772166-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOIL.COM 1 Room name WIC KITCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft, heattcool 4 Room dimensions 6.0 x 9.0 ft 11.0 "x. 172.0 ft 5 Room area 54.0 ftz 172.0 ft?, Ty Construction U-value Or HTM Area (ftz) (Load Area (ft�j Load number (13tuh/ft2-°F), (Btuhlftz) 1 or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross WP/S Heal Cool Gross I UP/S Heat Cool 6 13A13ocs`; 0143 n 4;00 2,55 0 0' 0 _ 0: 0 ( 0 0 0 "#A5 tom 0 770: nl" 21:56 1931 0 0' 0 0 0' 0 0 '' 0 13A-4ocs 0.143 e ; 4.00 2 55 0 0 0 0 0 0 0 0 —G IA-c1om 1.270 e� ; 35.56 87.29 0 0 .0 0 0 0 0 0 11 �---D 11DO 0.390 el 10.92" 11.31 0 0 0 0 0 0 0 0 W:; '':13A ocs 0:143 s 4.00;" 2.55 0 0 0", 0 :0 ` j 0 0 0 W 13A-4ocs 0.143 s " 4.00 2.55 0 0 0 0 0 0 0 0 L- G 1A-c1om 1.270 s 35.56. 34.7! 0 0 0 0 0 0 0 0 13A�ocs 0143 wII 4,00 2.55 0 0 0 .0 0 0 0 0 1A c1om: 1.270 W 3556 55:21 0 0 0 0 0 0 0 0 ::4A52om:r A7,70 -.W; 21;56 19.31: 0 0 j_" 0 .0 P• 12C osw , 0.091 - 2.55" _ 1.28. 0 0 0 0 64 _ 64 163 82 C " "?,16A-30md` 0 032 0;90 2 32 54;.. 54 48 125 r .. :..172. :'172 154 399 F 22A-tpl _ 0.989 - 27.69 0.06 64 0 0 0 172 0 0 0 _ I 6 c)AED excursion I I -9 -170 Envelope losstgain I ( �48 117 317 311 I 12 a) Infiltration I 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: I Occupants 230 0 U 0 i 20 0 Applia0. Subtotal pines 6 to 13) I 117 317 2311 Less external load 0 0 i 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal p8 117 317 2311 15 Duct loads 32% 49% j15 57 32% 49% 100 1126 Par equireedoom l`cfm) � 178 421 3437 153 Calculations apprIoved byACCA to meet all require;menl of Manual J 8th Ed. c - - wrightsoft- ! 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...uick Calcs\136cumentE kTHE GRAND CARLTONI1446.rup Cale=MJ8 Front Door faces: N i i I I - -wr�ghtsoft° Right-JO Worksheet °b Date:' Entire If use QUICK C I CS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772 6 I 799 Fax 772466-6796 Email:QUICKCALCS al gL.COM 1 Room name BATH BEDROOM 2 2 Eq)osed wall 5.0 ft i 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft i heaticool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2: Ty Construction U-value Or i HTM Area (ft2) (Load Area (ft2)I Load number (Btuh/ft2_T) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) j Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat. Cool 6 V�1 13A flocs ;0143 .n 4 00 256 40 40' 60 r" 102" 128 - 128 513 326 I. G '4A52orimi' ;I n I 21 56 1931 0 0 0 0` 0 0 0 0 V)1 13A-4ocs 0.143 e I 4.00 2.55 0 0 0. 0 80 56 225 143 I�—GD 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 e l 10.92 11.31 0 0 0 0 0 0 0 0 1N 13A-4ocs 0:143 s( .4m;. 2'55 0 0 0 . 0 34 i 34 136 86, Vll 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 L—G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-0ocs 0143 yv 4;00 2 55 ' 0' 0 0 0 0 0 0 0 1Ac1om-_ 270 w 3556 55.21 0 0 0: 0 0: 0 °0 :1 0, 4A5 tom%; 0 T/0 2156 19.`31 - 0- 0 i': 0 0 0 0 '0 0' P 12C-0sw 0.0911 - 2.55 1,28 0 0 0 0 0 0 0 0 C <16/k30md= '0.032 ..:- 6. 0 2;32 '.. 45 45:;" "` 46 104 204 { 204 162 472 F 22A-to 0.989 - 27.69 0.00 45 5 . 38 0 204 { 34 946 0 9 i f 1 I I - f I 6 c)AED exursion -16 ! -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . I I 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ I 230 0 0 1 230 Appliances/other j 0 0 Subtotal pines 6 to 13) . I I 4�5 214 3571 3498 j Ili Less external load � 0 0 0 0 Less transfer 0 0 I 0 0 Redistribution 0 0 0 0 14 .Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 1 104 32% j 49% 1131 1704 Total room load 0 318 4702 5203 Air required(cfm) 8 141232 232 I i �.Calculatlons -t a roved b ACCA to meet all r uirement of Manual J 8th Ed. � w- " rights f ' �. 2017-Apr-11 09:29:38 � Right-Suite®URiversal.2017 17.0.14 RSU08101 Page 3 ...ulck Calcs\Document\THE GRAND CARLTO.1446.rup Calc=MJ8 Front Door faces: N I I i i I • ' - wrightsoft, Right-Ji®Worksheet °b Entire th use Datea QUICK CALLS, INC: By 317 ST.LUCIE LN.,FT.PIERCE,FL 34946-Phone:772�6616799 Fax 772.466-6796 Email:QUICKCALCS@AgL.COM I 1 Room name FOYER M.BATH 3 Room heightsed 8.0 ft 7.0 ft eat/cooi 8.0 ft 8.0 ft heat/cool 4, Room dimensions. 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ftz 56.0 ft2i Ty .Construction LI-value Or HTM Area (ft2) ad Area Lo number (Btuh/ft�'F) (Btuhlft2) or perimeter (ft) Both) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heatl I Cool Gross N/P/S. Heat Cool 6 13A flocs; 0143 ri: 4:00 255 8 8 1 32 20 0 i 0 - rp 0. '4A5 tom =:0 770 :n I 2115.8, 1931 0 0 9 0 .. p ..:`:0 . 13A-4ocs 0.143 a 4.00 2.55 48 27 08 69 0 0 0 0 IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W :` 13AAocs' Oi143 s 4;00 2:55 0 0 0 0 0 0 0 0 V)/ 13AAocs 0.143 s 4.00 2.55 0 0 0 0 64 57 226 145 t-G 1A-c1om 1270 s 1 35.56 34.77 0 0 0 0 7 7 247 241 1 -4ocs w 0143 4.00 255 0. 0 0 ' 0 0 0 I 0 :0 V{�--G 3A1Ac1om 1270 w 35:58 55 21 0 0 , 0 0 0 0 r-G ;4A52om' 0 770 w.` 21:56 19c31 0 0.i 0 0 P 12C-Osw, 0 091 im, 1.28 72 72 83 92 0 i 0 .0 0 O 16A-30mtJ:i. 0 032 . 0 90 2:32 :50 . 50 ,:..: 116 56 j .t 56 50 ;.130 F 22A tpl 0 989 - 27.69 0.00 50 7 19944 0 56 l 8 222 0 4. I .. I I , i 6 c)AED excursion I I I I -39 -38 Envelope loss/gain 792 M 747 478 12 a) Infiltration 121 33 i 138 . 38 b) Room ventilation 10 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/othe i 0 i 0 Subtotal pines 6 to 13) I ( 913 529 885 . 516 Less external load I 0 0 i 0 0 Less transfer I 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 8B5 516 1151 Duct loads 32% 49% 28I9 2% 32% 49% 2801 251 Total room load- ( 121 12 787 1166 768 Air required(cfm) 59 35 58 34 i Calculations a rl ved by ACCA to meet all re uirementl of Manual J 8th Ed. wr.ightsot' Right-Suite@ Universal 201717.0.14 RSU08101 l 2017-Apr-11 0 Page 5 ...uick Calcs\Documents hTHE GRAND CARLTON-1446.rup Calc=MJB Front Door faces: N i i . -�+ wrightsoft. Duct Sys lem Summary pat Entire House By: QUICK CAL�CS,INC. 317 ST.LUCIE LN.,FT.PIERCE,�L 34946 Phone:.772 66-6799:Fax 772-466-6796 Email:QUICKCALCS@AOL.COM I:.I I . Project Information For THE GRAND CARLTON WYNNE DEVELOPMENT, FT PIERCE, FL i Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in 420 Available,static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate I 0.285 in/100ft 0.285 in/1001"t Actual,air flow 1160 cfm 1160 cfm; Total effective length(TE ) 176 ft Supply design ME i Clg Design . Diam H YI W Duct Actual] Ftg.Egv Name (Btuh) (cfm) I (cfm) FIR (in) (irk) Matl Ln(ft)1 Ln(ft) Trunk BATH h 560 ?8 14. 0.364 .4.0 Ox 0 VIFx 22.4' 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0.- st1 BEDROOM-A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Oxq VIFx 40.6 ! 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxC VIFx 4.0 I 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox( VIFx 31.8 ; 135.0 st2 GREAT/DINING-A h 3946 19$ 169 0.300 7.0 Ox0 VIFx 31.81 135.0 st2 KITCHEN c 3437 21! 153 0.379 6.0 Ox( VIFx 17.0 ! 115.0 st1 LAUNDRY h 846 j42 20 0.361 4.0 OxC VIFx 23.3 115.0 st1 M.BATH-A h .768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Oxc VIFx 27.0.1! 135.0 st2 LI d i SupplyDetail Table I II I Trunk Htg Clg Design Veloc Diam H x W I Duct Name Type I. (cfm) (cfm) FIR (fpm). (in) (in) Material Trunk st2 Peak AVF 721 1672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 11091 0.285 1020 14.0 0 x 0 VinlFlx j i j I `, Wf 1 a 2017-Apr-11 09:29:38 911t50 Right-Suite®U ivelrsal 2017 17.0.14 RSU08101 page 1 di ...uick Calcs\Documents THE GRAND CARLT N-1446.rup Calc=MJ8 Front Door faces: N I i i I I ' 9 tt t Return Branch Detail Table Grille F�tg 1-cIg _ TEL Design Vdoc Diam H x W Stud/Joist. Duct Name Size(in) (cfm) (cfm) (ft) FIR . . (fpm). (in) . (in) Openingj(in), Mati Trunk. rb1 Ox0 1160 1160 0 0 0 0 I Ox 0 VIFx t I I I . i I I I I i i I I I " i i I I is i I i I i . i i j I I' i if t Wrl htS0 If 2017-Apr-11 0929:38 . � "f 9 Right-Suite®U iveirsal 2017 l7.0.14 RSU08101 Page 2 ...uick Calcs\Documents THE GRAND CARLT N-A446.rup Calc=MJ8 Front Door faces: N I I I .