HomeMy WebLinkAboutThreshold inspection report #2M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 20-249 Report No. 2
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
St. Lucie County Bldg. Dept.
Mr. Robert Stark – Structure-Con
Mr. Khris McConnel – Structure Con
Page 1 of 4
THRESHOLD INSPECTION REPORT
OCEAN HARBOR NORTH CONDOMINIUMS – BLDG. A CONCRETE REPAIRS
5155 N. HWY. A1A, FT. PIERCE, FL 34949
SLC BUILDING PERMIT NUMBER: 2012-0537
PROJECT NAME: Ocean Harbor N. Condos – Bldg. A
Concrete Repairs DATE: January 29, 2021
CLIENT: Elliott Merrill Community Management LOCATION: Ft. Pierce, FL
CONTRACTOR: Structure-Con PROJECT MGR: Mr. Khris McConnell
INSPECTED BY: Todd Rhoten WEATHER: Cold & breezy
WORK INSPECTED:
Units 214, 514 & 614 – Concrete demo / pre pour inspection.
Units 314 & 714 – Post pour.
OBSERVATIONS:
Unit 214
• Hurricane shutter tracks have been removed from the top and bottom of the slab.
• The screen enclosure was removed at Unit 114 below.
• Balcony edge demo is complete and the corroded reinforcing has been exposed.
• The bars appear to be in serviceable condition and will require power tool cleaning and coating with the
specified corrosion inhibitor.
• The area of edge repair was limited to the south corner only, approximately 3 square feet.
Unit 314
• Waterproofing and decorative coating has been applied to the repaired areas.
• Stucco at the repaired areas has been applied to match existing and painted with a primer.
• Hurricane shutter tracks have been re-installed and the top and bottom of the slab by the shutter contractor.
Unit 514
• The existing screen enclosure has been removed.
• Hurricane shutters did not require removal.
• The balcony edge demo is complete and the corroded reinforcing has been exposed.
• The bars appear to be in serviceable condition and will require power tool cleaning and coating with the
specified corrosion inhibitor.
• Area of repair was limited to approximately 2 square feet at the edge.
Unit 614
• Hurricane shutter tracks have been removed from top and bottom of the slab edge.
• The balcony edge demo is complete and the corroded reinforcing has been exposed.
• The bars appear to be in serviceable condition and will require power tool cleaning and coating with the
specified corrosion inhibitor.
• Area of edge repair was the entire length of balcony, approximately 12 feet.
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 20-249 Report No. 2
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
St. Lucie County Bldg. Dept.
Mr. Robert Stark – Structure-Con
Mr. Khris McConnel – Structure Con
Page 2 of 4
Unit 714
• Waterproofing and decorative coating have been applied to the entire balcony surface.
• The stucco at the repair areas has been applied to match existing and painted with a primer.
• The shutter contractor is in the progress of re-installing the hurricane shutter tracks at the top and bottom of the
slab.
The repairs are in accordance with design documents and approved for concrete pour.
______________________________ _________________________________
Michael Lue, P.E. Todd Rhoten, Inspector
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 20-249 Report No. 2
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
St. Lucie County Bldg. Dept.
Mr. Robert Stark – Structure-Con
Mr. Khris McConnel – Structure Con
Page 3 of 4
Pic 1
Units 114-714
East elevation
Pic 2
Unit 214
Balcony edge repair area
Pic 3
Unit 614
Balcony edge repair area, full length of balcony
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 20-249 Report No. 2
Project Manager:
Building Official:
Contractor:
File
Mr. Gene Ross – Elliott Merrill Community Mgmt.
St. Lucie County Bldg. Dept.
Mr. Robert Stark – Structure-Con
Mr. Khris McConnel – Structure Con
Page 4 of 4
Pic 4
Unit 614
2” minimum edge clearance
Pic 4
Unit 714
Waterproofing & top coat