Loading...
HomeMy WebLinkAboutBuilding Plans1 L, U) z 0 Z Lc) /= � y�� � z M J U U) CI) z o oLLI co �� Wo7 z Q N �0 Wes^' ¢LLiv W=' U v`O Lwa om; 02 WE W EXISTING v%) z Upy — -- -- — — — - MOBILE-- -- HOME 9'- 1 " B — — — — ADJACENT ROOF 9'- 1 " — — -- — 9'- , " . VZAe�c P M9'� Ottp COQ %,0++�c • ®+ .. -��acto- Q I—LI °6UwU)LL oL� LLI U � o m Z `D zp � L<Izn - w cUh � zSOT Q w_ (n . Na- LL (0 Q C-4 B-9 N FLASH TO ADJACENT ROOF C-3 3068 SCREEN EXISTING DOOR CARPORT �� C-3 / C-4 B-9 C-4 4TH WALL SEE DETAIL PROPOSED SCREEN ROOM w/ PAN ROOF ON EX. CONC. SLAB w/ THICKENED EDGE B-9 C\ N C-4 T ' 0 O o O �� `� �� _ PROPOSED C-3 BONDED PANEL SHED w/ PAN ROOF � I C-4 COLUMN W/ I RECEIVING CHANNEL. ATTACH RECEIVING C-� 1 o CHANNEL TO COLUMN W/ 10 SMS @ 18" i IO.C. ATTACH PANEL TO o RECEIVING CHANNELW C-� 1 m # 10 SMS @ 6" O.C., INSIDE & OUTSIDE 2 Lu ❑ ` Q = \ ¢uJ ` Ow z J z w o ai # a� 'o o u- j W o m � N �. E - a SCALE: AS NOTED N m SEE CORNER COLUMN DETAIL Q I ^� c) h / B-2 J B=2 v B-2 v B-2 U ON EX. CONC. SLAB w/ THICKENED EDGE C-21 r N B-2 C-27 U I (TYPICAL @ C-4 & C-3 COLUMN). TYP. I I C-21, AS REQUIRED I PROVIDE 2-?t10 -4 SMS TOP & BOTTOM DATE: 10/30/2020 REVISED: DRAWN BY: KJS CHECKED BY: JB i EX. C - 4 SITE PLAN / FRAMING PLAN ------- 4'-10 --r-- ---- —� B� 4'-s —�'_o; — — — — — — — — 4'-s"--—4'-10"- cn — — U - — — — — — —�A NP �OH� N = OF "H" BEAM TO r J O INSIDE &OUTBID_ OF RECEIVING 12" CHANNEL. TYP, JOB No. 20-10-01 A— 1 SCALE: 1 /4 = 1 —0 30'-0•' SHEET No. 1 OF 4 SCOPE OF WORK: 1. INSTALL NEW SCREEN ROOM w/ ALUMINUM PAN ROOF ON EXISTING CONC. SLAB w/ THICKENED EDGE. 2. INSTALL NEW BONDED PANEL SHED UNDER, ALUMINUM PAN ROOF. GENERAL NOTES: 1. ALL WORK TO BE IN COMPLIANCE WITH THE 2017 FLORIDA BUILDING CODE. 2. ALL EXTRUDED ALUMINUM COMPONENTS SHALL BE 6063-T6 ALLOY. 3. SCREWS AND BOLTS FOR ALUMINUM STRUCTURES TO BE PAINTED STEEL, ALUMINUM ALLOY 024-T4 OR STAINLESS STEEL. 4. WIND LOADS CALCULATED PER ASCE 7-10, BASED ON THE FOLLOWING: a. WIND SPEED = 150 MPH, 3 SECOND GUST b. BUILDING CATEGORY I c. EXPOSURE = B d. INTERNAL PRESSURE COEFFICIENT = ±0.55 FOR PARTIALLY ENCLOSED STRUCTURES. 7. SCREEN ROOM DESIGNED AS AN ENCLOSED STRUCTURE. 8. INSTALL 3" PAN PER PRODUCT APPROVAL. 9. SUBMIT PRODUCT APPROVALS FOR PAN ROOF, BONDED PANEL WALL MATERIALS AND DOORS. 10. ALL DIMENSIONS TO BE FIELD VERIFIED. 11. THIS PLAN NOT VALID UNLESS SEALED BY THE ENGINEER'S EMBOSSED SEAL. 2 - 3/8" THRU BOLTS 2-2/3„ 1-1/3" 1-11'3" �3/43/4" l!2" 21'xY COLUMN OR "H" COLUNIN #10 S.M.S. @ 12" O.C. FROM FLASHING INTO WALL HEADER AND TOP OF ROOF PAN w/ NEOPRENE WASHER � 2":Q"s.l2i"ANGLE ONE SIDE OF COLUNIN m/ (4) 910 scREws TO COLUMN RECEIVING CHANNEL p w.% 1/4"xi" CONCRETE SCREW EACH SIDE OF _ ni 0.040 COLUMN &, @ 24" O.C.1G1X SPACING 3"xl'" — PAN ROOF EXISTING FLASHING 24 GA ALUM. FLASHING MOBILE HOME NOTCH COLUMN FOAM FILLER AS REQUIRED FOR BEAM BOXED END OF PAN C4 (Y'0" COL.) (4) #10 SMS EACHY 1/2" CLEARANCE PAN INTO WALL 2 - 3/ 8" THRU BOLTS HEADER 15 & BEAM EACH COLUMN O Ix2 OPEN �2410SCHVS2ACH BOTTOM (OB) 6 - 1/4"x3" N.T.S. SIDE OFCOLUIVIN TAPCONS - - - -_- - FOUNDATION ANCHORAGE DETAIL N.T.S. Fq i N TAPCONS + j + + 1/2" - 2 - 3/8" �1/2 t THRU BOLTS 24 COL. BASE PLATE DETAIL Y.T.S. 4'-0 NTERLOCKNG TONGUE AND - GROOVE FOAM CORE FOAM CORE � 1 .030 ALUNI SHEET -- BONDED TO FOATvT CORE Nb DENSITY FOAM CORE n ALUM BONDED PANEL \,LJ N.T.S. 11 1-/-2"� I i in "H" BEAM 21 COLUMN N.T.S. 3 "x 12" PAN ROOF TYP. COLUMN / BEAM SECTION TH WALL CONSTRUCTION DETAIL 2 WALL PANEL CONT. 3"x.045 ALUM. RECEIVING CHANNEL EXTRUS. OR EQUAL — ,y8x9/16" SMS @ 6" O.C. EACH SIDE PREHUNG DOOR UNIT (FLANGE MOUNT) INSTALL PER MANUFACTURERS SPECIFICATIONS JAMB BEYOND DOOR HEAD @ PANEL WALL 2" 3" M 0.125 ° 0.125 f0.045 LIF ® 30 COL. O 9 2x6 BEAM BEAM LLOW N.T.S. N.T.S. O N.T.S. - 3" v-� N 16 "T" GUTTER N.T.S. n I 3/4„ � 15 lg FASCIA N.T.S. 2" r,EDO.045 HOLLOW COLUMN 0), T �S 00 N N o � — O WALL HEADER N.T.S. 2 3, 2 12" ' [-0.875 j -I I •� N h ry I- O._�0 \j 0.1875 �TO�750 25 + � 3 I WALL I WALL BEYOND 10 SMS r -` 0.032 1.25 �0.250 I BEYOND I 24" O.C. I } I 20 ROOF PAN N.T.S. DETAIL ) 0.045 IN 3" RECEIVING 27 CHANNEL N.T.S. CORNER COLUMN N.T.S. U oD 'J 7 — N >- < <0M W ;* m°T L` W w - U)z z L0 CO n�� N 0 Ln 0� � W I\ Q U) / it N O m w� �J N N W VJ � = �On N z = Lu o O U c O n WZ� z 0- o2 o0 !0 z o Q J ch � J 0 LL _ HLn Lu O _ oU< LU LLJ °� oz� LL az LU U) QW � � � O O Q la_� 1- U 1--LLJ Q (,/) z (V IZ < 1L CO_p_ LLJ o0 U p W N 7t pew ` a� Q W >� o =C IL �= to W 0 U) m zw`0 U) o ut p � m m = 2 0`. SCALE: AS NOTED DATE: 10/30/2020 REVISED: DRAWN BY: KJS CHECKED BY: JB JOB No. 20-10-01 A- 2_ SHEET No. 2 OF 4 EX. CONCRETE SLAB J w/ THICKENED EDGE FRONT ELEVATION (SCREEN ROOM) SCALE: 1/4" = 1'-O" EXISTING ROOF ALUM. PAN ROOF-, STRUCTURE EX. CONCRETE SLAB J w/ THICKENED EDGE FRONT ELEVATION (BONDED PANEL SHED) SCALE: 1/4" = 1'—O" EXISTING ALUM. ROOF FLOOD VENT IF REQUIRED IN FLOOD ZONE PAN ROOF PANELS TO UNDERSIDE OF EAVE (4) #10 SMS @ EA PAN W/ NEOPRENE WASHER W GUTTER (2) #10 SMS @ EA PANEL FOR T-GUTTER RECEIVING CHANNEL W/ #10 SMS, MIN. 5 PER 4' PANEL, AROUND OPENING, INSIDE AND OUTSIDE 3" BONDED PANEL RECEIVING CHANNEL W/ #10 SMS, MIN. 5 PER 4' PANEL, AROUND OPENING, INSIDE AND OUTSIDE. ATTACH CHANNEL TO CONC. IN/ 1/4"x1-3/4" TAPCONS @ 24" O.C. EXIST'G 4" CONC. SLAB EX GRADE THICKENED EDGE TYPICAL .SECTION A ell 1r-r1 IA/ 11 MA NI r)�Y-'\r EXISTING ROOF STRUCTURE BEYOND 3" ALUMINUM PAN ROOF U Q° N r¢�o ¢�' Ww° a w U) z z ' o Esm q-Q Lu z O rn Q w� ��o U W=CO U) U) U n N z LW� 0m o U wL� cu C)o� —� r0 d z O Q cy) J c) " oW Lcj _ O o U� Jac) WU) 06 pzo LL 0-Qw u)C� O O QED- D �� U1-7w CC Q U% � z �l Na- �- , LL (0 LLI 0 U c/) U) r rn W J. D N Z V Q J a) -O Q cr) U > 07 C LL 0 _ L O O w ~ ; CD- N N (0 z z rn o r� 3 N O c O 0- SCALE: AS NOTED DATE: 10/30/2020 REVISED: DRAWN BY: KJS CHECKED BY: JB JOB No. 20-10-01 A-3 SHEET No. 3 OF 4