Loading...
HomeMy WebLinkAboutProduct Approval - underlayment Florida Building Code Online • File C©p gelof2 Business & Professional Regulation r0= BCIS Home Log In ' User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links -Search bar Product Approval\.lUSER Public User Product Approval Menu>Product or Application Search>Aoohca[ion List>Application Detail .a. • ' FL# FL10450-R8 0 ., �' Application Type Revision Mn1NI 8 � 1 Code Version 2014 QFRi,A1T- il\j^ Application Status Approved St. LU--i@ I� o ,i unty, FL Comments Archived Product Manufacturer Tarco Roofing Address/Phone/Email One Information Way Suite 225 Little Rock,AR 72202 (254)913-7750 smohseen@tarcoroofing.com Authorized Signature Shaik Mohseen smohseen@tarcoroofing.com Technical Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 76513 (254)913-7750 smohseen@tarcoroofing.com Quality Assurance Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 78717 (254)939-3775 Ext210 smohseen@tarcoroofing.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/13/2017 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL10450 R8 COI 2016 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D3909 1997 ASTM D4869 200S ASTM D6164 2005 ASTM D6380 2003 FM 4474 2004 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDqudsDrIH614890... 5/18/2017 Flprida Building Code Online • • Page 2 of 2 FRSA/TRI April 2012(04-12) 2012 TAS 103 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated Date Pending FBC Approval 04/25/2016 Date Approved 06/08/2016 Summary of Products FL# Model,Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL10450 R8 II 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450- Approved for use outside HVHZ:Yes R8.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party: Yes Other: 1.)The design pressure herein Evaluation Reports pertains to one particular bonded FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450- underlayment application for use beneath R8.Ddf adhesive-set tile systems. Refer to ER Section Created by Independent Third Party: Yes 5.6.2 for details,and other bonded underlayment systems. 2.)Refer to ER Section 5 for Limits of Use. Back Next Contact Us::2601 8lair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ®® E Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I489O... 5/18/2017 EXTERIOR RESEARCH& DESIGN, LLC. Certificate of Authorization#9503 . TRINITY ERD 353 CHRISTIAN STREET, UNIT#13 OXFORD,CT 06478 PHONE: (203)262-9245 FAX: (203)262-9243 EVALUATION REPORT Tarco Roofing Evaluation Report 30880.07.08-R8 One Information Way,Suite 225 FL30450-118 Little Rock,AR 72202 Date of Issuance:07/11/2008 Revision 8:04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: t Robert J.M. Nieminen,P.E. p;•.: The facsimile seal appearing was authorized by Robert Nieminen, %T•, ; ;.;: min Florida Registration No.59166,Florida DCA ANE1983 . ........ '��,• P.E.on 04/18/2016.This does not serve as an electronically,signed 9 o document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1507.2.3,1507.3.3,1507.5.3, Physical Properties ASTM D226 2006 1507.7.3,1507.8.3,1507.9.3 1507.2.3,1507.2.8,1507.4.5.1, Physical Properties ASTM D4869 2005 1507.4.5.2,1507.5.3,1507,5.3.2, 1507.7.3,1507.7.3.2,1507.8.3, 1507.8.3.2,1507.9.3,1507.9.3.2 1507.2.4,1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009 1507.7.3 1507.2.9.2 Physical Properties ASTM D3909 1997 1507.2.9.21 1507.3.3 Physical Properties ASTM D6380 2003 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS103 1995 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007 ERD(TST6049) FM 4474 T6460.06.07-R1 10/09/2007 ERD(TST6049) ASTM D1970 T30160.08.09 08/14/2009 ERD(TST6049) TAS103 T33190.08.10 08/06/2010 ERD(TST6049) ASTM D1970 T32530.08.10 08/17/2010 ERD(TST6049) FM 4474 T37610.07.11 06/29/2011 ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012 ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012 ERD(TST6049) TAS103 T35410.04.12 04/18/2012 ERD(TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 ERD(TST6049) Physical Properties T43930.09.13-R2 09/11/2013 ERD(TST6049) Physical Properties TAR-SC9480.15 07/02/2015 ERD(TST6049) Wind-FM4470/4474 TAR-SC5670.14 12/03/2015 ERD(TST6049) Wind-FM4470/4474 TAR-SC8020.14 12/03/2015 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004 PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005 PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004 PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006 Miami-Dade(CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013 Tarco Roofing Adhesive compound Affidavit 12/15/2015 UL,LLC.(QUA9625) Quality Assurance Service Confirmation Exp.10/13/2017 Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R8 Certificate of Authorization x9503 FL10450-Rg Revision 8:04/18/2016 Page 2 of 10 TRINITY ERD 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlayments: LeakBarrier Fast90*Self-adhering Tile Underlayment is an asphalt-saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self- adhering compound and release film. LeakBarrier MS300 Ice and Water Armor is a self-adhering, glass mat reinforced, mineral surfaced, SBS modified roof underlayment. LeakBarrier PS200HT Ice and Water Armor is a self-adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment. LeakBarrier PS200mu Ice and Water Armor is a self-adhering, glass mat reinforced, smooth poly film surfaced,SBS modified roof underlayment. LeakBarrier NR500HT is a self-adhering, plastic film surfaced,modified underlayment. LeakBarrier SS400 Ice and Water Armor is a self-adhering, fiberglass reinforced, smooth surfaced modified underlayment. 4.2 Mechanically Fastened Underlavments: Tarco 15 is an ASTM D226 Type I, 15 lb asphalt-saturated organic felt Tarco 30 is an ASTM D226 Type II, 30 lb asphalt-saturated organic felt Tarco NO 30 is an ASTM D4869 Type II asphalt-saturated organic felt LeakBarrier Easylay�is an asphalt-coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlavments: Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass-fiber-reinforced, asphalt-coated, granule surfaced underlayment used as a valley liner. ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt-saturated organic roll roofing sheet. LeakBarrier EasyMop'"SBS is a polyester reinforced,SBS modified bitumen roofing underlayment. 4.4 Mechanically Fastened Base Sheets: LeakBarrier EasyLay UDL 15 consists of a woven-polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi-ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven-polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi-ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven-polymeric scrim with a non-woven fabric on the top surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used as a base sheet in multi-ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118 Certificate of Authorization#9S03 F1.10450-118 Revision 8:04/18/2016 Page 3 of 10 TRINITY ERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop Tarco underlayments are follows: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles LeakBarrier Fast90 Yes Yes Yes No Yes Yes See 5.5.2 LeakBarrier MS300 Yes No No No Yes Yes LeakBarrierPS20OMT Yes Yes Yes Yes Yes Yes See 5.5.2 LeakBarrier PS200mu Yes No No Yes Yes Yes Yes LeakBarrier NR500"T Yes No No (No copper or Yes Yes zinc) LeakBarrier SS400 Yes No No No Yes Yes Yes Yes LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes multi-ply system) mufti-ply system) LeakBarrier EasyLay Yes Yes UDL 15,UDL Basic or Yes Yes Yes Yes (See FL16884) (as base sheet in (as base sheet in (See FL16884) (See FL16884) (See FL16884) UDL 50 mufti-ply system) multi-ply system) Tarco 15 Yes No No Yes Yes No Yes Yes Tarco 30 Yes (as base sheet in (as base sheet in Yes Yes Yes multi-ply system) multi-ply system) Tarco NO 30 Yes No No Yes Yes Yes (double layer) (double layer) (double layer) (double layer) Fiberglass Mineral Yes Surfaced Roll Roofing Valley Liner per No No No No No 1507.2.9.2(2) ASTM Organic Mineral Surface Tile Yes Yes Yes No Yes Yes Underlayment see 5.5.2 LeakBarrier EasyMop Yes SBS Yes Yes No Yes Yes See 5.5.2 5.5.1 Tarco 15,Tarco 30,Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrier self-adhering top layer or asphalt-applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam-On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332) applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-R8 Certificate of Authorization 09S03 FL10450-R8 Revision 8:04/18/2016 Page 4 of 10 r— TRINITY ERD 5.6 Allowable Substrates: 5.6.1 LeakBarrier self-adhering direct-bond to deck: ➢ New untreated plywood (unprimed or primed with ASTM D41 primer); Existing plywood (unprimed or primed with ASTM D41 primer); New or existing OSB(unprimed or primed with ASTM D41 primer); ➢ Structural concrete(unprimed or primed with ASTM D41 primer). Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OS8 sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Direct-Bond to Deck: ➢ ASTM D41 primed structural concrete. Note:Refer to 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the overlying roof cover is foam-on the roofing. 5.6.2 Bond to Mechanically Attached Base Sheet: LeakBarrier self-adhered to: ➢ ASTM D226,Type I or II felt; ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D226,Type I or II felt; ➢ ASTM D4601,Type 11 base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12). 5.6.3 LeakBarrier Self-Adhering Bond to Other Substrate Types: ➢ ASTM D41 primed metal(flashing metal,valley metal,etc.) 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-75.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AH1 Primer: (Optional)ASTM D41 Base Ply: (Optional)LeakBarrier PS200mu,self-adhered. Underlayment: LeakBarrier PS200"T,self-adhered. 5.6.4.2 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional)ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R8 Certificate of Authorization#9503 FL10450-R8 Revision 8:04/18/2016 Page 5 of 10 TRINITY ERD 5.6.4.3 Maximum Design Pressure=-217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of AHJ. • Primer: (Optional)ASTM D41 Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. S.6.4.4 All other direct-deck, adhered Tarco underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. 5.6.4.5 Maximum Design Pressure=-45.0 psf": Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50(48"wide rolls);See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6"o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. 5.6.4.6 Maximum Design Pressure=-60.0 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7"o.c.at the 4-inch wide side laps and 7"o.c.at three(3)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. 5.6.4.7 Maximum Design Pressure=-60.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50(48"wide rolls);See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6"o.c.at the 4-inch wide side laps and 6"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. 5.6.4.8 Maximum Design Pressure=-82.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8"o.c.at the 4-inch wide side laps and 8"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. 5.6.4.9 Maximum Design Pressure=-120.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200Mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118 Certificate Of Authorizotion x9S03 FL10450-R8 Revision 8:04/18/2016 Page 6 of 10