Loading...
HomeMy WebLinkAboutAPPROVED FL23359.2 SERIES 4110 HRProfessional Regulation BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I dbar Product Approval I�"' USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL23359-R6 Application Type Revision Code Version 2020 Application Status Approved Comments Archived C Product Manufacturer CGI Windows and Doors Address/Phone/Email 10100 NW 25 Street Miami, FL 33172 (305)593-6590 Lmiller@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Lynn Miller, P.E. Address/Phone/Email 1070 Technology Dr N Venice, FL 34275 (941)486-0100 Ext21142 Imiller@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the A. Lynn Miller, P.E. Evaluation Report Florida License PE-58705 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 02/19/2023 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL23359 R6 COI Cert of Independence.pdf Standard TAS-201 TAS-202 TAS-203 Year 1994 1994 1994 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/04/2020 Date Validated 09/08/2020 Date Pending FBC Approval 09/21/2020 Date Approved 12/16/2020 Summary of Products FL # Model, Number or Name Description 23359.1 HR-4010A Non -Impact Horizontal Roller Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23359 R6 II HR4010 CGI - REV Bl.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. 58705 Impact Resistant: No Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23359 R6 AE HR4010 Eng Eval CGI Bl.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. 23359.2 HR-4110A Impact Resistant Horizontal Roller Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23359 R6 II HR4110 CGI - REV C.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. 58705 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23359 R6 AE HR4110 Eng Eval CGI.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. 23359.3 SGD-4025A Window Non -Impact, Aluminum Sliding Glass Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23359 R6 II SGD-4025A-W CGI - REV A.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. PE-58705 Impact Resistant: No Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23359 R6 AE SGD4025A-W CGI - Eng Eval.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. 23359.4 SGD-4130A Window Impact Resistant, Aluminum Sliding Glass Window Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL23359 R6 II SGD-4130A Window - REV A.pdf Approved for use outside HVHZ: Yes Verified By: A. Lynn Miller, P.E. PE-58705 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL23359 R6 AE 4130 Window Eng Eval.pdf performance information, anchorage details, and anchor type, Created by Independent Third Party: No size, and spacing information. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®®®gi=® Credit Card Safe Engineering Evaluation Report # 4110-082820 Prepared by: A. Lynn Miller, P.E. 1070 Technology Dr. N. Venice, FL 34275 (941) 480-1600 Florida Registration: #29296 Manufacturer: CGI Windows and Doors 3780 W 104th St. Hialeah, FL 33018 Product Description: 4110A Series Impact -resistant Aluminum Horizontal Roller Window, (LM & SM), FL-23359 Compliance: The above -mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product listed herein complies with requirements of the current Florida Building Code. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). Supporting Technical Documentation: 1. Approval document: drawing number HR4110FLPA Rev C, signed and sealed by A. Lynn Miller, P.E. 2. Test Report(s) No. FTL 17-7535, 18-7858, & 20-2108.1-6, signed and sealed by Idalmis Ortega, P.E. Fenestration Testing Laboratories, Medley, FL 33166 TAS 201-94 Large Missile Impact Test TAS 202-94 Uniform Static Air Pressure Test TAS 203-94 Cyclic Pressure Loading Test 3. Anchor calculations, signed and sealed by A. Lynn Miller, P.E., dated 10/9/18 & 8/28/20. 4. Miami -Dade RER Product Control Section NOA's; PVB Interlayer by Kuraray America, Inc and Saflex PVB Interlayer by Eastman Chemical Company Limitations and Conditions of use: • Units must be glazed per ASTM E1300-09, refer to approval document for glazing details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame and sash material to be extruded Aluminum. • Units must be installed in accordance with approval document, HR4110FLPA. LYNN . �p ..... 4 't c * : No. 58705 U 9/3/2'0� — STATE OF /ONAX- ,E A. Lynn Miller, P.E. P.E. # 58705 SERIES 4110A IMPACT RESISTANT HORIZONTAL ROLLER WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3) MASONRY ANCHORS MAYBE USED INTO WOOD AS PER TABLE 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 6 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO OVE PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK HEIR DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 4) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5) SHIMS ARE REQUIRED AT EACH FLANGE ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 6) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WIND LOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. FLORIDA PRODUCT APPROVAL #23359 r 74" OVERALL WIDTH B 73" BUCK WIDTH B a C 3" RALL uHT 62" BUCK HEIGHT i 63" OVERALL HEIGHT 6 BU HEI ALWAYS 3" -- I— LAB 3-3/16" REQUIRED SEE NOTE D, THIS SHEET @ CORNERS TYP. XO ELEVATION (OX SIM.) USER INSTRUCTIONS: 1) DETERMINE THE SITE SPECIFIC, WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT USING WINDLOAD STANDARD ASCE 7. 2) KNOWING YOUR WINDOW CONFIGURATION (OX, XO, XOX), SIZE AND GLASS TYPE, DETERMINE YOUR WINDOW'S DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING USING TABLE 2. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. 3) DETERMINE THE MOST SUITABLE ANCHOR GROUP FROM TABLET ACCORDING TO THE INSTALLATION CONDITIONS. 4) DETERMINE THE ANCHOR QUANTITY FROM SHEET 2. VERIFY THAT THE ANCHOR/SUBSTRATE WILL MEET REQUIREMENTS FOR YOUR OPENING'S CONDITION FROM TABLE 1, AND THAT ALL MIN. REQUIREMENTS FROM THIS SHEET SET ARE MET. 5) INSTALL AS PER SHEET 3. GENERAL NOTES ............................1 ELEVATIONS....................................1 ANCHOR SPECIFICATIONS ............ 2 ANCHOR SPACINGIQUANTITIES...2 INSTALLATION ................................. 3 DESIGN PRESSURES ...................... 4 WEEPHOLE NOTES: GLAZING DETAILS .......................... 4 A. REQUIRED IF WINDOW WIDTH IS OVER 67". CORNER ASSEMBLY ...................... 5 B. REQUIRED IF WINDOW WIDTH IS OVER 45" AND UP TO 67". EXTRUSION PROFILES .................. 6 C. REQUIRED IF WINDOW WIDTH IS OVER 89". PARTS LIST ..................................... 6 D. REQUIRED IF WINDOW WIDTH IS OVER 45". DESIGN PRESSURE RATING IMPACT RATING VARIES, RATED FOR LARGE & SMALL SEE SHEET 4 MISSILE IMPACT RESISTANCE 111" OVERALL WIDTH 110" BUCK WIDTH B .r__ 7— A 2" / CK GHT L 'd— ALWAYS REQUIRED @ CORNERS SEE NOTE A, B THIS SHEET --I FF 3" TYP. XOX SEE NOTES B & C, THIS SHEET 1/3-1/3-1/3) ELEVATION 111" OVERALL WIDTH 110" BUCK WIDTH B A 63" OVERALL HEIGHT 6 BU HEI cr ALWAYS SEE NOTE A, g If 3-3/16" REQUIRED THIS SHEET SEE NOTES 3" @ CORNERS & C, THISS SHEET TYP. XOX (1/4-1/2-1/4) ELEVATION ADDED ULTRACON+ ANCHORS - JR - 08/27/20 \w jj .1///77 LYN/VMj� 49 /3/2�� - 0, •, STATE OF lJ ` A. LYNN MILLER, P.E. P.E.# 58705 111" OVERALL WIDTH 110" BUCK WIDTH B .r__ 7— A 2" / CK GHT L 'd— ALWAYS REQUIRED @ CORNERS SEE NOTE A, B THIS SHEET --I FF 3" TYP. XOX SEE NOTES B & C, THIS SHEET 1/3-1/3-1/3) ELEVATION 111" OVERALL WIDTH 110" BUCK WIDTH B A 63" OVERALL HEIGHT 6 BU HEI cr ALWAYS SEE NOTE A, g If 3-3/16" REQUIRED THIS SHEET SEE NOTES 3" @ CORNERS & C, THISS SHEET TYP. XOX (1/4-1/2-1/4) ELEVATION ADDED ULTRACON+ ANCHORS - JR - 08/27/20 \w jj .1///77 LYN/VMj� 49 /3/2�� - 0, •, STATE OF lJ ` A. LYNN MILLER, P.E. P.E.# 58705 'd— ALWAYS REQUIRED @ CORNERS SEE NOTE A, B THIS SHEET --I FF 3" TYP. XOX SEE NOTES B & C, THIS SHEET 1/3-1/3-1/3) ELEVATION 111" OVERALL WIDTH 110" BUCK WIDTH B A 63" OVERALL HEIGHT 6 BU HEI cr ALWAYS SEE NOTE A, g If 3-3/16" REQUIRED THIS SHEET SEE NOTES 3" @ CORNERS & C, THISS SHEET TYP. XOX (1/4-1/2-1/4) ELEVATION ADDED ULTRACON+ ANCHORS - JR - 08/27/20 \w jj .1///77 LYN/VMj� 49 /3/2�� - 0, •, STATE OF lJ ` A. LYNN MILLER, P.E. P.E.# 58705 A 9" MAX. — TABLE 1 74" OVERALL WIDTH 1 ANCHOR ON EACH SIDE OF 1 ANCHOR THE MEETING 1 1ANCHOR AT CORNER AT RAIL CORNER 56-9/16" / 57-13116" / / 9" MAX. I SASH FIXED VISIBLE 63' 15" MAX. OVER VISIBLE OC LIGHT LIGHT HEIG4 I 33-5/16" 33-5/16" SASH SASH VISIBLE VISIBLE LIGHT LIGHT f� _ 9 MAX. FROM CENTEP I—� OF MEETING RAIL TYP. XO ANCHORAGE (OX SIM.) & MAX. VISIBLE LIGHT OPENING 4LL IT 9" MAX. 11 1 15" MAX O.C. 9" MAX. I~ 9" MAX. FROM CENTER OF MEETING RAIL 111" OVERALL WIDTH 1ANCHOR @ MIDSPAN 1 ANCHOR ON 1 ANCHOR ON EACH SIDE OF EACH SIDE OF 1 ANCHOR AT THE MEETING THE MEETING 1 ANCHOR AT CORNER RAIL RAIL CORNER 63" OVERALL HEIGHT Anchor Type Frame Member Substrate Min. Edge Distance Min. O.C. Distance Min. Embedmentor Metal Thickness #12, Steel SMS (Gr. 5 or 410 SS, (min. of 3 threads beyond metal substrate) All Southern Pine (SG = 0.55) 9/16" 7/8" 1-3/8" 6063-T5Aluminum 3/8" 9/16" 0.060" A36 Steel 3/8" 9/16" 0.050" Gr. 33 Steel Stud 3/8" 9/16" 0.045" (20 Ga) UltraCon Elco ltr Jamb Hollow or Filled Block, (ASTM C90) 2-1/2" 6" 1-1/4" All Concrete (min. 2.85 ksi) 2-1/2" 4" 1-3/8" All Southern Pine (SG = 0.55) 1-1/16" 1-1/16" 13/8" 1/4" DeWalt UltraCon+ Jamb Hollow Block, (ASTM C90) 1-3/8" 6" 1-1/4" Jamb Filled Block, (ASTM C90) 1" 6" 1-3/4" All Concrete (min. 2.85 ksi) 1-1/4" 4" 1" All Southern Pine (SG = 0.55) 1" 1" 1-3/8" 1/4" 410 SS Elco CreteFlex@ Jamb Hollow or Filled Block, (ASTM C90) 1-3/4" 6" 1-1/4" All Concrete (min. 3.35 ksi) i 2-1/2" t 4" 1 1-3/4" IF THE FRAME CONTAINS A FACTORY COUNTERSINK, ONLY USE FLATHEAD ANCHORS AT THAT LOCATION. 33-5116" FIXED VISIBLE / LIGHT / 56-9/16" SASH VISIBLE 57-13/16" FIXED VISIBLE/ / LIGHT ��// LIGHT / 33-5/16" SASH VISIBLE LIGHT TYP. XOX (1/3-1/3-1/3) ANCHORAGE & MAX. VISIBLE LIGHT OPENING OVI HE 111"OVERALL WIDTH 2 ANCHORS 1 ANCHOR ON FOR FRAME 1 ANCHOR ON EACH SIDE OF WIDTHS EACH SIDE OF THE MEETING OVER, THE MEETING AND OVER, 1 ANCHOR RAIL OTHERWISE 1 RAIL 1 ANCHOR AT CORNER ANCHOR AT CORNER 63" 564/16" 57-13/16" °RALL SASH FIXED VISIBLE IGHT VISIBLE LIGHT LIGHT 24-5/8 " SASH SASH VISIBLE 50-3/8" FIXED LIGHT VISIBLE LIGHT / MAX. ~I I~ OF MEETING"RAIL TYP. XOX (1/4-1/2-1/4) ANCHORAGE & MAX. VISIBLE LIGHT OPENING 9" MAX. _ 1 15" MAX. O.C. LYN/V# * ; yNo. 5588705 ` •, y*� 0, •, STATE OF A. LYNN MILLER, P.E. P.E.# 58705 OVERALL HEIGHT EXTERIOR a LOCKS AT SASH SIDE RAIL OR 7 SHOWN EMBEDMENT ��MEETING RAIL 10 INSTALLED THRU EDGE DISTANCE �--�I 11 1X BUCKSTRIP "A— 24 DISTANCEFX EDGE30 X EMBEDMENT 101 EXTERIOR BUCK WIDTH OVERALL WIDTH SHOWN INSTALLED THRU 1X BUCKSTRIP VERTICAL SECTION B-B EMBEDMENT HORIZONTAL SECTION A -A #12 STEEL SELF DRILLING SMS (G5), SEE TABLE 1 #12 STEEL X SELF -DRILLING SMS (G5), SEE TABLE 1 oil h '01 Eli INSTALLED INTO v EXTERIOR APPROVED ALUMINUM, STEEL FRAMING OR STEEL STUD. BUCK WIDTH OVERALL WIDTH HORIZONTAL SECTION C-C MULLION SECTION APPROVED MULLION, MAY BE VERTICAL OR HORIZONTAL. NOTES: 1) USE ONLY SUBSTRATE APPROPRIATE ANCHORS LISTED IN TABLE 1. FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. 2) MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 1. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 3) SEE SHEET 2 & TABLE 1 FOR SPACING REQUIREMENTS. 4) MAX. SHIM THICKNESS TO BE 1/4". 5) GLASS SHOWN IS FOR ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER TO MEET DESIGN REQUIREMENTS. j EDGE DISTANCE * ; No. 58705 2� ���� •, STATE OF A. LYNN MILLER, P.E. P.E.# 58705 TABLE 2: DESIGN PRESSURE (PSf) o, .c 0 O ONerall Height 38-3/8" 43-1/2" 50-5/8" 63" Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 Glass Type 1 Glass Type 2 26-1/2" X 2 0 O X +55/-65 +55/-65 +55/55 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 37" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 45" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 49" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 53-1/8" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 61" +55/-65 +55/-65 +55/-65 +55/-65 +55/55 +55/-65 +55/-65 +55/-65 66" +55/55 +55/-65 +55/-65 +55/-65 +55/55 +55/-65 +55/-65 +55/-65 74" +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55/-65 +55.0/-63.2 +55/-65 w 53-1/8" <^o +55/-65 +55/-65 +55/-65 +55/-65 +55/55 +55/-65 +55/-65 +55/-65 — 61" M +55/55 +55/-65 +55/-65 +55/-65 +55/55 +55/-65 +55/-65 +55/-65 74" +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/-65 +55/-65 O 85" `�_ +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/-65 +55/-65 97" X O +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/-65 +55/-65 111" X +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55.0/-63.2 +55/-65 53-1/8" v +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/-65 +55/-65 74" N +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/54.8 +55/-65 85" +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +55/57.9 +55/-65 97" �_ +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +53.5/-53.5 +55/-65 109" X O +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +50.4/-50.4 +55/-65 111" X +55/-65 +55/-65 +55/55 +55/-65 +55/55 +55/55 +50/-50 1 +55/-65 5/16" NOM. GLASS STACK 1/8" ANNEALED GLASS .090" PVB 1/8" ANNEALED GLASS 5/16" LAMI. GLAZING GLASS TYPE 1 TABLE 3: 5/16" NOM. GLASS STACK 1/8" HEAT -STRENGTHENED GLASS 090" PVB 1/8" HEAT -STRENGTHENED GLASS 5/16" LAMI. GLAZING GLASS TYPE Laminated Glass Types 1 1/8" Annealed, 0.090" PVB, 1/8" Annealed 2 1/8" Heat -strengthened, 0.090" PVB, 1/8" Heat -strengthened INTERLAYER MAY BE SAFLEX PVB OR TROSIFOL PVB NOTES: 1) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. LYN/VM//" /'% �o * ; No. 5588705 ` •, y*� O 913/20 ���� •, STATE OF A. LYNN MILLER, P.E. P.E.# 58705 .330" .250" 1.600" O2 SILL 33 SILL ADAPTER WEEPHOLES WEEPHOLE DETAILS SHOWN WITHOUT WEEPHOLE COVERS. SEE SHEET 1 FOR QUANTITY AND SPACING ASSEMBLY DETAILS ILTA IA:01I►[ell II DOW-791, 899, 983 OR RGS-7700 BACKBEDDING 50 1/2" NOM. GLASS BITE EXTERIOR a TYP. GLAZING DETAIL * ; yNro. 5588705 ` •, y*� ���� •, STATE OF A. LYNN MILLER, P.E. P.E.# 58705 TABLE 4' Item Description 1 Frame Head 2 Frame Sill 3 Sill Adapter 4 Frame Jamb (Fixed) 5 Frame Jamb (Operable) 6 Heavy Duty Fixed Meeting Rail 7 Side Rail Lock 8 Sash Top & Bottom Rail 10 Sash Side Rail 11 Sash Meeting Rail 12 Dogbone Reinforcement 13 Sash Stop 23 .190" X.200" Q-Ion Wstp. (Frame) 24 .187" X.230" Fin Wstp. 25 Bulb Vinyl Wstp. (Sash) 26 Frame Sill Gasket, Polyethelyne, opt. 27 Frame Head Gasket, Polyethelyne, opt. 28 Sash Gasket, Polyethelyne, opt. 29 Weephole Cover 30 Sweep Latch 31 Roller Housing & Guide 32 Roller 33 Frame/Sash Comer Sealant, opt. 50 Setting Block 3/32" X 1/4" X 1" 70 Kommerling Kodispace 4SG TPS 2.000" - .oso" 2.009" .050" OFRAME HEAD 6063-T6 ALUMINUM OFRAME JAMB (OPERABLE) 6063-T6 ALUMINUM 1.932" 1.457" .062" 11 SASH MEETING RAIL 6063-T6 ALUMINUM 2.000" 2.824" .875" 2.610" .os2" OFRAME SILL O SILL ADAPTER STTUAMmINUM 6063-T6 ALUMINUM 1.845" .062" 2.010" .093" OHD FIXED MEETING RAIL 6063-T6 ALUMINUM r 1.115" 1- .062" J 12 DOGBONE REINFORCEMENT 6063-T6 ALUMINUM 8� .874 .062" 050" .926" 1.245" J OFRAME JAMB (FIXED) 6063-T6 ALUMINUM OSIDE RAIL LOCK O SASH TOP & BOTTOM RAIL 6063-T6 ALUMINUM r1.113" +� .781" 13 SASH STOP 6063-T6 ALUMINUM 735" .3'18" .065" iq LAMI. BEADING PVC 1.931" 6062-"1.853" 10 SASH SIDE RAIL 6063-T6 ALUMINUM LY .. y * ; No. 5588705 ` •, y*� O 913/20 0, •, STATE OF A. LYNN MILLER, P.E. P.E.# 58705