HomeMy WebLinkAboutConstruction PlansFA
0
E1.- APPROVED PRODUCTS LIST
MAXIMUM ALLOWABLE
- WIND. SPEED
QA
APPROVAL
EXPIRATION
PARTIALLY
PRODUCT CATEGORY
SUB CATEGORY
MANUFACTURER
No. & DATE
DATE
OPEN
ENCLOSED
ENCLOSED
STRUCTURAL COMPONENTS
ROOF DECK
CAROLINA CARPORTS, INC.
FL6596A-R5
04/05/27
180
180
18Q
26 Gauge AG Panel
10/16/17
STRUCTURAL COMPONENTS
STRUCTURAL WALL
'CAROLINA CARPORTS, INC.
FL6702.1-R5
03/14/21
180
180
180
26 Gauge AG Panel
10110/17
STRUCTURAL COMPONENTS
FLOOD VENT
CRAWL SPACE DOOR SYSTEMS,: INC.
FL29622.1
09/01120
N/A
N/A
N/A
16x8 Flood Vent
05115/19
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL17996.3-R1
09/.14/20
N/A
139
138
Series 402-14
01/29/18
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL17996.5-R1
.09/14/20
N/A
165
141
Series 407
01/29/18
EXTERIOR DOORS
ROLL -UP
ASTA INDUSTRIES INC.
FL8888.1-R5,
12/31/20
N/A
180
174
Model 203 (12' Max. Width)
10/07/17
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
FL16806.1-R4
11/11/20
N/A
158
138
Steel Roll Up Sheet Door (12' Max. Width)
06/18/19
WINDOWS
SINGLE HUNG
MI WINDOWS -AND DOORS
FL17499.1-R5
10/17/23
N/A
176
157
Model 185 SH
03/27/19
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
FL16806.2-R4
11/11/20
N/A
180
180
Steel Roll -Up Sheet Door - 8' Wide
06/18/19
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
FL16806.4-R4
11/11/20
N/A
180
172
Steel Roll -Up Sheet Door -1V Wide
06/18/10
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
FL16806.3-R4
11/11/20
NIA
155
133
Steel Roll -Up Sheet Door -16' Wide
06/18/19
1. DOORS AND WINDOWS SHOWN MAYBE SUBSTITUTED FOR DIFFERENT PRODUCT LINES ANDIOR MODELS. PROVIDED THE FOLLOWING CONDITIONS ARE MET:
A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL.
B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REOURIEMENTS.
2. FRA13ING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE
S U BSTIT U TED' PRODU CT.
TABLE 9
RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR,
MAXIMUM PURLINS, AND POSTS OR GIRTS
WIND
ULTIMATE NOMINAL POST / RAFTER (INCHES)
RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END
CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTSIRAFTERS
110 TO 150 89 TO 116 5;0 6 6
I C
151 TO 180 117 TO 139 4.0 6 6
'NOTES: 1. Specifications applicable to 26-gauge metal -roof and wall panels fastened directly to 12 oY14 gauge steel tube framing, or 18
gauge hat channel roof puriins.
2. Specifications applicable. only for mean roof height of 20 feet or less, and roof slopes 6Y7" to 27" (1.5:12 to 6:12 pitch). Spacing
requirements for other roof -heights and/or slopes may vary.
GROUND ANCHOR SCHEDULE
ULTIMATE WIND SPEED (mph) METAL CARPORT INSTALLATION PLANS
910 120 130 140 150 160 170 180 AND DETAILS AND FRAMING AND
12
14
30' Anchor
16
Detail iD
18
o'
20
48`Anchor
�
22
Detail IC
z
0
24
J
26
m
"<
28
60' Ancho
30
Detail 10
x
DETAILS 1C AND I SHOWN ON SHEET 4 OF,6
GENERAL NOTES:
1, THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO
PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY-S.ET-BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER.LOCAL- ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITYISTORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OPSUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS
NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS,
INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.,�SHALL NOT BE RESPONSIBLE FOR.STRUCTURAL DAMGE OR FAIL -LIRE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3, ALL STEEL TUBING SHALL BE 50 KSI-GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
4, ALL COMPONENTS AND CLADDING. SHALL BE INSTALLEDACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE
LOCATION OF THE BUILDING -WITHIN THE STATE OF FLORIDA.
5, ALL FIELD FRAMING CONNECTIONS.SHALL BE #12-14 x.3/4' SELF DRILLING SCREWS: WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVESTRENGTH OF 2500'PSI AT 28 DAYS. THE REINFORCING STEEL SHALL,BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4
WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION; AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT RE ED.FOR CONCRETE FOOTING
AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. 1 Z upQ�!
8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2" x 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. py�7r
9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS.
10. SLA13 FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) - RESIDENTIAL, AN 6 �E) VE�F.BGS FH
EDITION (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. �1 Ij g7E�
11. 14 GA FRAMING: 2-1/2" x 2-1/2"TUBE STEEL (TS) WITH 2-1/4' x 2-1/4" TS NIPPLES. ®®E C-0 "° P'L1+�"T V4 c s
12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES. ST LUCU im: Cyr u a 8
12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED E, T ASE OF is
SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC.APPROVED PRODUCTS LIST SHALL BE BASED Ot�, (t),FgQOD VENT PER
EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6.
FASTENER SPECIFICATIONS
FOR CONSTRUCTION IN THE STATE OF FLORIDA
PREPARED FOR.
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON NORTH CAROLINA 27017
PREPARED BY:
BECHTOL ENGINEERING AND TESTING, INC.
605 WEST NEW YORKAVENUE
DELAND, FLORIDA 32720
Certificate.of Authorization No. 00005492
THIS IS TO CERTIFY THATTHE CALCULATIONSAND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609OF
THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS
ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING
CODE,
\\\�\t'11111111IAj77
13
DEtZtN OR►DA 3272 - j
Ttiana lwt .E. 01
FlorldSso'
S! o N A,-
Wei
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
_ '� `"` 01/20/20
-J BECHTOL ENGINEERING mkb ""E NTS
AMTES TING, rna
onairrrictartat�v+ MTV4 0ALAWituc_vAn=ncw�n lb G20001
C.V 'd *" R,000= ' TB SHEET 1 OF 6
13OW FRAME RAFTER OPEN CARPORT - H0917-ONTAL ROOF BOW FRAME RAFTER ENCLOSED 13UILDING - HOR17-ONTAL ROOF
BOW FRAME RAFTERUTILITY BUILDING - HORIZONTAL ROOF
TYPICAL SIDEELEVATION
NOT TOSCALE
TYPICAL END ELEVATION
NOT TO SCALE
,_1
Iff-OX-E6V-CM 'F-RAF-TER-01:i E F
TYPICAL SIDE ELEVATION
NOT TO SCALE:
TYPICAL END ELEVATION
NOT TO SCALE
BOX- EAVE FRAME, RAFTER OPEN CARPORT - VERTICAL ROOF
;:i nnn %IrMT fA . . . R—h-M
TYPICAL SIDE ELEVATION
NOT TO SCALE
ROLL -UP DOOR SWINGING DOOR
TYPICAL END ELEVATION
NOT TO SCALE
-------------- — - . - —j
WOX�-P-AVE'-TER-ENC-LOSEDB� -L,.D Gw-'0-1R"r0N-T'AL---M0-JOF
TYPICAL SIDE ELEVATION
NOT TO SCALE
ROLL -UP DOOR SWINGING DOOR
(As applicable). (AsapplIcable)
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTER ENCLOSED BLDG VERTICAL ROOF
ENCLOSED LEt.GTH VARIES
TYPICAL SIDE ELEVATION
NOT TO SCALE
-
ROLL-UPDOOR SWINGING DOOR
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTERL' UTILITY BLDG - HORIZONTAL ROOF
ROLL -UP DOOR SWINGING DOOR
(As applicable) - (As applidaNs) -
I -W
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOT TO SCALE
BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF
ROLL -UP DOOR SWINGING DOOR
TYPICAL SIDE ELEVATION TYPICAL END' ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL sib[H'ELEVATIOW TYPICAL END ELEVATION
NOTTO SCALE NOT TO SCALE NOT TO SCALE NOTTOSCALE NOT TO SCALE NOT TO SCALE
\o\'\01
1�111il11
1
B E68TING, INC.
sos 14 YORKAVENUE
2!rWica papof
op
No.
REVIEWED FOR c R 0, L, "J'NAO 40 b R T S, INC.
CODE COMPLIANCE GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
rm TYPICAL BOW RAFTER GABLE END ELEVATION 1— 01120120
TYPICAL BOX A-110N
BECHTOL ENGINEERING =Mkb NTS
NOT TO SCALE NOT TO SCALE B O C C __j AND 7E817AIG, Ina tb FM ".opaunq .
G200011
=&m1zmj1 AM mm" "3TM IN TB SHEET 2OF6
26 GA. GALVANIZED METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS'
12
-j3
24.16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) # 12-14 x 3/4- SDFs AT
EACH END (4 PER BRACE)
24' IAAXi'!UM RAFTER SPAN ON S=;LE RAFTER
>24'TO.19 RAFTER'SMI REOU;RES A TRUSSED RAFTER
TYPICAL
INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME
NOT TO SCALE
LENGTH VARIES DEPENDING ON
NUMBER AND.SPACING OF RAFTERS
SEE
TABLE 1
SHEET
3 ..1oFs
a
TYPICAL RAFTER/POST FRAMINGPLAN - BOW FRAME
NOT TO SCALE
OPTIONAL 24'-1." TO 30` TRUSSED RAFTER - BOW
NOTTOSCALE
26 GA. GALVANIZED METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
12
�3
24' 16 GA U•CHANNEL BRACE
FASTENED TO RAFTERWITH
(2) # 12-14 x 3/4' SDFS AT
EACH END (4 PER BRACE)
24'?AAX(L!Uta RAFTER SPAN ON SLUGLE RAFTER
,24' TO 3T RAFTER SPAT! REQUIRES A TRUSSED: RAFTER
AS SHO47N ON THIS SHEET
TYPIC � NTE AOR-sRA TER/POST
RAMS SECTION--BOX,-EgVE-.HORIZONTALROOF
LENGTH VARIES DEPENDING ON
NUMBER AND SPACING OF RAFTERS:
SEE
TABLE.1
SHEET
a 10F6
a
-~ QXRICAL RAFTERMOS,ff-- - AMIR-G:liIJ=NN -8 X�EAVE
SEE
TABLE 1
SHEET
26 GA. GALVANIZED METAL ROOF PANELS
FASTENED TO PURLINS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
18 GAUGE FURRING
NEL(PURLIN)
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 314' SDFsAT
EACH END (4 PER BRACE)
24' Ft VIMU! S RAFTER SPAN ONSNGLE RAFTER
>24- TO N RAFTER SPAR REOUIRRES A TRUSSED RAFTER
TYPICAL INTERIOR
RAFTER/POST FRAME,SECTION = VERTICAL ROOF
NOT TO SCALE
1.1/2' 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) 02.14 x3/4- SELF -DRILLING
FASTENER SPACED NOT MORE THAN 48 O C.'
3
4
SEE
TABLE 1
SHEET
10F6
LENG VARIES DEPENDING ON NUMBER
AND SPACING OF RAFTERS
TYPICAL
POST/RAFTER"FRAMING PLAN - VERTICAL ROOF
NOT TO SCALE
TYPICAL
END -WALL OPENINGS POST/RAFTER FRAMING PLAN
NOT TO SCALE
TYPICAL BOW RAFTER GABLE END FRAMING PLAN'
NOT TO SCALE
TYPICAL BOX EAVE RAFTER'.GABLE END FRAMING PLAN
NOT TO SCALE
(2) #12-14 z314'_SELF-D
SCREWS AT EACH END
(4.P.ER BRACE)°
ROOF EXTENSION -OPTION MAIN STRUCTURE 8TANDARD LEAN-TO OPTION
TYPICAL LEAN-TO. OPTIONS FRAMING PLAN (BOTH OPTIONS SHOWN) -
NOT TO SCALE (BOX EAVE.RAFTER SHOWN, ONLY STANDARD LEAN,TO IS APPLICABLE TO BOW FRN.IE RAFTER)
.tt]III11'//,.
24- 16 GA U=CHANNEL BRACE (6 TO T POST)
48- 16 GA U-CHANNEL BRACE (8'TO 14'POST) IN
BRACE ANGLE SHALL BE MIN.30'
LD TO MAXI 45' FROM HORIZONTAL O�1•
FULL.6' WELD
BOTH SIDES
6'
4 1
I_ -5 RED I- MVED FOR
WELD ALL WEB CONNECTIONS, Yd�
CODE PMPUANCE.
BOTH SIDES
�i. m
FREy4NF_NG
ORTtO'N1 4�03D RIfSSED'R�CTE,f37C?E=AVE LEA zOi"II��iA4MING PLAN
NOT TO SCALE
INSTALL "112' x MINIMUM 6' TAPCON REDHEAD LDT INSTALL 112' x MINIMUM 6' TAPCON REDHEAD LDT
ANCHOR OR 1/2- X MINIMUM 5.1/2' EXPANSION ANCHOR ANCHOR OR 112' x MINIMUM 6-1/2' EXPANSION ANCHOR DRILL 518' HOLE THROUGH THE 2' WASHERS DRILL 5/8' HOLE THROUGH THE 2` WASHERS
THROUGH BASE RAIL WITHIN 6' OF EACH THROUGH BASE RAIL WITHIN 6' OF EACH BASE RAIL'AND SECURE TO BASE RAIL AND SECURE TO
RAFTER POSTS ALONG SIDES AND EVERY END RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 1/2" DIAMETER TS CONTINUOUS ANCHOR EYE WITH. m-DIAMETER TS CONTINUOUS
WALL POST ALONG END WALL -SECTIONS WALL POST ALONG END' WALL SECTIONS THROUGH -BOLT BASE RAIL THROUGH -BOLT BASE
f11NIIdU11 2'MINIMUM (•� MIN. 8' TOP OF ASPHALT PAVEMENT- TOP OF ASPHALT PAVEMENT
OR STABLE GROUND SURFACE OR STABLEGROUNDSURFACE
iMINIMUM.2-11/r EMBEDMENT MINIMUM 2-1/2' EMBEDMENT
EYE ANCHOR
T.i 5/8' ROD 48' LONG
` WITH WHELIX
_ 12' OR
5/8' ROD 60' LONG (SEE, GROUND ANCHOR EYE ANCHOR (SEE GROUND ANCHOR
j 'b 4. 'MINIFM IM 4' WITH 7' HELIX, SCHEDULE, SHEET 1 OF 6, 5/8' ROD 30' LONG SCHEDULE, SHEET I OF 6,
AS APPLICABLE FOR APPLICABILITY) WITH DBL 4' HELIX FOR APPLICABILITY)
12' ZC6NTINU.OUS4"CONCRETEPAVEI.ItUr
MONOLITHIC.CONC. FOOTING (2500 PSFMIN.)
REINFORCED WITH 2 #5'S CONTINUOUS
N,C AS'E CtAl1�-ANCLI;� fQ;E
DRILL 518' HOLE THROUGH THE 2` WASHERS
BASE RAIL AND SECURE TO
ANCHOREYE WITH .112' DUWETER fj j' TS CONTINUOUS
THROUGH -BOLT / BASE RAIL
(SEE GROUND ANCHOR
MINUdUft 4' SCHEDULE; SHEET 1 OF 6.
FOR REQUIRED ANCHOR)
ZCOtiTINUOUS 4'
CONCRETE PAVEMENT
EYE ANCHOR'
CONCRETE BASE RAIL ANCHORAGE
Not To Sw:e (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT
I.1EET t.0til tUI.I EOGE'DISTANCESHOVIN IN DETAIL 18)
TS TRUSSED RAFTER
OR NON-STRUCTURAL
TS END POST OR DOO
WINDOW FRAME P01
TS BASE/WINDOVI
NON-STRUCTURAL
GA IF ROLL -UP DOOF
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POST (EACH SIDE)
AND RAFTER CHORD/RAIL WITH
(4) N12-14x 314' SOPS, (2) ON
TOP OR BOTTOM, (2) ON'SIDE
NOTE: AT ROLL -UP DOOR
OPENINGS.'POST SHOULD
BE FLUSH WITH RAIL END.
CLIP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING..
POST TO RAIL, TRUSS CHORD, OR
NON-STRUCTURAL HEADER CONN. DETAIL
Not To Scale
S_FNCRETE BASE RAIL ANCHORAGE
To Scale (OPTIONAL --OPEN CARPORTS ONLY)
24' 16 GA U•CHANNEL BRACE (V TO T POST)
48' 16 GA U•CHANNEL BRACE (8'TO 14' POST)'
BRACE ANGLE SHALL BE MIN. 45'
TO fI 60' FROM HORIZONTAL
NIPPLE
RAFTEF
RAFTER
PLE
TO NIPPLE WITH
SDFs
'Q AURAFTE_Ii�PODETA�`� L�
2A o 1e - -
TS RAFTER POST
1-112'x 1-1/2' x 2` 16 GA CLIP
ANGLE SECURE TO.
POST 'AND BASERAIL
WITH (4) #12-t4'x314' SDFs,
(2); ON TOP, (2) ON SIDE
TS CONTINUOUS BASE RAIL
5 END POST/BASE FAIL CONN.
Nol To Scale
BASE RAIL OEERANCHORAGE
C' Not To Sca'e
NO SCREWS.
REQUIRED'
IN BOW BEND
3'
BOW RAFTER
24'16 GA U.CHANNEL BRACE (S' TO T POST)
48' 16 GA U-CHANNEL BRACE (& TO WPOST)'
BRACE ANGLE SHALL BE MIN. 45'
TO MAXr.60• FROLI HORIZONTAL NIPPLE TO
BASE RAIL
3!�-6' LONG TS NIPPLE
T SECURE RAFTER AND POST TO
1 NIPPLE WITH (4)'02-14 x 3W
RAFTER'POST,
SELFo-DRILLING FASTENERS
(B)!�
RAFTER/POST DETAIL
'
2' x 2.' x 2' 16 GA ANGLE'CLIP
SECURE T.O.POSTAND TOPOF
HEADER, OR BOTTOM OF•WINDOW
RAIUGIRT WITH (4)'#1244 x3/4' SDFs
(2) ON TOP OR BOTTOM. (2) ON SIDE
TS NON-STRUCTURAL HEADER
RAIL OR GIRT
4L SIDING OPTION
REVIEWED FOR
NON-S T 196% '.1f� PAWI
6. RAIL, ""
Not To Scale o LUCTE um p� p'�
® C H,.a
p BASE RAIL ANCHORAGE
l %Not To Sca'e;
6' LONG TS NIPPLE
SECURE POST TO NIPPLE
WITH (4) 012-14 x 311 SDFs
TS RAFTER POST
BASERAIL
POST/BASE RAIL:CONN. DETAIL
` Not To Scale
11-11
I - 9,1H IBp.,
Cet c�taor ' m
m
Tho +t r
P.E.
Ffod�� No ATE 0 ,
�'I SS/ONN-
"'111111101,
2'x2'x2' 16.GAANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4)'#12-14'x 314'
SDFs, (2) ON BOTTOM,,
—2'x4. 16 GA PLATE
SECURE TO EACH SIDE OF
TS END POST POST/RAFTER CONNECTION
WITH (4) #12-14 x 3!4' SDFs,
A (2) ON POST, (2) ON RAFTER
7 END POST/RAFTER. CONN. DETAIL
No(To Scale
1-1/2' x 1-1/2' x2"16 GA
CLIP ANGLE.SECURE TO
RAFTER POST AND GABLE
RAIL WITH (4)'#12-14.x 3M' SDFs
(2) ON TOP; (2) ON SIDE
TS RAFTER POST
1-1/2' x 1-1/Y x 2' 16 GA CLIP
ANGLE SECURE TO RAFTER
AND GABLE RAIL WITH (4)
#12-14'x 314' SDFs, (2) ON TOP,
(2) ON BOTTOM
GABLE RAIL TO RAFTER POST 8�CONNECTION DETAIL
11 A : Not ro score
2-1/4' FOR
12 GA FRAMING
2-112' FOR
14 GA FRAMING
16 GAUGE U,CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2)'#12-14x 314' SDFS,
AT EACH END (4 PER BRACE) —
BRACE SECTION
Not To Sao
NIPPLE
DBL. HO
'S NIPPLE
EACH WITH
x314'
_LING FASTENERS-
GA TS POST
RAFTER POST/DBL. HEADER: DETAIL
Not To,Scale
1-112"x 1-1/2' x 2' 16 GA CLIP ANGLE_
SECURE TO RAFTER POST AND
GABLE RAIL WITH,(4) 0240314' SI
TOP AND BOTTOhi ✓
1-1/27 x 1-1/2',x 2' 16 GA CLIP ANGLE
SECURE TO RAFTER AND GABLE
RNL WITH_(4) #12-14 x 314' SDFs,
(2) ON TOP, (2).ON BOTTOM
SECURE RAFTER AND POST \-TS GABLE RAIL
AtTO NIPPLE 'WITH (4)'#12-14'x'3/4'
SELF -DRILLING FASTENERS
T RAFTER POST
GABLE RAIL T01 RAFTER POST
CONNECTION DETAIL
11 B No1To scale
1-112' 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTERWITH (2) #12 14 X 3/4' SDF
SPACED. NOT MORE THAN 48' O.C.
26 GA. METAL ROOF
PANEL
TS RAFTER
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Scale
POST
8' LONGsTS NIPPLE
SECURE WITH (4)'#12-14 x 3/4-
SELF-DRILLING FASTENERS
TS HEADER
RAFTER POSTMEADER- DETAIL
Not,To�Scale
NIPPLE'
RAFTER
TS RAFTER 12' LONG'TS NIPPLE.
SECURE POST TO NIPPLE
WITH_ (4) #12-14x 3M' SDFs,
6' LONG TS NIPPLE,
SECURE WITH (4) #12-14 X 314- SDFs
24.16'GA U-CHANNEL BRACE (IF TO T POST)
48- 16 GAU•CHANNEL BRACE ,(8'TO 14' POST)
BRACE ANGLE SHALL BE MIN:45''
TO 11AX ,60- FROM HORIZONTAL TS RAFTER POST
SIDE EXTENSION
D12 RAFTER/POST DETAIL
Not To $ta'e;
TS LEG POSTS I'l TS LEG POST
TS BASE RAIL
V-4'
5
NOT TO'SCALE REVIEWED FOR REVIEWED FOR
CODE COMPLIANCE
IAo SCE
SEE GENESTN&=. T-Y
OCC
W LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 314'
SELF -DRILLING FASTENERS
/-12 GA TS POST
TS BASE RAIL
___V__` BASE RAIL
RAFTER POST/SASE
�BARAIL CONNECTION DETAIL
n
TS RAFTER POST
2'x4' 16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POST/RAFTER CONNECTION
WITH (4)'#.12-14 x aW SWs,
(2) ON POST, (2) ON RAFTER
_-TS LEAN-TO RAFTER
27x2'xV,16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4'
SDFs, (2),ON RAFTER,
(2) ON POST'
j1 POST ! LEAN-TO; RAFTER CONN. DETAIL
NofTo Scaie
iron MEn�+16!' 'TINE, Nc
=sT�(
111 3 0 i
ala:o No:64 1
ty
W_
i� PLO..
sl
/�l1F1)►4��
I
sit:�11;1111'ull'jll , l� �► , ` >> �► �[®� �E , (C•�} a� ' li �f •�� �► ���
GIR1
(TYpica
SEE
TYPICAL END
WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE
BOX. EAVE FRAME RAFTER ENCLOSED RLDG e VERTICAL BIDES
ROLL -'UP DOOR SWINGING DOOK
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO. SCALE NOT TO,SCALE
GIRTS
(TYPIcq -1.
mf1 - 18 GAUGE FURRING CHANNEL FASTENEO.TO
EACH RAFTER.WITH (2) U12-14 x 314' SELF -GRILLING
FASTENER SPACED NOT MORE THAN 48' =.
OPENING FOR'SWINGING DOOR .
WITH NONSTRUCTURAL HEADER
g
4
SEE
TABLET
SHEET
OF6
8
6-fw,
.5,
3.
0 9
E
O_1
v.
8
121 IAX. OPEN6N'G FOR
ROLL;UP DWORAlTH
STRUCTURALHEADER
4
4
q.
3
31
4
t0 '
3
4
8
OPENING FOR WbtDowy' H .
NON-STRUCTURALHEADER
LENGTH VARIES DEPEUDING ON 1XI!MR, AND WINDOW RAIL
AND SPACING OF RAFTERS (aso app cab.a !o EM WrEI)'
TYPICAL POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE
i
BOX SAVE FRAME RAFTER UTILITY BLDG o VERTICAL SIDES
TYPICAL SIDE ELEVATION
NOT TO SCALE
ROLL -UP DOOR- SWINGING DOOR.
TYPICAL END ELEVATION
NOT'TOSCALE
REVIEWED
CODE
COMPLiANCE
Bocc
6EC4t-r, �
DEL4N ORIDA- 3272
;Ceit}Rc�p�C 1Y�
�j0 r
Thoma •tol,
Fkuid� 0:38538 �( • ('
XN-
OF�sS l OVO' , .
I111.
INC.