HomeMy WebLinkAboutRevisions OFFICE USE ONLY: 7 1 V E
REC,
DATE FILED: APR 0 2017 PERMIT# 1702-0189
REVISION FEE: RECEIPT#
oER 4TING
St.Lucia County, FL
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORYPIERCE,,FL 34982-5652
(772)462-1553 FAX(772)462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. T LOCATION/SL � � s
"/ ;rLORIDA WAY "..r
ADDRESS: ` s °
2. DETAILED DESCRIPTION OF PROJECT J e "L
REVISIONS:
PRODUCT APPROVAL AND ENERGY CALC UPDATES `1' ' 'X
3�. CONTRACTOR INFORMATION:
_ STATE of FL REG./CERT.#: ST.LIICIE COUNTY CERT.#: 8898
►. BUSINESS NAME: orpora ion
QUALIFIEADDRESS:
NAI South U wy. Suite 402
CITY: Fort St. Lucie STATE: FE ZIP: 3495
PHONE(DAYTIME): - FAX: 772 878-7 56
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. I Suite 402
CITY: STATE: FL ZIP: 34952
PHONE: 772) 878-5513 FAX: (772) 878-7656
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN&BRADEN
ADDRESS:
CITY: STUART STATE: FL ZIP: 34996
PHONE(DAYTIME): (772) 287-8258 FAX:
Revised 07/22/2014
R 0 Em V I S I O'k
wrightsoft Project Summary pat
Entire House By:
QUICK CALCS, INC. File Cop;
317 ST.'LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466�796. Email:QUICKCALC.S@AQL.COM:
Project
• - • a-
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERC
Notes: '
Design Information
Weather Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db. 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh Structure 17520 Btuh
Ducts 5654 Btuh Ducts 8536 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
Humidification 0 .Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 24753 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality. Average
Fireplaces 0 Structure 3203 Btuh
Ducts 2318 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Cool' (none).
Area e( 1446 Tat Equipment latent load 5521 Btuh
Volume(ft3) 12511 12511
Air changesJhour 0.45 0.23. Equipment total load 30274 Btuh
Equiv.AVF(cfm) 94 48 Req.total capacity at 0.70 SHR 2.9 ton
Heating.Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC536A*030 Cond 25HBC536A"030
AHRI ref -7914585 Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 24360 Btuh
,Heating output 34600 Btuh_@ 47OF Latent cooling 10440. Btuh
Temperature rise 27. OF Total cooling 34800 Btuh
Actual air flow 1160 cfm Actual.airflow 1160 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh
'Static pressure 0.50 in H2O Static pressure 0:50 in Fi20
Space thermostat Load.sensible heat ratio 0.83
Capacity balance point 32 OF
Backup:
Input=7 kW, Output 23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wri htsoft` 2017-Apr-11 09:29:38
r 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACM ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
= -wrightsort° RighW@ Worksheet Job:
Entire_House Date:
By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:77246M799 Fax 772A66-6796 Email:QUICKCALCS@/\OLCOM
1 Room name Entire House BEDROOM
2 Exposed wall 156.2 ft 49.0 ft
3 Room height 8.7 ft d 8.0 ft heat/cool
4 Room dimensions 1.0 x 297.0 ft
5 Room area 1445.5 ft2 297.0 ft'
Ty Construction U-value Or HTM Area (ft-) Load Area (ft-) Load
number (Btuh/ft'°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-0ocs- 0143 n,` 4:00 255 503 465 1862 1184 .: 72 72 288 ,183
4A5 tom 0,70 _n; 2156 "19.31 :38 0. 815` 730:. 0 0.
13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0
WEI 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W;-. '13A4ocs 0143 'se 4.00 Z55 34 34 136 86 0 : 0• - A. 0
W 13A4acs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550
--G 1A-c1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0
T�i13A-46cs 0143 w. 4:00 2.55 310 237 949 603 104 72 288 183
;1A�1om 1270 w. 35:56 5521 32 2 1140 1770 ;• 32 2 1140 1770'.
4A5 tom O T/0 :w 21.56 19.31 41i 4.1 880..= 788 >.: 0:: 0 0 0
P 12C-0sw 0.091 2.55 1.28 192 192 489_ 246 0 0 0 0
090` 232 '1446 , 1446 .. 1295;:_ 3354 297 266 689
F 22A-tPI 0.989 - 27.69 - 0.00 1446 156 4325 0 297 49 1357 0
6 c)AED excursion 918 627
Envelope loss/gain 14961 13349 4204 4003
12 a). Infiltration . 2887 791 848 232
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 3 .690
Appliances/other 2000 0
Subtotal nines 6 to 13) 17848 17520 5053 4925
Less e)demal load 0 0 0 0
Less:transfer 0 0 0 0
Redistribution 0 0 0 0
14 SSubtotal 17848 17520 5053 4925
15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400
Total room load 23503 26056 6653 7325
Air required(cfm) 1160 1160 328 326
-Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- wcightsoft- 2017-Apr-1109:29:38
Right-Suite®Universal 2017 17.0.14 RSU0810t Page 1
...uick Calcs\Dccuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
'- -wriylhtsofts Right-J®Worksheet Job:
Entire House Date:.
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,10L.COM
1 Room name WIC KITCHEN
3 R ed wall he height 8.0 ft Oft heat/cool 8.0 ft Oft heat1cool
4 Room dimensions 6.0 x 9.0 ft 1.0 x. 1720 ft
5 Room area 54.0 ft2 172.0 ft2
Ty Construction U-value Or HTM Area 2 (ft2) Load
number (Btuh/ft2--°F). (Btu or or perimeter (ft) (Btuh) ors perimeter- (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A4ocs: 0143 n; 4.00 2;55 0 0 0 0 0 0
_ ,4A5 tom 0.770 n: 21:56 1931 0 0 0 .0. 0,
`_0
13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
11 -G 1Aclom 1.270 a 35.56 87.29 0 0 .0 0 0 0 0 0
L-D 11D0 0.390 a 10.92
11.31 0 0 0 0 0 0 0 0
W :.13A4ocs, 0143 se 4:00 255 0 -0. 0, 0 0 0; 0 -0
yJ 13A4ocs 0143 s 4.00 2.55 0 0 0 0 0 0 0 0
-G 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13 s" "0 143 w 4 00 255 0 0 0 0 0 0 :0 0
1A. 1om ; 1 270 w. 3556 55.21. 0 0 0. 0 0 0 0 0:
<0 ' 0 ,w 21:56. 19 31 : 0 .. 0 i.. 0. :: 0 0 r. 0 0 0
P 12C Osw 0 091 - 2.55 1.28 0 0 6 0 _ 64 64 163 82-
C '.1 30md 0 032; 0 90 2 32 54 54 -. 48 s 125 �172. `-_1721. 454 ,:399
F 22A tpl 0 989 - 27.69 0.00 54 0 0 0 172. 0 0 0
T.
6 c)AED excursion -9 -170
Envelope loss/gain 48 117 317 311
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 2000
Subtotal(lines 6 to 13) .48 117 317 2311
Less exfemal load p p .0 0
Less transfer 0 0 0 0
iRedistributipn 0 0 0 0
14 Subtotal 48 117 317 2311
15 Duct loads M 49% 15 57 .32% 49%1 100 1126
Total room load 64 174 418 3437
Air required(cfm) 3 8 21 153
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Aft - .wrightsoft 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
uick CalcslDocuments\THE GRAND CARLTON-1446.rup Caic=MJ8 Front Door faces: N
= -wrghtsoft° Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:.QUICKCALCS@/\OL.COM
1 Room name BATH BEDROOM 2
2 Exposed wall. 5.0 ft 34.2_ft
3 Room height 8.0 ft heat/cool. 8.0 ft heat/cool
4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft
5 Room area 45.0 ft2 203.5 ft2'
Ty Construction U-value. Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool. Gross N/P/S Heat Cool Gross N/P/S Heat. Cool
6 13A-0ocs 0143 n: 4 00 2;55 40 40 160 102 128 128 573 326
0 770 n 21:56 19:31 Al: 0 : q i0 :0
13A4ocs 0.143 a 4.00 255 0 0 0. 0 80 56 225 143
1A-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13A-0ocs• Oi143 t.se 400 2:55.. 0 . 0 0 . 0, _34 34 136 86
V!/ 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
t—G 1A-c1om 1270 s 3556 3477 0 0 0 0 0 0 0 0
8A-0ocs 0143 w 4 00 2 55 0 0 0 0 0 0 0 0:
1A. 6 1270 w-: 35 58 55 21 0 0 0 0 0=. 0 0 0.
4A5 tom 0 T/0 w: 21.58 193.1 0 0 0 0. '; 0:: 0 0 0,
P 12C-0sw . 0 091 2.55 1.28 0 0 0 0 0 0 0 0
C , : 16A 30md 0 032 -.: 090 2;32 „45.:` 45 40 104'. 204 204 472
IF 22Aapl-._ 0.9 27,69 0;00 45 5 138 0 204 34 946 0
6 c)AED excursion -16 -85
Envelope loss/gain 339 190 2978 3106
12 a) Infiltration . 87 24 593 162
b) Room ventilation` 0 0 - 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
tubtotal(lines 6 to 13) - 425 214 3571 3498
Less odemal load. 0 0 0 0
Less transfer 0. 0 0 . 0
Redistribution 0 0 0 0
14 Subtotal 425 214 3571 3498
15 Duct loads 32% 49o/u 135 104 32% 49% 11311 1704
Total room load 560 318 4702 5203
Air required.(cfm) .28 14 232 232'
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-41- wrightsoftl 2017-Apr-11 09:29:38
.4> A Right-Suite®Universal2017 17.0.14 RSU08101 Page
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
+wrightsoft' Rightm-M Worksheet °b
Entire House °ate: .
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALC8@lA0L.00M
1 Room name LAUNDRY GREAT/DINING
2 EVosed wall 6.0 ft 47.0 ft
3 Room height 8.0 ft heat/cool 9.8 ft heat/cool
4 . Room dimensions 7.0 x 6.0 . ft 1.0 x 626.0 ft
5 Room area 42.0 ft2 526.0 ft2
Ty Construction U-value. Or HTM Area (ft2) Load Area (ft5 Load
number (Btuh/ft2-°F) (Btu 2) or )
2) perimeter (ft) (Btuh): or perimeter (ft) (Btuh
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat- Cool
6 yJ 13A flocs 0143 n= 4 00 255 0 0 0
r_ G, 4A5 tom 0 770. n 21:56 19:31, 0 0 0 0 38 U 815 . 730':
13A4ocs 0.143 a 4.00. 2.55 0 0 0 0 0 .0 0 0
1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11130 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13A1tocs 0.143 ,se 4.00'. 2:55 0 0 0 . 0 0 0 0 0
W 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0
T--G 1Aclom 1270 s 35.56. 34.77 0 0 0 0 0 0 0 0
13A-4ocs 0143 w 4 OD Z55 0 0 0 0 206 165 661 420,
9Ac1om 1270 w,: 35"56 55.21 0 0 0 0 0 0 0 0
.4A5 tom 0 770, w 21.56 19r31 0 - 0 41' 880 788'
P 12C-0sw 0.091 2.55 1.28 56 56 143 72 0 0 .0 '0
C >16A30mtl' "0 032 0;90 2 32 42 42 38 97 526 '. 526 471 'I MO
F 22A-tpl 0.989 27.69, 0.00 42 6 .166 0 526_ 47 1302
41
6 c)AED ocursion :22 668
Envelope loss/gain 539 270 4997 4379
12 a): Infiltration 104 28 997 27.3
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 2 .460
Appliances/other 0 0
Subtotal(Iines 6 to 13) 643 298 5994 . 5112
Less wdemal.load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 .Subtotal 643 298 5994 5112
15 Duct loads 320% 496A 204 145 32% 49% 1899 2490
Total room load 846 443 7892 7602
Air required(cfm) 42 20 3901 338
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
At wrightsoftft 2017-Apr-1109:29:38
A Right-SuiteO Universal 2017'17.0.14 RSU08101 Page 4
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
-wr gntsoft Right-M Work-sheet Job:
Entire House Date:
QUICK CALCS, INC: By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name FOYER M.BATH
2 .Exposed wall 7.0 ft 8.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft. heat/cool
4 Room dimensions 1.0 x 50.0 ft 7.0 x 8:0 ft
5 Room area 50.0 ft2 56.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2L-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or )
perimeter. (ft) (Btuh
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat, Cool
6 13A�ocs 0143 n 4:00 255 8 8 32 20 ;; 0'' 0 0 0
.4A52om `.. 0 770 n 21.56 1931 0
13A4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0
T�:�'D'
G 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W 13A4ocs' 0143 se 4.00 2.55 0 0 0 0 0` 0 .0 0
W 13A4ocs 0.143 s 4.00 255 0 0 0 0 64 57 228 145
t-G IA-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241
13A46cs 0143 w. 4.00, 255 0 0 0 0 0 0 0 0,
1Ac1om 1i270 w 35.56 5521 0 0 0 0 0 0. 0 0.
4A52om Q'770 .w.; 21:56.. . 19.31. 0 0_`.
P 12C-0sw 0.091 ,- 2.55 1:28 .72 72. M 92 0 0 0 0
C , . ;., Mmi:17 _0 032 0:90: _. .. 50 45 116;, 56 =.56 50
F 22A tP1 0,989 27.69 0.00 50 7 194. 0 56 8 222 0
6 c)AED e»ursion -39 _38
Envelope loss/gain 792 496 747 478
12 a) Infiltration 121 33 138 38
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 .0
Subtotal pines 6 to 13) 913 529 - 885 . 516
Less odemal.load 0 0 p p
Less transfer 0. 0 0 0
Etedistribution 0 0 0 0
14 Subtotal 913 529 885 616
15 Duct loads 32% 49% 289 . 258 32%1. 49% 280 251
Total room Iced 71202 787 1165 768
Air required(cfm) 59 35 58 34
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- 2017-Apr-11 09:29:38
A Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJB Front Door faces: N
wri h Duct System Summary Job:
g tsoft y Date:
Entire House By:
QUICK CALLS,INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799.Fax.772-466-6796 Email:QUICKCALCS AOL.COM
Project Information
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Heating. Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available.static pressure .0.50 :in H2O 0.50 in H2O
Supply/.return available pressure 0.2$0/0.250 in H2O 0:250/0.250 in H2O
Lowest friction rate 0.285 in/100ft 0.285 in/100ft
Actual air flow 1160 cfm 1160 cfm
Total effective length.(TEL) 176 ft
SupplyDetail Table
Design Htg Clg Design . Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk
BATH h 560 28 14 0.364 4.0 OxO VIFx ' 22.4 115.0 st1
BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 SO
BEDROOM-A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2
BEDROOM-s h 3327 164 163 0.285 6.0 ox0 VIFx 40.6 135.0 st2
FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0
GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8. 135.0 st2
GREATIDINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2
KITCHEN c 3437 21 153 0.379 .6.0 Ox 0 VIFx 17.0 115.0 st1
LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1
M.BATH-A h 768 58 34 0 0 Ox0 VIFx 0 0
wic C 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 0
Supply Trunk Detail • -
Trunk Htg, Clg Design Veloc Diam H x W Duct
Name Type (cfm). (Cfm) FR (fpm) (in) (in) Material Trunk
st2 Peak AVF 721 672 0,285 918 12.0 0 x 0 VinlFlx st1
st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx
�.� � wri htsoft@
9 Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38
Page 1
XIC ...Uick Calcs\Documents\THE GRAND CARLTONA446.rup Calc=MJ8 Front Door faces: N
Return Branch Detail Table
Grille Htg .Clg . TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR . . (fpm) . (in).:, (in) Opening(in) Matl: Trunk
rb1 OxO . 1160 1160 . 0 0 0 0 Ox 0 VIFx
wrightsoft' :Right-Suite®Universal 201 2017-Apr-11 09:29:387 17.0.14 RSU08101 Page 2
�+�^ ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
FORM R405-2014
FLORIDA ENERGY, EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Proje Strreett Name: WYNN DEVELOPMENT Permit Office: STY LUCIE COUNTY ENT File
Copy
City,State,Zip: FT.PIS E, FL, Permit Number: fit'
kIQJsign
ner. L�\ L,J Q Jurisdiction:
Location: FL,West Palm Beach County:: ST.LUCIE COUNTY(Florida Climate Zone 2New construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area
Z. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
b. Frame-Wood,Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area 2
a. Under Attic(Vented) R=30.0 1446.00 ft
6. Conditioned floor area above grade(ft2) 1446 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(139.2 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 320
a. U-Factor: Dbl,U=0.54 99.23 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 - a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1446.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 53.72 PASS
Total Baseline Loads: 54.66
I hereby certify that the plans and specifications covered by Review of the plans and Oke11JE STgT�
this calculation are in compliance with the Florida Energy specifications covered by this :
Code. calculation indicates compliance
with the Florida Energy Code.
PREPAR D Y: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
rll'
I hereby certify that this building,as designed, is in compliance Florida Statutes. ✓� 5�
-with the Florida Energy Code. G'Ojj WE
-OWNER/ N BUILDING OFFICIAL:
D-A�TE: DATE:
L _
- Compliance requires certification by the air handler unit manufac th o r f
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Chec or 02. n `' lope leakage
test report in accordance with R402.4.1.2.
4.
4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
risdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
F mily Type: Single-family FL,
N w/Existing: New(From Plans)
C)Dmment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,West Palm Beach FL WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1446 12514.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes
2 WIC 54 432 No 0 1 No Yes Yes
3 MASTER BATH 63 504 No 0 1 Yes Yes Yes
4 M.BATH 56 448 No 0 1 Yes Yes Yes
5 KITCHEN 172 1376 Yes 0 1 No Yes Yes
6 BATH 45 360 No 0 1 Yes Yes Yes
7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes Yes
9 GREAT/DINING 526 5154.8 No 0 1 Yes Yes Yes
10 FOYER 50 400 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 ---- 0 1 0
5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0
6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ___- 0 1 0
it
4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0
ROOF
y Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
10 Under Attic(Vented) FOYER ' 30 Blown 50 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>SE Exterior Concrete Block-Ext InsiHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsiHEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0
_ 3 W=>NE Exterior Concrete Block-Ext InsiflEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext InsMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
5 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
�- 6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
7 N=>SE Exterior Concrete Block-Ext Ind3ffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext IndIffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0
10 S=>NW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0
11 S=>NW Exterior Concrete Block-Ext InstILAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
l
FORM R405-2014
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
()rot In Wall Type Space
lle Et n Et_13 W=>NE Exterior Concrete Block-Ext InsGREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ftz 0 0 0.5 0
15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ftz 0 0 0.5 0
16 N=>SE Exterior Frame-Wood GREAT/DINI 11 23 5 8 187.3 ftZ 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 20 ftz
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 .32.4 ftz 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ftZ 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ftZ 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ftz 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ftZ 10 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315ft2 315ft2 24ft 8ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000385 1460.1 80.16 150.74 .2656 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None Node ftz
DUCTS
—Supply— ---Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ft2 Attic 80 ftz Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr [ ]May rl
Jun rl
Jul ri
Augrl
Se Oct [ ]Nov Dec
Heatin HJan HFeb Mar E Apr [ ]May Jun Jul AuSep Oct [ Nov X Dec
Ventin Jan Feb X Mar [X]A r [ ]Ma Jun Jul Aug Se [Xl Oct [X]Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
4/3/2017 6:36 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: Jurisdiction:
~' Design Location: FL,West Palm Beach
1'
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 6:36 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
. The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2 Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1250.00 ft2
b.Frame-Wood, Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area 2
a.Under Attic(Vented) R=30.0 1446.00 ft
6. Conditioned floor area(ft2) 1446 b.N/A R= ft2
7. Windows" Description Area c.N/A R=
2
a. U-Factor: Dbl,U=0.54 99.23 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Attic 6 320
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2EF:0.97
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building 4,094E Sr�q?,
Construction through the above energy saving features which will be installed (or exceeded) .y0 _ �o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,;''��'
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home-. q SA City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff..
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/3/2017 6:36 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1