Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
t 1 qof REVUVED FOR MIAMI•DADE CODE COMPL LAN _ M �+ I DADE COUNTY T. C I E C `CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURC9§Wkqk) 1805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION B O `/�q�7�Miami,Florida 33175-2474 (.Aft `! 021 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) Permitting p.p arCrpont www.miamidade.1!ov/economv St. 6�isic�County Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically tenninate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0711.01 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino NOA No.: 18-0509.15 CMIAMI-�DADECOUTIT! Expiration Date: 04/26/22 IF'fje COPY Approval Date: 06/28/18 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile,as manufactured Boral Roofing LLC in Lake Wales,FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 Length= 17" TAS 112 High profile,interlocking,one-piece, 'S'shaped, Width= 13" Type— 1 a high-pressure extruded concrete roof tile %" thick equipped with three nail holes. For direct deck or battened nail-on,mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim,boosted Barcelona,concrete Width: varies roof pieces for use at hips,rakes,ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) ICP Adhesives Polyset®AH-160 Two component polyurethane ICP Adhesives and Sealants,Inc. foam adhesive. TILE BOND'Roof Tile Adhesive Single component polyurethane The Dow Chemical Company foam roof tile adhesive. DAP Foam Touch N Seal Two component polyurethane DAP Foam Inc. StormBond®2 Roof Tile Adhesive foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales,FL NOA No.: 18-0509.15 MIAMIDDAD,COUNTY Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 2 of 8 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102&TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108(Nail-On) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail-On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries,Inc. IC-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3"Headlap,Nails,Direct Deck,New Construction) The Center for Applied Engineering,Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4"Headlap,Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering,Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) NOA No.: 18-0509.15 MIAMI•DADECOUNTY Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 3 of 8 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may require,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix`A'. Such testing shall be submitted to the Department of Regulatory and Economic Development—Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-I (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -A (ft') Tile.Profile A (ft) A (ft3) Batten Application Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity- M9 (ft-lbf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 Deck Deck Deck Deck Deck Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42 NOA No.: 18-0509.15 MIAMI•DADECOUNTY Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 4 of 8 Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank 5.1 6.8 2.8 Nail 2-10d Smooth or Screw Shank 6.9 9.2 7.3 Nails 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank 23.1 23.1 19.0 Nail Field Clip) 1-10d Smooth or Screw Shank 29.3 29.3 24.0 Nail Eave Clip) 2-10d Smooth or Screw Shank 27.6 27.6 38.6 Nails Field Clip) 2-10d Smooth or Screw Shank 38.1 38.1 41.8 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19132" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4"the headlap and fasteners are located a min. of 2%'from head of tile. NOA No.: 18-0509.15 MIAMI•DADECOUNTY Expiration Date: 04/26/22 1 Approval Date: 06/28/18 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Paddy Adhesive' Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Tile Bond TM One Component Roof Tile Adhesive 29.32 ICP Adhesives Polyset®AH-160 two-component foam 29.33 DAP Foam Touch N Seal StormBond®2 Roof Tile Adhesive 664 1 See manufactures component approval for installation requirements. 2 TILE BONDtm Roof Tile Adhesive;Average weight per paddy 10.7 grams. 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160;Average weight per paddy 8 grams. 4 DAP Foam Touch N Seal StormBond®Roof Tile Adhesive Two-Component;Average weight per paddy 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 ICP Adhesives Polyset®AH-160 two-component foam 66.5 5 ICP Adhesives Polyset@ AH-160 two-component foam 38.7 6 DAP Foam Touch N Seal StormBond®2 63 7 DAP Foam Touch N Seal StormBond®2 82 8 5 Large paddy placement of 63 grams 6 Medium paddy placement of 24 grams 7 Medium paddy placement of 30 grams 8 Large paddy placement of 60 grams Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Barcelona 900 Mortar Set' 24.5 9 Seespecific mortar manufacturers Notice of Acceptance NOA No.: 18-0509.15 MIAMI•DADE COUNTY Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 6 of 8 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0509.15 MIAMI-DADeeourr Y Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 7 of 8 PROFILE DRAWING `NAIL HOLES a bVERLOCK Z. i r UN©ERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 18-0509.15 MIAMI•DADE COUNTY Expiration Date: 04/26/22 � � Approval Date: 06/28/18 Page 8 of 8