Loading...
HomeMy WebLinkAboutSewageSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMEI SYSTEM CONSTRUCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDSNew ` APPLICANT: (WJHFL,LLC) PROPERTY ADDRESS: 7004 Penny Ln Fort Pi! LOT: 9 BLOCK: 109 PROPERTY ID #: 1301-611-0187-000-7 SYSTEM MUST BE CONSTRUCTED IN 381.0065, F.S., AND CHAPTER 64E-6, SATISFACTORY PERFORMANCE FOR ANY WHICH SERVED AS A BASIS FOR ISSU PERMIT APPLICATION. SUCH MODIFICAT ISSUANCE OF THIS PERMIT DOES NOT STATE, OR LOCAL PERMITTING REQUIRED FOR SYSTEM DESIGN AND SPECIFICATIONS T [ 1,050 ] GALLONS / GPD S A [ ] GALLONS / GPD N [ ] GALLONS GREASE INTERCEPTOR C. K [ ] GALLONS DOSING TANK CAPACITY D [ 667 ] SQUARE FEET Drainfield R [ ) SQUARE FEET N/A A TYPE SYSTEM: [ ] STANDARD [ ] I CONFIGURATION: [ ] TRENCH [X] F N F LOCATION OF BENCHMARK: Site BM near SE p I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D FILL REQUIRED: 118.00] INCHES 0 T H E R t DIS M�V&U61/L PERMIT #: 56-SF-2216050 �j 8(;PPLICATION #: AP 1609184 �� ��J DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1497652 J L , F 34951 SUBDIVISION: Lakewood Park [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] R91MCE WI H SPECIFICATIONS AND STANDARDS OF SECTION �. DEP TMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE FI PERIOD OF TI ANY CHANGE IN MATERIAL FACTS, F THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE Y RESU T IN THIS PERMIT BEING MADE NULL AND VOID. :MPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, '+I MENT OF HIS PROP RTY. tic new CAPA�ITY N/b CAPACITY A ITY (MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] [ ] ALLONS [ ]DOSES PER 24 HRS #Pumps [ ] SYSTEM f SYSTE LL ED [XI MOUND [ ] )ei,ty corner at ifl.21.02 18�00 ] [ INCH S FT ] 181.00 ] [ INCH S FT ] LOVE BELOW] BENCHMARK/REFERENCE POINT LOVE BELOW]BENCHMARK/REFERENCE POINT 24.00 ] INCHES The system is sized for 4 bedrooms with a maximum c ccupancy of 3 persons (2 per bedroom), for a total estimated flow of. 400 gpd. SPECIFICATIONS BY: Ian Pj Moore APPROVED BY: DATE ISSUED: 01/08/2021 DR 4016, 08/09 (Obsoletes all previous Incorporated: 64E-6.003, FAC v a.i.a TITLE: EHP 17-2072 Environmental St. Lucie CHD EXPIRATION DATE: 07/10/2022 which may not be used) Page 1 of`"� 1 P1 n(; 92. as 5ESi55a73 A party whose substantial interest is affected by this order administrative hearing pursuant to sectio s 120.569 an 120.57, 1 proceedings are governed by Rule 28-105, Florida Adm nistrative administrative hearing must be in writing nd must be rE ceived by Department, within twenty-one (21) days from the recei t of this o Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Clerk's facsimile number is 850-413-874 3 . iay petition for an )rids Statutes. Such ode. A petition for ie Agency Clerk for the er. The address of the orida 32399. The Agency Mediation is not available as an alter ative remedy. Your failure to submit a petition foIr h laring withi 21 days rom receipt of this order will constitute a waiver of your right to an admini trative hearing, and t is order shall become a 'final order. Should this order become a final order, a party who is advi to judicial review pursuant to Section 120,68,�Florida St tutes. Re governed by the Florida Rules of Appella{e P ocedure. 3uchproc by filing one copy of a Notice of Appeal v ith the Agency Clerk of tl second copy, accompanied by the filing fees equired b law, with appropriate District Court. The notice rn Ist b filed with�n 30 days rsely affected by it is entitled view proceedings are .edings may be commenced e Department of Health and a he Court of Appeal in the of rendition of the final order. i St. Lucie FORA 5150 NWMilner HEALTH County Health Dr Dep Port Saint rtment Lucie, FL 34983 'AY _ ING ON: #: 56 SF-2216050 BILL roc RECEIVED FROM: A Reliable Treasure Coast 'AYMENT FORM: CHECK 9507 # 56-BID-51 2573 CONSTRUCTION APPLICATION #: AP1609184 I Si6rvices MOUNT PAID: $ 430.00 AYMENT DATE: 12/23/2020 1 MAIL TO: (WJHFL, LLC) f t :ACILITY NAME: I 'ROPERTY LOCATION: 7004 Penny Ln Fort Pierce, FL 34951 9 Lot: Block: 109 Property ID: 1301-611-0187-000-7 RI TION: EXPLANATION or DES QUANTITY FEE 1 $ 5.00 128 - OSTDS Construction System Inspection esE arch Fee -1 - Surcharge (All) 1 $ 45.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Revi w,New 1 $ 100.00 126 - OSTDS Construction Permit (New or Mod A endment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 RECEIVED BY: WhighamJL 1 AUDIT CONTROL NO. 56-PID-4835391 i I STATE OF FLORIDA DEPARTMENT OF HEAL ONSITE SEWAGE TREA H ME T AND DISPOSAL PERMIT NO. SE—;Altooso DATE PAID: Zs FEE PAID: .� SYSTEM cop RECEIPT # : Nei' APPLICATION FOR CO ST UCTION PERMIT PPLICATION FOR: [✓] New System [ ] Existing [ ] Repair [ ] Abandonment System [ ] H [ ] Temporary ldin Tank g I ] Innovative [ ] APPLICANT: WJHFL LLC AGENT: Reliable Treasure Coast Services Indian Ri er S Ptic TELEPHONE: 772-562-4242 MAILING ADDRESS: P.O. Box 1116, Vero Beach�L 2961 TO BE COMPLETED BY APPLICANT OR APPLI BY A PERSON LICENSED PURSUANT TO 489*0�TIS APPLICANT'S RESPONSIBILITY TO PROVIDEDCUMENTATION PLATTED (MM/DD/YY) IF REQUESTING CON ID AUT (3)(m) RATION OF ORIZED AGENT. R 489.55�, OF THE STATUTIPRY SYSTEMS MIIST BE CONSTRIICTED FLORIDA STATUTES. IT IS THE DATE THE LOT WAS CREATED OR GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 9 BLOCK: 109 SUBDIVISION LAKEWOOD PARK�Unit 9 PLATTED: Pre-72 PROPERTY ID #: 1301-611-0187-000-7 PROPERTY SIZE: 0.27 ACRES WATER SURP ZON Y: [ ✓] NG: RS�4 RIVATE I M T / OR EQUIVALENT: [ NO � ] I PUBLIC [ ]<=2000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No 0 DISTANCE TO SEWER: N/A FT PROPERTY ADDRESS: 7004 PENNY LN FORT PIER E, FL 3495 f DIRECTIONS TO PROPERTY: I BUILDING INFORMATION [✓] RESID NTIAL [ ] COMMERCIAL Unit Type of No. of No Establishment Bedrooms Buildin Area S Comme t Table cial/Institutional System Design 1 Chapter 64E-6 FAC 1 Single Family 4 1650 2 3 4 th I ] Floor/Equi a rains [ ] r (Specify) SIGNATURE: DAME : 12-17-20 DH 4015, 08/09 (Obsoletes previous ed Incorporated 64E-6.001, FAC ti ns whic may not be used) Page 1 of 4 La rt+E STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT SITE EVALUATION AND SYS APPLICANT • WJHFL LLC LOT: 9 BLOCK: 109 SUBDIVISION: PROPERTY ID # : 1301-611-0187-000-7 � AND DI EM SPE POSAL IFICATIONS AGEN WOOD PARK PERMIT # . ZC SYSTEM : Reliable e able Treasure Coast Services Indian River Septic Unit 9 LAKE [Tax ID Num er Ell TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT MUST PROVIDE REGISTRATION NUMBER AND S1GN EMP AND SEAL OYEE,OR EACH PAGE OTHER QUALIFIED PERSON. ENGINEERS OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓jj] TOTAL ESTIMATED SEWAGE FLOW: 400 AUTHORIZED SEWAGE FLOW: 405 UNOBSTRUCTED AREA AVAILABLE: 750 BENCHMARK/REFERENCE POINT LOCATION: Site ELEVATION OF PROPOSED SYSTEM SITE IS181 THE MINIMUM SETBACK WHICH CAN BE MAINT SURFACE WATER: N/A FT DITCHES/ WELLS: PUBLIC : N/A FT LIMITED USE BUILDING FOUNDATIONS:5 FT SITE SUBJECT TO FREQUENT FLOODING: [ ] 10 YEAR FLOOD ELEVATION FOR SITE: SOIL PROFILE INFORMATION SITE 1 j S [ ] ( GALLONS I GALLONS 1 SQFT I ear South ef 90 NET PER DAY PER DAY UNOBSTRUCTED st property USABLE AREA AVAILABLE: .27 ACRES [RESIDENCES -TABLET m] [ 1500 GPD/ACRE El] AREA REQUIRED: 750 SQFT corner at EL: 21.02 j BM INI MIT I 1 [INCHES D FROM THE WALES:N/A FT LI [✓] NO FT MS I I I I j E]] [A PROPO OVE 0NOHMMARR%REFERENCE POINT ] `lBE ED SYSTEM TO THE FOLLOWING FEATURES FT NORMALLY WET? [ ] YES [✓] NO E : 94 FT NON -POTABLE: N/A FT FT POTABLE WATER LINES:57 FT 10 YEAR FLOODING? [ ] YES IV] NO SITE ELEVATION: FT MSL/NGVD FILE INFORMATION SITE 2 PRIV S:12 /NGVD SOIL PR PROPERTY YES MUNSELL #/COLOR TEXTURE DEPTH 1 OYR 4/1 S 0 TO IOYR 511 S 24 TO 1 OYR 2/1 Spodic 30 TO IOYR 3/6 FS 38 TO 10YR 5/4 FS 43 TO Refusal A 56 TO TO TO TO USDA SOIL SERIES: Eaugallie FS Like 3 0 MUNSELL #/COLOR TEXTURE DEPTH S 0 TO 34 S 26 TO 34 Soodic 34 TO 40 FS 40 TO 47 FS 47 TO 59 Refusal (a, 59 TO TO TO TO IL SERIES : Eauaallie FS Like 1 OYR 4/1 30 I OYR 511 38 1OYR 2/1 43 10YR 3/6 56 10YR 5/4 ] USDA S OBSERVED WATER TABLE:39 INCHES [BELOW ESTIMATED WET SEASON WATER TABLE ELEVATiON:24 HIGH WATER TABLE VEGETATION: [ ] YES [�] SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING:Sand/.8 DRAINFIELD CONFIGURATION: [✓] TRENCH REMARKS/ADDITIONAL CRITERIA: SHS determined due to saturation in both sites. ] i [ by ]'] EXIST INCHES MOTTLING: NG GRADE. TYPE: [APPARENT Ell [.BELOW Ell EXISTING GRADE [✓] YES [ ] NO DEPTH:24 INCHES DEPTH OF EXCAVATION:40 INCHES (SPECIFY) in a IOYR 4/1 matrix at 24 inches in site 1. Refusal NO BED 10% 10YR [ ] OTHER 511 strippin I BM: 37 S1: 2'1 S2: 2'1 I SITE EVALUATED BY: Ian Moore C.E.H.P. 19-2072 DH 4015, 08/09 (Obsoletes previous editions which DATE: 12/17/20 ted: 64E-6.001, FAC Page 3 of 4 may f 4 � � not be us I d) Incorpor r:_:':WRVEY-:-' CONSULTANTS/ J 1 1, SITE LEGAL DESCRIPTION LOT 9 BLOCK 109 0 15 30 LAKEWOOD PARK, UNIT 9 AS RECORDED IN PLAT BOOK it PAGES 27D 1 INCH = 30 FEET PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA. LOT 19 IMPROVED -- FIR 5/8" W 'l N � CIO yti CO - LOT 8 X FFE- 23.47' LOT 18 FFE-24.79' 8•89029'27"E(M),"" 90.24'(M) S89°56'20"E(P),° 90.00'(P) Do' i � o o �Ce) ryry. O D ry X M M ,. 15.00' Df<^;11�1i I�LD _�._.. ......... 89.72'(M) FIR 5/8" 90.00'(P) SIR 5/8" "LB 7.& -- V, 12X17" CMP, -{ S8 LOT 17 IMPROVED 0 X�1 5/8" 7821" 10.)e' P.U.D.E. ' — — — — — X",. — — — — _ _ _ PROPOSED WELL / s M c' LOT 9 BLOCK 109 o' 'rl CONC / 36.6T 4 ry��� aox 'Cy) co 0 ; LOT 10 VACANT J o o C BLOCK 109 PROPOSED CO!_, 1-STORY RESIDENCE. 4 Ul FFE: XX.XxI\I' �' a -C) y Ox �03.7`o I 20.3' ri 14.3' C� CO +11 CONC SW U f. 9! (O G;;L o Lq o rr,r_ I U L -z _.._..... - --- --.._...9 n UU 750 SQFT 16.0' tiUNOBSTRUCTED AREA ;; SIR 58" FIR / A 31 6'20" (P&M),,q' 90.00'(P) t - 90.00'(P&M) -0�89.72'(M) FND NAIL BM � 55.0' R/W (P) ;, FND NAIL BM ELV=20.81' „ ° ST. LUCIE AVENU5,' ✓(P)_ 'y ELV=21.02' - PENNY LANE WELLS OUT OF RANGE MODEL: LOT SIZE: = PROPOSED DRAINAGE 1650-B LG / 11,700 SQFT ARROW BOUNDARY SURVEY CERTIFIED TO: PROPERTY ADDRESS: Y4 x�� = GROUND ELEVATION CENTURY COMPLETE 7004 PENNY LANE 23.4 =PROPOSED ELEVATION FORT PIERCE, FL = PROPOSED CORRUGATED METAL PIPE LEGEND & ABBREVIATIONS k SURVEYOR'S NOTES I HEREBY CERTIFY THAT THIS SURVEY IS PSM = PROFESSIONAL SURVEYOR & 1. BASIS OF BEARING - THE SOUTHERLY LINE OF, LOT 9 BLOCK 109, LAKEWOOD TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE, AND THAT THIS SURVEY MAPPER LB = LCENSED BUSINESS PARK, UNIT 9, AS RECORDED IN PLAT BOOK 11 PAGES 27D PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA, AS BEING S89-56-20"E AS A PLAT. MEETS THE STANDARDS OF PRACTICE AS LS = LICENSED SURVEYOR REQUIRED BY CHAPTER 5J-17 FLORIDA FND = FOUND 2. DATE OF FIELD SURVEY: 10/8/2020. BOARD OF LAND SURVEYORS PURSUANT SET = SET "LB 7821" TO SECTION 472.027 FLORIDA STATUTES. IRC = IRON ROD & CAP 3. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE N/D =NAIL &DISK PARTY ORPARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE CMON= CONCRETE MONUMENT SIGNING DIN = DRIVEWAY SW = SIDEWALK 4. PROPERTY LINES SHOULD NOT BE ESTABLISHED USING FENCE OR BUILDING TIES. EC CONCRETE EP = PAVEMENT 5. NO UNDERGROUND INSTALLATIONS OR IMPROVEMENTS, INCLUDING BUT NOT = R/W RIGHT-OF-WAY LIMITED TO, BURIED UTILITIES, FOUNDATIONS AND FOOTERS WERE LOCATED. COV = COVERED 11c = AIR CONDITIONER (3.5'x3.5' PAD) 6. BASED UPON MY REVIEW OF THE "FLOOD INSURANCE RATE MAP" OF SAINT LUCIE COUNTY, FLORIDA, COMMUNITY PANEL NO.1211100070J, EFFECTIVE DATE 2/16/2012, D.E. = DRAINAGE EASEMENT "X", U.E. = UTILITY EASEMENT THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE DEFINED AS AREAS WBF = WOOD BOARD FENCE DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN. CLF CHAIN LINK FENCE WVF = WHITE VINYL FENCE 7. NO INSTRUMENTS OF RECORD REFLECTING OWNERSHIP OR ENCUMBRANCES WERE PROVIDED, EXCEPT AS NOTED, NOR DID THIS SURVEYOR ABSTRACT THESE LANDS. (P) = PLAT M MEASURED 8. SURVEY FILE NUMBER: 20-10-007 gefN W HOLLOWA , P.S.M. LS 6676 ® = WATER METER 9. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL H&H SURVEY CONSULTANTS, LLC LB 7821 ® = CABLE RISER DATUM OF 1988 (NAVD88), AND MORE SPECIFICALLY TO THE FLORIDA PERMANENT ® = TELEPHONE RISER REFERENCE NETWORK (FPRN) CONTINUOUSLY OPERATING REFERENCE STATIONS NOT VAUD NITHOUT THE SIGNATURE AND THE ORIGINAL ® = ELECTRIC RISER (CORS) FLFR, FLFD & STEW. RAISED SEAL OF A FLORIDA LICENSED SURVEYOR c0� = POWER POLE I I DATE OF SURVEY: October 14, 2020 131 W Broadway, Suite 1001, Oviedo, FL 32765 www.hnhsurvey.com 407.542.4977 I WALL LEGEND FULL HEIGITB'CA.U. WALL FULL HEIGHT M MOO STUD PARTITION FULL HEIGHT SIOPNHT 2XWOODSTUDPARTRON AS NOTED ONPLA,d'HDR HT. STONEVENEER BNCKVENEER — — — — — — 1 ROD ISH,ELF STUD WALL BELOW NOTE, EOERORWALLS FRAMEDAT 16' D.C.NTEROR NON. HEIGHT AND STUD SIZE ASNOTED BEARING WALLS FRAMED AT 24'O.C.REFTOSTRUCTURALSHEETS PLAN NOTES 1. VERIFY ROUGH OPENING DIMENSIONS FOR ALL WINDOWS &DOORS. Z PROVIDE SAFETY GLAZING WITHIN 24'FROMDOT PER FLORIDABUILDINGCODER3GB.41 3. PROVIDE SAFETYGLAi1NGATBATHISHOWER PER FLORIDA BUILDING CODE R3064S 4. NON BEARING INTERIOR FRAME WALLS SHALL BE FRAMED 9WOOD ORLETALSTUDS.SPACING SHALL NOT EXCEED24' O.C.(NON BEARING WALLS ONLI S. PRONE DEADWOOD NARICFDROVERHEADGARAGEDOOR HARDWARE 6. WHERE DRYWALL CEILING ISAPPLIED TOTRUSSES@24'O.C,USEITDRYWAROR117SAG RESISTANT PER SEC.70231 7. THE GARAGE SHALL BE SEPARATED FROhITHERESIDENCE IATTIC BYNOT LESS THAN 1Tf GYPSUM BOARD APPLIED TO THE GARAGE SIDE GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED WITH NOT LESS THAN STTYPE x GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION LS A ROORCEILING ASSEMBLY. THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN tTGYPSUM BOARD OR EQUIVALENT. & INSTALL 13? THICK SOLID WOOD DOOR BETWEEN LIVING & GARAGE PER FLORIDA BUILDING CODE R30Z1 S 9. ALL WINDOWS INSTALLED 77 A30VE GRADE MUST COMPLY WITH R6122 MIN. 2411.1. HEIGHT OR PROVIDED WITH AN APPROVED WINDOW FALL PREVENTION DEVICE. 10. PROVIDE FIRE BLOCIONG PER SECTION R302.11 11. PROVIDE CRAFT STOPPING PER SECTION 16O12 -4.. TABLE R3M Dd-%'GargSsparAn I'm tlersdmsaI3b Na(Lai4uil ndgloumbalveTiu&9 appfadto Ile g ag:4d: Fir a]habiahl?rooms toaInepap Nolbsth 5 A-rchType%gyp?jmboil Of epdni Stm&151suppatiglbrA9ass 14 Not bst1alYrirO;pp b3l zxdLot Sepriuo-4ed7ythswton IseT v3Mm 298 DOOR WITOP & BOTTOM LOWERED DOOR SQUARE FOOTAGE 16S1SOFT. DOORSTYLES&RAtS •7.05SOFT. LOUVERSIM'xT-Tx6S •1.02SOFT. NETOPENAIRROW HOSOFT. �A9 u agmxo .ui HIPuoupedeo ePPOIJ .pawift :a3eA f21� i xdl ��- REM ■ill !i 0 II 1 !1 1i BED 4 F 0 I�� psi • Jir �i PER RMil OF THE CODE Z 2-CAR GARAGE ♦ •. ►� i ►i x ►i 1. ♦ f G B. ►. x ff x x 1 f FIRST FLOOR PLAN ELEV ? 114°: V TAT 22" X 34- LAYOUT l 118": V-0" AT 11n X 17° LAYOUT Wo-cq}. A-/L c COLUMN 1111►IIII1II1 CENTURY MORE HOME • LESS MONEY 3091 GOVERNORS LAKE DR. SUITE 300 NORCROSS, GA 30071 PHONE: 336-282-3606 W1H,lLC®2010 m f.rlo Z Q J d IC= Li. tt O c u c ; 0 o �'L C o z x a o o a o C L p— PLAN # / ORIENTATION 1612 BLK / LH SERIES NAME: DIAMOND PLAN NAME: 3911650 LAST REVISION 2.02 SHEET # GRPZ 1.2