Loading...
HomeMy WebLinkAbout 01) 1st fllor plan pdf. 2/2/21EXIST, RD. WIN, - NEW F,G. RD. WIN. (MATCH EXIST, SIZE) AHU ON SHELF - REMOVE EXIST, W.H. (BELOW) - ADD TANKLESS (GAS) W,H, TO OUTSIDE y � 001 SOFFIT 8' ABV, BUILT-IN \ REMOVE EXIST, \ FIR, DR, 8 S,L. - NEW SL, GL, DR, +�q \ O v 2/NEW PRE-F. B. MTL. FIREPL E - VERIFY NEW FINIS W/ OWNER LIVING ROOM FLAT CLG. \ \ \ \ \ \ \ \ \ \ \ .'i NEW ROLL-DN SCREEN FOR OPN'G, BELOW BM, NEW ROLL-DN SCREEN FOR OPN'G, BELOW BM, SC �c O N GENERAL ADDITION NOTES: -THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR), -OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. *EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM MATERIALS, ROOFING MATERIALS, FASCIAS, ETC, -OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD. *M,A, CORSON d ,4550C, INC, SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES, CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS OR EASEMENTS ARE ENCROACHED. (OWNER, 8 OR CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS, EASEMENTS, LOT COVERAGES, ETC,) \ \ \ GOu. \ \ o„ +8' ENTRY \ \ \ \ Q,, \ \ \ ��� /REMMVE EXIST, \ g 30,, / CAST STONE TRIM - \ T� +� ADD STUCCO TRIM \ 0, \ \ \ \ FOYER \ REPLACE (2) S,H,\ \ \ �' / WIN, W/ NEW \ \ \ :4 F,G. - VERIFY \ +8, SIZE (8 PLACES) co,, \ \ \ \o�o� I I \\\Qs O I I \ \ co I I \ \ x 1 1 \ \ p I I \ �n 2' 6" x 0" I I RID, CONC. '3' I I COL, I I +c4 I I � 11%5 I I � I I O I I w W- DINING ROOM I 144 rl I I IL O 1 I I w t I I q O * I I I I ' oven I � tower 1 7 OPN'G I---- F.R. MIR o 0 \ EXIST, SOFFIT ABV, \ TO REMAIN ' , L REMOVE EXIST, SUPPLY REF. SUMMER KIT, �~ GAS LINE 25' 4" (BBQ 8 SINK) TO ISLAND ](0,011 , ° O REMOVE EXIST, I O == H,R. WIN, - NEW I O ; LARGER I1'VERIF 11 ' F.G. WIN, -VERIFY __ I i KITCHEN ' 1 ---- HT, e WIDTH (B/T ' ZEENED GONG. WALL COLS.) I REOEE EXIST. SOFFITS ' ff I I I RICH I I a AT WALL LEGEND F,B,C, 201-1 (&TN EDITION) FOR EXISTING 5UILDING5 SUMMARY: THE ALTERATION AREA HAS BEEN DESIGNED TO: LEVEL 2 * Chapter 5 of the FBC 2011 Existing Building * less than 5051. of the aggreregate area * The lateral -force -resisting system of the existing structure is adaquate to withstand any new lateral loads of the new addition per Section 801,5 of the 2011 FBC Existing Buildings. * The existing residence has hardwired smoke alarms and the new addition shall be hardwired and interconnected to the exist, system where accessible Per R314,3 2011 FBC, THE ADDITION HAS BEEN DESIGNED TO: CHAPTER 8 *Chapter 8 of the FBC 2011 Existing Building 8 2011 FBC 8 CHAPTER (o OF ASCE 1-10 HOLLOW d HATCHED = EXISTING WALL TO REMAIN SOLID = NEW WALLS DASHED = EXISTING - - - - - - - - - - WALL TO BE REMOVED AREA CALCULATIONS Exist. let Floor a/c 3,405 S,F, Exist, 2nd Floor a/c 1,301 S,F, NEW 2nd Floor a/c 544 S.F. Total A/C 5,250 S.F. Garage 1,1013 S,F, Covered Patio 510 S,F, Total Non A/C 1,621 S,F, Total Under Roof 6,811 S.F. * Contractors to verify all footages * All areas are calculated to outside dimensions, ORK Ai�EA - TI-IIS PERMIT SH 36 SH 36 4' 5" x 6' 4" REMOVE EXIST, 4' 5" x 6' 4" QUAD.WIN. - NEW I 3'O"x3'O" F.G. SQ, 4'0"x6'0" F,G, W/ TRANS, VERIFY SIZE -----------------------, I I' 1 GARAGE ° I 9'10" CLG, HT, p xtj 8'2" ABV, (O'O' .F.F) m I' I (fi o I I m , I' I I I o I I I I' I I I I o I I I I � � xLL I - I I o 8" 24' O" I ; FIN FL\ - I V'ARIES CUTG M NEW e CONC. STEP _ _ ; RELOCATED BACK TO _ ----------------- - Panel Panel NEW WALL 2' 5" h FIN, FL, RELOCATED 1 4' roll 31 SIl UP p 6" 0) RE LOCATED s---- -- - - -- 1- 4 I I i--i I I IL, EXIST, STEPS D I I I I O'O" FINFL, p I I I I RCS ' M DIFYFLAT GD .— A V, (FL, DEPTH) 2ND FL WALL ABV, - - - 4 - - EXIST - - _T - - - - - - ' EXIST, - - STL - D - STL. COLS, - - COL. O _ Q I I 1 4----- I• --- ` , 9'O" CLG. HT. I I 1 1 I I tt 1 \ I L_I__DW__I _Q_ _�_ _L 1G_L______- \ I I I I I I � --------------------------- 11811 x 6" o" NEW ROLL-DN , F,G, REOEE EXIST, NON BRG. F SCREEN OR OPN G, 0 \ BELOW BM, WALLS FIXED SCREEN NEW STUCCO ON ,` \ ENCLOS, W/ EXIST POOL WALL BLK. RETAINING / _ _ _ DOOR WALL - MATCH ---_------- -- -- EXIST, SEE DETAIL , ON SHT, 8 ` 0 +� 1 REMOVE EXIST, FR. DR.NEW FOLDING GL, DR, 9' 1 1/16'1 8' 115/e" 7' 11 5/161, MORNING R I. 'B'O" CLG, HT, REMOVE EXIST. S,H, WIN, - NEW S'O"x6'O" F.G. WIN, VERIFY SIZE 3' 1"x6'4" SH 26 5' O 11 ---- 51 411 W 3' 1"x6'4" SH 26 5' O1l TANKLESS W,H, (GAS) NEW - VERIFY LOCATION Q D U 4 > 1Y 0. X w 13' O" BEDi ROM 2 5,all x5'31, EXIST, H,R. (IMPACT) (TO BE PAINTED WHITE) s 1 13' O" 51 011 ' UJ. I. 5EDi ROM 3 OMIT SINK d ADD CAB. Ill IAT1"f 3 KNEE SPACE I 1 I LINE OF BALCONY COLS, [PIERS ABV, TO BE REMOVED 1q (8 PLACES) MIR o 0 I I 5'a11x5,3' EXIST. H,R, (IMPACT) (TO BE PAINTED WHITE) NEW COND. VLOJ ---------- O- H---------- (4 .4 m > 4' 61' _ ro 6,1 - N ELEU+ N I I x I' RSMOIVE ; EQUI I I I TANKLESS W,H, (GASd. 0 U Q 0. NEW FREE STANDING TUB X W LL on �- EXIST, IMPACT F,G, EXIST, BLK, PRIVACY WALL 1 L - RELOCATE EXIST, VAC i U U IDo U zp O O> z�N 6- z O (3 o c9 m 4cp O„ � 4 � „,s 0- Qom 4 9 �z O zD1� O- o � �z o N O = co m :� Q) N 9 Q QQ) Q N S Q N U 4 6 Q) L1 3 N • V CU 0 c N Q0(4 N .. @0 dN 3 OO � U O 0 � U� O W U • DATE 10/23/20 DRAWN BY p,jg me CHECKED Mc REVISIONS 11/30/20 PER S,D 1 2/1/21 WORK AREA