HomeMy WebLinkAboutbuilding plans 2\n 0
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
Woo d screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank malls
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete
block construction
u
i�
12
SLOPE 4
COVERED
PORCH
--------------------
5/8" thick x 8"w cut Finish Columns with
coral finished stucco bands
RIGHT ELE\/ATION Y 5/8" thick cut coral
finished stucco bands
12
4 SLOPE
12'
l.H
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin cape and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet , _ _
BGRESSII
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlayment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced C o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12" 2„
O.H. .H.
7 ..
O'-O" Finished Floor
ELE\/ATION NOTES:
- Overhangs at 1'-0" unless otherwise noted on Roof fi Ian
- Roof pitch at 4:12 unless otherwise noted
- Ang changes to this plan shall be submitted to the architect
for approval in uJriting prior to starting construction.
- Return ALL Stucco Bands Into Window or Door.
I i
0'-0" = Finished Floor ----------- - - ------------ - - - - -- -- ---------------
CAP (Als a-
5/8" thick light textured
LEFT ELE\/ATION stucco on typical concrete
block construction
SCALE: 1/4' = 1'-0'
Product Approval Submittal Affidavit
Opening
Schedule Swing Doors,
Overhead Doore.
SlidDoors.
Manufacturer
Mi Windows
and doors
DAB
Windows dt Skylights
Glass
Attachment method
Ezspiration
Date
Design Pressure
of Approved Tests
Opening
Type
NOA/FL
NUMBER
Product
Model ii
IEE, x gpc x. WW nirl. CC n t1on at meeXX
rem each caner end i o.c. thereaftar throilgT� T Buck into eolid
food Cpr wall moprovang min 2.5' edge distance in atnct edharencs
to the roduct approval.
a :s hgrxvr . Camp 3/9 i a' Hla HLC awseva enchxa eta d 0011 With
h tss d�a eaaha a girth as T shis distance. Instal � track to buck
p fl) 5/ii• : 5/a' r'M thread ley .emu m cash racket mmntwning
sa d 1.6' edge 6atenee - 6C w newy adhare to product approval
rov'.dI VIC usher an rdler atw
± 60 psf
+ 50.0/-60.0 sf
P
12.3
A
FL# 11499.2
16-0330.02
Single Hun
9 9
Overhead
Garage Door
Series 185
Model 824/811
9'-4' max. width
16'-O" max height
10-9-21
B
FL# 16614.1
Fiberglass
Design Smooth Pro
Jeld-Wen
Elcc 1/1' dia. tapcon with min 1.25" embedment at 3" max
from corners and 1.5' o.c. max thereafter in head and jambs.
+ 50.0 PSF
C
FL# 15332.2
Sliding GIS6a
9
Door
Series 420
MI Windows
and doors
q� x �{p cons enotrema et max.
roe each caner and l o.c. ale raw t�ereaPter Lhroug
PT Buck Into slid figsd CHU wall maintaining min 2.5' edge istance
in auict adherence to the praeluct approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model IIIManufacturer
Attachment Method
E � TEST
Date
Design Pressure
of Approved Teats
Mullions
FL# 15353.8
CM-18631
vertical mullion
Mi Windows
and doors
For CMU use (D I/4" x 2 3/4' tepeons with min I I/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
selF tapping screws per clip as shown in product approval.
+ 118.9 PSF
_
Roof
FLU 11651.12
5V Crimp
p
Metal Roofing
Gulf Coast Supply
and manuf aeturtng
26ga. BY cnwp metal roding attached to plywood deck using tt4 x 1.5"
mood scram with self sealing washer at 12' o.c. max aganng over ASTM D
(tgpe 2) 30 Ib felt underlagment installed with min. 4 side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?paced L o.c. at all laps and two stagggered roue 12' o.c. in field. Attach
deck to trusses using attachment detal m roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
Vingl Soffit
Kaycan
Install using 2' x 2" battens at 6" o.c. screwed to soffit framing using
48 x 3' wood screws at each truss. Install soffit to battens using
e
+55.0/-35.0 PSF
Hurricane 24 Gauge Global Protection Install using 1/2' dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
Fin 15014.2 Products LLC long SS screw head combo. with Neoprene washer at 12 1/2' o.c. ± 45.0 PSF
Panels Storm Panels along the bottom and IS" o.c. at the top
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
5/8" thick x 8"w cut /
coral finished stucco bands
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" o.c.
base -board II II / 211 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6"x4" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
nts
12
4 SLOPE_
COVERED
PORCH
5/8" thick light textured
stucco on typical concrete
block construction
REAR ELE\/ATION
12
SLOPE 4
FE
F -1
File Copy
TERMITE TREATMENT RE
CONCEALED FASTENERS OR ATTAI
ARE THE RESPONSIBILITY OF
CONTRACTOR OF RECOR
ALL MANUFACTURES LAI
U FACTORS AND SHGC
WITH FBC ENERGY C
REMAIN ON ALL DOORS.
File Copy
TERMITE TREATMENT RE
CONCEALED FASTENERS OR ATTAI
ARE THE RESPONSIBILITY OF
CONTRACTOR OF RECOR
ALL MANUFACTURES LAI
U FACTORS AND SHGC
WITH FBC ENERGY C
REMAIN ON ALL DOORS.
,.
pk
r.
ti
•
i"�
li
�''4r
t MY
.
dint
.t
t
Y%�
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0'
-1 HESE pLANS AND ALL F
ARE SUBJECT T4 ANY
REQUIRED BY FIELD IN
." MAY:BFa NECESGARI
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x I.5"
wood screws with self se6ng washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end 11��'
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails u r,n*J�1
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach [ y,1,ttCIF ) FORrolJ T V ill
eck to trussea using attachment detal on this sheet >11VVIVNN eD gpg�t VLI."'et.d
a
FRONT ELE\/ATION
1)ATr L 0
pi.ANS AND PER2.IIT •1lJSI' BE
LN51,EC110N \Y1LL DL ^
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using Sd nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
SCALE: 1/4' = 1'-0'
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Buildiri Design is; Enclosed Risk Category: II Wind Velocity: 145 mph ultimate
Mean Roof Hill il�'-pp" Roof Pitch. 4:12
Internal Presswe Coefficient: ±0.18
SubJectabihty to damage from: Weathering: Negligible Termites: Veru Hal
Width of Roof End Zone: 3'-4" Wind Speed: 145 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.12L
Adjustment factor for Exposure Height: ASO design
Load Combinatim: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LLOL
Components f. cladding Wind Pressure (NET) Roof Zone: I. +20.4/-32.4 par
Roof Zone: 2. +20.6/-51.0 par
Roof Zone: 3. +20.6/-84.0 psf
Components 4 Cladding Wall End Zone Width.
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 per
Wall Zone: 5. +35.8/-41.8 par
Components 4 Cladding Wind Pressure (NET) on Garage Door. +32.0/-40.3oaf
Shear Walls Considered for Structure? Yes
Continuous Loac Path Provided? es
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure:2,500 pat, Presumptive: X By Test: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: psf FLOOR DEAD LOAD: IO paf
JOB ,ADDRESS: ��O ';'\X'-" e<
TO C I20PITCH
= Roof Zone I
Walla Zone 4
= Roof Zone 2
Walla Zone 5
END ZONE
Corner Zones
Roof Zone 3
Braden It Braden AIA, FA
Wynne Building Corp.
Model:
Date Drawn
Revisions :
Sheet
Comm #
Architects - Planners
41l S.E. Coconut Avenue
I I
THE leU I N D S O R
REAR
4-25-F6
Drawn t)y,
10-18-I; Product
Approval Revision
4-4-I� Plan Review
1
-Irj
Tel : (112) 281-8258
PORCH
C.C.LI.
Fax : (112) 287-8283
Spanish Lakes
RIGHT
Checked b y
E-mail: bradenaiaOcomcast.net
St. Lucie County Florida
D.R.B.
OP 5
Stuart. FL 34996 #AAC000032-110
WOhi
ONS
THAT
©DES.`
JO--
FLOOR
Recess op plate
Ow x 3/8"d
Counter top - verify type
with contractor
steel, support
g
�3
CRASH i"OST DETAIL
see detail othis
sheet
h
TYPICAL
NOTES: SCALE 1/4" = 1'-O"
N.T.S.
I.
Contractor to verify ALL notes and dimensions prior to
3L" high bg 4" diameter
pproceeding with Work.
g
steel crash post. Floor
Flange with 4 - 3/8"
Steel countertop support angle
Install L" from each end and
Base cabinet
2.
Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts into
one in center of
counter.
3.
ALL Lumber to be used as Beam, Rafters, etc... to have
slab (3/8't 50 kw steel plate)
see angle detail
e"
a minimum 1,400 F.S.I. fiber stress.
61.
I/2" drywall
wood studs
IL" o.c.
at at x
4.
No dissimilar metals to touch.
:2 2'/,"
2" x 8" PT wood plate
5.
ALL Concrete used for slabs shall be min. 2,500 PSi concrete.
;
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3 000 P S 1 concrete and/or 4 000 P S I grout mix
o
6. Drywall at ceilings shall be leveled and attached to bottom chord
a su
z'r,
KITCHEN ISLAND FRAMING DETAIL
of trusses with screws per FBC R-102.3.SJ.
2%,"
Attach buck to block wall with
1/4" din. Elco
7. ALL Wood In contact with concrete shall be pressure treated.
O O
conc screws with min.
1 1/4" penetration at 12" o.c. max
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
y;,
and -4 max from each corner thru
2" L" PT Buck
Exterior face x
or wall
9, ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at Water heater in accordance
sties
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
48 wood screws thru jamb into buck
handicap accessibility requirements.
2'''
si;'
Detail at Door pt each dings and max and
riot to door attachment
��"
12. Lowest finished floor to be set bg Governing Building Department
L'"
;,
NTS
surveyor t0 set In field.
13. Separation between residence and garage shall be per FBC R302.6
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
1-4. Door between garage and residence shall be 1-3/'4"t 20 min, rated door
NIST BLOCK LATIONRIOR TO BUCK
Water Heater
Install windows thru buck into
block with 3/I4" tap -con with
1 1/2" penetration at L" o.c. max.
IS- Wall and Ceilingshall have a flame -spread classification of not greater than 200 per FBC R302.9-1
p
from each corner and 20." o.c. max
thereafter 20"
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
at jambs and o.c. max.
Exterior face at head and sill per product approval
I-1 All d tt n Intlo n materials Installed on attic floors shall have a critical radiant
of wall Buck to be 1" x 4" PT
expose Ic I
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation "Varies
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R31� - see permit info box of code edition
18. Gypsum board material shall conform to ASTM G36, C-i9, C4-15, C514, C630, C931 1"xV P.T. Buck nailed to
C60, C1002, C1047,C1171, CII18, C12�f8, C1395, or C139(o and shall be installed
a t l U I fl Cl OW S lock with case hardened nails
D e t a i l according to the following: (FBC R102.3.5) Masonry Beam Prior to window attachment
I" x 6" P.T. Buck nailed to / NTS
block with case hardened nails
prior to door attachment.
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
Installation of drybwall Into
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, AGJ and A13-1.1
20. Cement, fiber -cement or glass mat g psum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316-
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #1165IJ2
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x LV"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6' end
laps fastened with corrosion resistant tin caps and with 1.25" ring sfiank Halls
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails
( 24" o.c.) supporting Max.
18101bs. uplift
12
4 F-
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings bg manufacturer)
Aluminum Drip \R-30 blown fiberglass
Edge E Fascia In bottom chord of trusses
I/2" drywall with smooth finish
2" x 6" Sub -Fascia Two rows of beam block filled with concrete
and (U #5 bar cont. in each row. Substitute
Kaycan full o vent vingl soffit installed precast lintel filled with concrete and (1) #S
using 1/8" die shank x 1.5' long gaiv. bar cont. For bottom row over openings
roofing nails with 3/8" dia. head per
product approval - see chart sheet #I 1/2" drywall over I" x furrin
strips at 14" o.c, with R4.1 PI -foil
insulation on typical 8" Block walls
5/8" thick light textured - All drywall to be installed per FBC R102.3.1
stucco on typical concrete T and shall meet all pertaining ASTM codes.
block construction Mortar to be Type "M" onlg proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar w/
30" overlaperlap Fill cell with concrete and
at each filled cell (I) #5 bar vent. (tgpicaU.
Max, spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
411x6" #10/10 WWM on L and Visqueen over
clean compacted termite treated Fill
Grade _
_- . IIII IIII-IIII =IIII
=1
14" x 14" Concrete footing
14" with (2) #5 pars cont, and #5
T Y F` I C A L S E C T I O N transverse bars at 48" o.c.
Scale : 1/2" = I'-O"
/ Install SGD thru buck into
block with 3/16" tap -con with
11/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
O O Use 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
I" x L" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
n Masonry Wall -
1
Bottom Track Typical Flooring
cJ Ill Install SGD thru buck into
block with 3/16" tap -con with
S l l d i n g Door D t a 1 l 1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c, max
At Masonry Wall NTS thereafter at Jambs per product approval Jamb
Window SCHedule
Mark
Size
Rou h OiDen.
Window Description
PRESSURE ZONE
I.
4'-5%"X 4'-4 %8"
54%"x 54Ya"
Single Hung
ZONE 4
2.
4'-2Ya'x 5'-3 %'
15" x 43 %4"
Single Hung
ZONE 4
3.
2'-2" x V-2i2"
21Y,"x 38%"
Single Hung
ZONE 4
4.
V-1" x V-3%"
38" x L3'/4"
Single Hung
ZONE 4
ALL Windows to be aluminum Windows w/ tint
nd mullions per elevations.
LL windows to withstand pressures in permit info box on sheet I
LL windows in bathrooms to be tempered
Al rough opening dimensions to be verified by contractor
wi h manufacturer s specs prior to construction
Door ScHedule
M
rk
Size
Rough Opening
Door Description
PRESSURE ZONE
9'-0" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
3'-0" X c-8"
41014" x 83%4"
Fiberglass Panel - Inswing
ZONE 4
L'-O" X 6'-8"
14" x BI %;' ;f; ;at
...
Sliding Glass Door
ZONE 4
2'-O" X C-8"
Solid Core - Wood - 6-Panel-BrFold Finished 24" x 81'/2'
2'-16" X 6'-8"
Solid Core - Wood - L-Panel
5'-0" X 4'-8"
Solid Core - Wood - L-Panel - Bi-Fold
2'-8" x C-8" x 1 %"
Solid Core Wood, Steel, or Masonite Door
2'-8" X C-8"
Solid Core - Wood - 6-Penal
2'-v X L'-8"
Solid Core - Wood - L-Panel - Bi-Fold
ALL
b
GARAGE
WITHSTAND
A
wi
Exterior doors to withstand pressures stated in permit info
x on sheet 41
DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
rough ope Inino dimensions to be verified bg contractor
h manufacturer s specs prior to construction
12"
Verify attachment
hole location with GC
prior to fabrication
3/8" thick
steel break
Z
H.B.
O
W
W
0.
F
W
F
01
12° 8'-I0Y2" "
Y2"
0o ao 00
0
0
EGRESS
0
Filled cell under P O R
C H
-
girder above
WIRE LATH
& STUCCO
CEILING
19'-91,
o
Ear
V
MASTER
BEDROOM
o
c
0
Flat Ceiling
I
I
�
Vanity to be O
I
O
34 Y2"high
_
Rod &Shelf r11111ii-8'-O" tol9'-8" A.F.F.
Vaulted
Ceding
i.n
IN
GREAT'
ROOM
J m
LOlitS T
i�
i
o
H
Rod Shelf
I
r
a a.c A
to -
32" DRYER ASHER
v 9' 5" ° LAUNDRY
I
O
� �
I
N
8'-O" to T-8" A,F.F,
O
H
r
I
Vaulted Ceiling
DINING
Vanity to
34 Y2„high
be
I
ROOM
8" 42°
I
I -
n
E
1
tr
counter tops to
overhang wall "S"9'-5"
3/8" thick steel
O
5'-3"
901,I
leq.
counter top supports
eq, coup er tops
to
over anq wall
1.5"
Ln
m
SECOND
q BEDROOM
rlII1b8'-C" A.F.F. O
Flat Ceiling r F
r �
12'- 8"
®� THIRD
BEDROOMm
Q
O
r
=
8'-0" A.F.F. n
A/C
Flat Ceiling If
�r
O
�
cn
R-II Betts Insulation Provide auto
closer
ISO Amp
D
Panel
3.
i+)
i
r----------------- i\
I I
I I
I I
�
I
°
I
GOLF CART
(17
GARAGE
L"
COUNTER TOP BRACKET DETAIL
+41" high wall
KITCHENto_ •
extend over Ref
I 1 " _"
:;:..r.^, ins....•rrnsfro.....•rocsssr.•rn,.rssrr.•
R-11 Sat.
4"cl) Steel Ballard
See detail on this
Attic Access
V with light_
jF
0
O '
j r
r •
in
%IFlat Ceiling
I� O
Block wall 1nz0
MT F)Q garagge to be
2' 8„ Q�atruck block
13'-0"
IERGENCY
EGRESS r------------- ---�
I I
I I
I I
I i
I I
i I
I I
I I
I I
I I
I 1
I i
�❑O�D O�DD������U Down
• • Q
O
H.B.
s-
in
Square Footage Breakdown
Total A/C Space = 1,153 sq. ft.
Covered Porch Total = 2-12 sq. ft.
Garage = 4r;
Under Roof Total = 2,484 sq. ft.
File Copy
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = #8 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws based on pressure for root' stated
in permit info box on these plans for zone 3
Ke
Area
Ede
Field
Fastener
Pressur
Zone 1
6"
6"
ed ring shank
45 psf
Zone 2
4"
C
8d ring shank
% psf
Zone 3
4"
q "
8d ring shank
84 psf
** Zone 3a
6"
611
1:8 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Provide 45 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel.
Provide Cast -Crete
BUS-OB/OT precast -
lintel set in mortar
Min. 8" Bearing = ---
Verify with Plan
Concrete 12"x 12"
/ Lintel �—� Column Block
#1
7 Rebar
Rebar -48 Bar Dia.
Min. Overlap
Column to Llnt1 Attachm&nt
NTS
Provide 95 bar set in pre -cast R C C F f= L /4 `t Scale : 1/2" = 1'-0"
lintel into beam where length or
the opening calla for it.
on
ovide PT Buck
.ached per iamb
all$ into filled c
4" Pre -cast
Sill (
— Overhangs at 1 —O unless otherwfse noted on
— Roof pitch at 4:12 unless otherwise noted on
— Truss shop drawings to be provided bg manufa(
=
— Any changes to this plan shall be submitted t(
architect for approval
In Writing prior to Start
— ALL TRUSS TO TRUSS CONNECTIONS E
TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prlc
to construction for layout and uplift verlflcatto
Poured Filled Cell
— Contractor to provide for Form Board Surve(
Form Board Survey to Truss Company prior ti
de #5 bars with min. 48 bar
.ers overlap in filled cell. Tie
cell steel into continuous
• steel.
CBS WALL Scale: 1/2" = I'—o"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vart. leg of
truss with IOd x 1.5 nails at 4" o.c.
Install Simpson MGT into wall using
r' 5/8' dia. threaded rod set min. 12"
nto wet beam and (22) IOd nails into truss
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
AT CENTER BEARING POINT
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer or
ASTM D Tgpe 2 felt paper using Sd nails. Substrate
to be 19/32' CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c, in field. Attach
deck to trusses using attachment detail on this sheet
le Additional Precast Lintel
45 bars
Lintel
Bar
Clear
"A"
"B"
`�
Length
Length
Span
Bars
Bars
r",".`.9 r` •i`''.`alcLEAR
2'-10"
2'-8"
none
i I •� i
3'-6"
3'-4"
2'-2"
2,#3
none
BFB-OBAT 8F8-IB/IT BF8-IB/2T
Additional
4'-0"
3'-10"
2'-81,
2.#3
none
- #5 bars
CLEA '`A�,
4116"
4'-4"
a`2
none
•`. = One Row of "H"
5'-4"
5'-2"
4'-O"
2,tt3
none
J';ap:`:
Block Above
none
r ; Precast Lintel r' I
none
ti,
Additional `+'. i-4"
y ----" #5 bars
1`
7'-O"
6'-2"
2,#5
none
BFIL-IBAT BFI4-6/21'
2,45
none
NOTES:
ALL reinforcing steel is grade 60.
I. min. coverage of steel-I.5"
2. mm. bearing required a ea. end=8"
3. standard for remf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
Bottom
Steel
Size
Top
Steel
S1Ze
Max.
Gravity
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
T-2"
V-L"
BPS-OB/IT
1
#5
3049
1569
1024
L31
2'-0
4'-0"
BF8-OBAT
1
45
2561
130
11,43
L45
4'-5"
V-10'
BPS-OBAT
1
#5
1105
1 909
339
L50
V-O"
C-L"
BF8-OB/IT
1
#5
1238
835
121
L60
6'-8"
T-V
8F8-OB/IT
I
#5
1011
121
534
L80
8'-0"
'1
SF8-6/21'
1
#5
2
95
152
591
512
L90
9'-0"
10'-L"
8F8-I13/2T
1
#5
2
#5
443
530
401
L90B
9'-0"
10'-L"
BFI6-I8/271'
ONE
1
#5
2
95
1533
1183
401
1_I00
10'-0'
ll'-4"
BF8-IB/2T
1
#5
2
#5
582
494
452
LIOOB
10'-O" 1
11'-4"
BFI6-8/2T
ONE I
1
#5 1
2 1
#5
13LL
1 1028
452
L120
12'-0"
13'-4"
BF8-6/21'
1
#5
2
95
411
428
324
L120B
12'-O"
13'-4"
BFI6-IB/2T
ONE
1
#5
2
#5
1015
110
324
1.140
14'-O"
IS'-4"
BFI4-8/21'
ONE
1
45
2
45
1250
609
259
L160
16'-O"
IT-4"
8F8-IB/2T
I
#5
2
#5
300
142
194
LIOOB
I6'-0"
IT-4" I
BFI4-6/217
ONE
1
#5
2
#5
950
soo
1.14
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION IREGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE L-OAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED,
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2' nails -
( 24" o.c.) supporting Max.
18101be. uplift
Aluminum Drip
Edge t Fascia
12"
2" x 6" Sub-Fascl
Kali full o vent vingl soffit installed
using 1/8' dia shank x 1.5' long galv.
roofing nails with 3/8' dia. head per
product approval -see chart sheet #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vent. tied_ —
into lintels above
thicken edge to SW"
with concrete and
one #5 bar continuous
BEYOND
Top of footer
I6" below finished floor
V
—IIII IIII '
12
4 �—
1/2"
atta
framl
no li
Aluminum Drip -
Edge t Fascia
Poured
concrete
Poured Cori
concrete bloc)
Concret<
Manuract]
3
4Iumnum Panel
imes per manufacturer
See 7Ltucal Sea Date]
1/8' x 3/aT Wing Nut w/
appropriate washer and spacing
per manufacturer's Details
I
Stud Detail
St"d w/ Die Cast Zinc ]
Nickel Plated Wing Nut
Flush Mounted Shutter Detail
nts
Flash and Counter -'
flash
Nail ledger to
gable end truss
with (2) lod I
at each web
]ck stucco on 3/8" hi —rib lath
d to horizontal and vertical wood
with nails or staples to provide
than 1-3/4" penetration into
al wood framing end 3/4' penetration
rtical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
95 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step
per
foundation
plan -
a Slope
per
foundation
plan
Wood
Brace Gable end
with 2" x 4" SYP 42
Slit back nailed to bottom
or top chords using (2) IOc
nails at each truss
PRE-ENGINEERED W
® 24"o.c. TYPO
( shop drawings by mar
" \R-30 blown fiberglass
in bottom chord of trusses
/2" drgwall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitut
precast lintel filled with concrete and (l) #5
bar cont. for bottom row over openings
1/2" drywall over I" x furringg
strips at 14" o,c. with R4.1 frfoll
insulation on tgplcal 8" Block walls
All drywalto be installed per FBC RIC
and shall Peet all pertaining ASTM codes
4 Mortar to be Type "M" only proportioned
and Mortar joints shall comply with FBC
Provide Dur-O-Rock at all wet areas (e
Fill cell wnh concrete and
(l) #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
4"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
f'CI IT-1 11 1114 ] —FI
T IIII—
i i ] i-\
3 �-p al Section at Front Forch
Braden t
Braden AIA, FA
Coconutvenue
:-
Stuart, FL
34994 __ •��•
Simpson HETA 20 Strap truss to wall using Simpson MGT with
hurricane anchor at each truss 6/8' dia. threaded rod with min 12" embedment
/ 1A11 — — N_ __. __ _ nw _ Into hPAm Pit kPr min+ eP4 L
W_ralne Building Corp.
Spanish Lakes
St. Lucte County Florida
nurricane ancnor at each truss
( 24" o.c.) supporting Max,
1810 lbs. Uplift
MODEL:
REAR
PORCH
RIGHT
Provide downspout
Date Drawn Revisions : Sheet Comm 4
4-25—I4 10-18-16 Product
Drawn by: Approval Revision
C.C.U. Plan review
Checked by:
D.R.B. OF 5
Re -010
AN
1
FA
File Copy
PANEL "A"
Poles
BR I
Load
Will
Description
cw
arott
Description
Wire
Load
BR
Poles
2
40
1.0 kw
us
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
tt10
40 gal. water HTR
5
6
Range
ttL
12.0 kw
50
2
1
e
1
20
1.8 kw
#12
Pump
9
10
Dryer
#10
5.0 kw
30
2
II
12
1
20
1.5 kw
412
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
412
Microwave
IS
16
Refrigerator
912
1.2 kw
20
1
I
20
1.5 kw
tt12
Kitchen S.A.C.
n
IB
Recepts
tt12
20
1
I
20
1.5 kw
412
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
I
20
0.81 kw
412
Garage Door Opener
23
24
TRecpts
#12
20
1
1
20
1.4 kw
#12
25
26
1 Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
I
IS
#14
General Lighting
29
30
Recepts
#12
20
1
1
15
#14
General Lighting
3l
32
Recepts
#12
20
1
1
15
-
414
General Lighting
33
34
Exterior GFCI
#12
20
1
1
15
414
General Lighting
35
36
Bathroom GFI
u12
20
1
-
1
20
#12
smoke Detectors
31
38
General Lighting
ttN
IS
I
1
20
#12
Bathroom GPI
39
40
General Lighting
ttN
--
15
1
s are
41
42
1 s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Ot .
Watts
Total(Watts)
.general Lighting ,(3. watts .aq.. ft.) ... .... . .. . . . .. . ..
Small_ ,A,ppllance. C.ircuit(s) . . .... ... ..... ... . ......... ...
Range
Refrigerator ..
Microwave
.................................................................
Dish Washer
.................................................................
Clothes..Washer...............................................
Clothes, .Dryer ................................................
Water Heater .................................................
Water. Pump ...................................................
Garage. Door. Opener ...... ..............................
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1500
1,500
1
1200
1200
1
1.200
1,200
1
5,000
5,000
1
4,500
4.500
1
1,800
1,800
1
810
810
Total Watts
31415
First 10000 Watts e100%
1
10,000
10,000
Remainder 21,4i5 e40%
1
O
10,944
Electric Heat or A/C 10,000 e65%
1
10,000
10,000
Calculated Load
Watts
90,944
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 1 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
$
ISingle Pole Switch
®
Recessed Can Light
S,
Double Pole Switch
®
Eyeball Recessed
Pe
Push Button Switch
-CrExhaust
Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
F1
Waterproof, ground fault mterrupte
K
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
cn I
Carbon Monoxide Detector
Flood Light
TQ
Thermostat
m
Electrical Panel
®
Central Vac
rc::3i
Electrical Meter
®
Smoke Detector
Ceiling fan
®
Television Jack
O
Telephone Jack
ACDiscA/C
Disconnect
I x 4 Florescent Light
®
2 x 4 Florescent Light
®
sv
Speaker Hook -Up
I❑
Intercom
® = JUNCTION BOX TO SUPPORT A FAN
Electric Notes:
A/C dac.
15o
#2/0 Aluminum feed AMP
I " Cori PAN
%sEL
Vent thru
Soffit --
AiC
124 CFM
IOXIOXb
MASTER'
BEDROOM
124 CFM
IOXIOXb
i
i
i
i
F 1,
-
12xI
B/A /A
12x12xI0
B/A
L J 141 CFM
IOxiox-i
PORCH
141 CFM
IOXIOxl
8x•4x4
9 CFM
I GREATI ROOM
tLO-C
SETI I
I
IOx6x6 o
-- 50 CFM - -
DRYER ASHER
I
r LAUNDRY
4 CFM
8x•4x4 I 141 CFM
IO
12" 1171
° I
°
i I
16 CFM DINING
8x4x4 ROOM
�� � I I
�J I
12x12x8
B/A��1
in
DW I
Ill CFM
12x6x1
SECOND
BEDROOM
12xl2xe
B/A
100 CFM
IOx6x6
I. Use copper wire only, no aluminum. �1
detectors.
2. Provide and wire all required smoke
3. Contractor to verify location of electrical
150 Amp
Panel
service and provider. AHu
4. ALL paddle fans shall be on a rheostat. PVC if
5. ALL bath and kitchen receptacles to be GFI protected. 2"
r
I GOLF C A R
6. ALL exterior outlets to be WP/GFI protected. " `^''^
GARAGE
1. Recessed cans to be installed per NFPA requirements.
1
8. AFCI receptacles are required in all rooms except
1
Kitchen, Bathrooms, and Garage. 2• rigid service FPL Bxs sL coprpe�°`;� dah
to as cant.
9. A/C Return Air Balance Must comply w/ FBC RMIL02
i
10. A/C Refr1gerant lines that are run thru slabs must be
sleeved in PVC ELECTRICAL. RISER
I
1
II. ALL A/C Equipment shall comply with energy calculation
I
12.
All work shall be performed bg a licensed electrical
- Contractor shall use AL-CU Landing
lugs. NTS
contractor, the completed system shall be full operative.
- Contractor shall torque luga I.A.W.
IS.
Contractor shall pay for all fees, permits, tes in and
manufacturers recommendations which
inspections including blower testing who required,
shall be verified prior to construction
14.
All work shall be coordinated with other trades to avoid
19. The electricals stem shall be
y
coin letel and effective)
p y y
15.
interference with the progress of construction.
All required insurance shall be provided for protection
grounded as required bg the latest edition of the N.E.C.
against the public liability and property damage for the
20. All material shall be new and
shall bear underwriters'
duration of the work,
labels where applicable.
16.
Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
21. All equipment and panel sizes
shall be verified before
the date of acceptance or certificate of occupancy, or one
ordering. The contractor shall
provide circuit routings to
year from closing sale of house.
suit the Job conditions.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
22. Furnish and install all fixtures
as called for on the plans
other phase of installation that may have been damaged.
or as selected by others.
11.
It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
23. All raceways and pipes placed in or through any concrete
all items for a complete electrical system and provide all
slab shall be spaced a minimum
of three diameters of the
the requirements necessary for the equipment to be placed in
largest conduit or pipe from any other service.
proper working order.
18.
All work shall be done in accordance with the N.E.C. and
24. All exposed wire below 9'-1"
shall be installed in metal EMT
shall comply with all local codes and ordinances, and shall
conduit.
meet all standard requirements of the local electric utility
25. Dryer Vents to be installed
per FBC RM1502
and telebhone combanu.
1�-_fir
�-J•�124
CFM
..
L. <ITCH1EN
-
• • r MICRO
-
LZJ
ssr.•.•x.•.tma•.rs•.•.en• .•atcsv..assa
low
INA
Lu
IQ�
8X4X�
a CFM
4" ol) Steel Ballard
See detail on this sheet
r -�
I 22" x
Attic Access
with light
L-----�
GARAGE
r-----------------1
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
MF.CH,4NfCAL L,4Y0U7
C= THERMOSTAT LOCATION SCALE: 1/4" = I' - O
3 TON
SEE MANUAL
"J" and Energy
Calculation
for Unit info
Install oulet
under d1@a.-
not shown for
clarity
I
MASTER
BEDROOM
WP GFCI
i
�S
5
rm ® C
S
I
° I
GFCI CLOSE I
- - - - J
DRY4R 11 .^�R�
LAUNDRY
I
I
I
I
I
I
I
GREATROOM
I
®I
/I
/ I
/ I
/ i I DINING
ROOM
I
I � C
v
E- zFacAeO I III
. #
=E) �-
�� C HEI
/ I p,V I
REP. I ®xONRVUIEAT� CiFCI
/ 3e• ENIN4R - O - J
t /
- GFCI GFCI
FCI
THIRD
/ \ 4" 4 Steel Ballard
See detail on this °heat
W _ _ _ _
4 1 > I F -22" x 54" i
/ I
12 S T thght u
Lam' L---�-�
/ I OPTIONAL PANEL
_ / -S LOCATION
FCI ' / 1 �\ GARAGE
/ GFCI \
150 Amp /\
Panel GFcI \ y� ,���P
° Conn" \
\ 'l' GFCI
-----
gn
Garage1) oor / Garage i
jOpener Door
I I / i Opener 1
GOLF CART;
GARAGE
� I
I
GFCI I I I I
I 1 GFc1 to )r/rage lights I 1
ELF-CTRIC,4L. FL,4 1 -----,
Post Light with O
SCALE: 1/+4" = I'-O" Photo cell 1
Center Post Light or
between driveways
SECOND i S
BEDROOM,/
Attic Ventino Calculations
Total Attic Space = 2101 sq. ft.FBC 2309.1
Venting Ratio 1/150 = 18.00 sq. ft. required
Provide A Continuous Vented Soffit
AiC
Wire For
Front Post
Light
Braden It Braden AIA, PA
Architects - Planners-25-I6
S.E. Coconut Avenue
Telel (112) 281-8258
BFax (�l2) 28�-8283
E-mail: bradenaiaOcomcast.net
Stuart FL 34994 UAAC000032
Wynn' Building Corp.
T I..� f >\l D S O R
MODEL:
REAR
PORCH
RIGHT
Date Drawn
Drawn by:
CU
C...
C hecked by:
D.R.B.
Revisions :
10-18-16 Product
Approval Revision
4-4-11 Plan review
Sheet
OF 5
Comm #
Spanish Lakes
St. Lucie County Florida
Y`
s
4w