HomeMy WebLinkAboutAPPROVED Frank-Metal Alliance-24ga-1.5 inch-FL Approval.pdf 1/1 21202 1 Florida Building Code Online
4:
Business & Professional Regulation
BCIS Home Leg In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Lime: Search
Ada
Product Approval" pr
lim-
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL29523-Rl
f Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Metal Alliance Inc.
Address/Phone/Email 2120 SW Poma Dr.
Palm City, FL 34990
(844) 638-2548
orders@metalalliance.com
Authorized Signature Tara Faulkner
orders@metalalliance.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2030
Validated By lames R Wally, PE
Validation Checklist- Hardcopy Received
Certificate of Independence EL29523 RI COl 32AI 100SL p ywo0d nonHVH;'_pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https:/ANww.floridabuilding-org/pr/pr app_dtl.aspx?param=wGEVXQwtDquDjJZGKCHOBeuJtRZVS4wAPLbCuLWfBsMgrM4sxtfrSA%3d%3d 113
111212021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/11/2020
Date Validated 08/13/2020
Date Pending FBC Approval 08/19/2020
Date Approved 10/13/2020
Summary of Products
FL# Model,Number or Name Description
29523.1 01. 100SL 1" Nailstrip 032 Aluminum 100SL 1"Nallstrip panel from nominal 0.032"aluminum or
thicker on 15/32"(min) plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL29523 R1 It 32AI 100SL RI wood nonHVHZ.pd€
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6" oc FL29523 R1 AE 32AI I005L plywood nonHVHZ.pdf
Created by Independent Third Party:Yes
29523.2 02: 1005E 1"Nailstrip 24ga Created
1"Nailstrip panel from 24ga(min)on 15/32"(min)
plywood or 3/4" (min)wood plank
Limits of Use Installation instructions
Approved for use in HVHZ: No FL29523 R1 Ii 24ga 1005L plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-206 Evaluation Reports
Other: 206 psf @ 6"oc FL29523 R1 AE 249a 100SL Rlywood nonHVHZ.pdf
Created by Independent Third Party: Yes
29523.3 03: 1005L 1"Nailstrip 26ga HVHZ 1005L 1" Nailstrip panel from 26ga(min)on 15/32" (min)
plywood or 3/4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 RI 11 269a 10O51- plywaod.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-176 Evaluation Reports
Other: 176 psf @ 6"oc WITH sealant, 116 psf @ 6" oc without i FL29523 RI At 2694 100SL plywood•p&f
sealant Created by Independent Third Party: Yes
29523.4 04: 100SL 1" Nailstrip 032 Aluminum 1005L 1" Nailstrip panel from nominal 0.032"aluminum or
HVHZ thicker on 15/32"(min) plywood or 3/4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL29523 RI II 32AI 100SL plywoo .pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-175 Evaluation Reports
Other: 175 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 1005L plyw0od.pdf
Created by Independent Third Party: Yes
29523.5 05: 150SL 1.5" Nailstrip 24ga 150SL 1.5"Nailstrip panel from 24ga(min)on 15/32"(min)
plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 R1 II 24ga 150SL plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-153.5 Evaluation Reports
Other: 153.5 psf @ 6"oc WITH sealant FL29523 R1 AE 24ga 150SL Rjywood nonHVHZ.pdf
Created by independent Third Party:Yes
29523.E 06: 150SL 1.5" Nailstrip 032 150SL 1.5" Nailstrip panel from nominal 0,032"aluminum or
Aluminum thicker on 15/32" (min) plywood or 3/4"(min)wood plank
Limits of Use Installation Instruction$
Approved for use in HVHZ: No FL29523 Rl II 32M 1505L plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By. David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6" oc WITH sealant FL29523 R1 AE 32AI_154SL lyw od nnnHVHZ.pdf
Created by Independent Third Parry:Yes
29523.7 07: 150SL 1.5" Nailstrip 032 150SL 1.5" Nailstrip panel from nominal 0.032"aluminum or
Aluminum HVHZ thicker on 15/32" (min) plywood or 3/4" (min)wood plank
19"coverage
Limits of Use Installation Instructions
https:llwww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sx*SA°/a3d%3d 2/3
1/12/2021 Florida Building Code Online
Approved for use in HVHZ:Yes FL29523 R1 11 32AI 150SL ptywood.Ddf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168,1 Evaluation Reports
Other: 168.1 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 1505L Rjyyya2d.pL1j
Created by Independent Third Party:Yes
29523.8 08: 150SL 1.5" Nailstrip 24ga HVHZ 150SL 1.5" Nailstrip panel from 24ga(min) on 15/32" (min)
plywood or 3/4" (min) wood plank 1 19"coverage
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 R1 II 24ga 150SL plywo .pd1
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-112.5 Evaluation Reports
other: 112.5 @ 6" oc WITH sealant Icia 1505L plywood,pgf
Created by Independent Third Party: Yes
Back
SQnjact Us::ZfjO1 Blair Stone Road.Tallahassee FL 32399 Phone:_850-427-1824
The State of Florida is an AA/EEO employer. ynght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-maH address released in response to a public-records request,do not send electronic
mall to this entity.instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.27S(i),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for offic}ai communication with the Ilcensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® '-r.d 0
Credit Card
Safe
https://www.floddabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquDjJZOKCHOBeuJtRZVS4wAPLbCuLWf8sMgrM4sxtfrSA°/n3d%3d 3/3
AIL
METALALLIANCE
A Value Added Supplier of Metals
1 . 5 " NailStrip 24ga Steel Panels
24ga ( min ) 1.5" Nail Strip over 15/32" (min ) plywood
Metal Alliance, Inc
2120 SW Poma Dr I Palm City FL 34990
Produced by Metal Alliance's Network of Approved Regional Manufacturers
Product Description
Nailstrip, snaplock style panel with a 15" maximum panel width and a
nominal rib height of 1.5"
Product Material
24ga (min) steel
24ga is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion
resistant per FBC 1507.4.3 where required.
Fastener
#10 1-inch pancake style fastener
Compliant with FBC 1506.6 where required-
Substrate/ Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 w Univ Ave #206 1 Gainesville FL \,�`\ �y�D E.
FL PE 81377 1 FL CA 33344 QP' OCEN,3
ww_w_T.i_mberLakeC_ove.com
No. 81377
�-p0 STATE OF ((��
Obvid E Eng
150SL 2020.0 1 o
19:18:07-04'00'
This item has been digitally signed and sealed
1.5" NAI LSTR I P 24GA by D E Eng,PE,on the date indicated Printed
copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code_
Maximum Allowable Loads & Installation Requirements:
Method A. #10 x 1" fastener at-67-o.c_,_a_lon_gnail__strip_WI.TH sea la nt;_ 153__5_PSF.
A factor of safety of 2 has been applied_
Fasteners are installed through the metal flange, NOT through the pre-punched slots.
Technical Documentation :
This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report
J6368.12-450-44 RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2
(non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any
company manufacturing or distributing products under this evaluation. The same entities do
not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be
completed by others. Fire classification and shear diaphragm design are outside the scope of
this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as
required by Rule 61G20-3_ Neither Timberlake Cove nor the manufacturer shall be responsible
for any conclusions, interpretations, or designs made by others based on this evaluation
report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes nO
express or implied warranty regarding performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress_ These load tables are based on ASCE 7-16. Use
of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have ❑
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
AA&
METAULLIANCE
A Value Added Supplier of Metals
ENGINEERING LOAD TABLES
Instructions: i a
Select the appropriate load table that applies to e 2 2 3
the structure in question. a
2 1 1 Determine the design wind speed for the project 2
location. 2',
2 2 3 a
Use the attachment method indicated for that 2 t 2 2 3 a
windspeed within each roof zone. 1
2
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-2one 2 f 2
concept. For the load tables below, the worst case f t
was taken for each zone and reported using the a 3 2 2 3 a
standard zones 1-2-3: j Z
Zone 1 includes zones 1 and 1' tea+ HIP ROOF GABLE ROOF —a—
Zone 2 includes zones 2e, 2r, and 2n
L• 1`�Ov LEAST.<�ZORT�M ENSKW ON LM WNIGI�EYEN�5 SI�YLLER BUT N]>
Zone 3 includes zones 3e and 3r E55 TRAN LANER41.ca ELMY keweONr4 pIN[NS 04M uim WI
OR AS 0E TEWNED BT PE5*k OR OTHER AW+KAftE L11a1
Combining these zones creates a clear, simple ROOF ZONES FOR GENERIC BUILDING
scheme, at the expense of some design efficiency.
Contact Metal Alliance Inc for further information,
or consult a licensed design professional.
METHOD A
FE.1"LL EEG SNAPS
- ONTO MALE LEG
SEALANT APPLIED TO
BOTH SIDES
-10 FASTENER
AT 6-OG
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria.
Are located in Exposure B area Are located in B, G,or D exposure area
Have either a flat roof,or gable/hip roof with max slope of 45° Have either a flat roof, or gable/hip roof with max slope of 45'
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" plywood FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3. A A A A A A A
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located In B, C,or D exposure area
Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with
max slope of 45°,or gable roof with slope between 20'and 45' max slope of 45°, or gable roof with slope between 20`and 45°
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL29523.05: 24 a 150SL 1.5" nail strip on 15132" plVwood FL29523.05: 24 a 150SL 1.5" nail strip on 15/32" plvwood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A
Ask
METAULLIANCE
A Value Added Supplier of Metals