HomeMy WebLinkAboutInspection Docs j f� elm WO MI Windows LDoors Phdm (8001 876-0643 i 650 West MMet St. .:. Gr.-a#z :. PA 17030 Series 185 Aluminum Windows Insulated 420 Series Aluminum SGD Insulated Glass - RLE5527 Tempered Glass HPLOE 11 0.54 0.25- 0.55 0.25 ill. .. MOM 0 1 a" . 0.44 < = 0.3 0.47 ; :" lovWx T. . . e�+a�sAaa�r� >9�� ; :•nar�ma�wtiyds�• da l5ceds r3�o:��opt�aeps i;�iadAb pa�luct arR awt 'iot 0 Professional Insulators of South Florida FTC Insulation Installation Certificate To: St Lucie Couny Date: August 17 2017 Re: Lot/Block- Address: 15 San Juan Project: The undersigned hereby certifies that insulation has been installed iva the above described property as follows: x. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil hock Wool Blankets Density: X Aluminum Foil R-Value: R 4.1 Rigid Board Polystyrene j Other 2. Ceilings(level)have been insulated with: Spray-on Cellulose Thickness in Wches: I.l" X Fiberglass Blown Manufacturer: Climatepro Rock Wool Blankets Density: Aluminum Foil R-Value: R 30 Polyurethane O en Cell SPF Ceilings(Inaccessible)insulated with: Spray-on Cellulose Thickness in inches: 9.5" X Fiberglass Blankets Manufacturer: Johns Manville Ignition Barrier Density: Fiberglass Blown R-Value: 12 30 Cellulose Loose Fill I Open Cell SPF 3. Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R Value: lCellulose Loose FBI Open Cell SPF 4. Garage partition walls of A/C living area have X Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: 3.5" Polyurethane Manufacturer: Johns Manville Spray-on Cellulose Density: Open Cell SPF R-Value: R-11 5. The following have been insulated: e`6•i�.�r�n,,, , �� ,04.1#40. klPltlVm B I LAING CORP. General Contract/Builder mmomp CBC1254041Competency# Professional Insulators of South Florida Inc. ��' �, ,e•�A .Insulation Contractor By: By: RECEIVED OCT 3 0 2017 899-d L000/ 000d 998-1 999L8LRLL da o0 Su i p l i n8 euuAM -WOdJ 2:0 L L L 0£-0 L P!anni g':8f�`D+eveiapmle>nt Services BuYtdin'g`9 b6d.tbibuaation Division 2300 le j nia Ave Ford-Pierce;•FL 349•82 772-462-1165 Fax 772-462-6441 Request for 304my T;emo6lry'Pdwerkdease I Dam: lserrriilr'iVurnber: � Pied Address: O rJ �)CLCN_ V a I THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY,FOR A PERIOD NOT TO.EXCEED THIRTY(.30) RAYS, FOR THE PURPOSE OF-TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR A:FINAL INSPECTION. 'IN CONSIDLRATION OF APPROVAL OF THE WOUEST WE HEREBY ACKNOV M43E AND AGKEE AS FOLLOWS: I / I. Ziais temporary.power release is requested fb r tl't2 above sad purpose only,and there vofl be,no occupancy of any type,other than that permitted by construction during this time period. 2. As witness by our signatures,we hereby agree to abide by all terms and conditions of this agreement, Including Building Division.Policy,which-is incorporated herein by reference, 3. All conditions'and requirements listed.in tfie attached'document entitled"Requirements for 30.Day Power'for Testing"have'been fulfilled and the premise is ready for compliance inspection. 4_ All requests for-an extension beyond 30 days must be-made in writing to the Building Official swting the reason for the request. Polder may be'rerhoved•from.the site and/or.a Stop Work Order issued if j the Final Inspection has not been approved within 30 days. A fie of$100.00 will be required to lift the Stop work Order. WE HEREBY RELEASE-AND AGREE.TO.HOLD HARML :SS,.ST. LUCIE COUNTY,AND THEIR EMPLOYEES FROM ALL LIA1314 IES AND CLAIMS OF ANY(YPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS.TRANSACTION,INCLUDING ANY DAMAGE;•WHICH-MAY BE INCURRED DUE TO THE DISCONNECnON'OF ELEC MICAL POWER IN THE EVENT OF VIOLATION OF THIS•` 'GREEMENT \ n OWNER SIGNATURE DATE BEN, CONTiZALT�R i•1 DATE ELECTRICAL cowmACTOR SIGNATURE DATE RECEIVED SEP 19-2017 9000/�OOOd 999-1 999L8LKLL da o0 su i p i n9 auu�C�ry -WOdd �0:60 L[, 6 L-60 Planning &Development Services Building &Code Regulation Division i p 2300 Virginia Ave e o Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 i CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT ]PERMIT #: I 'LZ - 0117 JOB ADDRESS: /5 Saki (-I�wg.yn !BUILDER/CONTRACTOR: GZday\e)y W a I1 Con��P ;PEST CONTROL CONTRACTOR: EVICT-A- UG TERMITE&PEST CONTROL INC. ;PEST CONTROL LICENSE #: J13175775 i We, the undersigned, hereby certify that we have pretreated the above described construction for I termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: Chemicals used: BASELINE ercentage of solution: •06% Total gallons used: Date of Treatment: C4 IJ 1 Time of Treatment: Z' Footing -_- _ -` _ Slab 1st Treatment 1st Treatment i Re-Treat Re-Treat i Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other Perimeter for Final Inspection 1st Treatment lrl��--, -// Re-Treat Signature of Exterminator Date Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fall and a re-Inspection e charged. f 3C104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each.required protective treatment Is completed, providing a copy for the person the permit Is Issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, Identity of the applicator, time and date of the treatment,site location, area heated, chemical used,percent concentration and number ofgallons used, to establish a verifiable record of protective treatment. If the soil chemlcal barrier method for termite prevention is used,final exterior treatment shall be completed prior to final bullding approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing ail the treatments and dates of applications. Revised 7/24/2014 it KELLER, SCHLEICHER & MaCWILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www�ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED March 30, 2017 KSM JOB# : 170973-1d/MH/cc PERMIT# 1702-0187 CONTRACTOR Wynne Development JOB LOCATION 15 San Juan Spanish Lakes 1 Port St. Lucie, Florida i ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.W. 0" - 12" 50 108.4 109.5 99.0 2. N.W. 50 104.9 95.8 3. Center 50 108.5 99.1 4. S.E. 50 105.7 96.5 5. N.E. 50 107.1 IT 97.8 Soil Description: Brown Sand 111.0 1 I I I I I I W In Place Moisture: E I I I I I I I 10.8 Percent G110.0 i _.j.—..i..—.. ..—.j—.._i.—.. ..—.. Optimum Moisture: H 11.0 Percent I I I I I I T I I I I I I 109.0 —:.—..� —..L..— --..—..y..—.. Max. Dry Density: P I I I I I 109.5 P.C.F. I I I I I I I @ Test Locations The C 108.0 --------- Density �& Penetrometer F I I I I I Readings Indicate the I I I I I I I Degree of Compaction Meets 107.0 —•.•—•. I — I — I— —I — I — Minimurj�Rggyird D I I I I I I I for , �u� trip. R I I I I 1 I I �d,�l�' • , ,#o Natural Grade. Y 106.0 — I._•• I,._.. I _ I_•._I.._.- I es, c 11y ;e�1: 8 9 10 11 12 13 14 15 4 ' Moisture-% of Dry Weight b .fiColl Qqe County Building Department RECEIVED APR' 4 2017 Er> I !"• lakes.com Ronald G. Keller, RE.:37293/SI Lic. No.:860 / Julie E. Keller, P.E.:68366 B ,?►DEN BRAQEN;A 'I'. A., P. A. r U( n^ t C- frchr'ec s & nl lannem .n fey 497 COCONUI''�VENUE, STUART, FLOR10A 3499B TELEPHONE: (772) 2B7-B258 FAX(772) 2B7-B2B3 #AAC-000032 St. Lucie County Building Department 2-28-17 To whom it may concern, Please note, the plan review revisions requested for the 22 permits stated below shall. be resubmitted to the building department within 30 days from the time they are issued and prior to any frame-all inspection. We have discussed this with General Contractor and they are in agreement the this. • 2 Universidad — 1701-0377 • 2 Barcelona— 1701-0505 15 San Juan — 1702-0187 • 8 Grande Vista — 1701-0378 • 3 Barcelona — 1701-0513 • 78 Ipanema — 1702-0186 • 124 Mediterranean North — • 4 Barcelona — 1701-0511 • 183 Calle De Lagos— 1702- 1701-0374 • 5 Barcelona— 1701-0506 0184 • 54 1panema — 1701-0371 • 6 Barcelona — 1701-0508 • 14252 Avestruz— 1702-0199 • 6572 Zapote— 1701-0376 • 40 Silver Oak Dr. — 1702- • 7 Florida Way— 1702-0189 • 6639 Yedra — 1701-0375 0188 • 5 La Villa Way— 1702-0196 • 8 Montoya — 1701-0372 • 19 El Camino Real — 1702- -• 6794 Sinsonte— 1702-0205 0 1 Barcelona — 1701-0512 0195 If you have any questions please feel free to call the me at our office 772-287-8258. Sin e an' I R, Braden AIA Br en and Braden AIA PA