HomeMy WebLinkAbout 01) 1st fllor plan pdf. 2/2/21EXIST, RD. WIN, -
NEW F,G. RD. WIN.
(MATCH EXIST, SIZE)
AHU ON SHELF - REMOVE
EXIST, W.H. (BELOW) - ADD
TANKLESS (GAS) W,H, TO
OUTSIDE
y �
001
SOFFIT 8'
ABV, BUILT-IN
\ REMOVE EXIST,
\ FIR, DR, 8 S,L. -
NEW SL, GL, DR,
+�q \
O v
2/NEW PRE-F. B. MTL.
FIREPL E - VERIFY NEW
FINIS W/ OWNER
LIVING ROOM
FLAT CLG.
\
\
\
\
\
\
\
\
\
\
\
.'i NEW ROLL-DN
SCREEN FOR OPN'G,
BELOW BM,
NEW ROLL-DN
SCREEN FOR OPN'G,
BELOW BM,
SC
�c
O
N
GENERAL ADDITION NOTES:
-THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE
EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION
BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR),
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING
CONSTRUCTION.
*EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE
VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)
EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM
MATERIALS, ROOFING MATERIALS, FASCIAS, ETC,
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE
FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND
RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD.
*M,A, CORSON d ,4550C, INC, SHALL NOT BE LIABLE FOR ANY LOSS,
DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES,
CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR
LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS
OR EASEMENTS ARE ENCROACHED. (OWNER, 8 OR
CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS,
EASEMENTS, LOT COVERAGES, ETC,)
\
\
\
GOu. \ \
o„
+8' ENTRY \ \ \ \
Q,, \ \
\
��� /REMMVE EXIST, \
g 30,, / CAST STONE TRIM - \
T� +� ADD STUCCO TRIM \
0, \ \ \ \
FOYER \
REPLACE (2) S,H,\ \
\ �' / WIN, W/ NEW \
\ \ :4 F,G. - VERIFY \
+8, SIZE (8 PLACES)
co,,
\ \
\ \o�o� I I
\\\Qs O I I
\ \ co I I
\ \ x 1 1
\ \ p I I
\ �n 2' 6" x 0" I I
RID, CONC. '3' I I
COL,
I I +c4
I I �
11%5
I I �
I I O
I I w
W- DINING ROOM I 144
rl
I I
IL
O
1 I I w
t I I q
O
*
I I
I I
' oven
I
� tower
1
7 OPN'G
I---- F.R.
MIR o 0
\ EXIST, SOFFIT ABV,
\ TO REMAIN
'
, L
REMOVE EXIST,
SUPPLY
REF.
SUMMER KIT, �~
GAS LINE
25' 4"
(BBQ 8 SINK)
TO ISLAND ](0,011
,
° O
REMOVE EXIST, I
O ==
H,R. WIN, - NEW I
O
;
LARGER I1'VERIF 11
'
F.G. WIN, -VERIFY __
I
i KITCHEN
'
1
----
HT, e WIDTH (B/T
'
ZEENED
GONG. WALL COLS.) I
REOEE EXIST. SOFFITS
'
ff
I
I
I
RICH
I
I
a
AT
WALL LEGEND
F,B,C, 201-1 (&TN EDITION) FOR
EXISTING 5UILDING5
SUMMARY:
THE ALTERATION AREA HAS BEEN
DESIGNED TO: LEVEL 2
* Chapter 5 of the FBC 2011 Existing Building
* less than 5051. of the aggreregate area
* The lateral -force -resisting system of the existing
structure is adaquate to withstand any new lateral
loads of the new addition per Section 801,5 of the
2011 FBC Existing Buildings.
* The existing residence has hardwired smoke alarms and
the new addition shall be hardwired and interconnected
to the exist, system where accessible Per R314,3
2011 FBC,
THE ADDITION HAS BEEN DESIGNED TO: CHAPTER 8
*Chapter 8 of the FBC 2011 Existing Building
8 2011 FBC 8 CHAPTER (o OF ASCE 1-10
HOLLOW d HATCHED =
EXISTING WALL TO REMAIN
SOLID = NEW WALLS
DASHED = EXISTING
- - - - - - - - - - WALL TO BE REMOVED
AREA CALCULATIONS
Exist. let Floor a/c
3,405 S,F,
Exist, 2nd Floor a/c
1,301 S,F,
NEW 2nd Floor a/c
544 S.F.
Total A/C
5,250 S.F.
Garage
1,1013 S,F,
Covered Patio
510 S,F,
Total Non A/C
1,621 S,F,
Total Under Roof
6,811 S.F.
* Contractors to verify all
footages
* All areas are calculated to
outside dimensions,
ORK Ai�EA -
TI-IIS PERMIT
SH 36 SH 36
4' 5" x 6' 4" REMOVE EXIST, 4' 5" x 6' 4"
QUAD.WIN. - NEW
I
3'O"x3'O" F.G. SQ,
4'0"x6'0"
F,G, W/ TRANS,
VERIFY SIZE
-----------------------,
I
I'
1 GARAGE °
I
9'10" CLG, HT, p xtj
8'2" ABV, (O'O' .F.F) m
I'
I (fi
o
I
I
m ,
I'
I
I
I o
I
I
I
I'
I
I
I
I o
I
I
I I �
� xLL
I -
I I o
8" 24' O"
I ;
FIN FL\ -
I V'ARIES CUTG M
NEW e CONC. STEP
_ _ ; RELOCATED BACK TO _
----------------- -
Panel Panel NEW WALL
2' 5" h
FIN, FL, RELOCATED
1 4' roll 31 SIl UP
p 6" 0) RE LOCATED
s---- -- - - --
1- 4
I I
i--i
I I
IL,
EXIST,
STEPS D
I I
I I O'O" FINFL,
p
I I
I I
RCS
'
M
DIFYFLAT GD
.—
A
V, (FL, DEPTH)
2ND FL WALL ABV,
- - - 4 - -
EXIST
- - _T - - - - - -
'
EXIST, - -
STL
-
D
-
STL.
COLS,
- -
COL.
O
_
Q
I I 1 4----- I• --- ` ,
9'O" CLG. HT. I I 1 1 I I
tt 1
\ I L_I__DW__I _Q_ _�_ _L 1G_L______-
\ I I I I I
I �
--------------------------- 11811 x 6" o"
NEW ROLL-DN
, F,G,
REOEE EXIST, NON BRG.
F SCREEN OR OPN G,
0 \ BELOW BM, WALLS
FIXED SCREEN
NEW STUCCO ON ,` \ ENCLOS, W/
EXIST POOL WALL BLK. RETAINING / _ _ _ DOOR
WALL - MATCH ---_------- --
--
EXIST, SEE DETAIL ,
ON SHT, 8 `
0 +�
1 REMOVE EXIST,
FR. DR.NEW FOLDING GL, DR,
9' 1 1/16'1 8' 115/e" 7' 11 5/161,
MORNING R I.
'B'O" CLG, HT,
REMOVE EXIST.
S,H, WIN, - NEW
S'O"x6'O" F.G. WIN,
VERIFY SIZE
3' 1"x6'4"
SH 26
5' O 11
----
51 411
W
3' 1"x6'4"
SH 26
5' O1l
TANKLESS
W,H, (GAS)
NEW - VERIFY
LOCATION
Q
D
U
4
>
1Y
0.
X
w
13' O"
BEDi ROM 2
5,all x5'31,
EXIST, H,R. (IMPACT)
(TO BE PAINTED WHITE)
s
1
13' O" 51 011
' UJ. I.
5EDi ROM 3
OMIT SINK d ADD CAB. Ill IAT1"f 3
KNEE SPACE I 1
I
LINE OF BALCONY COLS,
[PIERS ABV, TO BE REMOVED 1q
(8 PLACES)
MIR o 0
I I
5'a11x5,3'
EXIST. H,R, (IMPACT)
(TO BE PAINTED WHITE)
NEW COND.
VLOJ
----------
O- H----------
(4 .4
m >
4' 61' _
ro 6,1 -
N
ELEU+ N
I I x
I' RSMOIVE ; EQUI I I I
TANKLESS
W,H, (GASd.
0
U
Q
0.
NEW FREE
STANDING
TUB X
W LL
on �-
EXIST, IMPACT
F,G,
EXIST, BLK, PRIVACY WALL
1 L -
RELOCATE
EXIST, VAC
i
U
U IDo
U
zp
O O>
z�N
6-
z
O
(3
o
c9 m
4cp
O„ �
4 �
„,s 0- Qom
4
9
�z
O
zD1�
O- o �
�z o
N O
=
co m :� Q)
N 9
Q
QQ) Q N S
Q N
U 4
6 Q) L1
3 N
•
V
CU
0
c
N
Q0(4
N
..
@0
dN
3
OO
�
U
O
0
�
U�
O
W
U
•
DATE 10/23/20
DRAWN BY p,jg me
CHECKED Mc
REVISIONS
11/30/20 PER S,D
1 2/1/21 WORK AREA